Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC | ₹5.1 L | L1 | Accepted-AOC Work Order Issued To L1 Bidder |
| 2 | L2₹5.4 L+₹24,600 (4.78%)Rejected-Finance | ₹5.4 L+₹24,600 (4.78%) | L2 | Rejected-Finance High Rate Quoted |
| 3 | L3₹8.4 L+₹3.3 L (63.3%)Rejected-Finance | ₹8.4 L+₹3.3 L (63.3%) | L3 | Rejected-Finance High Rate Quoted |
Tender Value
₹8.8 L
EMD Value
₹17,600
Closing Date
25 May 2021, 6:00 pmClosed
City Engineer
Water Work Department Municipal Corporation Rest House, Shyamla Hills, Bhopal Office Telephone No.0755-2701663, 2701669
Mechanised Cleaning and Disinfection of Over Head Water Storage Tanks at Ward No. 1,2,3,4 and 5 Under Zone No. 01
2021_UAD_141962_1
2020110582
Open Tender
Miscellaneous Works
Item Rate
730 days
Bhopal
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹17,600
25 Mar 2022
10 May 2021
27 May 2021
10 May 2021
25 May 2021
10 May 2021
Amount
Cleaning of oht capacity (2.5-5) lac ltr CLEANING OF OHT OF CAPACITY 2.5 LAKH LTR TO 5 LAKH LTR Cleaning of over head water storage tank including chemical treatment using antibacterial agent as per CPHEEO guidelines and relevant is code consisting of following process dewatering of tank by submersible pump de-silting and removing of rest over dirty water up to 100-150 mm in bottom of over head tank and sludge with specials sludge removing pump ,cleaning of walls and ceiling with high pressure jet machine by rotary jet system at 120 kg/sqrcm pressure which dislodge the layer of dirt, algee ,fungus stuck on the surface of tank remaining sludge should than be removed by sludge pumps ,the dirt silt and other material than should be removed by industrial vaccume cleaner to make the surface totally dirt free ,application /spraying of anti bacterial chemical to ensure total sterilization of tank from inside , inside of tank should be further treated with ultraviolet radiator using UV LAMP, complete job work in order to make tank totally clean and bacteria free and safe for storage of drinking water all the above operations should be executed by trained workers and technicians properly dressed with gum boots ,to work as per direction of engg. in-charge all safety measures should be taken in considerations during complete process DVD’S for each tank during cleaning process will be made and submitted after completion of work ,sludge from tank will be tested for chemical and biological test and test reports will be submitted by contractor and date of cleaning along with further date of cleaning is to be painted on two different places near OHT as per direction of engg. in- charge.
CLEANING OF OHT CAPACITY (5-10 LAKH) LTR CLEANING OF OHT CAPACITY (5-10 LAKH) LTR Cleaning of over head water storage tank including chemical treatment using antibacterial agent as per CPHEEO guidelines and relevant is code consisting of following process dewatering of tank by submersible pump de-silting and removing of rest over dirty water up to 100-150 mm in bottom of over head tank and sludge with specials sludge removing pump ,cleaning of walls and ceiling with high pressure jet machine by rotary jet system at 120 kg/sqrcm pressure which dislodge the layer of dirt, algee ,fungus stuck on the surface of tank remaining sludge should than be removed by sludge pumps ,the dirt silt and other material than should be removed by industrial vaccume cleaner to make the surface totally dirt free ,application /spraying of anti bacterial chemical to ensure total sterilization of tank from inside , inside of tank should be further treated with ultraviolet radiator using UV LAMP, complete job work in order to make tank totally clean and bacteria free and safe for storage of drinking water all the above operations should be executed by trained workers and technicians properly dressed with gum boots ,to work as per irection of engg. in-charge all safety measures should be taken in considerations during complete process DVD’S for each tank during cleaning process will be made and submitted after completion of work ,sludge from tank will be tested for chemical and biological test and test reports will be submitted by contractor and date of cleaning along with further date of cleaning is to be painted on two different places near OHT as per direction of engg. in- charge.
CLEANING OF OHT CAPACITY(10-20 LAKH) LTR CLEANING OF OHT CAPACITY(10-20 LAKH) LTR Cleaning of over head water storage tank including chemical treatment using antibacterial agent as per CPHEEO guidelines and relevant is code consisting of following process dewatering of tank by submersible pump de-silting and removing of rest over dirty water up to 100-150 mm in bottom of over head tank and sludge with specials sludge removing pump ,cleaning of walls and ceiling with high pressure jet machine by rotary jet system at 120 kg/sqrcm pressure which dislodge the layer of dirt, algee ,fungus stuck on the surface of tank remaining sludge should than be removed by sludge pumps ,the dirt silt and other material than should be removed by industrial vaccume cleaner to make the surface totally dirt free ,application /spraying of anti bacterial chemical to ensure total sterilization of tank from inside , inside of tank should be further treated with ultraviolet radiator using UV LAMP, complete job work in order to make tank totally clean and bacteria free and safe for storage of drinking water all the above operations should be executed by trained workers and technicians properly dressed with gum boots ,to work as per direction of engg. in-charge all safety measures should be taken in considerations during complete process DVD’S for each tank during cleaning process will be made and submitted after completion of work ,sludge from tank will be tested for chemical and biological test and test reports will be submitted by contractor and date of cleaning along with further date of cleaning is to be painted on two different places near OHT as per direction of engg. in- charge.
CLEANING OF OHT CAPACITY(20-30 LAKH) LTR CLEANING OF OHT CAPACITY(20-30 LAKH) LTR Cleaning of over head water storage tank including chemical treatment using antibacterial agent as per CPHEEO guidelines and relevant is code consisting of following process dewatering of tank by submersible pump de-silting and removing of rest over dirty water up to 100-150 mm in bottom of over head tank and sludge with specials sludge removing pump ,cleaning of walls and ceiling with high pressure jet machine by rotary jet system at 120 kg/sqrcm pressure which dislodge the layer of dirt, algee ,fungus stuck on the surface of tank remaining sludge should than be removed by sludge pumps ,the dirt silt and other material than should be removed by industrial vaccume cleaner to make the surface totally dirt free ,application /spraying of anti bacterial chemical to ensure total sterilization of tank from inside , inside of tank should be further treated with ultraviolet radiator using UV LAMP, complete job work in order to make tank totally clean and bacteria free and safe for storage of drinking water all the above operations should be executed by trained workers and technicians properly dressed with gum boots ,to work as per direction of engg. in-charge all safety measures should be taken in considerations during complete process DVD’S for each tank during cleaning process will be made and submitted after completion of work ,sludge from tank will be tested for chemical and biological test and test reports will be submitted by contractor and date of cleaning along with further date of cleaning is to be painted on two different places near OHT as per direction of engg. in- charge.
GLOBAL INFRATECH AND FACILITIES
Avni Cleaning and Pest Control Services Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .