| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC L1 quoted rates are overall reasonable, Hence Accepted | |
| 2 | L2₹41.1 L+₹2.5 L (6.44%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹41.4 L+₹2.8 L (7.24%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹42.0 L+₹3.3 L (8.64%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹46.2 L+₹7.5 L (19.5%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L5 | Rejected-AOC REJECTED |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
1 Nov 2019, 6:00 pmClosed
GE (NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
SPL REAPIR/RENEW TO EXISTING ELETRIC METERING SYSTEM INTO PREPAID METERING SYSTEM, U/S ELECTRICAL FITTINGS AND CONNECTED WORK AT NCHC POWAI AND PROVISION OF SOLAR WATER HEATER WITH CONNECTED PLUMBING WORKS AT NAVAL HOSPITAL UNDER GE(NW) BHANDUP
2019_MES_287657_1
8766/B
Open Tender
Civil Works
Item Rate
183 days
NCHC POWAI
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in cl D cat a(i),b(i)
9 documents required · 9 mandatory
₹500
GE NW BHANDUP
₹99,000
Yes
13 Mar 2020
5 Oct 2019
5 Nov 2019
5 Oct 2019
1 Nov 2019
19 Oct 2019
7 Oct 2019 - 12 Oct 2019
Amount
S & F of 1000 litres capacity rotational moulded polyethylene water storage tanks (Triple layer, cylindrical vertical with closed top,ISI) hoisted and fixed in position all as specified.Make : Sintex, Polycon
S & F of ball brass valve of size 40mm , high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete
M&L for brick work with sub class B old size bricks and of class designation 35, straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia over, cut to length, bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with an including mild steel wire (annealed) non less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for form work to sides of concrete suspended slabs, edges and struts of rectangular or triangular shape for fair finished flate concrete surfaces , complete all as specified and directed.
M&L for RCC type A1, 1:1.5:3, using 20mm graded stone aggregate as in suspended slabs, edges and strutus etc, complete all as specified and directed. Note : Form work and \reinforcement shall be measured and paid for separately.
Cutting holes for pipe etc through brick walls (superfical area not exc 150Sqm) built in each hole cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required, complete all as specified and directed.
M&L for rendereing 20 mm thick in cement mortar 1:4 in two coats (15+5mm), both coats mixed with water proofing compound @ 2% by weight of cement , surfaces of top layer finished even and smooth (without using extra cement) including necessary scaffolding etc, complete all as specified and directed. Note : WPC will be measured and paid separately as supply only.
Supply only integral water proofing compound, complete all as specified and directed
M&L for preparation of new plastered surfaces of wall and applying two coats of 100% anti fungal acrylic exterior emulsion paint over one coat of primer all as per manufacturer's instrutions including necessary scaffoldings etc, complete all as specified and directed.
M&L cutting and inserting 40x40x40mm tee in existing 40 mm pipe for taking branch Connection complete all as specified and directed
Supply, Install, testing and commissioning of Solar water heater of capacity 500 LPD comprising of (a) Solar panel with Evacuated Tube Collector (ETC) made out of Borrosilicate glass of 1800mm long and 58 mm outer dia individualised V shaped solar reflectors reflect solar radiation falling between the tubes onto the tube to maximise effeciency complete with 4 mm thick toughened glass housed in MS box type made out of precoated steel with protected corner made with specially designed aluminium die insulated with glass wool and rock wool at 50 mm thick at rear side and 25 mm thick at side portion of the box including risers and header made out of copper tubes of suitable size complete all as directed. (b) Stainless steel tank made out of SS 304L(low carbon content) with zing alume outer cladding , horizontal mounting and direct coupling with solar panels includinh High density injected PUF insulation with electrical back up (3KW with thermostat)and necessary control complete Make: RACOLD/TATA POWER SOLAR /VIKRAM SOLAR
S & F of composite Hot water pipe duly insulated with Nitrile insulation of 19 mm and aluminium cladding 50 mm bore
S & F of composite Hot water pipe duly insulated with Nitrile insulation of 13 mm and aluminium cladding 25 mm bore
S & F of composite Hot water pipe duly insulated with Nitrile insulation of 13 mm and aluminium cladding 15 mm bore
M & L of Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors of size 40 mm dia
Material and labour for submain wiring complete with 2X4 sqmm(nominal core) PVC insulated unsheathed 1100 volts grade FRLS cable multi stranded copper conductor single core in PVC conduit of suitable size width complete with 1x4.0 sqmm PVC insulated unsheathed, FRLS green colour copper conductor as earth wire one run of PVC casing caping connecting to earth dolly.(02 run of 4 sqmm and 01 run of 4.0 sqmm measured as 1 run)
S & F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB of rating 20 Amps
S& F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50 mm dia
S& F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm dia
S& F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm dia
S& F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm dia
S&F in repairs of LED batten, light fitting integrated sleek aluminium extruded LED channel with acrylic cover, with and including 20/22 Watt (not less than 20 W) white light and drive, prewired, provision of 0.5 sqmm 3 core flexible copper conductor wire for connecting from ceiling rose, PVC square/round block etc, complete all as specified and directed Make: Philips cat no BN021C LED20S or equivalent in Havells / Bajaj as approved by GE.
S&F in repairs of LED batten, light fitting integrated sleek aluminium extruded LED channel with acrylic cover, with and including 10 Watt white light and drive, prewired, provision of 0.5 sqmm 3 core flexible copper conductor wire for connecting from ceiling rose, PVC square/round block etc, complete all as specified and directed Make: Philips cat no BN021C LED10S or equivalent in Havells/Bajaj as approved by GE.
S&F Ceilling rose 3 terminal PVC/Polycarbonate isolated body all as specified and as directed
Taking unserviciable celling fan and supply and fixing of ceilling fan 1200mm sweep 5 star rating without regulator including provision of 3 core flexible copper wire of size 23/0.0076 from ceilling rose to ceilling fan for making connection etc. complete all as specified and as directed.ceilling fan for making connection etc. Note:old fan shall be deposited to MES Store yard.Make :Bajaj/Orient/Usha
Supply & Fixing, testing of Single Phase Two Wire AC Static Energy (10-60A) Direct Current Class 1.0 Keypad Based Prepayment Electronic Energy Meter with Customer Interface Unit (CIU) and Soft Token Transfer Device (STTD), Comprising of 1 No. Prepayment Meter + 1 No. CIU + 1 No. STTD (Note: The quoted rate shall be deemed to include one year maintenance charge). MAKE : L& T / HPL Model- PTPB1521130000OC01/ Schneider
Supply & Fixing, testing of Three Phase Four Wire AC Static Energy (10-60A) Direct Current Class 1.0 Keypad Based Prepayment Electronic Energy Meter with Customer Interface Unit (CIU) and Soft Token Transfer Device (STTD), Comprising of 1 No. Prepayment Meter + 1 No. CIU + 1 No. STTD (Note: The quoted rate shall be deemed to included for one year maintenance charge). MAKE : L& T / HPL Model- PTPB1521130000OC01/ Schneider
Web based vending software for creation of consumer database, registration of meters, token generation, tariff change, etc. (one time)including training for 2 days to staff.*
Taking Down electrical meters single Phase/3-Phase type including wiring and other accessories as directed by Eng-in-Charge and depositing the same with storage yard of AGE E/M Powai
joshua construction
R J ENTERPRISES
GRAND SERVICES
sapana enterprises
Radha Engineering Services
DHARMESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .