Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600 043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹48.7 L+₹2.6 L (5.74%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L2 | Rejected-Finance BEING NOT L1 BIDDER | |
| 3 | L3₹49.6 L+₹3.5 L (7.67%)Rejected-Finance 10 324 L BALAJI NAGAR ARUVANKADU 643 202 THE NILGIRIS | THE NILGIRIS | TAMIL NADU | 643202 | L3 | Rejected-Finance BEING NOT L1 BIDDER | |
| 4 | L4₹50.3 L+₹4.2 L (9.07%)Rejected-Finance 158 A 2 9 DR RAJARATHINAM STREET KATTOOR COIMBATORE 641 009 TN | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L4 | Rejected-Finance BEING NOT L1 BIDDER |
Tender Value
₹42.6 L
EMD Value
₹85,300
Closing Date
12 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Pawan Kumar Goswami, EE GE DSSC
GE DSSC WELLINGTON BARRACKS-POST, WELLINGTON, THE NILGIRIS, TAMIL NADU, PIN-643231
PROVN OF SECURITY LIGHTS FOR PROTECTION FROM WILD ANIMALS AT STABLES AND CERTAIN LOCATION OF DSSC PROVISION OF WOODEN WALL MOUNTED CABINET CUPBOARD IN TRAINING CELL AND PROVN OF AWNING AT MANEKSHAW SMR AT DSSC WELLINGTON
2025_MES_703707_1
8481/E8
Open Tender
Civil Works
Item Rate
180 days
WELLINGTON
PLEASE REFER TENDER DOCUMENTS AND NIT
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹85,300
Yes
7 Jul 2025
7 Apr 2025
14 May 2025
7 Apr 2025
12 May 2025
21 Apr 2025
Amount
S & F Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug,bolt,nut and screws as specified type 410 SP-31 (9 Mtr long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips with yellow and black paint alternatively on external surface above PCC benching, numbering with black paint and painting with bituminous paint internally complete and extrnally for portion embedded in PCC after preparation of surfaces complete all as specified and directed. Note: - (i) Earth work and PCC shall be measured and paid separately.
Supply, erection, commissioning and testing of Mid Galvanized Mast Light 12.5 Meter High suitable for 8 x 150W LED Flood light and having two point suspension system with steel wire rope of 5 mm dia and double drum winch with luminare mounting arm, 01 No. LED type aviation obstruction light including lamp, lightning arrestor spike, power tools including cutting road/hard standing, excavation for RCC foundation complete with following and all as specified & as directed
(a) Mid mast fabricated from steel plates conforming to BSEN-10025/IS:5986, cut and folded to from a polygonal section. Mast shall be in two sections for 12.5 Mtr heights having only longitudinal weld conforming to BS-5135/AWS. The mast is to be provided with a fully penetrated flange which shall be free from any laminations or incursions. The welded connection of the base flange shall be fully developed to the strength of the entire section. The base flange shall be provided with supplementary gussets between bolt holes to ensure elimination of helical stress concentration. For environmental protection of the mast, the entire fabricated mast shall be Hot Dip Galvanized (As per IS-2629) internally and externally, having uniform coating, base dia and top dia should be 150mm in top,360mm in bottom and plate thickness 3 mm for top and bottom respectively & certificate from the OEM regarding the same to be submitted along with the PV & test certificates. (b) An adequate door opening shall be provided at the base of the mast. The opening shall be such that it permits clear access to equipments like winch, cable, wire rope, plug & socket etc. and also facilitates easy removal of the winch for servicing. The door opening shall be complete with a close fitting vandal resistant allen key locking with provision for external lock. The door opening shall be carefully designed and reinforced with adequate steel section so that the mast section at the base is unaffected, and undue buckling of the cut portion is prevented under heavy wind condition. (c) Mast structure shall sustain an assumed maximum reaction arising from wind speed 55 m/Sec as per IS-875 (Part 3) 1987 (three seconds) which is measured at a height of 10 mtrs above ground level. (d) The high mast shall be provided with accessories which include a raising and lowering system (R & L), trailing cable, power tool, lighting finial and aviation obstruction warning light. (e) The wire ropes shall be of stainless steel grade AISI 304 with minimum 5mm diameter and 7/19 construction. Its central cores shall be also SS and have a minimum breaking strength asper relevant standards. The power tool shall be integral type suitable for handling the total head load. It shall have a mechanical torque limiter to ensure safety and also a manual handle shall be provided. (f) The light luminaries shall be 150 W LED, CT >=5700 K made up of pressure die-cast aluminium housing with epoxy powder coated as diffuser with IP 65/66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc of 5 KV or more & high brightness LEDs, luminaire efficacy > 100 lumens/Watt, power factor >/ 0.95, operating range – 140 to 270 V, 50 Hz including appropriate fixing arrangement complete all as per the recommendations & as directed.
NOTE : 1) Design / drawing / BOM/ Technical Specification of the High Mast Lighting system showing the dimensions incl foundation details is to be obtained from the OEM/Authorised Supplier & is to be got approved from the Engr-in-Charge before placing final order to the OEM/Auth Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) The complete work of erection,commissioning & testing of the Mid Mast lights is to be got done from the OEM/Sister concern/auth channel partner only.
Supply,fix and test, in replacement of LED Street light fitting of capacity 60 Watts, CRI >70, Power factor > 0.95, colour temperature 5700K, luminous Efficacy not less than 100 lumen/watt, 6000 Lumens output, IP-66 protection, Impact Resistance of IK-07 including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection,phase to phase protection, over voltage protection,surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cost aluminium housing and finishing eopxy powder coated grey colour after phospho chromate treatment with all accessories inculding bracket for mounting street light pole on end fixing the bracket on pole with suitable GI Clamp Nut and Bolts and connecting up complete all as specified and as directed.
Supply, fix and test LED Flood light fittings for Midmast, of capacity 120 Watts, CRI>70, Power factor 0.95 colour tempracture 5700K, luminous Efficacy not less than 100 lumens/watt, colour temperature 5700K, 12000 lumens output, IP-66 including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection,phase to phase protection, over voltage protection,surge voltage protection etc) unit suitable for working voltage 140-270V AC, 50 Hz pressure die cost aluminium housing and finishing eopxy powder coated with all accessories as per manufaurer instructions and connecting up complete all as specified and as directed.
S&F loop in- loop out junction box,Maintenance free, tamper and rot proof, Fire retardant,IP55 with approx internal dimension 240x130x95mm (HxWxD) or next higher size made out of FRP sheet,Cable entry from top-1 No and bottom-2 Nos with weather proof canopy including din rail with including 01 No MCB SP C series 10 KA of 10 Amps rated and 4 Way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel tubular poles including necessary aluminium clamps, suitable double compression cable glands, lugs and GI nut and bolts complete all as specified and directed.
Supply and fix in replacement of Street light control panel factory fabricated (CPRI type-tested) with MCB TPN 63 A - 1 No, Contactor TP 65 A- 1No, Astronomical Timer Street Light Control Panel with accessories outdoor type including connected switch gears, cables, etc and suitable sheet metal enclosure test and commisioning of Panel of 440V, out door cubical type with suitable provision of 25 x 3 mm angular base and vertical frame along with necessary PCC foundation and locking arrangement complete including taking out old unserviceable panel all as specified and directed. Note:- The quoted rate shall be inclusive of the following:-
(i) Suitable copper control wiring inside Panel board, cable glands, cable lugs, supporting, insulaters etc., (ii) Quoted rate is inclusive of angular base frame and PCC foundation Earth work and connected accessories. (iii) The Panel should be mounted min 0.30m above the ground level (iv) Design / drawing / BOM of the panel showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer. (v) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
All as per item No. 7 above but cross sectional area 25 Sqmm 3.5 core
All as per item No. 7 above but cross sectional area 16 Sqmm 4 core
All as per item No. 7 above but cross sectional area 10 Sqmm 4 core
S&F in replacement of PVC insulated flexible multicore round copper conductor cable of size 3 core 1.5 Sqmm including necessary end connector fixed in PVC Conduit along with pole structure etc with all fixing & connecting accessories all as specified and as directed.
S & F Rigid Non-metallic PVC conduits medium grade (for passing the pvc insulated cable along the pole and wall) of external dia not less than 20 mm including GI/Aluminium clamp for fixing the conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories with aluminium clamp,bolt, nuts etc complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB TPN 6 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth for erection of poles, laying of cables etc and getting out in hard /dense soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 sqm wide & depth exc 1.5m but n.exc 3m for erection of poles and getting out in hard/ dense soil all as specified and as directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm in thick using excavated soil all as specified and directed.
Removing excavated material (soil) to a distance n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and as directed.
Supply, spreading and levelling of riddled earth as specified in IS 1255 in trenches for cable cushioning to fullfill width of excavated trench 8 CM thick before Laying cable and 15 cm thick after laying of cable ,gently punned down , stretching and testing of cable complete all as specified and as directed. Note : Punned thickness shall be measured.
Supply and laying well burnt old size sub class 'B' bricks of size 230mm x 115mm x 75mm bricks in trenches for cable protection of U/G cables above sand cushioning complete all as specified and directed.
M & L for PCC (1:2:4) type B-1,(using 20mm graded stone aggregate) for coping of poles etc including necessary form work etc complete all as specified and directed.
M & L for providing PCC (1:4: 8) type D-2,(40 mm graded aggregate) Cement concrete in foundations filling and mass concrete including necessary form work etc complete all as specified and directed.(For PCC Bed of Poles)
M & L for providing PCC (1:3: 6) type C-2,(40 mm graded aggregate) Cement concrete in foundations filling and mass concrete including necessary form work etc complete all as specified and directed.
Supply and fixing GI pipe light grade (ISI Marked) of size 40 mm for cable protection to be fixed on pole with necessary clamps complete all as specified and directed Note :- Unit rate quoted is deemed to be inclusive of MS clamps of suitable size/number along with nuts/bolts/washers etc. to be fixed on pole.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( erath pit not less than 2.25 mtrs deep below ground level) with the top edge of the earth plate not less than 1.5 mtr below normal ground level,connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel all shown in electrical plate No 3 connected to earthing test point on completeion with and including 40 mm bore medium grade GI protection pipe ( up to 7.5 mtrs long) for earth and 20 mm GI medium grade for watering including PCC Chamber pit & cover with suitable lifiting hooks , with funnel, wire mesh, common salt, charcoal filling, necessary excavation and earth work in any type of soil including testing on completion all as specified and directed .
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M & L for preparing new surface of steel and appling two coats of synthetic enamel paint over a coat of primer red oxide complete all as specified and as directed.
Supply and fix in repairs 18mm thick High Density High Moisture Resistant (HDHMR) Board, both side laminated of approved colour as in shutters, back board, vertical support and horizontal shelves of kitchen/bedroom cupboards fixed with screw to timber framed work etc., including dismantling of existing any type of board and complete all as specified and as directed.Note: All exposed edges/surfaces to be finished with same laminated sheet to match with the other surfaces and nothing will be paid extra. Make : Century/Action Tesa or equivalent.
Supply and fix Stainless steel soft close hinge with 35mm cup dia, full overlay, 110 degree opening suitable for 18mm thick shutters complete all as specified and as directed. MAKE: EBCO/GODREJ/KAFF/HETTICH
Supply and fix Gun metal handle of size 150mm for kitchen/bedroom cupboards fixed with screws complete all as specified and directed. MAKE: EBCO/ GODREJ / KAFF / HETTICH
Supply and fix Magnetic closer of suitable size for cupboards fixed with screws complete all as specified and directed. MAKE: EBCO/ GODREJ / KAFF / HETTICH
Supply and fix hydraulic silent soft closing channel for drawers of size 300 mm lenth for cupboards fixed with screws complete all as specified and directed. MAKE: EBCO/ GODREJ / KAFF / HETTICH
Supply and fix Hasp and staple 75 mm, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
Supply and fix lock for cupboard/wardrobe with two keys and key hole cover (silver,painted finish) fixed with screws complete all as specified and directed. MAKE: EBCO/ GODREJ / KAFF / HETTICH
Excavation in post holes (or similar holes) each n exc 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm ,in watering and removing surplus soil to a distance n exc 50m and making good surface in soft /loose soil all as specified and directed.
M&L for Cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in foundations,filling and mass concrete
M&L for Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates conforming to Fe-410-W(Gde-E-250) quality B complete all as directed by the Engr In Charge.
Supply and fix Polycarbonate sheet of approved colour 4mm thcik solid sheet half round of appropriate size including neccesary drilling,, etc fixed with self taping screws complete all as directted by the Engr In charge
S&F PVC(SWR) 150mm dia half round Rain water gutter incl all joints etc complete all as directed by the Engr In Charge
S&F prepainted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of approved colour having tensile strenth of 550MPA as in roof covering /cladding to wall,crimp curved where necessary fixed with self tapping screws complete all as spd and directed
Supply and fix Alumnium Wind tie (Flat) with 50mm x6mm thck including necessary cutting,drilling and fabrication etc including fixed with self tapiing screws on new or old CGI/Polycarbonate roofing etc all as dirceted
M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggragate steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as directed
Material and labour for two coat SE paint on steel surface over one coat of red oxide primer incl prepareation of new or old steel surface complte all as spd and directed.
DJ Group (BID ID -3292038)
SRI SHIVASHAKTHI CONSTRUCTION (BID ID -3291557)
POOJA ENGINEERING (BID ID -3291840)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .