Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC INDEX NO B 132 HQ ADG P CHENNAI NO 229 ANGAPPAN STREET MITTANAMALLI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.2 L+₹1.4 L (5.58%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹28.1 L+₹2.4 L (9.31%)Rejected-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹33.4 L+₹7.6 L (29.7%)Rejected-AOC | L4 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
21 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai 600 055
REPAIR AND MAINT OF WINDOW/ SPLIT ACs AND OTHER SUMMER APPLIANCES AT AF STN UNDER GE AVADI
2021_MES_461885_1
8848
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer, Avadi
₹78,000
Yes
27 Sept 2021
22 Jul 2021
23 Aug 2021
22 Jul 2021
21 Aug 2021
7 Aug 2021
60 days
Amount
Testing the leakage in system, arresting the leak by vacumising the system, dehydration and charging the refrigerent R-22 /R-32 in to the system including replacement of strainer and capillary tube made out of copper complete suitable for 1.5 Ton Window Air conditioner all as directed by Engr-in-charge.
Testing the leakage in system, arresting the leak by vacumising the system, dehydration and charging the refrigerent R-22 /R-32 in to the system including replacement of strainer and capillary tube made out of copper complete suitable for 1.5 Ton Split Air conditioner all as directed by Engr-in-charge.
All as per the item 2 here-in-before but 2 Ton capacity Air conditioner
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Split type AC, 1.5 ton capacity of any make / model complete all as specified and as directed.
All as per the item 4 above but 2 Ton capacity Split Air conditioner
All as per the item 4 above but 1.5Ton capacity Window Air conditioner
Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Cooling coil suitable for Split AC,1.5ton capacity of any make / model complete all as specified and as directed.
All as per the item 7 above but 2 Ton capacity Air conditioner
Taking down the existing unserviceble Cooling coil and taken on credit and replacing with new Condenser coil suitable for Split AC,1.5ton capacity of any make / model complete all as specified and as directed.
All as per the item 9 above but 2 Ton capacity Air conditioner
Taking down the existing unserviceble Condenser coil and taken on credit and replacing with new Cooling coil suitable for Window AC,1.5ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceble Cooling coil and taken on credit and replacing with new Condenser coil suitable for Window AC,1.5ton capacity of any make / model complete all as specified and as directed.
Removing and pump down the split AC of cap 1.5/2.0 Ton and refixing including shifting the same all as directed by Engr-in-charge.
Taking down the existing unserviceble indoor unit fan motor and taken on credit and replacing with new indoor unit fan motor suitable for Split AC,1.5ton capacity of any make / model complete all as specified and as directed.
All as per the item 14 above but 2 Ton capacity Air conditioner
Taking down the existing unserviceble outdoor unit fan motor and taken on credit and replacing with new outdoor unit fan motor suitable for Split AC,1.5ton capacity of any make / model complete all as specified and as directed.
All as per the item 16 above but 2 Ton capacity Air conditioner
Taking down unserviceable fan motor and Supply and fix new fan motor for 1.5 Ton window AC all as directed by engr-in-charge.
Taking down the existing window type AC, 1.5 ton / 2.0 ton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil, base bottom and fins, with soap water, checking of electrical wiring, ensure smooth functioning and re-install and reconnect the AC unit in its exising location after proper cleaning of the place and testing and commissioning complete all as specified and as directed.
Taking down the existing split type AC, 1.5 ton / 2.0 ton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil base bottom and fins,with soap water, checking of electrical wiring, ensure smooth functioning and re-install and reconnect the AC unit in its exising locations after proper cleaning of the places and testing and commissioning complete all as specified and as directed.
S&F in replacement PCB suitable for 1.5/2.0 Ton AC as per site requirement all as directed
S& F in replacement of copper tubing set 1/4" and 1/2" suitable for Split AC incl NUF insulation and connected accessories complete all as directed
S& F in replacement of copper tubing set 3/8" and 5/8" suitable for Split AC incl NUF insulation and connected accessories complete all as directed
Supply and fix in replacement starting relay suitable for 1.5Ton A/C all as directed.
All as per item No. 24 above but suitable for 2.0 Ton A/C.
Supply and fix in replacement wiring kit suitable for 1.5 / 2.0 Ton A/C all as directed
Supply and fix in replacement running capacitor 36mfd 230/415 Volt all as directed . Make: Keltron/Sarada/Usha/Tibcon.
All as per item No. 27 but 50 mfd 230/415 all as directed .Make: Keltron/Sarada/Usha/Tibcon.
Supply and fixi in replacement starting capacitor 80/100mfd 230/415 Volt
S&F Pvc drain pipe size 15mm / 20mm suitable for A C all as directed
S&F NUF insulation for copper tubing suitable for split AC all as directed
Supply and filling refrigerent R-22, suitable for Window AC/water cooler of any type all as directed
Supply and filling refrigerent R-32 suitable for Split AC/water cooler of any type all as directed
Taking down the existing unserviceble Over load Protector and taken on credit and replacing with new Over load Protector suitable for Window AC / Split AC,1.5ton / 2.0 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceble Thermostat switch and taken on credit and replacing with new Thermostat switch suitable for Window AC / Split AC,1.5ton / 2.0 ton capacity of any make / model complete all as specified and as directed. Make : INFOSS/DANFOSS
Supply and fix for replacement of Remote control sensor and digital device complete set with remote suitable for split type AC, 1.5 ton / 2.0 ton capacity.
Supply and fix for replacement of Air filter suitable for window / Split type AC, 1.5 ton capacity.
Supply and fix for replacement of Front grill suitable for window type AC, 1.5 ton capacity.
Supply and fix for replacement of Oscillating motor / device to change direction of air flow suitable for split type AC, 1.5 ton / 2.0 ton capacity.
Supply and fix for replacement of Magnetic coil suitable for split type AC, 1.5 ton / 2.0 ton capacity.
Taking down the existing unserviceble GI bracket including all accessories and taken on credit and replacing with new GI bracket including all accessories suitable to fix out door unit of split type AC, of any make / model complete all as specified and as directed
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Three phase Package type AC, 5.5 ton capacity of any make / model complete all as specified and as directed.
Testing the leakage in system, arresting the leak by vacumising the system, dehydration and charging the refrigerent R-407A in to the system including replacement of dryer filter complete suitable for Package type Air conditioner all as directed by Engr-in-charge.
Taking down the existing unserviceble Discharge valve and taken on credit and replacing with new Discharge valve suitable for Package type AC 5.5 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceble Suction valve and taken on credit and replacing with new Suction valve suitable for Package type AC 5.5 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceble Coper Condenser coil and taken on credit and replacing with new Copper Condenser coil suitable for Package type AC 5.5 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceble Coper Evoperator coil and taken on credit and replacing with new Copper Evoperator coil suitable for Package type AC 5.5 ton capacity of any make / model complete all as specified and as directed.
Taking down the existing unserviceble blower fan motor and taken on credit and replacing with new blower fan motor suitable for Package type AC 5.5 ton capacity of any make / model complete all as specified and as directed.
Supply and Top up of refrigerent gas R-407A of 5.5 ton package type AC
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for water cooler of capacity 80 ltrs any make / model complete all as specified and as directed.
All as per item No. 50 above but suitable for 120 ltr cap water cooler
All as per item No. 50 above but suitable for 150 ltr cap, water cooler
Taking down the existing unserviceble copper condenser coil and taken on credit and replacing with new opper condenser coil cap 80 ltrs water cooler of any make / model complete all as specified and as directed
All as per item No. 53 above but suitable for 120 ltr cap water cooler
All as per item No. 53 above but suitable for 150 ltr cap, water cooler
Renewal with fabricated sheet metal of base where compressor and condensor are mounted alongwith legs by base plate of sheet metal 2mm thick of size 600mm x 600mm with frame of angle iron 25mm x 25mm x 6mm alround,x 20mm widh legs of mild steel pipe 40mm dia, 150mm long with bottom sealed with MS sheet 2mm thick and spray painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after due preparation of surfaces for water coolers of capacity 80 ltrs / 120 lits / 150 lits complete all as specified and as directed.
Taking down the existing unserviceble condenser fan motor and taken on credit and replacing with new condenser fan motor any cap water cooler of any make / model complete all as specified and as directed
Cutting the suction / discharge tubes of the compressor line and Flushing, vacuuming and charging of water cooler of any make / model with refrigerant gas, after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete of capacity 80 ltrs water cooler all as specified and as directed.
All as per item No. 58 above but suitable for 120 ltr cap water cooler
All as per item No. 58 above but suitable for 150 ltr cap water cooler
Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for water cooler of any make / model / cap complete all as specified and as directed.
Taking down the existing unserviceable short circuited wires and terminal clips and taken on credit and replacing with new wires and terminal clips suitable for water cooler of any make / model / cap complete all as specified and as directed.
Taking down the existing unserviceable PVC water inlet pipe and taken on credit and replacing with new PVC pipe, transparent, heavy duty 20mm dia water inlet pipe for water cooler complete all as specified and as directed.
Taking down the existing unserviceable PVC pipe as drain out pipe and taken on credit and replacing with new PVC pipe, heavy duty 25mm dia drain out pipe laid on walls / floor for water cooler complete all as specified and as directed.
Supply and fix unserviceable Starting Relay suitable for water cooler of any capacity all as directed . (Make : Whirlpool/Renutral/Godrej)
S&F in replacement running capacitor cap 30 Mfd suitable for water cooler of any capacity all as directed(Make : Sharda/Universal/Tibcon)
S&F in replacement starting capacitor cap 60 to 80 Mfd suitable for water cooler of any capacity all as directed (Make : Sharda/Universal/Tibcon)
All as per item No. 67 above but cap of 40 to 60 mfd .
S&F in replacement thermostate switch suitable for water cooler of capacity all as directed. . (Make :Infoss/Renutral/Denfoss)
S&F in replacement OLP suitable for water cooler of any capacity all as directed. (Make : Classic/Renutral/Denfoss)
Supply and fix in replacement new fan motor suitable for water cooler any capacity all as directed. (Make: Frogmaster / Shriram / freeflow
Supply and fix U/S chromiam coated brass bip Tap for water cooler 15mm size, straight type
Supply and fix U/S chromiam coated brass bip Tap for water cooler 15mm size, angle type with round disc
Supply and fix U/S drain tray (stainless Steel) for water cooler of any capacity
Supply and fix U/S 15 mm float valve for water cooler.
Preparation of surface by removing dust, tinkering, applying metal putty wherever necessary and painting with two coats of synthetic enamel paint by spray painting of the Refrigerator 340 ltrs all as specified and as directed.
All as per item No. 76 above but cap of Refrigerator 210 to 285 ltrs .
All as per item No. 76 above but cap of Refrigerator 300to 320 ltrs .
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for digital inverter refrigerator of any make / model and capacity 340 lits complete all as specified and as directed.
All as per item No. 79 above but cap of Refrigerator 300 to 320 ltrs
All as per item No. 79 above but cap of Refrigerator 210 to 285 ltrs
Taking down the existing unserviceable compressor sealed unit by disconnecting the incoming / out going refrigerant lines and taken on credit and replacing with new compressor sealed unit, reconnecting refrigerant lines, detection of leakage and arresting the same by welding / brazing, flushing vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for Deep Freezer of capacity 300 to 320 lits of any make / model complete all as specified and as directed.
All as per item No. 82 above but cap of Deep Freezer 400 to 425 ltrs
Cutting the suction / discharge tubes of the compressor line and flushing, vacuuming and charging of refrigerator / freezer of any make / model with refrigerant gas (R-12/R-404), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / brazing complete Cap of Refrigerator 340 ltrs all as specified and as directed.
All as per item No. 84 above but cap of Refrigerator 300to 320 ltrs .
All as per item No. 84 above but cap of Refrigerator 210 to 285 ltrs .
All as per item No. 84 above but cap of Deep Freezer 300 to 320 ltrs
All as per item No. 84 above but cap of Deep Freezer 400 to 425 ltrs
Taking down the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for digital inverter refrigerator of any make / model and capacity complete all as specified and as directed.
Taking down the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for Deep freezer of any make / model and capacity complete all as specified and as directed.
Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for refrigerator / deep freezer of any capacity any make / model complete all as specified and as directed.
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for refrigerators of any make / any capacity any model complete all as specified and as directed.
Magnetic door gasket suitable for refrigerator of any capacity
Freezer (cooling coil) suitable for refrigerator of any capacity
Freezer door set suitable for refrigerator of any capacity .
Thermostat switch with knob
Relay box type suitable for refrigerator of any capacity .
Relay open type suitable for refrigerator of any capacity .
Timer switch suitable for refrigerator of any capacity .
Blower motor suitable for refrigerator of any capacity .
Running capacitor 4 Mfd suitable for refrigerator.
Door lock with key in duplicte suitable for refrigerator of any capacity .
Pigmy lamp screw / pin type with holder suitable for refrigerator of any capacity .
Ice box tray suitable for refrigerator of any capacity .
Vegetable tray suitable for refrigerator of any capacity .
Bottle tray suitable for refrigerator of any capacity .
Shelves of inner panel suitable for refrigerator of any capacity .
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for Deep freezers of any make / any capacity any model complete all as specified and as directed.
Relay with OLP suitable for Deep freezer of any capacity .
Thermostat switch suitable for Deep freezer of any capacity .
Condensing motor suitable for Deep freezer of capacity 300 lits to 320 lits.
Starting capacitor 40 Mfd to 60 Mfd suitable for Deep freezer of capacity 300 lits to 320 lits.
Running capacitor 4 Mfd suitable for Deep freezer of capacity 300 lits to 320 lits.
Deep freezer door hinges with spring, screw etc suitable for freezer of any capacity .
Hard PVC stand suitable for Deep freezer of any capacity .
Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for voltage stabilizers of capacity 5 kVA / 4 kVA / 3 KVA of any make / model complete all as specified and as directed.
Main transformer
Sub transformer
Transistorised electronic relay.
Electronic PC circuit plate having diodes, condensers etc.,
Voltmeter 0-300 Volts
High / low voltage cut-off relay
Time delay relay
Output terminal contacts
Socket outlet 5 pin 5 / 15 Amps
Disconnecting and dismantling of RO plant of capacity 200LPH/ 250 LPH / 500 LPH etc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed Note:- Spare parts as required shall be measured and paid separately.
Supply only the following spare parts:-
Raw water pump 0.50 HP.
Sand / carbon filter vessel 1054
Coarse sand bag 10 kg as 1 unit
Fine Sand bag 10 kg as 1 unit
Silex 10 kg bag as 1 unit
Pebbles 10 kg bag as 1 unit
Carbon 450 IV 10 kg bag as 1 unit
Multiport valve 20 NB
Dozing pump
20 inch housing filter
20 inch filter spun
20 inch wound
Antiscalant liquid
High pressure pump (CRI) 2-100
40-40 membrane housing
End cup
End cup "O" ring
Saddles and straps
Membrane (Filmtech), (hydro nautics)
Membrane connecter
Auto electric panel
Flow meter 0-600
Flow meter 0-1200
Pressure gauge
UPVC pipe 20mm dia and accessories
Ultra violet media 250 LPH
Clip for Ultra violet media
50 litre tank
Membrane cleaning liquid
Disconnecting and dismantling of RO plant of capacity 15 LPH / 50 LPH etc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed Note:-Spare parts as required shall be measured and paid separately.
Supply the following spare parts.
Carbon granules filter
5-5 membrane and housing assembly 70 gallon per day.
Pressure pump 48 V
Adaptor 48 V
Carbon black filter.
Micron filter
Dismantling and removing of domestic water purifier (Aqua 200) filters fixed on wall and connected to water coolers at various locations, replacement of filters, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed.
M &L for point wiring with 4 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in to and including PVC conduit and conduit accessories controlled by one switch including 4.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed.
Supply & fixing single pole and neutral metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A including taking down the old enclosure. All as directed.
Taking down the existing unserviceable PVC 3 core 2.5 sqmm copper cable and taken on credit and replacing with new PVC 3 core 2.5 sqmm copper cable suitable for Water cooler / Refrigerator / Deepfreezer Make : Havells / Finolex or equivalent complete all as specified and as directed.
Taking down the existing unserviceable PVC 3 core 4 sqmm copper cable and taken on credit and replacing with new PVC 3 core 4 sqmm copper cable suitable for Split AC Make : Havells / Finolex or equivalent complete all as specified and as directed.
Taking down the existing unserviceable MCB SP 5A to 32A and taken on credit and replacing with new MCB SP 5A to 32A suitable for Split AC Make : C&S / L&T / Havells or equivalent complete all as specified and as directed.
Taking down the existing unserviceable Porcelin ICTP 100A Main switch and taken on credit and replacing with new MCCB 3 Pole, 415V fixed type 125A with breaking capacity 16KA with suitable metal encloser complete all as specified and as directed.
Taking down the existing unserviceable switch socket outlet 2 in 1, 3 pin, 5 and 15 A flus type and taken on credit and replacing with new 2 in 1 15A flush type socket complete all as specified and as directed.
Supply and fix U/S 15 A plug top for water cooler, refrigerator, deep freezer
Supply and fix U/S 15A metal glad plug top for Air conditioner.
Fixing only 1.5 ton split AC (with indoor unit and outdoor unit ) connected from indoor unit to outdoor unit with suitable copper tubes including NUF insulation all as directed by eng-in-charge.1.5 ton split AC and connected meterials supplied through under shedule 'B' free for fixing.
M&L Electrical Earthing complete with GI plate Electrode of size 60cm x 60cm x 6 mm thick burried directly in ground vertically at a depth not less than 2.25mtr. Below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. Below normal ground levels, connected to galvanised earth lead with 25 x 4 mm thick GI strip by means of bolts, nuts and washers of galvanised iron, earth lead wire protected by means of 15mm bore dia light grade GI pipe up to switch board/ panel board, all as specified and shown in MES schedule electrical p;ate No - 5 of SSR part I, RCC1:2:4 type C1 40 mm thick cover slab with 6mm dia MS bars at 100mm centre to centre both ways, with 6mm dia MS hook Charcoal dust, salt, funnel for watering complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Galvanised iron strip 25 x 4 mm as earth continuity conductor including fixing arrangement on suitable size insulator complete all as directed.
RK ENTERPRISES
M/s.Sai Agency
SRI VENKATESWARA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .