Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹20.6 L+₹669 (0.03%)Rejected-AOC R O BHARDA KALAN P O TEH AKHNOOR PIN 181201 DISTT JAMMU J K | JAMMU | JAMMU AND KASHMIR | 181201 | L2 | Rejected-AOC FOUND OTHER THAN LOWEST | |
| 3 | L3₹21.0 L+₹33,040 (1.60%)Rejected-AOC | L3 | Rejected-AOC FOUND OTHER THAN LOWEST | |
| 4 | L4₹21.5 L+₹86,599.25 (4.20%)Rejected-AOC | L4 | Rejected-AOC FOUND OTHER THAN LOWEST | |
| 5 | L5₹21.6 L+₹91,979.50 (4.46%)Rejected-AOC | L5 | Rejected-AOC FOUND OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
26 Jan 2021, 6:00 pmClosed
GE of GE (SOUTH) AKHNOOR
GE of GE (SOUTH) AKHNOOR C.O 56 APO
SPECIAL REPAIR TO BLDG NO P-16 AND TR-03, SPECIAL REPAIR TO BLDG NO TR-22 (OR LIVING ACCN) AND SPECIAL REPAIR TO BLDG NO TR-18 AT HAMIRPUR UNDER GE (SOUTH) AKHNOOR.
2020_MES_407745_1
NIT-71
Open Tender
Civil Works
Item Rate
180 days
HAMIRPUR AREA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH AKHNOOR
₹48,000
28 Mar 2021
29 Dec 2020
28 Jan 2021
29 Dec 2020
26 Jan 2021
12 Jan 2021
Amount
SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified.
Dismantling of plain or corrugated AC/steel sheeting, any gauge, thickness, including any pattern roof coverings, complete all as specified and directed by Engineer-In-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-In-Charge.
Dismantling/demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/ steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix (1:2:4), M-15 type B-1 (using 20mm graded crushed stone aggregate), nominal mix, 100mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix (1:3:6) M-10, type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix (1:2:4) M-15, type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), 100mm thick, as in sub base of floors, finish even to recive floor finishes, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix (1:2:4) M-15, type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, plinth courses, apex stones, bed plates, kerbs, mud stops, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix (1:3:6) M-10, type C-2 (using 40mm graded crushed stone aggregate) in surface channels and drains, complete all as specified and as directed by Engineer-In-Charge.
Extra for forming fair finished drain or channel 30 Cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 1.15 here-in-before but except bricks .
Granite (of any type) work (table rubbed and polished), 15-18mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified, complete all as specified and as directed by Engineer-In-Charge.
Providing and fixing everest board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, including powder coated galvanised iron snap grid frame work of main and tee (weight not less than 240gm/Rm), angle (weight not less than 217 gm/Rm), grid size 595x595mm, for false ceiling all as specified, and hangers 6mm dia, galvanised iron (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron wire of 4.0mm dia, length as required at site and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-410 (Gde-E-250) quality-B, complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on any faces of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, on plastered surfaces, preparatory to distempering, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement paint over one coat lime wash, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of distemper oil emulsion, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of cement paint, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of white wash, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (size shall in one length), 18-20mm thick, as in riser of steps, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or back plastering layer of mortar 15mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450x7mm thick, 400x400x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Dura tuff pave-n-park cement concrete coloured tiles size 300mmx300mmx6/7mm, with chequered finish, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over 15mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Taking down shutters of any descriptions area exceeding 1.00 Sqm but not exceeding 2.00 Sqm, complete all as specified and directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix (1:3:6) M-10, type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and glass sheet 3.0mm thick, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge.
Factory made, glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed by Engineer-In-Charge.
Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.
Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed by Engineer-In-Charge.
Factory made solid panel PVC door shutter with wood free EPS, 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame with three Nos of stainless butt hinges of 100mm size and rust proof screws, at site as per specification and drawing, complete all as specified and as directed by Engineer-In-Charge.
Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 200mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge.
Sheet glass, 3.0mm thick, ordinary quality and glazing with oil putty or with wooden beadings, fixing in square not exceeding 0.50Per Square Metre in each pane, complete all as specified and as directed by Engineer-In-Charge.
Galvanised mild steel wire cloth, 0.42 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, , complete all as specified and as directed by Engineer-In-Charge.
Galvanised mild steel wire cloth in repair, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, , complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Floor door stopper of cover plate 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Refixing old steel tubing galvanised, 15mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Refixing old steel tubing galvanised, 20mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe incl 20mm dia PVC float valve with ball and rod, fixing in repairs, complete all as specified and as directed by Engineer-in-Charge.
Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe incl 20mm dia PVC float valve with ball and rod, fixing in repairs, complete all as specified and as directed by Engineer-in-Charge.
Vitreous China wash hand basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia, waste coupling of PTMT (half or full threaded), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to dismantled floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 litres and making good to dismantled/ damaged surfaces, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China bowl urinal flat back, size of 465x355x265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern and flush pipe but including of waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore pipe, fixed in repair, complete all as specified and as directed by Engineer-In-Charge.
Angle valve/ cock, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stop valves (concealed type), cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Swivel over head shower with arms of PTMT any colour for fixing with 15mm pipe, (Minimum weight 40gms), fixing in repairs, complete all as specified and directed by Engineer-In-Charge.
Low density polyethylene (LDPE) pipes of 32mm bore, pressure rating 6.0 Kgf/Sqcm), 900mm long, complete all as specified and directed by Engineer-In-Charge.
Brass chromium plated, tubular towel rail, 20mm dia, D type, 60cm long between flanges, fancy type, complete all as specified and as directed by Engineer-In-Charge.
Sinks with drainage board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Bib taps, long body, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Curtain rod, 20mm dia, mild steel, fancy type, any colour coated with fixing and inlcuing decorative end knobs, fixing brackets, stops, round rings (clamps) to hold the curtain, fixing in repairs with wall plugs and screws, complete all as specified and as directed by Engineer-In-Charge.
PVC kitchen frame of size 18mmx63mm made out of 18mm thick PVC pre-laminated ply coloured and frame shall be fixed with 50mm long steel screw inside using drilling machine and plsatic fasteners, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Kitchen cabinet size 900mmx750mmx600mm, including partitions, shelves and drawers with brass sliding rails, door hanles, door catchers, over all cabinet internally and externally made with both side PVC laminated termite proof board, 18/19 mm thick, ISI marked, having following specifications: (i) Outer frame made sixe 50mmx47mm with same board. (ii) Shutters both side PVC laminated termite proof board, 18/19 mm thick having contineous piano brass hinges of 30mm flap width with one No brass handle of 75mm including brass door catcher of not less than 50mm size in each shutter. (iii) Drawers made of both side PVC laminated termite proof board, 18/19 mm thick including brass handles of front and two sliding rails at sides in each drawer. (v) All cabinets, drawers, frames and boards shall be fixed at site with brass screws and PVC plugs of suitable sizes. Note: (a) Only front diemensions (Length anf Height) at site, shall be measured and entered in MB irrespective of Nos of partitions or drawers. (b) Different No of partitions and drawers may be as per site reqirement with out any extra cost. (c) All labours and materials cost shall be deemed included in quoted rate.
SCHEDULE 'A' PART-II : BOQ OF WORKS FOR E/M WORKS.
Disconnecting the electric connections and taking down main switches, distribution boxes (any type) including MCBs and making good to the disturbed surfaces to match the existing surface, complete all as specified and as directed by Engineer-In-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 2.03 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 2.03 here in before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 4.0 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, of 65x50mm 3 terminals ISI marked, complete all as specified and as directed by Engineer-In-Charge.
T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
MCB, Single Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Ceiling fan, mettalic, sweep 1200mm, five star rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHCES5SWHT48/ Crompton Greaves Entrust 50/ Usha Ergo/ Bajaj Electra 50/ Orient Electric energy star
Exhaust fan, mettalic, sweep 250/ 230mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers etc, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient.
LED tube light fitting, 18 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 18 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Pride Plus Neo LHEXBLP7PN1W018/ Crompton cat part LCTL-18-CDL/ Bajaj product code-12410, luminaire type- BCLSB 18 NW.
Street light fitting, Pressure die-cast IP 66 LED street light, including LED lamps of 30 to 36 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, fixing in repairs, complete all as specified and as directed. Make: Havells cat part No- Endura Pearl SL30WLED757SASYTOPCMP/ Philips ordering code No- 910925863567 (Product Code: 871869637692800)/ Bajaj cat part No- 169913 .
House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified.
Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 2.24 here-in-before but for sub main wiring (in new conduits concealed to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for laying electric cables or foundation of poles etc, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 4.0mm dia GI wire as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Amount of Schedule of credit of for Rs 80,926.00 shall be deducted from quoted amount.
M/S JEEVAN LAL SHARMA
M/s Vishal Engineers
M/s Cosmos Builder and Developer
KRISHNA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .