Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC AOC | |
| 2 | L2₹11.7 L+₹31,466.50 (2.77%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.8 L+₹2.4 L (21.0%)Rejected-Finance AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L3 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
1 Feb 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
Provn of certain B/R and E/M Revenue and Minor works under GE (AF) Borjhar
2020_MES_403460_2
8798/BOR/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Borjhar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹26,000
Yes
10 Feb 2021
12 Jan 2021
3 Feb 2021
12 Jan 2021
1 Feb 2021
20 Jan 2021
60 days
Amount
B/R Portion
Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 mtr in depth for foundation etc shaft, cesspits, manholes etc not exc. 10 sqm on plan and getting out complete all as specified & directed.
M&L for PCC type D 2 (1:4:8) foundation filling and mass conc all as specified and directed.
M/L for mild steel bars 12mm dia and over cut to length, bent to shape required, including cracking bending spirally for hooping for column, hooking ends and binding with the including mild steel wire (annelaled) not less than 0.9mm dia or securing with clips all as specified.
All as per item no 1.03 but 6mm to 8mm dia for stirrups all as specified.
M&L, RCC M-25 using (20 mm graded aggregate) as in Lintel/Plinth beam complete all as specified.
Returning, filling in, trenches the soil in layers not excceding 25 cm thick, watering and well ramming complete all as specified and directed.
Removal of surplus soil to a distance not excceding 50 mtr away & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for brick work with sub-class 'B' bricks (old size) straight or curved on plan exceeding 6 metres mean radius built in CM 1:6 complete all as specified and directed.
Material and labour for rendering 20 mm thick in cement mortar 1:4 to fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for rendering 15mm thick in cement mortar 1:6 to fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply only WPC ISI marked.
M&L Washing, rubbing down and stopping of distempered and painted surfaces including preparation of wall and distempering wall with two coat of distemper oil-emulsion, of white or tinted complete all as specified and directed.
M & L for preparation of new undecorated plastered/concrete surface of wall/roof/floor by rubbing down and two coat of weather proof Acrylic emulsion paint (exterior grade) in camoflauge pattern on Wall,incl nesessary scafolding.over one coat of weathercoat primer all as specified and as directed by Engr-in-charge.
Use and waste of form work to sides of foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for rough finished flat surface of concrete all as specified and directed
S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or including butt welded tubes confirming to IS 1161-1979 grade St -240 as specified and directed.
S& F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550MPa asin roof covering/cladding to wall with self tapping screws complete as as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair face of brick work of walls, finished even & smooth without using extra cement, complete, all as directed.
M&L for preparation of new plastered surfaces of walls and applying finished smooth coat of 3 mm thick white wall care putty to wall or ceiling surfaces, complete, all as specified & directed.
M&L for Provision of gysum board of 9mm thick ceiling tiles size 595mmx595mm for including aluminium anodised section of size, wall angle 30mm x 25mm x 2mm thick, main / cross tee-section 15mm x 15mm x 1.4mm and suspended with 2.18 mm thick GI wire of suitable length and including fixed & aluminium snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer’s instructions. complete all as specified and as directed by Engineer-in-Charge. Make :--(i) Aluminium section : -- INDALCO/ HINDALCO/ JINDAL (ii) PERFORateD /SEMIPERFORateD TILES :--- ARMSTRONG/ LAFARG
M&L Preparation of newly untreated steel and iron surfaces of any description, not otherwise described, over 10 centimetre width or girth and applyingpreming with red oxide zinc chrome and two coat of synthetic enamel paint complete all as specified and directed.
S&F powder coated aluminium anodised door/window/ cubiles frame (square/rectangular/channel) type as required for sliding/ fixed door/window/partition with one or more rebates including joining beads, cleats etc for fixing, aluminium section weight not less than 0.55kg/Rm complete all as specified and as directed.
M&L for glazing with sheet glass 4mm thick ordinary quality fixed with rubber gasket or aluminium beads as required, in square exceeding 0.5sqm in each pane all as specified and as directed.
M&L for 18 to 19 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination fixed with screws or aluminium cleats to aluminium frame work complete all as directed.
S&F powder coated aluminium anodised door shutter, aluminium section weighing 0.55kh/mtr including necessary joining cleats, glazing clips, rubber neoprene packing, handles 02Nos in each door, hinges, anodised aluminium snap beadding screws, aldrop 01Nos, tower bolt 02Nos etc complete all as specifiedand as directed.
M&L for Non-skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38sqm , as in floors, and walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6), complete, all as specified & directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out soft/loose soil.
M&L Plain Cement Concrete Type C2 1:2:4 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair face of brick work of walls, finished even & smooth without using extra cement, complete, all as directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of chalk whiting, complete, all as specified & directed.
S & F mild steel framed work such as grillsn gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders freamed balusters, walk ways, railings, framework of watertanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165 complete all as specified and directed.
M&L for 100mm thick cement concrete Type B2,1:2:4,( Using 20mm graded aggregate). complete all as specified and directed.
M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to atrue surfaces complete all as specified.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even, complete all as specified & directed.
E/M Portion
M & L Point wiring with 1.5 Sqmm PVC insulated and unsheatheed single core multi stranded copper conductor ISI marked 1100 volts grade drawn in ms conduits & accessories on walls/roofs ceiling including replacement of 3 mm thick laminated sheet cover for fixing of switches/sockets etc including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable for earth continuity and connecting to commom earth dolly complete all as specified and directed :-
(a) One Light point controlled by one switch
(b) One Exhaust fan point controlled by one switch
(c) One 3 pin 5 amps switch sockets controlled by one switch piano type SP 5 Amps on a board independent type from switches.
(d) One 5 Amps switch socket outlet on the same board with other switches
M & L Point wiring with 1.5 Sqmm PVC insulated and unsheatheed single core multi stranded copper conductor ISI marked 1100 volts grade drawn in PVC casing capping on walls/roofs ceiling including replacement of 3 mm thick laminated sheet cover for fixing of switches/sockets etc including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable for earth continuity and connecting to common earth dolly complete all as specified and directed :-
M & L Point wiring with 2.5 Sqmm PVC insulated and unsheatheed single core multi stranded copper conductor ISI marked 1100 volts grade drawn in PVC casing capping on walls/roofs ceiling including replacement of 3mm thick laminated sheet cover with MS box for fixing of switches/sockets etc including 2.5 Sqmm PVC insulated unsheathed stranded copper conductor cable for earth continuity and connecting to common earth dolly complete all as specified and directed :-
(a ) One 3 pin 5 amps switch sockets controlled by one switch piano type SP 5 Amps on a board independent type from switches.
(b) All as per item Ser No 2.07 but 3 pin 15 Amps switch socket complete all as specified and directed
S & F ceiling rose, 3 phase, PVC/ Polycarbonate isolated body complete all as specified and directed
S & F Wall mounted fan of sweep 400 mm including remote complete all as directed (make: USHA/Orient/Bajaj)
S&F Switch piano flush type single pole one way 5 amps complete all as specified and directed
S&F Socket outlet, 5 Amps, 5 pin, flush type complete all as specified and directed.
S & F switch socket outlet 2 in 1, 3 pin, 5 Amps .
S&F Air termination, single pointed, Copper rod 12 dia and 300 mm long including necessary fixing arrangements with mounting plate complete all as specified and directed.
S&F Copper strip 20mm x 3.15 mm complete with saddles, fixing screws for fixing the strip, insulator etc complete all as specified and directed.
S&F test Point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm, drilled and screwed including 3 nos,8 mm dia 25 mm long hex. Head screw with materials complete all as specified and directed.
S & F Chemical Earthing with copper strips including Marconite chemical as used complete all as directed By Eng in charge (Mixing of Marconite3 x25 Kg bags of Marconite Conductive concrete for Earthing 1x 25 Kg bag cement) as per direction of Engineer-in-Charge
M & L for witch flame proof rotary type with termination box in LM6, 16 A, single pole 250 complete all as specified and directed.
S & F flame proof Exhaust fan of confirming to IS 65 complete all as specified and directed.
M & L for LED tube light fitting. 1 x 36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil all as specified and directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreading thickness and consolidated ( punned) upto 180 mm thickness, complete all as specified and as directed.
Supply and Laying Sub-Class old size B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft/loose soil, complete all as specified and directed.
Removing excavated materials (soils) not exc. 50.00 M and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and directed.
Supply and install hi wall split AC units 1.5 ton capacity indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating dual inverter type and EER 3.2.of capacity as shown.
S & F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 140 V to 250 Volt with out put voltage stabilized at 230 Volt with accuracy of +/- 2.5% and of capacity 5 KVA
Supply and fix refrigerators, electric driven (single phase), capacity 310 Litres .BEE 5 star rated
S & Fixing Copper pipe two rune size of 1/4'' and 5/8'' including insulation suitable for Split AC
S&F powder coated sheet metal enclosures MCB DB, double door, single pole and neutral, 4 way 220 volts fitted with bus bar DIN rail neutral link and incoming contact complete all as specified and directed by Engr-in-charge.
S&F MCB SPN 45 Amps breaking capacity 10 KA 240 volts, 'C' series, complete all as specified and directed by Engr-in-charge
S&F MCB SP 20 Amps breaking capacity 10 KA 240 volts, 'C' series, complete all as specified and directed by Engr-in-charge.
S & F Flame proof MCB DB SPN 4 ways 240 volts 50 cycles 1100 volts. complete all as specified and directed by Engr-in-charge
S & F MCB SPN 32 Amps 240 volts 50 hz complete all as directed
S & F MCB SP 5 to 32 Amps 240 volts 50 hz complete all as directed
M/L for Sub Main Wiring with 6 Sqmm PVC insulated copper cable 1100 volts grade stranded copper conductor cable drawn through and including PVC casing capping with all fittings and accessories including PVC box (IS-14772) and 6 Sqmm stranded PVC unsheathed copper cable for earth continuity connected to common earth dolly complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 Amps Make Legrand Cat No 6078 41 or equivalent model in Schenider /ABB
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core including suitable size lug etc complete all as specified and directed by Eng -in- charge.
M & L Tubes, 'light grade' galvanised of dia 25 mm with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Earthing complete with GI Earth plate electric 300x300x3.15 mm buried directly in ground vertically to a depth of not less than 2.25m below ground level with the top edge of earth plate at a depth of not less than 1.5mtr below ground level connected to GI earth lead 4mm dia by means of nuts bolts washers etc made out of galvanised iron and GI wire connected to main switch/ DB board including necessary excavation and earth work PCC (1:3:6) type C1 using 20mm graded stone aggregate earth chamber 40mm thick RCC cover type B1 (1:2:4) B1 using 20mm graded stone aggregate 20mm dia GI medium grade protection pipe upto main switch board etc complete all as shown in electrical plate No 5 of MES Schedule Part I.
Earthing complete with GI Earth plate electric 600x600x6mm buried directly in ground vertically to a depth of not less than 2.25m below ground level with the top edge of earth plate at a depth of not less than 1.5mtr below ground level connected to GI earth lead 4mm dia by means of nuts bolts washers etc made out of galvanised iron and GI wire connected to main switch/ DB board including necessary excavation and earth work PCC (1:3:6) type C1 using 20mm graded stone aggregate earth chamber 40mm thick RCC cover type B1 (1:2:4) B1 using 20mm graded stone aggregate 20mm dia GI medium grade protection pipe upto main switch board etc complete all as shown in electrical plate No 5 of MES Schedule part I.
Supply, fixing and testing FRP solution preparation cum settling tank with lid, port hole, inlet/ outlet/ drain connection, sludge collection facility level gauge etc and fitted with speed reducing motor and SS-316 agitator of 100 ltrs capacity including accessories like lead tubing, connecting nuts, injection check valve, clay weight, ferrules etc complete all as specified and as directed by Engineer-in-Chrage. Make : DECRIN, RMCO CDS-100
S&F Stepped type electronic fan regulator, flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
S&F switch socket combination 2 in 1.3 pin 5/15 Amps flush type universal 240 bolts grade
Supply and fix LED tube light fitting 1x18Watt box type surface mounted 230V, 4 ft etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and including one LED tube, 18W complete all as directed at site complete. Make - Cromptorn Code No LCTLN-18-CDL or equivalent Bajaj/ Havells/Philips
S&F 36W LED 5700K Ultra modern recess mounting luminaire suitable for armstrong grid/OPO ceiling complete with separate electronicdriver & high brightness SMD LEDs fixture size of ceiling 2 x 2ft. Make - Crompton Cat Part No LCTLRTF 6-36 CDL/ Bajaj BCTBLR 36W LED FPCW and equivalent Philips /Havells/ C&S
S&F Factory made vertical type of MCCB DB TPN 4 way, IP-43 made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail, 415 Volts with double door complete as specified and directed. Make : Legrand Cat part No 5077 58 or IndoAsian cat No.812045 or Equivalent from other specified make in PS.
S & F sheet metal enclosure MCB double door (IP-43) for load line DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy surface mounting SPN, 8 way, 240 volt, with 200 amps rated bus bar, stove enameled dust and vermin proof suitable for incorporation of MCB’s and isolator etc complete all as specified and as directed by Engineer-in -charge.
S&F MCB, TPN, 63 Amps, 415 Volt, breaking cap 10 KA; C-series complete all as specified and as directed by Engineer-in-Charge.
M&L submain wiring with two single core PVC insulated unsheathed stranded coppe conductor 4 sqmm (nominal area) drawing through PVC conduit in concealed on wall and 2.5 Sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly (Note : PVC conduit will be measured & paid seperately)
S&F 1100 volts grade heavy duty cable PVC insulated stranded 10 sqmm aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire on twin core cable flat or circular including taking out old existing unserviceable one complete all as specified and directed. Make - havells Polycab/ Richa
S&F 1100 volts grade heavy duty cable PVC insulated stranded 6 sqmm aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension wire on twin core cable flat or circular including taking out old existing unserviceable one complete all as specified and directed. Make - havells Polycab/ Richa
Supply and fixing for 16 Sqmm PVC insulated copper cable 1100 Volts grade stranded copper conductor cable drawn through and including PVC conduit with all fittings and accessories including lug complete all as directed Maek - Richa/ Havells/ Polycab
Supply and fixing TPN change over switch 32 Amps capacity including cables lug etc complete all a specified ands directed. Make - Havells L&T/ Siemen/ Legrand
M.S. Construction
Ms N D Enterpise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .