Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | L1 | Accepted-AOC Rates quoted reasonable | |
| 2 | L2₹29.8 L+₹3.4 L (13.0%)Rejected-Finance WARD NO 07 WARD NO 07 THANA PARA NALHATI BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L2 | Rejected-Finance Rates quoted higher side | |
| 3 | L3₹29.9 L+₹3.5 L (13.3%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L3 | Rejected-Finance Rates quoted higher side | |
| 4 | L4₹30.3 L+₹3.9 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Rates quoted higher side | |
| 5 | L5₹32.1 L+₹5.7 L (21.7%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L5 | Rejected-Finance Rates quoted higher side |
Tender Value
₹39.6 L
EMD Value
₹79,200
Closing Date
11 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) PANAGARH
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
SPECIAL REPAIRS TO PLUMBING SYSTEM WITH RELATED CIVIL WORKS AND SOME ELECTRICAL WORKS IN CERTAIN SMQS AT AF SINGARSI UNDER AGE(I) AF SINGARSI
2022_MES_513113_1
82359/SING/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE(I) AF SINGARSI
Please refer tender documents
9 documents required · 9 mandatory
₹500
AGE(I) AF SINGARSI
₹79,200
Yes
22 Apr 2022
10 Mar 2022
13 Apr 2022
10 Mar 2022
11 Apr 2022
24 Mar 2022
10 Mar 2022 - 24 Mar 2022
60 days
Amount
Note : Prior to commencement of the subject works, the contractor needs to submit valid Electrical License in the name of himself/them self or Agreement with agency having valid Electrical License alongwith Agency's Electrical License to the Accepting Officer for his approval through GE. In absence of such documents, no work will be executed at site and to be treated as defaulter on the Contractor's part . In addition, Supervisor for execution of electrical works employed by the Contractor shall posses Supervisory Certificate of competency issued by concerned State Govt/Union Territory and the Worker/Tradesman for execution of Electrical Works must hold necessary permit issued by concerned State Govt/Union Territory.
Cutting holes into or through stone walls not exc 150Sqcm, built in cement mortar or cement lime mortar and walls of cement concrete complete all as specified and directed by Engineer-in-Charge. .
Cutting existing 20mm bore steel tubing for alterations or additions (Each cut measured) complete all as specified and directed by Engineer-in-Charge. .
Taking up or down 15mm bore, steel tubing and connections, including cleaning for re fixing or removal to storecomplete all as specified and directed by Engineer-in-Charge. .
Taking up or down 20mm bore, steel tubing and connections, including cleaning for re fixing or removal to store complete all as specified and directed by Engineer-in-Charge. .
Supplying and laying of CPVC pipes 16mm outer dia pipes of SDR 11 & Plain, CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of CPVC pipes 25mm outer dia pipes of SDR 11 & Plain, CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Demolition of cement concrete (Un-reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by the Engr-in-Charge.
Material and labour for PCC (1:2:4) type B0 (using 12.50mm graded stone aggregate) as in roof padding complete all as specified and directed by the Engr-in-Charge..
Material and labour for 15 mm thick rendering in cement mortar 1:4 on external faces of brick wall or concrete surfaces, finished the surfaces even and smooth without using extra cement with using approved LWPC as per manufacturer instruction complete all as specified. Note: LWPC shall be measured and paid separately )
Cleaning the Roof surfaces and applying bitumen primer @ 0.30 KG/Sqm, providing and laying 3mm thick APP based polymeric membrane minimum weighing 3kg/sqm, reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm), having softening point not less than 800 N/Sqcm, tearing strength of 180N, with minimum of 10cm side laps and 15cm end laps, laying by application of torch, and Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed by the Engr-in-Charge..
Supply only liquid water proofing compound as per manufacturer instruction.
Dismantling PVC water storage tanks of capacity exc.250 liters and not exc. 500 liter and removing from site complete all as specified and directed by the Engr-in-Charge..
Dismantling PVC water storage tanks of capacity exc.500 liters and not exc. 1000 liter and removing from site complete all as specified and directed by the Engr-in-Charge..
Supply and fix 1000 liters Rotational moulded polye thylene water storage tanks with tripple layered white colour with ISI marked including plastic lid cover, (cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight -210gms all as specified in SSR Part- I and directed by the Engr-in-Charge.
All as per item No. 15 here -in -before but except water tank but fixing only including refixing in position, cleaning and reconnecting complete all as specified and directed by the Engr-in-Charge. Note: Tank obtained from item No. 13 & 14 shall be reused.
Supply and fix 25mm bore dia, CPVC Ball valve (Gate valve) quarter turn screwed both ends for CPVC pipe or for unionsand fixed complete all as specified and as directed.
BLANK
Supply and fix in repairs 15mm bore dia, Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articlesstaircases, landing, chajjas and similar suspended work complete all as specified and directed by the Engr-in-Charge.
Material and labour for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by the Engr-in-Charge..
All as per item No. 21 here- in -before but except stone complete all as specified and directed by the Engr-in-Charge.
Extra over stone walling for hammer dressing to face stones and dressing of faces beds and joints, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface not exc. 20mm, complete all as specified and directed by the Engr-in-Charge.
Material and labour for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copings of masonary wall, including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by the Engr-in-Charge..
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing unserviceable material outside MOD area complete all as specified and directed
Material & Labour for rendering 15 mm thick in cement mortar 1:4 on fair faces of stone surfaces and finishing the surfaces even and smooth without using extra cement (incl all necessary scaffolding lifting arrangement for external surfaces) complete all as specified and directed.
Material & Labour for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Material & Labour for preparation of newly plastered surface and applying two coats of cement base paint complete all as specified and directed by Engr-in-Charge.
Material & Labour for preparation of newly plastered surface on ceiling and applying three coats of white wash complete all as specified and directed by Engr-in-Charge.
INTERNAL ELECTRIFICATION: Taking down carefully point wiring (light, fan, buzzer, socket) complete including fittings such as ceiling rose, pendents, regulator, socket & fittings, etc removing from site and making good disturbed surface of walls / floors etc complete all as specified and as directed.
Material & Labour for point wiring with single core, PVC insulated unsheated stranded copper conductor, FRLS cable 1100 volt grade of size 1.5 sq mm (nominal area) in and including PVC casing caping 25/20mm width with 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth dolly including PVC/wooden switch board on existing wall surface for one light / ceiling fan/exhaust fan/bell point controlled by one number one way switch and making good disturbed surface to match with existing surfaces/wall complete all as specified and directed by Engr-in-Charge.
All as per item No.31 here-in-before but for one 5 pin socket outlet 5 Amps on independent board cables 1.5 sq. mm size complete all as specified and directed by Engr-in-Charge.
All as per item No.31 here-in-before but for one 5 pin socket outlet 5 Amps on independent but below the swith board of light point in the same verticle panel board cables 1.5 sq. mm size complete all as specified and directed by Engr-in-Charge.
All as per item No.31 here-in-before but for one 5 pin socket outlet 5 Amps on on the same board with other switches, complete all as specified and directed by Engr-in-Charge.
All as per item No.31 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 4 sq. mm size FRLS copper cable and 4 sq. mm size FRLS copper cable for earth continuity wire, complete all as specified and directed by Engr-in-Charge.
Supply & fix switch piano flush type, single pole one way, 5 Amp complete all as specified and directed by Engineer-in-Charge.
Supply and fix socket 3/5 pin , 5 Amps, flush type complete all as specified and as directed.
Supply and fix switch socket combination, 5 pin, 5 Amps, with flush type universal complete all as specified and directed.
Supply and fix switch socket combination, 5 pin, 5/15 Amps, with flush type universal complete all as specified and directed.
Supply and fix ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed by Engr-in-Charge.
Supply and fix bell buzzer, Ding Dong AC. 230 volts, single pole all as specified and directed by Engr-in-Charge.
S & F Sheet metal enclosure for DB's where MCBs/ Isolators to be used, 240 volts, single pole and neutral, 8 way with built in bus bar including taking down old unserviceable DB's and making good disturbed surface to match with existing colour complete all as specified and directed by Engr-in-charge.
Material and labour for MCCB, four pole, 415 Volt, overload adjustable 0.63- 0.8 -1 x in short circuit fixed 63 Amps breaking capacity 25 KA complete all as specified and directed by Engr-in-charge.
Material and labour for MCB, SP, 240 Volt, 40 Amps and B' series breaking capacity 10 KA 'ISI Marked' complete all as specified and directed by Engr-in-charge.
Material and labour for MCB, SP, 240 Volt, 6 to 32 Amps and 'C' series breaking capacity 10 KA 'ISI Marked' complete all as specified and directed by Engr-in-charge.
Material and labour for MCB, SPN, 240 Volt, 40 Amps and 'C' series breaking capacity 10 KA 'ISI Marked' complete all as specified and directed by Engr-in-charge.
Supply and fix ceiling fan regulator, electronic stepped type, solid state, 100 watt, 240 Volts complete as specified and directed by Engr-in-Charge.
Supply and fix Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete as specified and directed by Engr-in-Charge.
Supply and fix in repair for wall mounted LED, 2 feet, 10 watt fittings with high diffuser, driver holder extruded aluminium heat sink provided for energy efficient heat dissipation and integrated electronic incl all accessories and lamp, internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete as specified and directed by Engr-in-Charge.
Supply and fix in replacement of existing energy efficient tubelight fitting of capacity 20 Watt suspended type/ wall mounted type, complete convert to LED fittings with twin core twisted flexible copper conductor cable with suitable size complete as specified and directed by Engr-in-Charge.
Supply and fixing sub main wiring with two run of single core 6 Sqmm, PVC insulated unsheathed stranded cable, (FRLS) copper conductor drawn through PVC casing caping with all fittings including 6 Sqmm PVC insulated, unsheathed, single core, copper conductor as earth wire and including PVC casing caping after taking out old unserviceable wiring complete and including PVC casing caping complete all as specified and directed by Engr-in-charge. Note : (i) Two run of single core cable 6 sq mm and one run earth wire 6 sq mm with PVC casing caping will be measured as one length.
M/S New Builders Corporation
M/S MBS TRADING CO
P .BANERJEE AND CO
M/S KUMAR AVINASH
LALAN SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .