Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | ₹14.3 L Quoted ₹15.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹17.4 L+₹2.0 L (13.2%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | ₹17.4 L+₹2.0 L (13.2%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹17.9 L+₹2.5 L (16.5%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹17.9 L+₹2.5 L (16.5%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹26.7 L+₹11.4 L (74.3%)Rejected-Finance | ₹26.7 L+₹11.4 L (74.3%) | L4 | Rejected-Finance BEING L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical INCOMPLETE DOCUMENTS SUBMITTED AS REQUIRED FOR UN-ENLISTED CONTRACTOR |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
20 Sept 2022, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR, MAINT OF CEILING FAN, EXHAUST FAN,WALL MOUNTED FAN, PEDESTAL FAN, METER, INTERNAL WIRING, FITTING FIXTURE,SERVICE CONNECTION,DISTRIBUTION BOARD,BUILDING SUB MAIN, EARTHING,LIGHTNING ARRESTER AND ALLIED WORK AT AFS K HILLS UNDER GE AF THANE
2022_MES_547087_1
8215/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹42,000
Yes
22 Nov 2022
23 Aug 2022
21 Sept 2022
23 Aug 2022
20 Sept 2022
8 Sept 2022
23 Aug 2022 - 8 Sept 2022
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, light fittings, MCB DBs,out let boxes etc.removing material for taking credit and making good disturbed surfaces of walls, floors, ceilings etc,complete all as specified and as directed by Engr-in-charge.
M&L for point wiring with 1.5 Sqmm (nominal area) FRLSH insulated multi-stranded copper conductor confirming to IS 694 in and including Medium duty PVC casing capping (ISI marked)/PVC conduit including fitting & accessories, with MS concealed terminal boxes with 3mm thick laminated BakeliteHylum sheet top cover for mounting switch, socket etc including 1.5 Sqmm stranded copper conductor with green PVC insulated flame retardant copper conductor earth continuity conductor 1.5 Sqmm connected to the common earth dolly and controlled by one switch ,complete all as specified and as directed by Engr-in-charge. for the following as given below:-
One Light/Bell/ceiling fan & exhaust fan point controlled by one switch .
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
Ditto- as per Srl Item No 2.00 above but with 2.5 Sqmm wire for 15 Amp socket outlet on independent board
Supply & Fix switch piano flush button single pole one way 5 Amps, 250 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix Bell push button flush type 5 Amps ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix switch piano flush button single pole one way 15 Amps, 250 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix socket outlet 2 in 1,3 pin, 5A flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix switch socket combination 2 in 1,3 pin, 5 Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix socket outlet 2 in 1,6 pin, 5/15Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix switch socket combination 2 in 1,6 pin, 5/15Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix and fix bell buzzer, Ding Dong AC 230 volt single pole ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix fan regulator Electronic step type for 400 watts ,complete all as specified and as directed by Engr-in-charge.
Supply and Fix Modular switch 1 way 6A,1 module, 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular switch 1 way 16A,1 module, 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular socket 6A-2/3 pin combined 2 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular socket 6A/16A-2/3 pin combined 2 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular switch socket combination 16A,6 pin.3 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair, Modular Bell push button flush type 5 Amps ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair,Modular fan regulator Electronics step type 120 watts 2 module and connecting ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair,Modular white cover plate with frame suitable for 1 module ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair ,Modular white cover plate with frame suitable for 3 module ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair , Modular Metal flush box suitable for 1/2 module. ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair ,Modular Metal flush box suitable for 3 module. ,complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, Modular white cover plate with frame suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, Modular white cover plate with frame suitable for 6 module ,complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, Modular white cover plate with frame suitable for 8 module ,complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, Modular Metal flush box suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, Modular Metal flush box suitable for 6 module, complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, Modular Metal flush box suitable for 8 module, complete all as specified and as directed by Engr-in-charge.
S&F, in repair ,Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals. ,complete all as specified and as directed by Engr-in-charge.
S&F, in repair , capping casing 20mm width,complete all as specified and as directed by Engr-in-charge.
S&F, in repair , lamp holder,PVC/Polycarbonate type with back plate suitable for batten fitting ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Batten type LED light fitting 1x18/20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Batten type LED light fitting 1x9/10 watt 2 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Batten type LED decorative light fitting of 15 watt round including LED bulb complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of energy efficient square surface/ceiling mounted LED down 2x2 luminaire 34/36 watt white powder coated CRCA housing with LED seamless front frame with flat white high transmission acrylic cover ,complete all as specified and as directed by the Engr- in- Charge.
S&F in replacement of energy efficient LED mounted panel of 12 watt white powder coated CRCA housing with LED seamless front frame with flat white high transmission acrylic cover,complete all as specified and as directed by the Engr- in- Charge. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of LED bulding security light fitting of 25/30 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD (I) less than 10%, cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report. ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Bolard light of 8 Watt in repair/replacement of existing lights including LED lamps totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of LED bulb 5/7/9 watt, 230 Volt, 50 Hz, complete all as specified and as directed by the Engr- in- Charge. complete all as specified and as directed by the Engr- in- Charge.
S&F in replacement of energy saver LED bulb 2.7 watt,E27/B-22 230 Volt, 50 Hz, complete all as specified and as directed by the Engr- in- Charge. complete all as specified and as directed by the Engr- in- Charge.
S&F in replacement of energy efficient DRONE LED 32 watt round complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes,complete all as specified and as directed by Engr-in charge.
S&F in replacement of Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall ,complete all as specified and as directed by Engineer-in-charge.
Taking down the ceilling fan/wall mounted fan,Exhaust fan from ceilling,wall,cleaning the dust,drit ,greashing,servicing ,repairing and refixing the original position ,complete all as specified and as directed by Engr-in-charge. Note:- Necessary spare for repairing will be measured and paid in respective items.
M&L for Re winding ceilling fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep1200/1400 mm ,220 volt ,50 HZ,single phase ,complete all as specified and as directed by Engr-in-charge.
M&L for Re winding Exhaust fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep 230/300/400 mm ,220 volt ,50 HZ,single phase ,complete all as specified and as directed by Engr-in-charge.
M&L for Re winding wall mounted fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep 400 mm ,220 volt ,50 HZ,single phase ,complete all as specified and as directed by Engr-in-charge.
Supply only Gun metal bush suitable for particular make of fan of 1200mm /1400 mm sweep ,complete all as specified and as directed by Engr-in-charge.
Supply only gun metal bush suitable for particular make of exhaust fan of 300/380/400 mm sweep ,complete all as specified and as directed by Engr-in-charge.
Supply only ball bearing suitable for particular make of fan of 1200 mm /1400 mm sweep ,complete all as specified and as directed by Engr-in-charge.
Supply only ball bearing suitable for particular make of exhaust fan of sweep 300mm/450 mm complete all as directed.
Supply & Fixing 2.5 Mfd/3.15 Mfd capacity ,complete all as specified and as directed by Engr-in-charge.
Supply only ceiling fan blade for 1200 mm /1400 mm sweep fan as per existing ceiling fan and all as directed by Engr-in-Charge.
Supply only Ceiling fan canopy as per existing and all as directed by Engr-in-Charge.
Supply only down rod suitable for ceiling fan of any sweep and length as per site requirement, all as directed by Engr-in-Charge.
Supply only Capacitor 4 Mfd suitable for exhaust fan of sweep 300mm/450mm complete all as directed.
Supply and fixing in replacement of ceilling fan 5 star rated, 1200 mm sweep ,220 volt ,50 HZ,single phase,complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of wall mounted fan 5 star rated, 400 mm sweep ,220 volt ,50 HZ,single phase, ,complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers ,complete all as specified and as directed by Engr-in-charge.
M&L for Checking of ceiling fan of any sweep ,any type for fixing arrangement including replacement of stainless steel nut ,bolt with double washer,ruber reel & quarter pin as per site including oiling for ceiling fan and making record by taking signautre of users/occuptant by the contractor all as directed by Engr-in-Charge.(Note- This items includes the cost the rubbber reel,ss nut,bolts with double washer & quarter pin nothing extra shall be in this account)
S&F,in repair, single phase multi meter mounting box (650 mm x 450 mm x 150 mm) for mounting 04 Nos electronic meter, shockproof and rustproof, termit restistant, cable entry from bottom side, 100 % weather proof, pole mounting arrangment, temper and pilferage proof, fire retardent-class FV-0 as per IS 11731 part-II or V-0 as per UL-94 including testing, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size ,complete all as specified and as directed by Engr-in-charge.
Taking down sub main wiring of any size complete and making good disturbed surface of walls/floors etc ,complete all as specified and as directed by Engr-in-charge.
M&L Sub-main Wiring with 2-Runs of 6 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 4 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty along with the Wiring drawn in EXISTING CONDUIT/PVC CASING & CAPING, complete all as specified and as directed. Note : (i) Three lenght of wire along with conduit will be measured as one Length.
All as per Srl Item No 64.00 above but of size 2X4 sq mm and 1X2.5 sqmm
All as per Srl Item No 64.00 above but of size 2X2.5 sq mm and 1X2.5 sqmm
M&L submain wiring with two single core through FRLSH PVC insulated unsheathed stranded copper conductor 6 sqmm (nominal area) drawing through PVC capping casing and 4 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly Note : (i) Three lenght of wire along with conduit will be measured as one Length. (ii) Rates are deemed to included with cutting chases for conduit and sinking's for boxes and making good to walls, floors etc.
All as per Srl Item No 67.00 above but of size 2X4 sq mm and 1X2.5 sqmm
All as per Srl Item No 67.00 above but of size 2X10 sq mm and 1X6 sqmm
S&F PVC Conduit 25mm dia, medium grade with necessary Conduit Accessories such as Tee, Bend, Elbow, Junction Box, etc. ISI marked including taking down/out unserviceable PVC Conduit with Fittings, complete all as specified and as directed.
S&F PVC Casing & Cappings, ISI marked, heavy duty of size 25mm with all Fittings including taking down old unserviceable one, complete all as per specified and as directed.
S&F in replacement , single phase multi meter mounting box (700 mm x 480 mm x 210 mm) for mounting 06 Nos electronic meter, shockproof and rustproof, termit restistant, cable entry from bottom side, 100 % weather proof, pole mounting arrangment, temper and pilferage proof, fire retardent-class FV-0 as per IS 11731 part-II or V-0 as per UL-94 including testing ,complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ,Single phase electronic tamper proof energy meter LCD display, static Energy meter as per IS specifications IS 13779, CBIP 88, & IEC 62052-11, IEC 62052-21 suitable for range 10 to 60 Amps with optical port, class 1.0 accuracy duly encased in PVC housing in and including testing and commissioning and multi standard PVC insulated copper conductor cable of 6 Sqmm cross sectional area with bottel lugs for connections, all as specified and directed by Engr-in-charge.
S&F in replacement of LED bulding security light fitting of 25/30 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD (I) less than 10%, cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report.,complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable DB/MCCB/MCB/RCCB of any capacity and making good disturbed surface of wall/floor complete all as specified all as directed.
S & F Loadline Distribution board, TP&N vertical, with Bus bars, 200A, 415V CapNetural links,blanking plates, double door 8 way, with MCCB 63 to 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S&F Loadline Distribution board, TP&N vertical ,with Bus bars, 200A, 415V Netural links,blanking plates, double door 4 way, with MCCB 63 to 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S & F Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 4 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S & F Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 6 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S & F Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 8 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S&F MCB SP 6 to 32 Amps 240 volts 50 HZ having 10 KA breaking capacity ,complete all as specified and as directed by Engr-in-charge.
S&F MCB SPN 40 Amps 240 volts 50 HZ having 10 KA breaking capacity ,complete all as specified and as directed by Engr-in-charge.
S&F MCB SPN 240 volt,50Hz,63 Amp,C Curve,10KA breaking capacity ,complete all as specified and as directed by Engr-in-charge.
S & F MCB TPN 40 Amps 240 volts 50 HZ having 10 KA breaking capacity ,complete all as specified and as directed by Engr-in-charge.
S&F MCB TPN 415 volt 63 Amp,"C" Curve 16KA breaking capacity ,complete all as specified and as directed by Engr-in-charge.
S&F DB box with procted power unit rating 16-25 Amps 240volt 50HZ as per Havells cat part no-DHDUCDP0253016-25.Make : Havells or equivallent make as per Approved make list mentioned in Tender documents.
S & F RCCB DP 6 Amps 240 volts 50 HZ having ,complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCCB TP pole with thermal Release range 40/63 Amps, 18KA, 415V, 50 Hz including extension bar for connection cable, ,complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCCB TP pole with thermal Release range 100-125 Amps, 18KA, 415V, 50 Hz including extension bar for connection cable, ,complete all as specified and as directed by Engr-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to DBs /LT Panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are not satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing.3.Earth resistance of earth pit should be less than 2 Ohms.
M&L for connecting 1100 volt grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tap and over all PVC sheathed in service connction for street light from FRP junction box to street light of size 3 core 1.5 Sqmm,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge.
Supply, perform, testing, commissioning of LT cable straight through joint kit heat shrinkable of 4/2/3.5 core x 10/16/25 Sqmm size,complete all as specified and as directed by Engr-in-charge.
Material and labour for earth pit chamber of size 0.6mx0.6mx0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chamber of size 200 mm depth, 300mm length and300mm width ,complete all as specified and as directed by Engr-in-charge.
Material and labour for Brazzing of copper earth strip 20/25/32 mm with available at site and reconnected properly ,complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable and dislocated Copper/aluminium strip of any size from floor of any size height ,complete all as specified and as directed by Engr-in-charge.
S&F copper strip of 20 x 3.15 mm as roof conductor and down conductor till test point all as directed. Note-Copper strip to be jointed through brazing only ,complete all as specified and as directed by Engr-in-charge.
S&F aluminium strip of 25 x 3.15 mm as roof conductor and down conductor till test point all as directed. Note-Galvanised strip to be jointed through brazing only.
S&F GI strip of 32x6mm as roof conductor and down conductor till test point all as directed. Note-Galvanised strip to be jointed through brazing only.
Taking down unserviceable and dislocated air termination rod of any type from floor of any size ,complete all as specified and as directed by Engr-in-charge.
S&F single pointed soild copper rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/down conductor ,complete all as specified and as directed by Engr-in-charge.
S&F single pointed soild Aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor ,complete all as specified and as directed by Engr-in-charge.
S&F Porcelain insulators in replacement for fixing Copper strip on wall / Roof bldg with necessary screws washers and nut bolts etc all Specified . Note - Rates are inclusive of copper screws with washers for fixing copper strip on porcelain insulator with minimum size 1 inch and maximum size 1.5 inch with max external dia of screw is 8mm and 2 nos of GI nut for fixing insulator on wall all as per site requirement ,complete all as specified and as directed by Engr-in-charge.
S&F,in repair,Medium grade GI pipe of 20 mm dia for fixing air termination rod, the pipe shall be suitably tapered for fixing the saddle insulator at an interval not exceeding 0.5 meter, the pipe should be laid vertically and should be properly supported, length of each vertically pipe should not exceed 3 RM, the air termination rod, down conductors should be insulated from the pipe all as directed.
S&F,in repair, terminal block made with gun metal size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head of gun metal screw ,complete all as specified and as directed by Engr-in-charge.
M&L for earthing,in repair, complete with Copper earth plate electrode 600x 600x 3.15 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal ground level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including connecting to earthing test point and testing on completion including PCC 1:3:6 type C2 for earthing pit, GI light grade protection pipe of size 15mm dia, watering pipe 20mm bore medium grade,earthwork,CI cover,funnel, mesh etc all as required at site and all as directed. Note: (i) 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii) Earth resistance of earth pit should be less than 2 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (iv) Soil resistance test if required shall be the done by contractor without any extra cost.
M & L for Earthing ,in repair,complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including PCC chamber using 1:3:6 type C2 for earthing pit, 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing. 3.Earth resistance of earth pit should be less than 2 Ohms.
Supply, installation, testing of CPRI tested maintenance free earthing system a set of Copper Bonded Earth Rod of 3 meter length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x25x5mm for long lasting and connection. Each copper bonded rod & exothermically jointed bus bar should be CPRI tested on 25 KA fault current. Earth rod should be used with 50 kg earth enhancing compound tha should be ROHS tested & having passed leaching, Sulphur, Corrosion, Resisitivity Test as per IEC-62561-7- an international standard for Earth Enhancement Compound by NABL accredit Lab, and PVC pit cover=1 Nos Note- (i) Vendors are bound to get earthing result less than or upto 2 Ohm with or without the grid of earthing.(Maximum number of new earthings in grid are restricted to 3 nos) Any additional work and material required to achieve the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate)
Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing maintenance free earthing based on 6 mtr long GI pipe 80 mm dia(ID) medium grade, GI strip 32x6 mm (Strip in pipe type electrode) and GI pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the GI pipe electrode including providing FRP pit cover of size 250mm at top ,330mm at bottom and 260mm in height capable to withstand minimum 2 ton driving load.Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.Vendors are bound to get earthing result less than or upto 2 Ohm with or without grid of earthings(Maximum number of new earthings in grid are restricted to 3 nos) GI strip required for interconnection of earth pits in grid must be laid 2 ft below the ground level and the same must be treated with chemical (BFC) if required to achieve resistance value. Any additional work and material required to achieve the required result is included in the cost. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore. Note: 1.GI strip must be connected with GI pipe electrode and other joints through nut bolt in addition to welding.
S&F copper strip of 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground Complete all as specified and directed by Engg.in.Charge
S&F Bib taps for 15mm Bore dia of pipe , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed.
S&F first aid box complete with all necessary medicine complete all as specified and directed by Engineer-in-Charge.
S&F colour first aid chart of size not less than 50x70 cm,Billangual( English & Hindi) complete laminated and pasted on cardboad with hanging arrangment on wall complete all as specified and directed by Engineer-in-Charge.
S&F colour Shock treatment chart of size not less than 50x70 cm,Billangual( English & Hindi) complete laminated and pasted on cardboad with hanging arrangment on wall ,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing ,in repair, GI steel tubings of 15 mm bore dia, medium grade including all necessaory fittings i.e. socket, elbow etc.laid on floor or fixed to wall ,complete all as specified and directed by Engineer-in-Charge.
Supply & fixing ,in repair,GI steel tubings of 15 mm bore dia medium grade including all necessary fittings i.e. socket, elbow etc.laid on floor or fixed to wall ,complete all as specified and directed by Engineer-in-Charge.
S&F Mild Steel Sheet of size approximate 300x200x1.6mm thick Sheet Egg type, Half round type, Rectangular type and Triangular type with welded 1ʺ (Inch) dia 2ʹ (Feet) long Mild Steel Pipe with duly different Synethic Enameled Paint cutting of Equipment Earthing/ Lighting Arrester Earthing/ Signal Earthing, etc. complete as specified duly painted as specified and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date including taking down unserviceable one, complete all as specified and as directed.
M&L for Cutting existing 15 mm steel tubing for alterations or additions (Each cut measured) complete all as specified and directed.
M&L for Cutting existing 20 mm steel tubing for alterations or additions (Each cut measured) complete all as specified and directed.
M&L for periodical testing and measuring the earth resistance value of the existing earthings / Down conductor / air terminal by means of wheat stone bridge method after disconnecting the earth continuity conductor from the test point , applying secondary voltage across the terminals, maintaining proper record of the measurement in presence of the users rep, MES rep, submitting the test records, pouring saline water in the earth pit to achieve low earth resistance, observing the same complete for Quarterly Building earthings,L2/L3 eqpts/E&M installations/Lightning arresters test ,complete all as specified and as directed by Engr-in-charge. (Note -(i) Item rate include the cleaning dust/dirt from earth pit chamber, common salt and funnel shall be measured and paid for separately under respective items as supply only (ii) Equipments used for measuring shall be arranged by contractor at his own cost nothing shall be paid extra)
Supply only Common Salt commercial type
Supply only Funnel with wire mesh of size suitable for 20 mm dia watering pipe.
Saviour Security Systems
sapana enterprises
Safe Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .