Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.1 LAccepted-AOC D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹48.8 L+₹2.4 L (5.12%)Rejected-Finance 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹53.3 L+₹6.9 L (14.8%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Not become lowest bidder |
Tender Value
₹48.7 L
EMD Value
₹97,360
Closing Date
28 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Deepak Kumar
Garrison Engineer Jhansi
ADDITION/ALTERATION OF RENOVATION TO BLDG NO NP -13 OLD KALINGA OF 128 ARMD WKSP AND CERTAIN OTHER SANCTINED WORK AT AGE B/R-I UNDER GE JHANSI
2022_MES_568485_1
GE/JHA/TOK/42 OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE Jhansi
₹97,360
Yes
24 Feb 2023
10 Dec 2022
30 Jan 2023
10 Dec 2022
28 Jan 2023
7 Jan 2023
10 Dec 2022 - 17 Dec 2022
Amount
Demolition of brick work built in cement mortar or lime mortar including all quoins arches, pillars etc complete all as specified and directed.
Demolition of Stone sett paving of any description or thickness laid bedded and pointed in any mortar
Taking down cement plaster on brick or stone wall including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for the shafts, well, cesspits, manholes, pier holes, etc n exc 10 Sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m.
M & L Cement concrete in foundations, filling and mass-concrete type D2 1:4:8 (40 mm graded aggregate)
M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement Mortar 1:6. all as specified and directed.
M&L Brick work with subclass ‘B’ bricks, for half brick wall , straight or curved on plan exc 6m mean radius, built in cement Mortar 1:4. all as specified and directed.
M&L cement concrete 75 mm th, type D2 1:4:8 (40 mm graded stone aggregate) in sub base of flooring.
Formwork to sides of Flat & Rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Formwork to sides and soffits of Flat & Rough finished surfaces of concrete floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Formwork to sides of Square & Rough finished surfaces of concret pillars, posts, struts, piers, columns, and stanchions
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Reinforced cement concrete 1:1.5:3 (nominal mix)in:- Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete
Reinforced cement concrete 1:1.5:3 (nominal mix) in:-Columns, pillars, piers, posts and struts
Reinforced cement concrete 1:1.5:3 (nominal mix) in: Beams, cantilevers, bressummers, lintels over 1.5m span
Reinforced cement concrete 1:1.5:3 (nominal mix) in: Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for Rendering 15mm thick in CM 1:4 onfair faces of brick work or concrete surfaces. Finished even and smooth without using extra cement
M&L Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F of false ceiling comperising of 12mm thick gypsum board including GI frame work for seamless ceiling made of GI perimeter channel 0.55mm thick with two unequal flange of 20and 30mm and web of 27mm fixed to surounding wall using nylone sleeves and screws at 450mm centre/ intermediate channel 0.9mm thick having two equal flange of 15 mm each and web of 45 mm suspended from soffits at approx 900mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kerved web of 50mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm c/c including two coats of plastic emulsion paint, complete all as specified and directed.Make India gypsum/ Gyproc / Lafarge.
S & F 1.25mm th Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in osition as indicated,complete: gear operated type with chain wheel and hand chain
S & F Safety lever locks mild steel with 4 levers for rolling shutters
S & F Ball bearing for rolling shutters
M & L Powder coated (minimum thicknessof powder coating 50 micron) Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M & L Powder coated (minimum thicknessof powder coating 50 micron) Anodised aluminium door shutters,aluminium section weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws tower bolt, hydroulic door closer and all neccessory fittings, etc. complete all as specified
M & L Powder coated (minimum thicknessof powder coating 50 micron) Anodised aluminium window and ventilator shutters, side hung or sliding type type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1no.) all neccessory fittings, etc. complete all as specified
M & L 2mm th Plain colour PVC sheet fixed or laid on to flush/ Alu doors by using rubber based adhesive, supplying & fixing at site as per specification
S & F 4mm th Sheet glass,ordinary quality frosted, on one side and glazing with oil putty in square n exc 0.5 sq. m in each pane
Framed work such as grills,gratings, etc.. with ends of barsshouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L 30mm th Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.
Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hold fast, hinges, lock strike plate, etc., complete, as specified,supplied and fixed
S & F Aluminium alloy, anodised,sliding door bolt300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
M&L for 100 mm butt hinges stainless steel medium weight approved make ISI marked
S&F 125 mm aluminium alloy handles, cast type anodised all as specified.
S&F150mm aluminium anodised barrel tower bolts of extruded section and fixed.
Preparation of New or previously untreated Surfaces and applying Two coats of Synthetic enamel paints of any description, not otherwise descri-bed over 10cm width or girth
M&L preparation of newly plaster surfaces and applying two coats of oil bond distemper (OBD) over a coat of pink primer all as specified
M&L perparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of primer all as specified and directed.
M&L excavation over area not exceeding 1.50m in depth and getting out in for any type of soil , all as specified and as directed by Engr-in-charge
M&L excavation over area exceeding 1.50m but not exceeding 3.00m in depth and getting out in for any type of soil , all as specified and as directed by Engr-in-charge
M&L plain cement concrete 1:2:4 Type B2 using 40mm graded stone aggregate as in flooring as sub base of floor
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius, built in CM 1:4, Pointed flush as work proceed, Complete all as specified and as directed.
M&L 20mm thick rendering on fair faces of brick or concrete surfaces in CM 1:3 finished even and smooth without using extra cement, using integral water proofing compound, Complete all as specified and as directed by Engr-in-charge.
Supply only water proofing compounding
M & L for precast cement concrete 1:2:4 type B-I ( using 20mm graded aggregatesas) as in cover slabs (foe manholes etc) , chullah hoods , chajjs, shelves and similar articles with plain faces, set in cement mortar 1:6, Complete all as specified and as directed by Engr-in-charge.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick surface horizontal or sloping , rough finished surface of concrete; complete all as specified and directed by Engr-in-charge.
M&L for use and waste of formwork to edges of concrete flats, openning in floors and roofs etc; 10cm wide but not exceeding 20cm wide and sides of RCC/PCC bands in wall , horizontal or sloping and similar work exceedind 10cm wide but not exceeding 20cm wide, suuface flat for rough finished surface of concrete; complete all as specified and directed by Engr-in-charge.
M&L for cast iron soil, waste and vent pipes, in any length with or without ears with cement joints , laid in trenches or in floors.
M&L for CI 100mm bends (any radious) , diminishing pieces or trapers(larger bore measured).
M&L for TMT bars 6 to 8mm dia in reinforcement , cut to length, bent to shape,required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia(annealed) complete all as specified and directed by Engr-in-charge.
M&L for Removing excavated material exc. 50m upto 100m and depositing where directed at a level n exc 1.5 m above the starting point.
M&L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in surface channel of drain complete all as specified and as directed by Engr-in-charge.
M & L for cement concrete 1:2:4 type B-0 ( using 12.5mm graded aggregatesas) as in coping etc , incl form work if required Complete all as specified .
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement , including forms , moulds, mitred/stopped ends etc.
M&L for 15 mm thick rendering in CM (1:6) on fair faces of brick work finished even and fair complete all as specified and directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections including fittings.
Taking up or down 20 mm bore steel tubing and connections, including fittings.
S & F in repair 15 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors.
S & F in repair 20 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting, reconnecting and re-fixing in position of exc. 250 litres & not exc. 500 litres capacity of tanks,
S&F in repair Vitreous China wash basin, white, flat back, size 580x450mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling,including PTMT PVC connection 600mm complete all as specified and directed.
Supply and Fix in repairs 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed.
M & L for Non- skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles invertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles with and including 10 mm thick rendering in CM (1:4) for receiving the tiles, complete all as directed.
Taking down eaves gutter and rain water pipes including all fittings any size and pattern.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trench.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trench.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal.
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal.
S & F PVC Floor trap of 75 mm outlet with grating including jointing to waste pipe in run lead.
S&F in replacement of 1st quality vitreous china squatting pan Orissa pattern of size 580x440 mm, white colour with integral foot rests water closet including flush pipe but exluding flushing cistern, duly fixed in lime concrete bedding and making good of floor surface, complete all as directed.
S&F SS grating of squre/round shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and incl fixing with CM to floor/nahani traps etc, complete all as directed.
S & F in repairs 15 mm bore Bib taps, cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S & F in repairs 15 mm bore stop/angle cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S & F in repairs 15 mm bore concealed type stop cock fancy type,chromium plated with long sank crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repair of PVC waste pipe 32 mm dia 750 mm long suitable for wash hand basin & urinal, complete all as specified and directed.
S&F in replair of waste coupling, chromium plated (half or full threaded), 32 mm dia size, complete all as directed.
S&F in repair of PVC connection 450 x 15mm dia PTMT (PVC), complete all as directed.
S&F in repair of towel rail 20mm dia 600 mm long and wall bracket made of cast copper alloy, chromium plated, complete all as directed.
S & F in repairs 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) area exc 1.5 sqm but not exceeding 4 sqm each including cutting holes in brick/ stone wall built in cement / lime mortar, embedded portion exc half brick but n.exc one brick for inserting new hold fast and making good the disturbed portion/surfaces, in CM 1:3 complete all as directed.
Taking down shutters of any description exceeding 01 Sqm and not exc 02 Sqm each, complete all as specified and directed.
S&F of Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood coloured PVC sheet and edges, reinforced with MS square tube, as specified in SSR Part-II 2010 (Section 8, on Page no - 175), complete all as directed.
S&F factory made solid PVC moulded with partical board core door shutter 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick Wooden texture moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing, complete all as specified and directed.
S&F of 100 mm size butt hinges, extruded aluminum alloy with galvanized mild steel pin type B-21 anodized complete.
S&F of aluminium alloy anodized sliding door bolt 200mm length with hasp staple and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all specified and directed.
S&F of 150mm aluminum handle cast type anodized complete all specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in padding levelling etc and roof kerbs, complete all as directed.
M&L for 10 mm thick rendering in CM (1:4) mixed with water proofing compound @ 0.20 Ltr/bags on roof surface when concrete is green, complete all as specified and directed (Note:- WPC shall be measured and paid separately)
Spreading and leveling of soft/loose soil in floor in layers n exc. 25 cm thick including well ramming watering as required.
M&L 25 mm thick cement concrete in flooring type Bo, 1:2:4 (12.5mm graded aggregate)
M&L 75 mm thick cement concrete type C2 1:3:6 in plinth protection finished even and smooth without using extra cement including forming joints and filling with bituminous filler material.
Rendering 10 mm thick on fair faces of brick or concrete surfaces (for top surface of RCC roof slab) in cement mortar 1:6 mixed with liquid WPC 200ml per bag of cement for finished even and smooth without using extra cement.(Note :- WPC will be measured and paid separately).
M&L Rendering in two layer on fair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with liquid WPC @ 200 ml per bag of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 smooth without using extra cement. (Note:- WPC will be measured and paid separately).)
Rendering 5 mm thick on fair faces of brick or concrete surfaces (for ceilling surfaces ) in cement mortar 1:4 mixed with for finished even and smooth without using extra cement.
Supply only Liquid water proofing compound
Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
S&F 15mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S&F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S&F for 15 mm bore concealed stop/angle cock CP fancy type with long shank and cup screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and directed
S&F 15mm bore body bib tap CP fancy type cast copper alloy with crutch of butterfly handle, screwed down, high pressure for iron pipe or for brass ferrule
S & F 15mm dia pillar taps cast copper alloy type
Supply and fix Towel rail 600 mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. M S tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement.
M&L for 100 mm butt hinges stainless steel medium weight approved make ISI marked
S&F 125 mm aluminium alloy handles, cast type anodised all as specified.
S&F150mm aluminium anodised barrel tower bolts of extruded section and fixed.
S&F steel ventilator with top hung shutter including hinges, handle and steel peg stay complete .
S&F 3.00mm thick figured glass, pin head type and glazing with oil putty in square n exec 0.5 sqm in each pane
S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, complete all as specified and directed. Make : Sintex / Vectus / Supreme
S&Ffor 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed.
S&F Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests incl PVC (SWR) P trap 110 mm dia.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (including bolts, PVC (SWR) P trap 110 mm dia, Jet spray and all other connected items).
S&F PVC valveless, syphonic action type, flushing cistern 10ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets
S&F Vitreous China urinal half stall type white (excluding Flushing cistern, flush pipe and waste pipe).
S&F PVC flexible waste pipe suitable for wash hand basin & urinal
Supply and fix urinal spreader of stainless steel for fixing with 15 mm dia pipe (Min weight 60 gms)
S&F 75mm PVC (SWR) vent cowl
Cutting into existing manholes for connecting new drains pipe of internal dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required
M&L for 150 mm dia salt glazed stoneware drain pipe laid in trenches and jointed ( including hunching , benching, and pcc bed 1:4:8)as specified.
M & L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for for the following internal dia of pipes :-
M&L for 150x100 mm dia salt glazed stoneware gully trap, square or round mounted, type "P" as specified.
M&L for hardcore of gauge not exc 63mm deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as in sub base etc complete all as directed.
M&L for sand filling under floor or in foundation including watering and consolidation etc complete all as directed.
M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment etc complete all as directed.
M & L, Cement concrete in mass concrete 1:3:6 Type C2(using 40mm graded stone agg) as in fdn, filling complete all as specified and as directed.
Demolition of cement concrete incl (un-reinforced) in ground floor and paving not exceeding 15cm thick (below or above ground level) built in cement mortar, complete all as specified and directed.
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M&L point wiring for one light point with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc controlled by one switch complete all as specified and directed by Engineer-in-Charge. Note : 1. In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the ISI Marked PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion. 2. No cutting & chasing shall be done on ceiling surface for laying PVC conduit for ceiling fan point wiring etc, hence the PVC casing & capping or surface conduit will be used for the same. 3. In place of terminal box on stone wall, PVC gang box/rectangular box for mounting switches/sockets/regulators with back and front cover will be used.
All as per item No. 2 above but for Lamp holder point controlled by one 6 Amp switch one way complete all as specified and as directed.
All as per item No. 2 above but for one ceiling fan controlled by one 6 Amp switch one way complete all as specified and as directed.
All as per item No. 2 above but for one exhaust fan controlled by one 6 Amp switch one way complete all as specified and as directed.
All as per item No 2 here in before, but for one Switch socket 6 Amps, 2-in-1 on same board complete all as specified and as directed
All as per item No. 2 above but for one 6 Amps, 2-in-1 switch socket out let flush type on the independent board complete as directed.
All as per item No. 02 here-in above but with 2.5 Sqmm copper conductor cable along with one run of 2.5 Sqmm copper conductor cable green in colour for continuous earthing for One 16Amps socket point on the independent board controlled by one switch complete all as specified and directed by Engineer-in-Charge.Make: Conduit-AKG/ Atul/ Kalinga/Modi/Precision/Modi Wire - Havells/ Polycab/ Finolex / Anchor
Supply and fix in replacement ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
Supply and fix in replacement switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA/ SSK
Supply and fix in replacement socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
S&F, in repalcement, of Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
S&F, in repalcement, of Socket, 6 pin, 16 Amp, , 240 volts, complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
S&F, in repalcement of angle/batten type Lamp holder, metal cased, bakelite body, 240 volts, complete all as specified and directed.
Supply and fix in replacement switch type electronic fan regulator rotary type in 5 steps, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.Make : Standard / Indo Asian / L&T / Havells Note: (i) MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge.
Supply and fix in replacement MCB distribution board, SPN, 6 way in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.Make : Standard / Indo Asian / L&T / Havells Note: (i) MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge.
Supply and fix in replacement MCB distribution board, TPN 4Way in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: (i) MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge. Make : Standard / Indo Asian / L&T / Havells
S&F in replacement MCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.Make : Standard / Indo Asian / L&T / Havells
S&F in replacement MCB SPN 40 amps 240 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.Make :
S&F in replacement MCB SP 06 to 32 amps 240 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
S&F in replacement Mini MCB SP 25 amps 240 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
S&F in replacement of MCB protected modular type AC/Geyser box complete with and incl 6 pin socket, plug top, modular cover plates, mini MCB SP 25 Amp capacity, fixed on concealed modular type metal flush box of suitable size, complete all as specified and directed.
Supply and fix in replacement LED batten with CRCA sheet steel body box type pre-wired suitable for and including provision of 1x20 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.
S&F of surface mounting LED light fitting 10 watt (2 feet long), decorative ultra slim type, with inegral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal with twin core, PVC insulated, PVC sheathed flexible copper cable of suitable size, complete all as directed.
Taking down existing sub main wiring of aluminium / copper of 4/6/10sqmm size incl all accessories complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering etc, complete all as directed.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge for the following sizes:- Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length (ii) Five runs of copper cable and one run of PVC conduit shall be measured as one unit length (iii) In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion as directed.
2x6 Sqmm + 1x6 Sqmm
2x4 Sqmm + 1x4 Sqmm
Taking down Exhaust fan of any size carefully, dismantling blades and Cutting and removing of old burnt/damaged winding, cleaning of slots and other parts and rewinding the exhaust fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling and testing for satisfactory performance and refixing after repair in its existing or new location and connecting up including provision of cable from ceiling rose or connector to exhaust fan and testing for satisfactory functioning complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement of capacitor 4mfd, 240V with complete connection all as directed.
Supply and fix in replacement ball bearing suitable for exhaust fan of any size complete all as specified and directed.
Supply, installation, testing and commissioning of step down transformer out door type suitable for plinth mounting complete with standard accessories/fittings suitable for HT 11KV 3 Phase and LT 433 volts 3 phase 4 wire , Dyn-11, copper wound, with off load tap changer having voltage variation of ±7.5% in step of 2.5 % continuous rating of capacity 160 KVA with temperature rise shall not exceed 45° C for transformer winding and 40° C for top oil complete conforming to IS 1180 (Part 1) : 2014 Energy Efficiency Level - 3 for transformer including necessary suitable size PCC plateform and comrrising of following fittings :- (a) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing. (b) Lifting lugs/hooks . (c) Rating and terminal marking plate. (d) Silica gel breather . (e) Drain - cum - sampling valve (3/4)" nominal thread with plug (f)Thermometer pocket with dial type thermometer. (g) Oil filling inlet pipe with plug. (h) Conservator with oil level gauge. (j) First fill of oil up to appropriate level as recommended by manufacturer with fresh new oil. (k) Type of connection arrangement : MS cable termination box on LT side and open bushing on HT side.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply, laying, testing & commissioning of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS 7098 (Part-II) complete all as specified and directed. Note :- Excavation, earthwork, sand Cushioning, Cable covers, pipe for cable protection to be measured and paid separately.
Supply, laying, testing & commissioning of Power Cables, Aluminum Stranded Conductor 300 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
All as per item No. 173.00 here-in-before but of size 185 sqmm, 3.5 core
All as per item No. 173.00 here-in-before but of size 70 sqmm, 4 core
All as per item No. 173.00 here-in-before but of size 50 sqmm, 3.5 core
All as per item No. 173.00 here-in-before but of size 16 sqmm, 4 core
Supply and spread M-sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed. (Note: Punned down thickness only shall be measured for the purpose of payment)
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Supplying and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines / cables and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
Supply and fixing of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
Design, Fabricate, Supply, Installation, Testing & Commissioning of outdoor type dust proof & vermin proof cubical panel board compartmentalized with separate bus bar and cable alley chambers suitable for 3 phase, 4 wire, 415 volts, 50 Hz, Ac supply system as per latest IS/IEC standards & regulations, factory fabricated in an approved factory (manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3.15mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mm x 50mm x 6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1800mm x 1500mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity complete all as specified and directed :-
Note : (i) Factory made name plates with feeder names/ Bldg Nos shall be fixed on relevant incomer/outgoing MCCB doors. (ii) The contractor shall submit set of all drawings of the LT Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing.However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
Design, Fabricate, Supply, Installation, Testing & Commissioning of intdoor type dust proof & vermin proof cubical panel board compartmentalized with separate bus bar and cable alley chambers suitable for 3 phase, 4 wire, 415 volts, 50 Hz, Ac supply system as per latest IS/IEC standards & regulations, factory fabricated in an approved factory (manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 2.00mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mm x 50mm x 6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1500mm x 1300mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity complete all as specified and directed :-
Note : (i) Factory made name plates with feeder names/ Bldg Nos shall be fixed on relevant incomer/outgoing MCCB doors. (ii) The contractor shall submit set of all drawings of the LT Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing.However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
Supply and erection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 mtr long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band/ strips (Make : 3M or equivalent ) of 5 cm wide in Green (02 Nos ) & White (01 No) colour shall be provided at a height of 1.25 mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole complete all as specified and directed. Note :- Excavation and concrete shall be measured and paid separately under relevant items of this BOQ.
Supplying, Installing, Connecting and testing of 11 KV 200 Amps triple pole gang operated air break switch having 12 Nos post insulator with earthing switch rotating type for horizontal/ vertical operation mechanically operated 3 rows type mounted on insulator (including insulators) and steel frame with operating mechanism consisting of operating rod of 25mm bore medium grade GI pipe of suitable length to operated from ground level including locking arrangement with pad lock of godrej make with three Nos of keys including 11 KV swing out explusion fuses (drop out type) of 10 Amps complete all as specified and directed.
M&L for lighting arrestors non linear type with all fitting distribution class, discharge capacity 65 kilo Amps, current rating 5 KA suitable for 11000 volts complete connecting with ACSR jumpers from LA to air brake switch with PVC sleeves complete all as specified and directed.
Supply and fix of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
Supply and fix MCB distribution board, TPN, 4 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fix MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
Supply and fix MCB 63A, 10 KA, TPN, 'C' curve, 415 V, 50 Hz complete all as specified and directed.
Supply and fix MCB 32A, 10 KA, TP, 'C' curve, 415 V, 50 Hz complete all as specified and directed.
Supply and fix MCB 32A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
Supply and fix MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with one number 32 A rated mini MCB TP and 32 A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed.
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with one number 20 A rated mini MCB SPN and 20 A rated 2 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed.
Supply and fix of 70 Watt LED flood light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including surface mounting using adjustable MS cradle of thickness 5 mm provided with the fixture complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED street/security light fitting 70 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
Supply, fixing and testing ceiling fan of 1400mm sweep, 240 Volts, single phase, 50 Hz, 3 blades, double ball bearing, 5 star BEE rating connection up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 sqmm from ceiling rose / connector, including extra GI / MS pipe down rod, as per site requirement (approximate length 01 Mtr) complete all as specified and directed.
Supply and fixing ceiling fan regulator electronic step type 240 Volts, 50Hz, 100W, ISI marked with valid CML No. and connecting up complete all as specified and directed.
M&L for sub main wiring along with earth wire with 2runs x 1.5 sqmm(Ph & N) + 1run x 1.5 sqmm(earth wire) FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ celing / floor etc complete all as specified and directed. Notes: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.
M&L for sub main wiring along with earth wire with 2runs x 2.5 sqmm(Ph & N) + 1run x 2.5 sqmm(earth wire) FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ celing / floor etc complete all as specified and directed. Notes: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.
M&L for sub main wiring along with earth wire with 4 runs x 4.00 sqmm(Ph & N) + 1run x 4.00 sqmm(earth wire) FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ celing / floor etc complete all as specified and directed. Notes: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply and fix of Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, brown, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix of Stay assembly with 16mm dia stay rod and all accessories as shown in electrical plate No. 1 complete all as specified and directed by Engineer-in-Charge. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately)
Supply and fix of Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed by Engineer-in-Charge.
Supply and fix of Galvanized stay strand, 7/3.15mm including proper tightening to required tension complete all as specified and directed by Engineer-in-Charge.
Supply and fix of ACSR conductor for HT/LT overhead line and proper stringing to required tension and sag including binding with new aluminium binding wire of suitable size complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling of steel poles/struts of any size complete all as specified and as directed.
M&L for dismantling of ACSR conductor or AAC conductors of any size complete all as specified and as directed.
M&L for dismantling of cross arms of MS channel or angle sections etc complete all as specified and as directed.
M&L for dismantling of insulators of any type and any size etc complete all as specified and as directed.
Supply, installation, testing and commissioning of air cooled split type air conditioner of 2.0 TR capacity comprising of one indoor and one outdoor unit, wall mounted type, 100% copper, comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 volts AC, single Phase, 50 Hz, having either Five Star rating or inverter technology with three star, with and including inlet / outlet copper pipe for refrigerant between indoor & outdoor unit and flexible copper wire of suitable size as recommended by manufacturer, complete all as directed. Note : The cost of making hole / opening for passing of inlet / outlet copper pipes and electrical cord and making good of surface as original by plastering / applying putty / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
Supply and fix in replacement of recessed mounted LED panel light 2'x2' size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for Amstrong / grid false ceiling complete fix fixing accessories including taking down existing unserviceable light fitting of any description complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC 1:2:4 Type B1 (20mm graded stone aggregate) including necessary form work for DG set foundation complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .