Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC CHENNAI | L1 | Accepted-AOC BEING THE LOWEST | |
| 2 | L2₹3.4 L+₹36,548 (11.9%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L2 | Rejected-Finance Rejected being not the lowest | |
| 3 | Rejected-Technical 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | - | Rejected-Technical Similar Nature of work Completed mentioned on Sl Page No 08 clause no 13 B 1 of tender documents neither uploaded or hard copies submitted to this office, Hence Rejected. |
Tender Value
₹4.0 L
EMD Value
₹7,900
Closing Date
24 Jun 2021, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Comprehensive Maint and Carrying out Repair/Replacement of DG Sets and Certain other electric work at various location at AGE Tuticorin under GE (I) CG) Chennai
2020_MES_402130_3
8819/GE(I)(CG)
Open Tender
Electrical and Maintenance Works
Item Wise
335 days
Garrison Engineer (I)(CG) Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹7,900
Yes
30 Jul 2021
11 Jun 2021
26 Jun 2021
11 Jun 2021
24 Jun 2021
12 Jun 2021
Amount
Material and labour for carrying out the B check maintenance from authorised rep or service engineer of OEM of DG set of Engine Kirloskar/Mahendra Make of following capacity engine including checking of vibration damper,checking of turbo charger, oil leakage, tightening mounting screws & nuts, replacement of fuel filter and oil and air filter, checking inlet&exhaust manifold cap screws, checking of fan hub & water pump, topping up the level of exiting engine oil or replacement of enginel oil if required, coolant top up complete all as specified and as directed. Note :(a) Engine oil & Coolant will be measured and paid seperately as supply only items. (b) 'B' check shall be carried out on running of 500hours or 6months which ever is earlier. (c) Air filter and fan belt shall be measured and paid seperately if required to be found changed.
(a) DG Set of capacity 160 KVA
(b) DG Set of capacity 125 KVA
(c) DG Set of capacity 100 KVA
(d) DG Set of capacity 50 KVA
(e) DG Set of capacity 30 KVA
(f) DG Set of capacity 15 KVA
Supply and fix lead acid battery 12V 150Ah ,fixed in repair including taking down old one and taken as credit complete all as specifed and as directed. Make Exide/Amron/Tata Green
Supply only air filter both inner and outer for 100/125/160KVA capacity DG Set of Engine Make :Kirloskar/Mahendra including taking down old one and taken as credit complete all as specifed and as directed.
Supply only air filter both inner and outer for 30/50KVA capacity DG Set of Engine Kirloskar/Mahendra including taking down old one and taken as credit complete all as specifed and as directed.
Supply only fan belt suitable for 30/50KVA DG set as per existing model and size including taking down old one and taken as credit complete all as specifed and as directed.
Supply onlyr fan belt suitable for 100/125/160KVA DG set as per existing model and size including taking down old one and taken as credit complete all as specifed and as directed.
Supply and fix in repairFRLS PVC copper cable multistranded of size 3 core 70 sqmm suitable for 12V/24Volts battery complete with brass clamps/legs at both ends including taking down old one and taken as credit complete all as specifed and as directed.Note :Make:Finolex/Polycab/RR Kabel
Supply and fix in repair solenoid switch 3phase 415V(15 to 160KVA)complete set as per existing size and make of any DG set including taking down old one and taken as credit complete all as specifed and as directed.
Repair to self starter 12Volts by taking out old burnt out copper winding wire and rewinding with super enameled copper wire of same gauge including replacement of unserviceable pinion bush solenoid coil carbon brushes & tension spring complete in commissioning and testing including taking down old one and taken as credit complete all as specifed and as directed.
All as per item No : 9.00 here in before but of 24Volt self starter
Supply and fix in repair exhaust insulation cover of thickness 15 to100mm for exhaust pipe for any capacity DG set complete all as specifed and directed.
Material and labour for painting body surface of DG set of capacity160KVA Engine, alternator, AMF panel complete, by applying two coats of synthetic enamel paint complete after preparation of surface complete all as specified and as directed.
All as per item No:12 here in before but 125KVA DG set
All as per item No :12 here in before but 100KVA DG set
All as per item No :12 here in before but 50KVA DG set
All as per item No :12 here in before but 30KVA DG set
Supply and fix in repair dynamo assembly for DG set of 30/50 KVA capacity including taking down old one and taken as credit complete all as specifed and as directed.
Supply and fix in repair dynamo assembly for DG set of 100/125/160 KVA capacity including taking down old one and taken as credit complete all as specifed and as directed
Supply and fix in repair 4Pole power contactor of capacity 63A for AMF panel including taking down old one and taken as credit complete all as specifed and as directed Make:Siemen/ABB/Indo Asian/GE
Supply and fix in repair 200A 4 Pole power contactor with auxillary. contacts for AMF panel including taking down old one and taken as credit complete all as specifed and as directed Make:Siemen/ABB/Indo Asian/GE
Supply and fix in repair 100A 4 Pole power contactor with 2NO/NC auxillary contacts including taking down old one and taken as credit complete all as specifed and as directed. Make:Siemen/ABB/Indo Asian/GE
Supply and fix in replacement of indication lamps LED type 230V for AMF panel including taking down old one and taken as credit complete all as specifed and as directed. Make: Philips/Surya/CG
Supply and fix in replacement of digital multifunction meter suitable for measuring voltage, current etc. including taking down old one and taken as credit complete all as specifed and as directedMake:Make:Secure/L&T/Elmeasure
Supply and fix in replacement of MCCB 4P 200A 25KA for 125KVA AMF panel complete all as specifed and as directed.Make :Siemen/Schneider/ABB
Supply and fix in replacement of MCCB 4P 100A 16KA for 50 KVA AMF panel complete all as specifed and as directed.Make :Siemen/Schneider/ABB
Supply and fix in repairs panel mounting battery charger unit connected to panel of DG set with input voltage of 230V and output voltage 12V DC having charging voltage 13.5V and option like booster/trickle /float and fuse protection including necessary wiring required for connection complete all as specifed and as directed.Make:BEN Electronics/PACTIL/MEC Trivandrum/Sukam/Microtek
Cleaning the fuel tank of DG set of any size/shape /capacity and replacement of fuel level tube including necessary welding complete all as specifed and as directed.
Supply and fix in repair battery terminal brass type suitable for any capacity battery complete all as specifed and as directed.
Supply only Engine oil for DG sets of any capacity complete all as specifed and as directed.
Supply only Coolant for DG sets of any capacity complete all as specifed and as directed.
Supply only distilled water with suitable mix of electrolyte in the batteries complete all as specified and as directed.
Supply and fix in repair change over switch 125A 4Pole with sheet metal enclosure suitable for outdoor type complete all as specified and as directed.Note:Make:Siemen/ABB/GE
Supply only Electric rubber hand gloves 33 kV HT gloves confirms to IS 4770/1968 complete all as specified
Supply and fix 22KV two pole structure Air break switch male and female contactor complete all as specified and as directed.Note:Make:Pactil/BHEL/Jaypura Brothers
Material and labour for provision of earth continuity conductor 32 X 6mm GI stnp with saddles and fixing with screws etc. for roof conductors and down conductor buried in ground or drawn in to pipe complete all as specified and as directed.
Supply and fix lightening arrestor HT 22KV 10 KA station class on 2 pole structure complete all as specified and as directed.Note:Make:Oblum/Elpro/BHEL
Supply only Cotton waste for cleaning
Material and labour for Removing Radiator completely of 125/160 KVA capacity DG Set , Acid cleaning, Water servicing, packing assembly fitting, welding work and refilling, checking turbo radiator servicing, pressure testing and reassembling complete all as specified and as directed..
sri manikandan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .