Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAdmitted-Finance | ₹10.4 L | L1 | Admitted-Finance |
| 2 | L2₹10.8 L+₹39,561 (3.81%)Admitted-Finance | ₹10.8 L+₹39,561 (3.81%) | L2 | Admitted-Finance |
| 3 | L3₹11.4 L+₹1.1 L (10.1%)Admitted-Finance | ₹11.4 L+₹1.1 L (10.1%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | IMPLA GENERAL SUPPLIERS L1 | M/S WATT ELECTRICAL CONTRACTS L2 | M/S TANTRAY ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.00Permanent restoration of 33 KV Shariefabd - Narbal Line. | ||||||
| 2.00 | Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation 410 SP56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 16 | No | 26,000 ₹4,16,000 | 25,786 ₹4,12,576 Lowest | 26,500 ₹4,24,000 |
| 3.00 | Providing and fixing of fabricated GI V cross arm with top bracket, Channel X-arm including belting, clamps and braces angle iron as per site reqirement. | 468 | kg | 130 ₹60,840 | 125 ₹58,500 Lowest | 140 ₹65,520 |
| 4.00 | Providng,Laying,stringing ,tensioning and binding of 100 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any). | 2.5 | Km | 1,20,000 ₹3,00,000 Lowest | 1,21,212 ₹3,03,030 | 1,50,000 ₹3,75,000 |
| 5.00 | Providing and fixing of PG Clamps for 100 mm² ACSR Conductor. | 8 | No | 200 ₹1,600 | 121 ₹968 Lowest | 300 ₹2,400 |
| 6.00 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm, | 45 | No | 650 ₹29,250 Lowest | 777 ₹34,965 | 650 ₹29,250 Lowest |
| 7.00 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting | 12 | No | 400 ₹4,800 Lowest | 777 ₹9,324 | 900 ₹10,800 |
| 8.00 | Providing and fixing of Gavanized Nuts & Bolts with washers of sorts as per site requirements. | 16 | kg | 120 ₹1,920 Lowest | 121 ₹1,936 | 150 ₹2,400 |
| 9.00 | Providing and fixing of Danger Plates with clamps of standard make | 16 | No | 150 ₹2,400 | 555 ₹8,880 | 100 ₹1,600 Lowest |
| 10.00 | Providing and fixing of Anti Climbing Devices with clamps of standard make | 16 | No | 150 ₹2,400 | 555 ₹8,880 | 100 ₹1,600 Lowest |
Tender Value
₹12.4 L
EMD Value
₹24,880
Closing Date
15 May 2026, 4:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II, Rajbagh
Permanent restoration of 33 KV Shariefabd Narbal Line.
2026_PDD_308496_1
STD-II / 09 of 2026-27 Dated 21-04-2026
Open Tender
Electrical Works
Turn-key
Budgam
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, STD-II, Rajbagh,Srinagar
₹24,880
18 May 2026
23 Apr 2026
16 May 2026
23 Apr 2026
15 May 2026
23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Permanent restoration of 33 KV Shariefabd - Narbal Line. | - | - | - | - |
| 2 | Supply and Erection of 11 Mtr. Long Steel Tubular Pole with welded steel base plate (of Designation 410 SP56) and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 16 | No | - | - |
| 3 | Providing and fixing of fabricated GI V cross arm with top bracket, Channel X-arm including belting, clamps and braces angle iron as per site reqirement. | 468 | kg | - | - |
| 4 | Providng,Laying,stringing ,tensioning and binding of 100 Sqmm ACSR Conductor as per REC construction standard (with latest amendments if any). | 2.5 | Km | - | - |
| 5 | Providing and fixing of PG Clamps for 100 mm² ACSR Conductor. | 8 | No | - | - |
| 6 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm, | 45 | No | - | - |
| 7 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting | 12 | No | - | - |
| 8 | Providing and fixing of Gavanized Nuts & Bolts with washers of sorts as per site requirements. | 16 | kg | - | - |
| 9 | Providing and fixing of Danger Plates with clamps of standard make | 16 | No | - | - |
| 10 | Providing and fixing of Anti Climbing Devices with clamps of standard make | 16 | No | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Tendernotice_2.pdf
PDF • 1.58 MB
BOQ_999663.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .