| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹24.0 L+₹1.4 L (6.04%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹24.1 L+₹1.4 L (6.30%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹24.1 L+₹1.5 L (6.43%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹24.2 L+₹1.5 L (6.53%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
17 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN-913867
REPAIR/MAINT OF EXTERNAL LT ELECTRIFICATION SECURITY , STREET LIGHTS AND CONNECTED MISC ITEMS AT PEDONG, ALGARAH, AP ALGARAH, DALAPCHAND AND TEESTA TCP UNDER GE 867 EWS.
2022_MES_555946_1
GE / 867 / TOKEN / 17 OF 2022-2023
Open Tender
Civil Works
Item Rate
240 days
Kalimpong
Refer Tender Document
8 documents required · 8 mandatory
₹500
Kalimpong
₹42,000
Yes
17 Dec 2022
4 Oct 2022
19 Oct 2022
4 Oct 2022
17 Oct 2022
11 Oct 2022
5 Oct 2022 - 10 Oct 2022
Amount
M & L for painting of 9 mtr long steel tubular LT pole, vertical complete with cross arms with one coat of aluminium paint after cleaning and preparations of surfaces of poles, cross arms, painting 30 cm wide yellow and black strip on poles upto 1.5 mtr heigh above coping level and numbering of size 70mm x 40mm by using stencil to the pole with black synthetic enamel paint complete all as specified and directed by Eng-in-charge.
M & L for painting of LT panel / feeder panel board with one coat of paint after cleaning and preparations of surfaces of panel with synthetic enamel paint all as specified and directed by Eng-in-charge.
Dismantling/Taking down unserviceable/ damaged/ serviceable steel tubular poles of any type/size including excavation, earth work and demolition of PCC etc and removing materials from site of works complete all as specified and directed by Eng-in-charge.
Supply and errection steel tubular swaged pole type 410-SP-31 (9.0 metre long) confroming to IS-2713 (Part- 1 to 3) 1980 including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws including applying two coats of black bituminous paint internally and externally upto coping and applying two coats of aluminium paint over a coat of red oxide primer (externally from top of coping) including writing MES pole No. with synthetic enamel paint (first grade/quality), complete all as specified and directed by Eng-in-charge.
Fixing only serviceable steel tubular poles retrived under SrI item No.4.00 complete all as specified and directed by Eng-in-charge. (Note for item No 3.00 & 4.00 : Earth work and PCC shall be measured and paid separately under respective items.)
Dismantling / Taking down old ACSR of any size and removing materials from the site of work complete all directed by Engr-in-charge.
M&L Aluminum conductor steel reinforced (ACSR) of any size fixed on steel poles as in overhead conductor as required including binding properly on insulator, jumpering including straining with the existing complete all specified and directed by Eng-in-charge.
Re-fixning only aluminum conductor steel re-inforced (ACSR) retrieved from item Srl item No. 6.00 here-in-above on steel poles as in overhead conductor as required including binding properly on insulator, jumpering all as specified and directed by Eng-in-charge.
S & F Pin insulator porcelain vitreous white , brown or green insulator as per IS 731`-1963 including one Galvanised MS spindle two galvanized iron nuts, washer etc of 100 mm height and 65 mm dia of 1100 volts grade complete all as specified and directed by Eng-in-charge.
M&L insulator Shackle type, porcelain, vitreous, white,brown or green, shall be in one piece and shall have a groove on the side and a hole for a cotter pin and two galvanised bolts and nuts with a pair of straps in size 31 x 5 mm height 75 mm and dia 90 mm, for working pressure 1100 volts complete all as specified and directed by Eng-in-charge.
Fixing only serviceable insulators of any type and size retieved form item ser No 10 here-in-above complete as specified and directed by Eng-in-charge.
Dismantling/taking down old unserviceable galvanized steel earth wire/cradle gurard any size complete all as specified and as directed.
S&F galvanised steel wire 4.0 mm dia for earth continuity conductor complete all as specified and directed by Eng-in-charge..
M&L cradles, hexagonal/rectangualr fabricated with galvanized steel wire of 4 mm/3.15 mm dia including binding, connecting to earth etc complete all as specified and directed by Eng-in-charge..
Dismantling / Taking down old unserviceable stay assembly of any description complete including demolition of PCC and removing materials from site of work complete all as specified and directed by Eng-in-charge.. (Note:- Excavation of earth work shall be measured and paid separately under relevant items)
S&F for stay assembly complete with accessories as shown in electric plate No. 1 using 16mm dia stay rod with galvanized stay stud of size 7/3 of required length complete all as specified and directed by Eng-in-charge.. (Note. Loop insulator, stay clamps, excavation and concrete shall be measured and paid seperately under respective items)
S & F loop type insulator vitreous porcelain white, brown, or green of size 65 X 90 mm 1100 volts grade clearance of hole 16 mm complete allas specified and directed by Eng-in-charge..
M & L for restringing and tightening of existing ACSR conductor on LT overhead line of any size/type after removing from insulators including binding with insulator with aluminium wire of suitable guage complete all as specified and directed by Eng-in-charge..
Labour only for restringing earth continuity conductor any size on LT pole including binding with 16 SWG GI wire complete all as specified and directed by Eng-in-charge..
Taking out old unserviceable / faulty cable of any size/serviceable connecting cable of any size / grade cross sectional area upto 35 sq mm 3.5 core including brick protection for repairs / replacement etc and removing materials from site of work complete all as specified and directed by Eng-in-charge..
All item No 20.00 here-in-above but 50 sq mm to 70 sqmm 3.5 or 4 core LT UG cable all as specified and as directed. . Note for item ser No 22.00 & 23.00 : (a) Relaying of serviceable cable, earth work shall be measured and paid separately under respective items. (b) Serviceable bricks/pipe retrieved shall be stacked separately for resue and cost of the same is inclusive in the item rate. (c) Excavation & necessary earthwork shall be measured & paid separately under relevant items
Supply laying and testing XLPE cable insulated screened PVC bedded, galvanised steelstrip or wire armoured, electric cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of cross Sectional area 10 Sqmm 2 core conforming to IS-7098 (Part-I) - 1988 complete all as specified and directed by Eng-in-charge..
Supply and Laying service cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall with the help of shadel of size 25 Sqmm 3.5 core as required at site all as specified and as directed. Make KEI / Havells
All as per Srl Item No 23.00 here-in- above but 35 Sqmm 3.5 core all as specified and as directed.
All as per Srl Item No 23.00 here-in- above but 50 Sqmm 3.5 core
All as per Srl Item No 23.00 here-in- above but 70 Sqmm 3.5 core
Laying only and connecting, testing in trenches, under floors/roads or on walls Cable XLPE of size up to 35 sqmm cable retrieved from ser No 23.00 here in before complete all as specified and directed by Eng-in-charge.
Laying only and connecting, testing in trenches, under floors/roads or on walls Cable XLPE of size up to 50 sqmm to 95 sqmm cable retrieved from ser No 24.00 here in before all as specified and directed by Eng-in-charge.. Note for Srl item No 25 to 31 : Earth work, bricks, sand and pipes shall be measured and paid separately under respective items.
S & F GI pipes 40mm bore light grade in any position for Protection of Cables fixed at pole/ laid under road / nullah, crossing walls under floors etc complete all as specified and directed by Eng-in-charge.
All as per Srl item No. 29.00 here-in-before but for 50mm bore all as specified and directed by Eng-in-charge.
All as per Srl item No. 29.00 here-in-before but for 80mm bore all as specified and directed by Eng-in-charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in soft/loose soil for taking out/laying UG Cable/foundation of poles/stay assembly/ laying of cable and getting out complete all as specified and as directed.
All as per Item No 32.00 above not exc 1.5m depth and not exc 3 m in depth all as specified and as directed. .
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated material from site to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre from the starting point complete all as specified and as directed.
M&L PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation of poles,stay etc, filling and mass concrete including use and waste of form work complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping, grounting, finished even and fair without using extra cement complete all as specified and as directed.
M&L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete including necessary form work complete repair plinth, foot path, panel foundation etc at Power house and sub stn all as specified and as directed.
Supply & laying well burnt bricks sub class B in trenhes for the protection of cables of size 25 cm x 12.5 cm x 7.5 cm +/-8% tolerance laid flat with length of the bricks perpendicular to the axis of the cable all as specified and as directed.
M&L sand cushioning (dry fine sand) for protection of UG cables (below, above and around the UG cable laid in trenches) and consolidated (punned) complete all as specified and as directed. (Note :- Punned thickness shall be measured).
M & L danger notice plate of 1.6 mm thick mild steel sheet vitreous enameled , white with letter ( in Bengali, English & Hindi ) Figured & conversional “Skull & Bone” in signal red colour & fixed with MS clamps bolt & nuts of approved size 25 X 15 cm for 1100 Volts including dismantling of old danger notice plate and removing materials from site of work complete all as specified and as directed. .
M&L for dismantling of old unserviceable/worn out bus bar chamber after disconnecting all cable connections from the panel complete all as specified and as directed.
S & F MCCB four pole 200 Amp, 415 Volts, 'C' Curve, 36 KA breaking capacity, Ics=100% Icu with thermal magnetic protection including taking down old MCCB complete all as specified and directed by Engr-in-Charge. Make : LEGRAND /SIEMENS/SCHNEIDER.
S & F MCCB four pole 160 Amp, 415 Volts, 'C' Curve, 36 KA breaking capacity, Ics=100% Icu with thermal magnetic protection including taking down old MCCB complete all as specified and directed by Engr-in-Charge. Make : LEGRAND /SIEMENS/SCHNEIDER.
S & F MCCB four pole 250 Amp, 415 Volts, 'C' Curve, 36 KA breaking capacity, Ics=100% Icu with thermal magnetic protection including taking down old MCCB complete all as specified and directed by Engr-in-Charge. Make : LEGRAND /SIEMENS/SCHNEIDER.
Supply and fixing Out door feeder Box of size 600x600x300 mm made out of 2mm sheet ,with 100 Amp Busbar including powder coated paint complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25m deep bellow ground level) with top edge of the plate not less than 1.5m bellow normal ground level, connected to galvanized earth lead wire 4mm dia by means of galvanized iron or steel bolts, nuts, check nuts and washers and connected to equipments as directed, including funnel with GI med grade watering pipe 20mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1:3:6) type C-1, 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I all as specified and as directed.
Taking down LED 150/120/100/90/80/60/45/30/25 watts energy efficient street light fitting, identifying the fault, repair / replacement of old unserviceable accessories with new accessories, re-assembling and make the street light fitting functional and re-fixing in existing location including three core copper PVC insulated conductor of 1 Sqmm size (nominal area) of suitable length to connect the luminaries to overhead conductor/existing lines complete all as specified and as directed. (Note:- Spare parts/material required for repair to street light fittings shall be measured and paid separately under relevant items as supply only)
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including clamp, nut bolt all as specified and directed by EIC.
Supply only in replant three core copper PVC insulated PVC sheathed multi core cable with electrolytic grade annealed copper copper conductor suitable upto 1100V grade confirming to IS:694 conductor of 1 Sqmm size (nominal area) complete all as specified and directed by EIC. Make: Havells/Polycab/Finolex or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 150 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 120 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 100 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 90 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 80 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 60 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 45 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 30 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Supply only in replacement of street light driver of 25 watts, 230 V, 50 Hz suitable for operation over voltage range of 140 V to 270 V by removing from exiting position complete all as specified and directed by EIC. Make: SURYA/HAVELLS/ CROMPTON/ or as approved by GE. Note : Fixing charges of this item is deemed to be included in item No 48 hereinbefore.
Taking down existing worn out GI brackets from pole and supply and fixing GI pipe bracket made out of 40mm dia GI pipe (light grade of length 1.5 meter) bent to the required shape for holding the fitting with proper angle including providing two pair of MS flat iron clamps of size 40mm x 6mm of required length duly drilled for bolt holes with required nuts, bolts and washers of suitable size, including applying two coats of aluminium paint over a coat of red oxide primer to clamps after perparation of surfaces complete all as specified and as directed.
Taking up or down old steel tubing and connections form trenches, wall, floors etc. including disconnection of fittings from tubing including cleaning for re-fixing or removal from site of size 40 mm complete all as specified and directed
Re-fixing the old steel tubing and connections in new or old position in trenches, ground, wall size 40 mm complete all as specified and as directed
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including providing suitable length of three core 2.5 sqmm PVC insulated copper conductor cable complete all as specified and as directed. Make - SURYA cat part No. SLE UL 80W IP66 LXN or equivalent make of Philips /CG approved by GE.
Sub Total of Schedule 'A' (Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment)
Schedule of Credit (Minus) Rs. 24,749.00 B/F from Ser page No. 28 NOTE: Bidder shall insert credit amount as rate Rs. 24,749.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .