Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹13.1 L+₹52,617 (4.19%)Rejected-Finance PULGAON | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹13.2 L+₹63,420 (5.05%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹14.0 L+₹1.5 L (11.7%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹14.1 L+₹1.6 L (12.5%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | vedant engineering enterprises L4 | M/S Maa Durga Constructions,Pulgaon L2 | CHAUDHARY AND ASSOCIATES L5 | Bhirud Electric Stores L3 | JANARDHANANDSONS L6 | Pranati Enterprises L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. | 395 | Cum | 200 ₹79,000 Lowest | 200 ₹79,000 Lowest | 320 ₹1,26,400 | 325 ₹1,28,375 | 450 ₹1,77,750 | 200 ₹79,000 Lowest |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. | 358 | Cum | 50 ₹17,900 | 40 ₹14,320 Lowest | 140 ₹50,120 | 80 ₹28,640 | 170 ₹60,860 | 50 ₹17,900 |
| 3.00 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. | 36 | Cum | 30 ₹1,080 Lowest | 40 ₹1,440 | 250 ₹9,000 | 350 ₹12,600 | 350 ₹12,600 | 50 ₹1,800 |
| 4.00 | Supply & laying DWC Cable duct pipe of size 50 mm bore confirming to IS :16205 Part 24 for laying of LT cables etc complete with all accessories all as specified and directed. | 1,200 | RM | 65 ₹78,000 | 58 ₹69,600 Lowest | 112 ₹1,34,400 | 110 ₹1,32,000 | 150 ₹1,80,000 | 120 ₹1,44,000 |
| 5.00 | Supply & laying DWC Cable duct pipe of size 60 mm bore confirming to IS :16205 Part 24 for laying of LT cables etc complete with all accessories all as specified and directed. | 170 | RM | 75 ₹12,750 Lowest | 80 ₹13,600 | 135 ₹22,950 | 125 ₹21,250 | 140 ₹23,800 | 130 ₹22,100 |
| 6.00 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable of size 50 sqmm, 3.5 core with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall sheathed including cable gland, lugs, jointing material etc and jointing, connecting, testing and commissioning including taking out existing cable alongwith protection covers complete all as specified and as directed. | 200 | RM | 390 ₹78,000 | 411 ₹82,200 | 450 ₹90,000 | 425 ₹85,000 | 400 ₹80,000 | 380 ₹76,000 Lowest |
| 7.00 | (a) All as per serial item No 6 here in before but 35 Sqmm 3.5 core | 200 | RM | 305 ₹61,000 Lowest | 311 ₹62,200 | 330 ₹66,000 | 320 ₹64,000 | 320 ₹64,000 | 350 ₹70,000 |
| 8.00 | (b) All as per serial item No 6 here in before but 25 Sqmm 3.5 core | 200 | RM | 250 ₹50,000 | 241 ₹48,200 Lowest | 260 ₹52,000 | 260 ₹52,000 | 270 ₹54,000 | 300 ₹60,000 |
| 9.00 | (c) All as per serial item No 6 here in before but 16 Sqmm 4 core | 500 | RM | 210 ₹1,05,000 | 186 ₹93,000 Lowest | 200 ₹1,00,000 | 215 ₹1,07,500 | 240 ₹1,20,000 | 200 ₹1,00,000 |
| 10.00 | (d) All as per serial item No 6 here in before but 10 Sqmm 4 core | 500 | RM | 190 ₹95,000 | 151 ₹75,500 Lowest | 190 ₹95,000 | 205 ₹1,02,500 | 200 ₹1,00,000 | 190 ₹95,000 |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
20 Dec 2025, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH) 422401
AS PER TENDER DOCUMENTS
2025_MES_742145_1
87401/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AHILYANAGAR
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE SOUTH AHILYANAGAR
₹29,800
Yes
27 Jan 2026
29 Nov 2025
27 Dec 2025
29 Nov 2025
20 Dec 2025
13 Dec 2025
30 Nov 2025 - 6 Dec 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
Supply & laying DWC Cable duct pipe of size 50 mm bore confirming to IS :16205 Part 24 for laying of LT cables etc complete with all accessories all as specified and directed.
Supply & laying DWC Cable duct pipe of size 60 mm bore confirming to IS :16205 Part 24 for laying of LT cables etc complete with all accessories all as specified and directed.
Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable of size 50 sqmm, 3.5 core with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall sheathed including cable gland, lugs, jointing material etc and jointing, connecting, testing and commissioning including taking out existing cable alongwith protection covers complete all as specified and as directed.
(a) All as per serial item No 6 here in before but 35 Sqmm 3.5 core
(b) All as per serial item No 6 here in before but 25 Sqmm 3.5 core
(c) All as per serial item No 6 here in before but 16 Sqmm 4 core
(d) All as per serial item No 6 here in before but 10 Sqmm 4 core
S&F in repairs galvanised steel tube 50 mm dia, light grade for protection of cable for the following sizes complete all as directed by Engineer-in-Charge
(b) All as per serial item No 11 here in before but 40 mm dia
Supply & Fixing in replacement GI strip of size 32 x 6 mm buried in ground/fixed to pole, wall including fixing clamp made out of 40x5 mm MSFI nut, bolt and washers complete including taking out old GI strip all as specified and directed by Engr -in -Charge.
S & F in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long all as specified & directed by Engg-in-charge.
S & F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified & directed by Engg-in-charge.
S & F in replacement Aluminium strip 25 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified & directed by Engg-in-charge.
M & L for Preparing surfaces of LT pole by scrapping old paints and applying one coat red oxide primer and two coats of aluminium paint and writing "T" and Pole No in black paint etc complete all as specified and directed by Engr- in -Charge.
M & L for replacement of jump connection of two/four pole structure by using ACSR conductor weasel, alkathine pipe ,aluminium lugs, nuts, bolts etc. all as directed by Engineer-in-charge.Note:Rates includes Conductor,Pipes,Lugs,Nutbolts etc.
M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground in any type of strata (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2020 and connection to earth test point all as specified incl testing on completion”.Note:The unit Rate includes earth strip and protection pipe up to (max 7.5 metre) from earth plate/earth point/test point.
Material and Labour for dehyderation, filtration and cleaning of transformer oil, both indoor/outdoor/ pole mounted/plinth mounted 400/200 KVA, HT switch gear etc at different locations by suitable dehgydration plant testing of oil sample before and after dehydration for each transformer/equipment and results of transformer oil dielectric strength minimum upto 42 KV , recorded jointly by contractor and Engineer-in-Charge complete including all necessary tools, plants, transportation etc all as specified/directed by Engineer-in-Charge. Note : Oil for toping up/fresh fill shall be measured and paid seperately under relevant item.
Supply & filling of transformer oil in transformer in situ/ at site for toping up the level of oil having dielectric strength 40-60 KV during filling after initial filtration conforming to IS-335 of make POWER/INSOLE/UNIVERSAL (Transformer oil shall be supplied in sealed container and empty barrel of transformer oil will be deposited by contractor in E/M store yard)
M&L for repair to transformer pole mounted/plinth mounted of any capacity to stop the leakage of transformer by lifiting core assembley with the help of chain pully block/crane, removing transformer oil, replacing cork sheet gasket 5mm thick, reassembling, the transformer completely refilling transformer oil, connecting HT/LT connection,and required for replacement of unserviceable nuts/bolts/washer all as directed by Engineer-in-charge (Note : Spares required shall be measured and paid separately )
M&L for replacement of breather assembley with silica gel.
S & F in replacement of HV rod brass, 12mm dia with brass nut 2 Nos and rubber bush 300mm long all as directed by Engineer-in-Charge.
S & F in replacement of LV rod brass 15mm/20mm dia, 300mm long with rubber bushing and brass nuts 2 Nos all as directed by Engineer-in-Charge.
S & F in replacement MCCB 400 Amp 4 pole 36 KA complete all as specified and directed.
S & F in replacement MCCB 250 Amp 4 pole 36 KA complete all as specified and directed.
S & F in replacement MCCB 160 Amp 4 pole 36 KAcomplete all as specified and directed.
S & F in replacement MCCB 25-100 Amp 4 pole 16 KA complete all as specified and directed.
Supply and fixing 415V MCB TPN 100 Amps 10 KA1 'C' Curve complete with connection testing and commissioning.
Supply and fixing LT cable route indicator cast iron of suitable size with height of 0.6 metre along with LT cable trench including planting in ground with PCC complete all as specified and directed.by Engr-in-Charge.
M&L for disconnecting and taking down U/S street light fittings/gate lights & garden lights of any type/rating from pole or wall dismantling the same for necessary repair or replacment of U/S spars complete and refixing, connecting and testing the same all as specified and directed by Engineer-in-Charge. Notes:- (a) Spares/accessories required for replacement shall be measured and paid sepratley as under respective items of BoQ. (b) T&P required for repair/ mantenance such as ladder, vehicle like crane, manpower etc, shall be included in the quoted rate of this item.
Supply and fix LED drivers compatible with industrial & outdoor LED fixtures/Sign boards as per existing make and model of following ratings:- (a) Suitable for 30 Watt LED fitting
(b) All as per serial item No 33 here in before but Suitable for 50 Watt LED fitting
(c) All as per serial item No 33 here in before but Suitable for 60 Watt LED fitting
Supply and fixing GI pipe bracket light grade of 40 mm dia ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc compltete and dismantling of existing old u/s brackets of all as specified and directed by Engineer-in-Charge. (Note: - The total length of the bracket shall be 1.5m)
Supply and fixing GI pipe bracket light grade of 50mm dia ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc compltete and dismantling of existing old u/s brackets of all as specified and directed by Engineer-in-Charge. (Note: - The total length of the bracket shall be 1.5m)
Supply and fix 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor following size including taking down old U/S cable :- (a) 2.5 sq. mm 2 core
(b) All as per serial item No 38 here in before but 4 sq. mm 2 core
(c) All as per serial item No 38 here in before but 10 sq. mm, 2 core
S & F in repairs PVC weather proof, hinged door, junction box with Aluminium bus bar, 240V, Neutral link and 1No MCB SP of 6/10 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc with pole including dismantling of old junction box all as specified and directed.
S & F in repair overload protection relay suitable for ML-4 FASD starter , MN-5, relay range 45-75, direct mounting on MNX 45-80 and currenct cap 160 A Max complete all as spd and as directed.
S & F in repair 3 pole power contactors block ML-4, IS/IEC-60947-4-1 and IEC-60947-4-1 type, 100A AC-1 and 70A-AC-3 type, 415V, 50 HZ complete all as specified and as directed.
S & F in repairs 3 pole power contactors block ML-3, 40A, AC3, 415V, 50 HZ and 45Amps-AC-1 type and IS/IEC-60947-4-1 complete all as specified and as directed.
S&F in repairs LED Flood Light 120 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in repairs LED Flood Light 210/200 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in repairs LED street light fittings 70 Watt 230 Volt AC outdoor type with high pressyre die cast aluminium hosing and heat resistant complete with driver, lamp braket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repairs LED street light fittings 35 Watt 230 Volt AC outdoor type with high pressyre die cast aluminium hosing and heat resistant complete with driver, lamp braket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on LT pole & Installation of 25x20 cm size
Dismantling street light pole with light fitting and all accessories complete all as specified and directed.
Supply and errect in true vertical in replacement of steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-55 (09 mtr long) Made out of ERW MS tubing confirming to IS-2713 Part II complete including painting with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for paver block or pole / struts foundation etc all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed.
S & F in repairs steel bus bar box weather proof, hinged door, with Aluminium bus bar, 240V, Neutral link and 200 Amp, size of 300X300 width of 75 mm mm, necessary fixing arrangement such as clamps, nut, bolts, etc with pole including dismantling of old bus bar box all as specified and directed.
S & F Street light timer switch smart programmable time switch digital DIN rall mounted, 220 volts, 30 Amps complete all as specified and as directed including taking down old one, Make ; AMICI or other equvellant.
M/S Maa Durga Constructions,Pulgaon (BID ID -3504649)
Bhirud Electric Stores (BID ID -3506626)
vedant engineering enterprises (BID ID -3501717)
CHAUDHARY AND ASSOCIATES (BID ID -3505583)
JANARDHANANDSONS (BID ID -3509172)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
87401TENDERDOCSALL.pdf
Tender Documents • 2.19 MB
BOQ_831037.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .