Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Finance 33 PRINCE ANWAR SHAH ROAD KOLKATA | KOLKATA | WEST BENGAL | 700033 | +0.00% | ₹2.0 L | L1 | Admitted-Finance |
| 2 | L2₹2.0 LAdmitted-Finance 19V JHEEL ROAD DHAKURIA KOLKATA 700031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | +1.50% | ₹2.0 L | L2 | Admitted-Finance |
| 3 | L3₹2.1 LAdmitted-Finance | +4.70% | ₹2.1 L | L3 | Admitted-Finance |
Tender Value
₹2.0 L
EMD Value
₹4,000
Closing Date
11 Feb 2026, 2:00 pmClosed
E.E.W.S(S)
WATER SUPPLY OFFICE (SOUTH) BR-X KOL-68
LEAK REPAIRING WORK ON EXISTING WATER PIPE LINE AT 175A,20/21 N.R AVENUE, 27 BLCK-H H.P SARANI, 18,61 P A SHAH RD AND OTHER LOCATION UNDER BR-X.
2026_KMC_995076_1
KMC/WS/EE/S/M/25-26/27/1st Call
Open Tender
MECHANICAL
BR-X
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹4,000
16 May 2026
31 Jan 2026
13 Feb 2026
31 Jan 2026
11 Feb 2026
31 Jan 2026
CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.10 Hire and labour charges for coir rope fencing 25 mm dia rope single on 120 mm dia bamboo posts 1.40 m above G.L and 600 mm below G.L, 1.50 m apart including digging holes complete.
CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.14 Signalling arrangement at both sides of site to avoid any accident during working period 4 nos. red flags during sunlight at 4 corners and 2 nos light (lamp) in other than sunlight.
CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.12 Supplying sign-board made of 25 mm thick sal plank with frame on all side of sal batten 50 mm x 32 mm with nailed on post 3.15m x 100mm x100mm and fitting fixing such with digging holes of dia 300 mm and depth 750 mm in all sorts of soil and repacking and consolidating the gap aroundthe post with cement concrete (1 : 3 : 6) painting 2 coats including cost of nails, bolts and nuts etc. complete in all respect as per direction of theEngineer-in-charge. Payment of concrete and painting to be made separately. (i) 600 mm. x 450 mm. size of board.
CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.13 Hire & labour charges for diesel generating set for lighting including fuel,300M wire, 11 points with 200 Watt bulb with post for hanging & maintaining the same for day & night for the period.
CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.3 Lead jointing to C.I pipes and specials with supply of lead and spun yarn all complete to make the joint water tight at required hydraulic pressure as per specification & direction of the Engineer-in-charge. (Lead shall be supplied departmentally to the Agency at specified Issuerates and cost thereof shall be recovered from the. works Bill of the Agency] Diameter in mm 300mm dia
CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.3 Lead jointing to C.I pipes and specials with supply of lead and spun yarn all complete to make the joint water tight at required hydraulic pressure as per specification & direction of the Engineer-in-charge. (Lead shall be supplied departmentally to the Agency at specified Issuerates and cost thereof shall be recovered from the. works Bill of the Agency] Diameter in mm 100mm dia
CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.3 Lead jointing to C.I pipes and specials with supply of lead and spun yarn all complete to make the joint water tight at required hydraulic pressure as per specification & direction of the Engineer-in-charge. (Lead shall be supplied departmentally to the Agency at specified Issuerates and cost thereof shall be recovered from the. works Bill of the Agency] Diameter in mm 150mm dia
CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for C.I. Spun Pipes (as per IS: 1536) and D. I. Pipes (as per IS: 8329) complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type - 4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 300
CHAPTER - VIII SUPPLYING OF MATERIALS HIRE CHARGES OF MACHINERIES 8.27Hire charges of moveable type mounted earth excavator having minimum cutter size (1.0 cubic meter) & loader size (2.0 meter length x 0.75m width) for cutting & removal of any kind of soil, spoli etc. including cost of fuel, lubricants & manpower etc. in Water Supply Works. [ This item will be operated on prior permission from the concerned SE/Dy. Chief Engineer] For minimum engagement of 8 hrs. In a day
CHAPTER - VIII SUPPLYING OF MATERIALS HIRE CHARGES OF MACHINERIES 8.27Hire charges of moveable type mounted earth excavator having minimum cutter size (1.0 cubic meter) & loader size (2.0 meter length x 0.75m width) for cutting & removal of any kind of soil, spoli etc. including cost of fuel, lubricants & manpower etc. in Water Supply Works. [ This item will be operated on prior permission from the concerned SE/Dy. Chief Engineer] For beyond 8hrs. of working
CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for C.I. Spun Pipes (as per IS: 1536) and D. I. Pipes (as per IS: 8329) complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type - 4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 150
CHAPTER - VII MISCELLANEOUS ITEMS Dewatering by pumps including all leads, lifts and making all arrangements of disposal. where continuous flow of water from a source other than natural or ground water is encountered in case of emergency maintenance works related to leakage. breakage and making wet connections. [Note ;- In case of any other situation demanding such emergency dewatering. use of this item is to be approved by the Superintending Engineer/Tender Accepting Authority. This item shall be executed on the specific direction duly supported by proper clarification of the E.I.C. who will be satisfied in absolute discretion that such work has not been necessitated due to any natural source of water or any fault of the Contractor]
CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC.1.6 Hire and labour charges for shoring work(including necessary close plank walling, framing,Eucalyptus/Jhou bulla piling, strutting etc)complete as per direction of the Engineer-in charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge).(a) Depth upto 1.5 m.
BUILDING WORKS ( C ) Brickworks,Concrete Works etc A. BRICK WORKS 7. Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth
D.I SPUN PIPE 150 MM DIA TYTON JOINT CONFORMING TO IS 8329/200 CLASS K-7 SUITABLE FOR PUSH -ON-JOINT RUBBER GASKET JOINT WITH INSIDE CEMENT MOTOAR LINING AND OUTSIDE BITUMINOUS /SYNTHETIC RESIN COATING COMPATIBLE WITH THE METALIC ZINC COATING AS PER CLAUSE A-8. 150 MM DIA D.I PIPE
CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for C.I. Spun Pipes (as per IS: 1536) and D. I. Pipes (as per IS: 8329) complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type - 4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 100
CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.7 Cutting of C.l/D.I pipes for fitting with pipes and-or specials of similar or dissimilar materials at the time of laying without damaging any part of the required length including taking out of the broken pieces from the trench and restacking the same at the specified location as per direction of the Engineer-in-Charge.D iameter in mm 150mm dia.
D.I SPUN PIPE 100 MM DIA TYTON JOINT CONFORMING TO IS 8329/200 CLASS K-7 SUITABLE FOR PUSH -ON-JOINT RUBBER GASKET JOINT WITH INSIDE CEMENT MOTOAR LINING AND OUTSIDE BITUMINOUS /SYNTHETIC RESIN COATING COMPATIBLE WITH THE METALIC ZINC COATING AS PER CLAUSE A-8. 100 MM DIA D.I PIPE
CHAPTER - VII MISCELLANEOUS ITEMS Supplying including cost of installation of M.S. Patch Clamps suitable for instantaneous repair of horizontal cracks in C.I. Spun Pipes (as per IS: 1536) and D.I. Pipes (as per IS: 8329). The Clamp constitutes of two semicircular halves made out of 5/6 mm thick Steel Plate duly contoured to match the circumference of the pipes. The Clamp should be with suitable rubber lining/ trey so that on fixing over the damaged pipe, it instantly repairs longitudinal cracks or hole in the pipe body. The length of the Clamp should be 300 mm up to 300 mm nominal dia. and 500 mm in case of pipes of larger nominal diameter of pipe. Sealing Rubber Gasket should be of EPDM quality and Nut Bolts should be Zinc coated. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 100
CHAPTER - VII MISCELLANEOUS ITEMS Supplying including cost of installation of M.S. Patch Clamps suitable for instantaneous repair of horizontal cracks in C.I. Spun Pipes (as per IS: 1536) and D.I. Pipes (as per IS: 8329). The Clamp constitutes of two semicircular halves made out of 5/6 mm thick Steel Plate duly contoured to match the circumference of the pipes. The Clamp should be with suitable rubber lining/ trey so that on fixing over the damaged pipe, it instantly repairs longitudinal cracks or hole in the pipe body. The length of the Clamp should be 300 mm up to 300 mm nominal dia. and 500 mm in case of pipes of larger nominal diameter of pipe. Sealing Rubber Gasket should be of EPDM quality and Nut Bolts should be Zinc coated. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 300
CHAPTER - VII MISCELLANEOUS ITEMS Supplying including cost of installation of C.I. Leak Repair Clamps suitable for permanent repair of leakages in Socket / Spigot joints in C.I. Spun Pipes (as per IS: 1536) and D.I. Pipes (as per IS: 8329). The Clamp consists of two Cast Iron Rings supplied in overlapping semi circular halves which compress a specially shaped / contoured rubber gasket made of EPDM quality (IS:5382 Type-4) on the socket face making the Socket / Spigot Joint water right at the operating pressure. The Clamp to be supplied complete with Rubber Gaskets made of EPDM quality and coated Nut Bolts as per manufacturer specification. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 300
CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.4 Excavation of trial pit (3.0 m x 1.0 m x (upto) 3.0 m) for fixing of pumping main, washout line raking every detection against damage of S.W. pipe line electrical cable etc. as underground obstruction including 37.5 mm timber shuttering, earth cutting, dewatering, barricading and back filling etc. as per directionj of E-I-C
Estimated amount
Add: 9%SGST
Add: 9%CGST
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
BOQ_2434909.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid