Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-Finance | ₹15.1 L | L1 | Accepted-Finance ACCEPTED |
| 2 | L2₹15.4 LRejected-Finance | ₹15.4 L | L2 | Rejected-Finance REJECTED |
| 3 | L3₹15.6 LRejected-Finance | ₹15.6 L | L3 | Rejected-Finance ACCEPTED |
Tender Value
₹15.1 L
EMD Value
₹30,281
Closing Date
27 Jan 2026, 4:00 pmClosed
EXE.ENGINEER BED
EXE.ENGINEER OFFICE LOUIS JUBLEE COMPLEX,DARJEELING
CONSTRUCTION OF TOILET PROTECTION WALL APPROACH FOOTPATH AND STORE ROOM AT LODHOMA BAZAR COMMUNITY HALL DARJEELING GTA
2026_GTA_986696_1
NIeT-35/2025-26 Dated-10/01/2026OF
Open Tender
CIVIL WORKS
120 days
Darjeeling
EMD,BID CAPACITY,DECLARATION FORM X Y,NIET,TENDER FORM 2911.ii
3 documents required · 3 mandatory
₹1,005
₹30,281
3 Feb 2026
13 Jan 2026
29 Jan 2026
13 Jan 2026
27 Jan 2026
13 Jan 2026
Earth work in excavation of foundation trenches or drains,in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches,levelling, dressing and ramming the bottom,bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
Labour for laying 150 mm to 200 mm boulder soling including rough `-- Do -- -- Do - without rolling but including ramming.
Cost of Stone Boulder 150 mm of N. Bengal variety delivered and stack at site
Ordinary Cement concrete ( mix 1:2:4) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.24.423 (ii ) River Bazree
Ordinary Cement concrete ( mix 1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.24.423 (ii ) River Bazree
Reinforcement for reinforced concrete work in all sorts of structures including distribution of bar, stirups,binders etc.initial straightening and removing of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction.(a) For works in foundatio n, basement and upto roof of ground floor/ upto 4m i) Tor steel / Mild steel
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge
125mm thick brick work with 1st class bricks in cement mortar(1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar, including rounding off corners or chamfering corners as directed and recking out joints or roughening of concrete surface.(ii) (a) with (4:1) cement morter 20 mm thick plaster 144.60 Sq.M 247.20 35745.12 (ii) (b) with (4:1) cement morter 15 mm thick plaster
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected up to three decimals).d) Sal : Local.
35mmthickfactorymadeSolidpanelPVCDoorshuttermadeoutofsinglepieceextrudedsolidPVCprofiles,5mm(±0.2mm) thick,havingstyles&rails(exceptlockrail)ofsize95mmx35mmx5mm,outofwhich75mmshallbeflatand20 mmshallbetapered(onbothside),havingonesidethicknessof15mmintegrallyextrudedonthehingesideoftheprofileforbetterscrewholdingpower,including reinforcingwithMStubeofsize40mmX20mmx1mm,jointsofstyles&railstobemitredcut&jointwiththehelpofPVCsolventcement,selfdrivenselftappingscrews&M.S. rectangular pipes bracket of size190mmX100mmof cross sectionsize35mmx17mmx1mmateachcorner.Singlepieceextruded5mmthicksolidPVCLockrailofsize115mmx35mmx35mm,outofwhich95mmtobeflatand20mmtobetaperedatbothends,having15mmsolidcoreinmiddleofrailsectionintegrallyextruded, fixingthestyles&railswiththehelpofsolvent andselfdrivenself tappingscrewsof125mmx8mm, includingproviding5mm SinglepiecesolidPVCextrudedsheet insertedinthedooraspanel,allcomplete as per manufacturer's specification and direction of Engineer-in-charge.
M.S.gateofJail type asper approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars orangles. M.S. sheet (not less than 14 gauge) gussets, cleatsetc.includingnecessaryriveting,bolting,welding, lockingandhanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Supplying,fittingandfixingwindowsandventilatorswithorwithoutintegratedgrillsconformingtoIS10381975andmanufacturedfromrolledsteel sections conforming to IS7452-1974withnon-frictionprojectingtype,boxtypehinges,glazingclips, lugslockingbracket, handle plate etc, including hoisting in position, straightening if required, fixinglugsincementconcrete(1:2:4)withstonechips20 mmdowncuttingholesandmendinggooddamages tomatchwith existing surface complete in all respect excluding glazing.
ApplyingInteriorgradeAcrylicPrimerofapprovedqualityandbrandon plastered or cencrete surface old or new surface to receiveDistemper/Acrylicemulsionpaint including scrapingandpreparingthesurfacethroughly,completeaspermanufacturer'sspecificationandas per direction of the EIC. (In Ground Floor)
ApplyingExteriorgradeAcrylicprimerofapprovedqualityandbrandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterior emulsionpaint includingscrapingandpreparingthesurfacethroughly, completeaspermanufacturer'sspecificationandasperdirectionofthe EIC.
SupplyingbestIndiansheetglasspanessetinputtyandfittedandfixedwithnailsandputtycomplete. (Inall floorsforinternalwall&upto6m height for external wall) (i) 3 mm thick (weighing 7.4 kg/Sq.m)
M.S. structural works in roof trusses with tubular sections conforming to IS: 806- 1957 & IS: 1161- 1958 connected to one another with bracket,gusset,cleats as per design,direction of Engineer-In-Charge complete including cutting to requisite size. fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957 haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section. consumables such as electrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc.(Payment to be made on the basis of calculated weight of structural tubular members as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with the weight of finished structural members. The rates are considere d for a height of erection 8m./ 2nd. floor leves from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m. or part ther of.
Supplying,fitting&fixingZnAlalloy(55%Al&45%Zn) coating of 150 grams per sq. metre (followed by colour coatedonbothside) steelsheetworkhavingminimumyieldstrengthof550Mpaoftrapizoidalprofileofapprovedmake(excludingthesupportingframework) fittedandfixedwith 55mm&25mmself tappingscrew,EPDMWasher16mmdia&3mmth.washeretc.completewith150mmendlapandonecorrugationminimumsidelap.(Payment to be made on area of finished work).
Galvanised iron sheet eaves gutter fitted and fixedwithnecessary50mmX6mmM.Sflatbarclampsbenttodesign,bolts,nuts,washersetc.complete.Eavesguttermadeof0.63 mm. sheets.(300mm End lapping)
Supplying, fitting&fixing1st qualityCeramic tiles inwallsand floors tomatchwith theexistingwork&4nos. of key stones (10mm) fixedwitharalditeat thebackof each tile&finishing the jointswithwhite cementmixedwithcolouring oxide if required to match the colour of tiles including rougheningof concrete surface, if necessaryorby synthetic adhesive & grout materials etc.
Supplying, fitting&fixing1st qualityCeramic tiles inwallsand floors tomatchwith theexistingwork&4nos. of key stones (10mm) fixedwitharalditeat thebackof each tile&finishing the jointswithwhite cementmixedwithcolouring oxide if required to match the colour of tiles including rougheningof concrete surface, if necessaryorby synthetic adhesive & grout materials etc.
18mm. to22mm. thick, kotastoneslabset in20mmthick(avg) cementmortar (1:4) in floor, stair&lobby including pointingincementslurrywithadmixtureofpigmentmatching the stone shade, including grinding&polishing as perdirectionofEngineer-in-chargetomatchwiththeexisting work. [Slurry [email protected]/[email protected] kg/Sq.m]
Earth work in excavation of foundation trenches or drains,in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches,levelling, dressing and ramming the bottom,bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
Ordinary Cement concrete ( mix 1:2:4) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.24.423 (ii ) River Bazree
Reinforcement for reinforced concrete work in all sorts of structures including distribution of bar, stirups,binders etc.initial straightening and removing of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction.(a) For works in foundatio n, basement and upto roof of ground floor/ upto 4m i) Tor steel / Mild steel
Plum concrete work with 40% cement concrete with 30 mm down graded stone metal and 60% stone boulder of size 150mm and above,placed in position as directed excluding shuttering if any.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge
Construction of Septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (4:1) including two 560 mm dia. R.C.C. manhloe cover of approved make supplied, fitted and fixied in the top slab with necessary fittings, 19 mm thick cement plaster(4:1) with neat cement finish to the internal surfaces and 12 mm thick plaster(4:1) to outside wall upto 200 mm below G.L. floor finished with 25 mm thick grey artificial stone including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavating earth in all sorts of soil, shoring, bailing and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tank with earth, removing spoils, fliing up the chamber with clear water, removing foreign materialsfrom the chamber and including constructing attached inspection pit as per approved dawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 5% by weight of cement, complete in all respect as per directon of Engineer-in-For 50 users.with Bazree (N.B.Variety).(SAIL/TATA/RINL)Charge.
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing).580 mm X 440 mm.
Supplying fitting and fixing CPVC(chlorinated poly vinyl chloride) pipes of approved make conforming to IS:15778:2007 with all necessery acceessories,specials.. 15mm
Supplying fitting and fixing CPVC(chlorinated poly vinyl chloride) pipes of approved make conforming to IS:15778:2007 with all necessery acceessories,specials.. 20mm
Supplying PVC water storage tank of approved quality with closed to.. 2000litre capacity
Suplying fitting and fixing G.I gravity operated water tap for public use.. 15mm dia
Supplying fitting and fixing alloy iron with brass spindle bib cock/stop cock of…
Labour for laying 150 mm to 200 mm boulder soling including rough `-- Do -- -- Do - without rolling but including ramming.
Cost of Stone Boulder 150 mm of N. Bengal variety delivered and stack at site
Ordinary Cement concrete ( mix 1:2:4) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.24.423 (ii ) River Bazree
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge
Ordinary Cement concrete ( mix 1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.24.423 (ii ) River Bazree
Reinforcement for reinforced concrete work in all sorts of structures including distribution of bar, stirups,binders etc.initial straightening and removing of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction.(a) For works in foundatio n, basement and upto roof of ground floor/ upto 4m i) Tor steel / Mild steel
Fixing post of iron or precast concrete by digginghole in theground(inallsortsofsoil)andembeddingthesamebypackingthe holewithcementconcrete(1:3:6) (withjhamakhoa.ForPurulia,Bankura and Darjeeling Hill by Pakur Variety, Local Black Hard Stone&Bazree respectively) and finishing the top surface to regular shape (as directed) with 15 cm cement plaster (1:6)complete, includingthecostof concrete,plasteretc.but excludingthe cost of the post :
cost of MS angle for facing 50x50x6
Supplying, fitting, fixing,Chain link fencingof approvedquality with R.C.C posts wooden posts or iron posts by means of galvanised"C" clips togridof horizontal strands of galvanised high tensile spring steel wire of 12 S.W.Gwhich have to be tensionedand fixed to thevertical postsbymeansof galvanised special clips, bolts and nuts etc.
Supplying galvanised staples fitted and fixed complete.
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.06 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2408906.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid