| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC Lowest and reasonable |
| 2 | L2₹3.7 Cr+₹6.9 L (1.91%)Rejected-Finance | ₹3.7 Cr+₹6.9 L (1.91%) | L2 | Rejected-Finance not being lowest bidder |
| 3 | L3₹3.7 Cr+₹11.2 L (3.10%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | ₹3.7 Cr+₹11.2 L (3.10%) | L3 | Rejected-Finance not being lowest bidder |
| 4 | L4₹4.1 Cr+₹49.7 L (13.8%)Rejected-Finance | ₹4.1 Cr+₹49.7 L (13.8%) | L4 | Rejected-Finance not being lowest bidder |
| 5 | L5₹4.3 Cr+₹69.2 L (19.2%)Rejected-Finance | ₹4.3 Cr+₹69.2 L (19.2%) | L5 | Rejected-Finance not being lowest bidder |
Tender Value
₹2.7 Cr
EMD Value
₹3.5 L
Closing Date
14 Jun 2023, 6:00 pmClosed
Chief Engineer Bhopal Zone
Headquarters Chief Engineer Bhopal Zone Military Engineer Services Sultania Infantry Lines Bhopal
PROVN OF 03 WATER RETAINING STRUCTURES WITH PUMP HOUSE AT BAIRAGARH, BHOPAL
2022_MES_518789_6
CEBZ/BPL/TOKEN/04 OF 2022-23
Open Tender
Civil Works - Water Works
Lump-sum
365 days
Bhopal
Please refer tender doucuments
4 documents required · 4 mandatory
₹2,000
Garrison Engineer Bhopal
₹3.5 L
3 Jul 2023
5 May 2023
16 Jun 2023
5 May 2023
14 Jun 2023
22 May 2023
Amount
Note:-(i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department.
GENERAL SUMMARY
Lump sum price worked out by the contractor for BUILDING WORK - PUMP HOUSE, OH TANK & UG SUMP as listed in Schedule ‘A’ Part- I (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY FOR EXTERNAL WATER SUPPLY AND DG SET WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXACAVATION & EARTH WORK as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
SCH 'A' Pt - VII (MISCELLANEOUS ITEMS) (Contains Ser item No 3.00 to Ser item No 5.03)
INTERNAL ELETRIFICATION NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-II (Internal Electrification) shall also be applicable.
Material & Labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in and including medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), in mild steel/pressed steel sunken boxes( with earth dolly) with and including of 03mm thick bakelite, laminated hylem sheet top cover of suitable size for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for:-
One light point controlled by one 5/6 amps one way switch
One fan/exhaust point controlled by one 5/6 amps one way switch
One Socket outlet, three / five pin, 5 Amp, controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin. on independent board
One Socket outlet, three / five pin, 5 Amp, controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin on same board
Material & Labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper FRLS conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with and including MS/pressed steel sunken box (with earth dolly) with and including 03mm bakelite, laminated hylem sheet top cover of suitable size, including PVC insulated FRLS multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin amps 15/16 Amp socket outlet independent complete all as specified and directed.
Supply & Fixing MCB, SP, 6 to 32 Amps, B Series, 240 volts, AC breaking capacity 10 kA conforming to IS:13947-3 and IEC-60947-3:2001 complete all as specified and directed.
Material & Labour for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover with handle of 8 mm dia bar, charcoal/salt, funnel with wire mesh etc complete all as specified and directed. [Qty- 1 (Int electric) + 2 (Ext Water supply)] NOTE :- (i) The concrete pit (to be provided atleast 500mm away from earth pit) shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M.
Supply and fixing LED tube light wall / ceiling mounting, capacity of 1 x 18/20W, 6000k, decorative ultra slim linear LED fitting fixture with extruded polycarbonate, environmental friendly, energy efficient integrated driver and 18/20 watts LED lamp fitted includingwiring upto end terminal into ceiling rose complete all as specified and directed. Notes: 1. Warranty for replacement of each LED shall not be less than 05 years from the date of purchase. 2. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits.
Supply & Fixing LED 25W street light fitting, 5700k , energy saving & enviornmental friendly long life, versatile pressure die cast aluminium IP66, road way luminare with high power LED's as light source and lectronic driver suitable for pole dia 35mm including 35mm bore, light grade GI tube bracket, bend to shape, 1.80 m length, with 2 Nos. MS clamps of size 50mm x 6mm with nuts, bolts, washers, etc including connection with 1.5sqmm three single core PVC insulated and PVC sheathed cable starnded copper cable and fixing on walls/poles complete all as specified and directed. Notes: 1. Warranty for replacement of each LED shall not be less than 05 years from the date of purchase. 2. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benifits.
EXTERNAL WATER SUPPLY NOTE:- For items of External Water Supply notes given at the beginning of Sch ‘A’ Part-IV (External Water Supply) shall also be applicable.
Supply, lay, connecting and testing DI Pressure pipes "ISI" marked to IS:8329/2000 (Reaffirmed-2005) Edition 4.1 of dia 450mm with socket spigot ends suitable for "Push-on joint" in standard working lengths supplied with a rubber gasket duly "ISI" marked for water, class K-9 with socket and with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe without Polyethylene Sleeve but including "Push-on joint" supplied with "ISI" marked EPDM Rubber gasket conforming to IS:5382/1985 (Reaffirmed2003) with dual hardness of Type-2 (bulb) and Type-5 (Heel) quality complete all as specified and directed.
All as per BOQ Serial Item No.4.02 here-in- before but 250 mm bore complete all as specified and directed.
All as per BOQ Serial Item No.4.02 here-in- before but 200 mm bore complete all as specified and directed.
All as per BOQ Serial Item No.4.02 here-in- before but 150 mm bore complete all as specified and directed.
All as per BOQ Serial Item No.4.02 here-in- before but 100 mm bore complete all as specified and directed.
Supply, installation, connecting and testing sluice valve cast iron body class-PN 1.6 with flanged ends drilled suitable for bore of pipe 450mm, ISI marked (IS:14846:2000) having brass spindle with iron wheel at top complete with nuts bolts washers rubber gasket etc complete all as specified and directed.
Supply, installation, connecting and testing sluice valve cast iron body class-PN 1.6 with flanged ends drilled suitable for bore of pipe 250mm, ISI marked (IS:14846:2000) having brass spindle with iron wheel at top complete with nuts bolts washers rubber gasket etc complete all as specified and directed.
Supply & Fixing Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast ron Water supply mains of size 100 mm dia. complete all as specified and directed.
Supply & Fixing Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast ron Water supply mains of size 150 mm dia. complete all as specified and directed.
Supply & Fixing Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast ron Water supply mains of size 200 mm dia. complete all as specified and directed.
Material & Labour for Earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to galvanised iron strip of 32mm x 6 mm as earth lead by means of bolts nuts check nuts & washers of galvanised iron or steel ,surrounded by charcoal of coke and salt, protected by GI pipe 40 mm bore (light grade), water pipe 20mm bore GI medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stone aggregate, 50 mm thick cover of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia TMT bars @ 80 mm c/c boath ways including excavation and earth work in any type of soil and removal of surplus soil to distance n exc 50 m complete all shown in electrical plate No 3 of SSR part- 2010 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete all as specified and directed. Note:- (i) The cost of GI strip & G I pipe of 7.50 mtr length for protection of GI wire and excavation work for pit shall deemed to be included in this item. (II) Earthing test will be carried out and if desired result not achieved, the earthing will be redone to achieve desired result without any extra payment.
Supply and laying 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes, SDR 11 (PN-10) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of outer dia 63 mm including all fittings complete all as specified and directed.
Supply, laying, connecting and testing DI Pressure pipes "ISI" marked to IS:8329/2000 (Reaffirmed-2005) Edition 4.1 of bore 200mm with flanged ends on both sides suitable for "flange joint" in standard working lengths supplied with a rubber gasket duly "ISI" marked for water, class K-9 with flange end with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe without Polyethylene Sleeve but including "flange joint" supplied with "ISI" marked EPDM Rubber gasket conforming to IS:5382/1985 (Reaffirmed 2003) with dual hardness of Type-2 (bulb) and Type-5 (Heel) quality complete all as specified and directed.
Laying, connecting and testing Cast iron pipe of bore 450 mm issued from mes store yard with and including necessary transportation of pipe to site complete all as specified and directed. NOTE: CI pipe will be issued under Schedule B free for fixing.
Design, supplying, installing, testing and commissioning LT panel Board cubical KIOSK outdoor type, compact metalised, 415 Volts, AC, 50 Hz, fabricated of CRCA sheet 3.15 mm thick, powder coated, machine pressed wit angle iron frame 50 X 50 X 6 mm duly painted grouted in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete including copper bus bar 400 Amps - 4 Nos strip mounted on porcelain insulators & enclosed in chamber & connection from incoming and out going with openable shutter both sides comprising of following duly CPRI Approved:-
Supply and laying MS Pipe (ERW) Steel including specials, nominal bore 150 mm, as per IS 3589 (1981) thickness 5.4 mm complete all specified and directed.
Supply and laying MS Pipe (ERW) Steel including specials, nominal bore 200 mm, as per IS 3589 (1981) thickness 5.4 mm complete all specified and directed.
Supply & Fixing Non Returning valve, flange type of size 250mm, PN- 10 conforming to IS 9338, including rubber sheet , nut , bolt and all connected accessories complete all specified and directed
Supply, install, testing & commissioning of chemical dosing system plunger type, suitable for 100Ltr/Hrs; comprising of dosing coupled with three phase electric motor capacity 0.5 HP motor of suitable size discharge line, 1440 rpm assembly with agitor in one motor agitor with SS sweep blade fully FRP coated, FRP tank 150 Ltrs capacity with chemical grade PVC NRV including connecting of delivery line of water supply, suitable size starter complete all as specified and directed.
Supply & Fixing cast iron foot valve flanged end conforming to IS 4038, 100 mm dia, PN - 10 including all rubber sheet, nut, bolt, cutting of pipe of suitable length, etc and connected accessories complete all specified and directed.
Supply & Fixing cast iron foot valve flanged end conforming to IS 4038, 200 mm dia, PN - 10 including all rubber sheet, nut, bolt, cutting of pipe of suitable length, etc and connected accessories complete all specified and directed.
Supply & Fixing Non Return valve flange end conforming to IS 4038, 450 mm dia, PN - 10 including necessary rubber sheet , nut bolt all connected accessories etc complete all specified and directed.
Supply & Fixing Non return valve flange end both side conforming to IS 4038, 200 mm dia, PN - 10 including necessary rubber sheet, nut bolt etc complete all specified and directed.
Supply & Fixing Non return valve flange end both side conforming to IS 4038, 150 mm dia, PN - 10 including necessary rubber sheet, nut bolt etc complete all specified and directed.
Supply & Fixing Non return valve flange end both side conforming to IS 4038, 100 mm dia, PN - 10 including necessary rubber sheet, nut bolt etc complete all specified and directed.
Supplying, fixing and testing of DI pipe fittings (specials), heavy duty for any type (flanged/socketed) pipes such as bends (any type radius, and angle) tapers (any type), straight bend, increasing, decreasing or double socket etc, Tee pieces, ring branch, 'Y' junction double branch, cross (all socket or socket and spigot) collors, caps and plugs, adopters, mechanical joint, flange tee, etc of any size radius and lenght confirming to IS:9523/2000 specifications with external bitumen coating and internal cement mortar lining and metalic zinc coating up to 450mm bore complete all as specified & directed.
Supply, install, testing of centrifugal priming pump/vaccum pump of capacity 5 HP, intake 55 LPM, minimum intake rate 55 cum per hour, minimum vaccum develop 650mm/hg, 220 volt, 50 Hz including connection to centifugal pump with & including starter of suitable size/capacity and single core copper cable of 10 sqmm length approx (20 metre) connection from starter to motor complete all specified and directed
Supply and fixing electromagnetic water meter, digital type with RS 485 protocol suitable for 250/200/150mm bore DI/ CI line including all necessury connected fittings/fixtures complete all as specified and directed with following specifications:- EMFM-DN-250/200/150-R-MS-SS316 -,IP 67-0.05% Application Media - Normal Water Liner - Rubber Elecrodes - SS 316 L Connection - 250/200/150 mm Flange End Pressure - 20 - 60 bar Display - integerated Power Supply - 24 VDC/ 220 V AC Signal O/P- Pulse, 4-20 ma, RS 485 modbus Accuracy - +- 0.5% Flow type - SS 304 Housing - MS seat Electronic Housing - Die cast aluminium. NOTE:- Meter size shall be compatible to the pump outlet.
Material & Labour for construction of brick masonary Valve pit chamber of following size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mm x 50mm x 6mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed:-
Item No.4.31 Contd/- 1000mm x 1000 mm x 1000 mm size
Supply & Fixing copper un-armoured cable, single core, 70 sqmm nominal area, 220 volt, 50 Hz including suitable size lugs, etc complete all specified and directed.
Supply, fabrication and fixing MS chennal/pipe fitting/barrel piece /lateral pipe as per site requirement with MS pipe, C class, heavy duty including nut, bolt, washer, clamp, welding etc and fibre board gasket complete and making joint leak proof including dismantling old structure complete all specified and directed.
Material & Labour boring of holes, under road, pavement, hard standing by trencheless method /manual auguring with & including reinforced concrete pipe class NP3 of bore 250mm complete all specified and directed.Note: The rate of pipe class NP3 of bore 250mm is included in this item and nothing shall be paid extra on this account.
Supply & Fixing automatic star delta starter in sheet metal enclosure type, wall mounting suitable for centrifugal pumping set as mentioned in Serial Item No.4.01 here-in- before, 3 phase, 415 volt, 50 Hz, relay range 60 -150 Amp, ML6 contactor, ML over load relay with & including single phase preventor complete all as specified and directed.
DG SET NOTE:- For items of DG Set notes given at the beginning of Sch ‘A’ Part-V (DG Set) shall also be applicable.
Supply, installation testing and commissioning of OEM manufactured, static silent (sound proof enclosure), Disel engine driven generating set capable of delivering 82.5 KVA (in case of non availablity next higher capacity shall be provided witjout any price adjustment), water cooled, 415 volts (AC, 3 phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator through flexible coupling and mounted on common base frame with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet outlet return inlet oil arrangemnet, exhaust pipe complete and suitable for conditions prevelant at site location, (the capacity of engine & alternator shall be worked out taking all derating factors into consideration of the location of site) including PCC foundation of suitable size (leaving atleast 0.5m all round space for easy of movement and 0.5m height) anti vibration pads, including emission control devices to make it compliant of emission limits as brought out in the GSR issued by Min. of Enviornment and all features with latest CPCB guidelines and comprising of following complete all as specified and directed:-
Item No. 5.01 (Contd/-) (i) ENGINE (Prime Mover ) : Diesel Engine 1500 RPM, direct injection six cylinders, type four stroke, confirming to ISO 3046 /BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 82.5 KVA at outdoor atmospheric conditions of site location, (taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start, complete with fly wheel all standard with fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub temperature, pressure guage and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection system (shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc.
Item No. 5.01 (Contd/-) (ii) ALTERNATOR : Brushless AC alternator, 3 phase, 415 volt , 4 wire, rated for suitable output to drive the engine, Minimum power factor 0.8, 1500 RPM, IP 23 protection class enclosure, insulation class “H” salient pole, revolving field single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. Note: Alternator Capacity shall be calculated as per ambient temperature of the site location. (iii) BASE PLATE :- Made out of structural steel as per manufactures recommended design/ specifications. (iv) IN BUILT AMF CONTROL PANAL : Factory made, cubical type, in-built AMF panel borad, indoor type made out of MS angle not less than 25 x 25 x 5 mm and 2 mm thick MS CRCA sheet, front opening type, protection class IP-54, duly powder coated after seven tank process, with electrolytic grade copper bus bar of 200 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of following :- (a) MCCB, 200 Amp, 415 Volts rating, 4 pole, 35 kA rupturing capacity, specially fixed for incoming supply with over load relay, short circuit and fault protection – 01 No with suitable rating HRC back up fuses. (b) AMF logic panel including wiring, power contractor with MCCB suitable capacity for DG Set of main supply, single phase preventor, digital multifunction meter (showing Amps, Volts, Hz, KWH etc.) Emergency stop Button, DG Set over load, High water temp, Low lub oil pressure, Auto charging unit and failure to start, Phase indication lamp LED type RYB including all relays, circuit and protection required for automatic operation of DG Set. (c) Change over switchof bus bar capacity 200 Amp, 440 volt, 50 Hz including all copper lugs, nut, bolt and connected accessories - 03 Nos (v) ACCOUSTIC ENCLOSURE : Sheet metal fabricated cope type, silent enclosure, manufactured on CNC machines as per CPCB norms and powder coated after seven tank process; the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75% load under field condition and OX, 70 DB at 3 M from Gen set when DG set is working at full load alongwith testing conformance, lebelling certification etc as laid down in GSR No. 371 (E) dt 17 May 2002. (vi) Foundation / Plinth / Base : shall be provided as per manufacturers recommendations with atleast 0.5m all round space for easy of movement and 0.5m height (minimum). (vii) Diesel storage tank : shall be as per manufacturers specifications. (viii) MISC: Toolkit, operation & maintenance catalogue, spare part list, overhauling manuals, gurantee card, etc shall be provided as per manufacturers standard practices without any extra cost to the department.
B.K.ASSOCIATES
POONAM ELECTRIC INDUSTRY
Vee kay construction
M/s Khialdas Constructions
M/S JAI BHAWANI CONSTRUCTIONS
MASTER CONSTRUCTION CO
M/s Bijender Singh
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .