| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.8 L+₹29,139.50 (1.77%)Rejected-AOC | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹17.3 L+₹80,394 (4.88%)Rejected-AOC | L3 | Rejected-AOC Other than lowest | |
| 4 | L4₹17.9 L+₹1.4 L (8.59%)Rejected-AOC | L4 | Rejected-AOC Other than lowest | |
| 5 | L5₹18.3 L+₹1.8 L (11.1%)Rejected-AOC | L5 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
9 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 874 EWS C/O 56 APO
GE 874 EWS C/O 56 APO
REPAIR TO WALL FENCING GATE DRAIN AND OTHER MISC BR WORKS ALONGWITH PERIODICAL SERVICES IN THE AOR OF AGE BR-III
2022_MES_517590_1
GE 874/EWS-03/2022-23
Open Tender
Civil Works
Item Rate
180 days
Kupwara
As per NIT and tender documents
6 documents required · 6 mandatory
₹500
GE 874 EWS
₹45,000
Yes
21 Jun 2022
11 Apr 2022
11 May 2022
11 Apr 2022
9 May 2022
25 Apr 2022
11 Apr 2022 - 18 Apr 2022
60 days
Amount
B/R Portion
Demolition of cement concrete of any description and in any position not otherwie specifically provided for, complete all as specified and as directed.
Demolition of cement concrete (reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Rendering for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4, to be finished even and fair, complete all as specified and directed.
Rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
Brick work with subclass ‘B’ bricks straight or curved on plan exc 6m mean radius, built in Cement Mortar 1:6 all as specified and directed.
Walling of random rubble stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:4, brought up to courses, complete all as specified and directed.
All as per item above but except stone, complete all as specfied and directed.
Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, confirming to Fe-410-W (Gde E-250) Quality-A complete all as specified.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade on 15mm thick screed bed in Cement Mortar 1:4 over 25mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone agg, complete all as specified & directed.
Chequered cement concrete tiles 20cm x 20cm x 25mm thick, including15mm thick screed bed in cement mortar 1:4, set, jointed and pointed in neat cement slurry with grey cement and pigment as in floors complete all as specified and directed.
Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples fixed in repair, complete all as specified.
M&L for Mild steel TMT bars 5mm dia and over and up to and incl 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips, Gde I IS 432 (part I) complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips etc complete all as specified and directed by Engr-in-Charge.
RCC nominal mix 1:2:4, type B-1 (using 20mm graded crushed stone aggregate), as in beams, cantilevers, bressummers, lintel over 1.5 mtr span, and similar work complete all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions and similar works fair finished surface of concrete complete all as specified.
100mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring/path/hard standing/pavement, complete all as specified and directed.
RCC nominal mix 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), nominal mix for column, pillars, piers, post and struts, and similar work complete all as specified.
Precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) including necessary form work complete all as specified and directed.
Mild steel, plain sheet 1.60mm thick in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. complete all as specified.
Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails and straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire stapples or steel pins etc. as directed and all as specified. (Each line wire to be measured).
Restraining and resecuring including making good staples etc. galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing and straining rails and straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire stapples or steel pins etc. as directed and all as specified. (Each line wire to be measured).
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10m opanable length ( total length 90m) having 50 nos rounds per 6 m length, up to 3.0m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tired with G.I. stapels and G.I. clips to retain horizontal, including necessary boldts or G.I. barbed wire tied to angle iron, all complete as per direction of engineer in charge, with reinforced barbed wire tape (R.B.T)/spring core (2.5 mm thick) wire of high tensile strength of 165kg/sq.mm with tape (0.52 mm thick 0 and weight 43.478 gm/metre (cost of M.S. angle, CC Blocks shall be paid separately).
75mm thick PCC 1:3:6 type C-1 (using 20mm stone aggregate) as in sub-bases complte all as specified and directed.
Dismantling structural steel work including door, gate etc.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (20mm graded aggregate) as in coping, plinth band, bed block including rounded or chamfered angle as directed including necessary formwork etc.
Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over and including 15mm thick screed bed in Cement Mortar 1:4 complete all as specified and directed.
Glazed ceramic coloured tiles (300x200mm) /(450x350mm) x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in surface channels of manholes and fair finished using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, moulds etc
PVC connection 15mm size with PTMT nuts on both ends of length 600mm fixed in repair, complete all as specified.
PVC connection 15mm size with PTMT nuts on both ends of length 450mm fixed in repair, complete all as specified.
PVC (SWR) P trap 110/125mm bore, fixed in repair complete all as specified and directed.
PVC (SWR) S trap 110/125mm bore, fixed in repair complete all as specified and directed.
Dismanling of pvc pipe in any discription and any position.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, 150 mm dia.
RCC pipes class NP 2 laid and jointed complete all as specified with coller bore of pipe 200mm complete all as specified and directed.
M&L salt Glazed stone ware drain pipe 150 mm bore grade 'A' laid in trenches and jointed and testing complete all as specified & directed.
Concrete bed to drain pipes of 200mm dia including packing under and haunching against the sides of pipes laid in PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed.
PVC (SWR) pipe 110 mm dia any length single socketed with rubber ring joint, laid in floor /walls as soil pipe complete all as specified and directed.
PVC (SWR) reducer 110/75mm, complete all as specified.
110mm PVC (SWR) junction single, (single T) equal or unequal provided with access door and fixed, complete all as specified and directed.
PVC (SWR) bends any radius 110mm bore provided with aceess door, complete all as specified.
PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint laid in trenches/floor/walls as soil pipe(vent pipe), fixed, complete all as specified and directed.
PVC (SWR) vent cowl 75mm dia bore, complete all as specified and directed.
PVC (SWR) bends any radius 75mm bore provided with aceess door, complete all as specified.
PVC (SWR) SWR floor trap, paln with grating incl jointing with solvent cement of 75 mm dia, complete all as specified and directed.
WHB and urinal gratings of suitable size, fixed in repairs, complete all as specified and directed
Supplying two nos of manpower (2 Safaiwalas daily) to provide services of cleaning of blockages of sewage lines of any dia and depth, manholes of any size and depth, working in foul condition cleaning of manholes and sewage lines by rodding to and fro, flushing with water in sewage lines between successive manholes and keeping the system functional including water closets, floor traps, Nahani traps, gully traps etc, upto final drop/outlet into septic tanks, Dewatering contaminated/ with fine waste material sludge from septic tank and soakage well of any capacity/depth, Cleaning of septic tanks of various capacities including chambers, outlet chambers and removing out all waste solid material / sludge by mean of manually or mechanically and disposing the same to a distance n.exc. 50 mtr and burring in borrow pit within te premises complete incl covering with fresh mud, finally spraying unslaked lime, dry, aroung the septic tank, soakage well and over the pit complete, including cleaning of soil/waste/vent pipes and rain water pipes of any description and size in the area of Drugmulla (lower/upper) Garrison by two Semi-Skilled/unskilled Tradesman, (having minimum educational qualification of matriculation) and in one shift of eight Hours per day (from 900 Hrs to 1700 Hours) for attending complaints of sewage cleaning as instructed by concerned JE with complaint slip and report back to the same JE including maintaining of the record of complaint slips after getting signature of users, complete all as specified and as directed by Engineer-In-Charge. (Upper Drugmulla, and Lower Drugmulla) (Cost of earth work in the pit is deemed to be included in the unit rate quated by the tenderer)
Dewatering/pumping/bailing out contaminated with waste material sludge from septic tank along with inlet outlet chamber of any capacity/depth by vehicle mounted sewage suction machine and disposing same out of cantonment area including taking off manhole covers and putting back the same after cleaning/ removing the liquid waste material of septic tanks and cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces to make hygienically fit, writing the date of cleaning of septic tank with black and white paint of size 150 x 200mm and finally spraying unslaked lime (bleaching powder), dry, around and over the septic tank all as directed and to the entire satisfaction of by Engr-in-Charge. Note:- 1. Qty of liquid sludge shall be measured for payment under this item. 2. Arrangement of Land for the disposal of waste is complete responsiblity of contractor under this item. 3. Arrangement of suction machine is responsiblity of contractor under this item.
Cleaning of septic tanks of various capacities including chambers, out let chambers and removing out all waste solid material/ sludge out of cantoment area in a closed container and borrow pits and covering with fresh mud, writing the date of cleaning of septic taank, with black and white paint of size 150x200 mm and finally sprying unslaked lime, dry around the septic tank and over the pit complete all as directed (Cost of earth work in the pit is deemed to be included in the unit rate quoted by the tenderer) complete all as directed by Engr-in- Charge. ( Qty of thick solid sludge shall be measured for payment under this item)
Applying one coat of synthetic enamel paint, including preparation of old painted steel surfaces sheets of any description over 10cm width or girth not otherwise described complete all as specified.
15mm thick rendering in Cement Mortar 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and smooth without using extra cement complete all as specified and directed.
Two coats of oil bound distemper over a coat of average 1mm thick Birla putty on new plastered surfaces complete all as specified and directed.
Applying one coats of cement base paint on wall over a coat of priming paint including preparation of new plastered or un-plastered surfaces, complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying one coat of white wash complete all as specified and directed.
Preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
One coat of cement base paint on old painted surfaces of walls including preparation of old surface complete all as specified and directed.
Preparation of old plastered surfaces of ceiling and applying one coat of oil bound distemper all as specified.
Preparation of old plastered surfaces of wall and applying one coat of oil bound distemper all as specified.
Applying two coats of synthetic enamel paint over a coat of pink primer including preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth all as specified and as directed.
Supply only Oil bound Distemper in sealed container.
Supply only cement base paint.
Supply only chalk whiting (Lime).
MS SHEIKH NADEEM AKBAR
patriotic builders
M/S SS SHAH WALI & CO
M/S MANZOORAHMAD LONE
Javeed And Co
G N T CONSTRUCTION CO
Bidder Name
patriotic builders
G N T CONSTRUCTION CO
M/S SS SHAH WALI & CO
M/S MANZOORAHMAD LONE
M/S AKHLAQ ENTERPRISES
Javeed And Co
MS SHEIKH NADEEM AKBAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .