Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.5 L+₹18,630 (2.54%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L2 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 3 | L3₹7.9 L+₹58,160 (7.92%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L3 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 4 | L4₹8.3 L+₹92,080 (12.5%)Rejected-Finance | L4 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 5 | L5₹8.6 L+₹1.2 L (16.8%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
20 Jul 2022, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
REPAIR/ /MAINTENANCE OF LIGHTENING PROTECTION SYSTEM, AND REPAIR / MAINTENANCE TO CELLING FANS/EXHAUST FAN /WALL FAN /AIR CIRCULATOR FAN ETC AT AFAC UNDER AGE(I)(AF) COIMBATORE.
2022_MES_531990_1
8869_E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
COIMBATORE
Class-E category-b(i) (see NIT for detail)
7 documents required · 7 mandatory
₹500
AGE I AF Coimbatore
₹18,000
Yes
27 Aug 2022
18 Jun 2022
22 Jul 2022
18 Jun 2022
20 Jul 2022
9 Jul 2022
18 Jun 2022 - 11 Jul 2022
Amount
Dismantling, removing the existing disturbed/displaced Copper / Aluminium /GI strips of any sizes from the roof/wall of building, and keeping in a safe custody for taking credit or for re-using serviceable strips in the work complete all as specified and directed.
Fixing only serviceable Copper/Aluminium/GI strips of any size as retrieved from taking down item by straightening, removing the kinks along the length and refixing the same with and including new porcelain insulators/saddles/screws complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs Aluminium strip of size 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground level all as specified and directed by Engineer-in-charge. Note:-Care should be taken by using all safety devices to ensure safety while working.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation or for loop earthing complete of copper strip size 20x3 mm fixed by using and including suitable size of porcelain insulators in such a manner that strip can be separated from the wall.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation or for loop earthing complete of copper strip size 32x6 mm fixed by using and including suitable size of porcelain insulators in such a manner that strip can be separated from the wall.
Supply and fix in repairs Galvanished iron strip 32x6 mm with saddles and fixing screws etc for roof conductors and down conductors above ground all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Air Termination, single pointed Aluminium rod 12mm dia and 300mm long including taking down old unserviceable air termination rod, all as directed by Engineer-in-Charge.
Supply and fix in repairs Test Point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexognal head screw.
M&L for demolition of existing earth chamber including removing the demolished material to the distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point and construction of new earth chamber only in same location as per Electrical plate No.3 as shown in SSR Part I 2009 (Section-19) on Page No. 497 including excavation on any type of soil, returning filling, removal of surplus material to a distance of 50 metre with specification PCC 1:3:6 type C1 using 20mm graded stone aggregate for bed and chamber, RCC 1:2:4 type B1 using 20mm graded stone aggregate for earth Pit cover 50mm thick with 8mm dia TMT bars at 140mm C/C bothways (instead of CI cover) with lifting handle and fixing of funnel complete with colour code all as specified and directed by Engineer-in-Charge.
M&L for Magnesium sulphate mixing in water, and pouring in existing earth pits in camp area to hold moisture in earth pits complete all as directed. Notes:- (i) Total quantity brought by contractor shall be deposited in MES store. (ii) The locations of earthing pits and quntity of pottasium nitrate to be poured shall be as directed by Engineer-in-charge
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI strip 25x4 mm connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth lead strip connected to main switch board/ testing point and protected by galvanised iron pipe medium grade 32mm bore and watering pipe 20mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. Note:- (i) The unit rate includes earth lead strip, and protection pipe upto 7.5 metre.
Taking down ceiling fan of any size, type and make after disconnecting the electrical connections, servicing, cleaning, greasing, replacing the, rubber bush ,lock pin and re-assembling/hanging the same back at site complete all as directed by Engr-in-charge. Note:- i)Spares such as bearing/bushes shall be measured and paid separately under relevant item. ii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shall be borne by tenderer without any extra cost.
M & L for replacing the old unserviceable ball bearings with new ball bearing of size suitable for 1200/1400 mm sweep ceiling fan all as specified and as directed.
Removing the ceiling fan from position after dismantling the electrical connectioin and taking down the old burnt out copper winding wire and rewinding the same by using same gauge of copper wire, duly applying varnish complete all as directed for 1200/1400 sweep ceiling fan.
Removing the exhaust fan from position of any size type and make, after disconnecting the electrical connections, servicing, cleaning, greasing, and re-assembling/fixing the same in position back at site complete all as directed by Engr-in-charge. Note:- i) Spares such as bearing/bushes shall be measured and paid separately under relevant item. ii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shall be borne by tenderer without any extra cost.
M & L for replacing the old unserviceable ball bearings with new ball bearing of sizes suitable for exhaust fan of size 225 mm sweep to 450 mm sweep.
Removing the exhaust fan from position and taking down the old burnt copper winding wire and rewinding the same by using same gauge of copper winding wire duly applying varnish complete all as directed of size 225/305 mm.
All as per item No 16 above, but of size 380 mm.
All as per item No 16 above, but of size 400/450 mm.
Removing the wall mounted fan/air circulator/ pedestal fan of any size, type and make after disconnecting the electrical connections, servicing, cleaning, greasing reassembling/ hanging the same in position back at site complete all as directed by Engineer-in-charge. Note:- i) Spares such as bearing/bushes shall be measured and paid separately under relevant item. ii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shall be borne by tenderer without any extra cost.
M & L for replacing the old unserviceable ball bearings with new ball bearings of sizes suitable for wall mounted fan/ air circulator/ pedestal fan of any size.
Taking down old burnt out copper winding wire of wall mounted fan/air circulator/ pedestal fan of size 300/350 mm and rewinding the same by using same gauge of copper wire duly applying varnish complete all as directed by Engineer-in-Charge.
All as per item No 22 above, but of size 400/450 mm.
S & F 100 watt, 230V, 50Hz electronic stepped type regulator (switch type size) suitable for ceiling fan including taking down the unserviceable one.
All as per item No 24 above, but of socket type.
M&L for replacing unserviceable capacitors from Ceiling fan/Exhaust fan/wall mounting fan/air circulator of any sizes complete of capacity 2.5 MFD.
All as per item No. 26 above but of capacity 4 MFD.
M & L for replacement of unserviceable burnt flexible cable copper conductor twisted 3 core 23/0.0075 mm size and connecting to ceiling fan all as directed.
M&L for exhaust fan blade heavy duty metallic material factory painted complete suitable for 300/380 mm exhaust fan complete all as specified and directed.
M&L for exhaust fan blade heavy duty metallic material factory painted complete suitable for 400/450 mm exhaust fan complete all as specified and directed.
M& L painting of ceiling fans complete, in situ with synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc all as specified and as directed. for fans all as directed for the ceiling fans of 1200/1400 mm sweep.
All as per item No. 31 above, but for Exhaust Fan 225 mm / 300mm sweep with Grey paint.
All as per item No. 31 above, but for Exhaust Fan 450 mm sweep with Grey paint.
M&L for circular / rectangular framed louver shutters suitable for 225 mm sweep exhaust fan made out of MS sheet not less than 1 mm thick for frame & not less than than 0.6mm thick for shutter painted with two coat of synthetic enamel paint over a coat of red oxide primer complete with neccesary fixing accessories all as per existing & as per site requirement & directed by Engr-in-charge. Note - The work shall be carried out for a height variying from GL to 15 metre.
All as per item No.34 above, but suitable for 300 mm sweep exhaust fan
All as per item No.34 above, but suitable for 450 mm sweep exhaust fan
Taking down water heater (Electric Geyser) storage type of any make of 25/50 Ltrs capaciry after disconneting the existing electric wire, water pipe and re-assembling in all respects after replacing unsv parts/components and testing for proper working after repairs and fixing in the original place postion duly connecting up water supply and electric supply complete inc civil work for grouting etc all as specified and directed. Notes:-(i) Necessary repairs / replacement of parts shall be measured and paid separately under relevant items. (ii) Labour element for replacing of unserviceable parts deemed to be included in rate quoted.
Supply only the following suitable parts in repair for water heater (Electric Geyser) storage type of any make complete all as specified.
Supply only Thermostat suitable for 25/50 Ltr capacity.
Supply only Heating Element 1500 Watts 230 Volts push/screw type.
Supply only Heating Element 2000 Watts 230 Volts push / screw type
Supply only Thermostat switch of any type any make.
Supply only neon Indicator bulb red/green colour AC 230 Volts (Round/Square)
S&F in repair heavy duty hot water pipe 45 cm long with two Nos brass check nuts and rubber washers suitable for 15mm dia GI pipe for hot water connection for geysers all as specifid and as directed.
S&F in repair heavy duty hot water pipe 60 cm long suitable for inlet & outlet check nuts and rubber washers suitable for 15 mm dia GI pipe for cold water connection for geysers all as specified and as directed.
Supply and Fix in repair PVC insulated flexible wire 2.5 Sqmm with copper conductor multistranded 3 core for connecting Geysers complete all as specified and directed.
Supply and Fix in repair Plug top 15 Amps all as specified and as directed.
Supply only in repair switch socket combination 2 in 1, 5 pin 6/16 Amps flush type universal all as specified and as directed.
Supply only in repair switch socket combination 2 in 1, 3 pin 6 Amps flush type universal all as specified and as directed.
KUMAR AGENCIES
Rajapriyaconstruction
BHARATH TECH
ANAND REFRIGERATION
CAK Enterprises
p.chinnasamy
SEMBA ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .