Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹18.3 L+₹3.1 L (20.4%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommended due to not enlisted in Cat b(iii) |
Tender Value
₹15.2 L
EMD Value
₹30,440
Closing Date
23 Feb 2022, 6:00 pmClosed
GE EAST AGRA
GE East Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt 282001
REPAIR MAINTENANCE AND UPGRADATION TO HT ELECTRIC METERS CONTROLS FOR VCB AND MISC WORKS AT 33 11 KV MRS UNDER GE EAST AGRA
2021_MES_494306_2
9414/E8
Open Tender
Civil Works
Item Rate
360 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹30,440
Yes
17 Mar 2022
21 Jan 2022
25 Feb 2022
21 Jan 2022
23 Feb 2022
29 Jan 2022
Amount
Supply of sustainability management software place from suitable to meet the following requirements for one year package. Make of software:- Logic technologies or as approved by GE.
( A ) Requirement: Administrator Interface and User Managementa) a. Ability to provide a login interface to the administrator to interact with user management module. Administrator should be able to. Add Users, b. Delete Users, c. Define roles of User, d. Edit User information/role. b.Ability to support the role based access of the information. It should have feature to define the privileges of user to access the limited information based on his/her role. c. Ability to maintain history of changes made in User profile and role updates. d.Ability to provide the feature to search Users based on their name, roles etc. e.Ability to provide a User Hierarchy view of Users for better management. f.Should support that user account creation , group membership management , password reset capabilities for a given group or groups of users can be delegated to any nominated user. g.Should support Read Only Domain controllers for enhanced security.
( B ) Requirement: Device installation and remote provisioning a.Should have capability to cater installations of devices at different locations. b.Should have device provisioning capability - by which various parameters of devices could be configured at installation time and thereafter remotely. c.Ability to maintain history of installation and provisioning. Software should record and display the installation status.
( C ) Requirement: Device Data Acquisition System (DDAS) a. Should be able to provide Device Data Acquisition module to meet following: Predefined time interval data acquisition from instruments/sensors automatically Historical data acquisition from instruments /sensors Supervisory function i.e. processing, monitoring, analysis and diagnostics Data exchange Storage of data. b. Should be capable of collecting data using any of the available Communication technologies like GPRS, EDGE,LTE, WiFI, Ethernet . The system shall cater to at-least any two of the said technologies. c. Should process and store following kind of Data: 1. Energy Meter/ Sensor data 2. Alert / Power Event / Status data 3. Device diagnostic data 4. SMS commands 5. Audit track of all changes wherever implemented.
d. Should be capable to handle data from pre-installed measuring devices and support future expansion -Hardware agnostic. e.Should support the future expansion so that water and Enviroment data can acquire without any major change-Protocol agnostic . f. Should be able to publish data at pre-defined time interval, system should be able to collect this data regularly from all the devices. On Demand Device Data – Requisition process initiated by software system, which should allow user to demand current data from the device. g.Should have capability to configure the data collection frequency. DDAS functionality shall be independent of data collection frequency of measuring devices. h.Should have facility to enter manual readings & associated data for taking care of device change, but only with appropriate user authentication, security , approval and audit trail. i. Should support import of device data from external sources in industry-standard formats like ASCII, CSV, XML etc. (Standard exchange formats)
( D ) Requirement: Dashboards a.Predefined dashboards for various use roles. b.User should be able to create custom dashboard for himself. c.Admin user should be able to create custom dashboard for other users/all users.
( E ) Requirement: Reporting a.Provide predefined reports. b.Provide the ability to save reports. c.There should be centralized reporting functionality that gives users a single place for locating the latest reports, spreadsheets, or key performance indicators. d.Should Provide for Reporting wherein reports can be published through a variety of mediums like web application, client application, mail, ftp folder, mobile handhelds etc. Should support multiple formats like html, PDF, XML and other custom formats as out of the box. e.Reporting services should provide for adhoc reporting in web version. Should provide an intuitive zero-client, browser-based user interface. Book marking facility for web reporting. f.Should provide customization features for reporting where user can filter on various parameters to be reported on the screen. g.Should allow Conditional highlighting to provide visual highlight information inside tables and graphs depending on conditions defined. h.Should allow Creation of filters to control data displayed on a report. And allow Parameters passing to the reports at run- time. i.The system should provide capability to create live, interactive BI portals that assemble and display business-critical information from disparate sources, using integrated BI capabilities such as dashboards, scorecards, key performance indicators, and business data connectivity technologies.
( G ) Requirement: Architectural Requirements a.Bidders should clearly describe how the solution will follow the architecture principles as specified in the RFP including SOA, Open Standards, availability, scalability, security, Usability, Smart Clients and Disaster Recovery. The Solution shall be architected and designed using the principles of Service- Oriented Architecture (SOA) and Enterprise Architecture, comprising of Process Architecture, Information & Data Architecture, Application Architecture, and Technology & Security Architecture.
( H ) Requirement: Warranty a.The products proposed in the solution must have clear roadmap for next 5 years. The updates and patches for the products must be provided for 5 years from the Go Live Date and Patches and Updates of proposed software must be provided free of cost for this duration.
( J ) Requirement: Training a.Training for five days for functional operational for two persons shall be provided by company at site.
( K ) Requirement : IoT Gateway a. Shall support RS 485 and Ethernet communication along with GPRS/LTE and Wifi/Ethernet connectivity. Shall support end to end encryption of data for security.Shall support Data logging incase of no communication for one month.
Installation, testing and commissioning of software system alongwith necessary connection, wiring with existing metering system and IOT cloud connector including configuration and testing complete to make fully monitoring the functional requirement as per below item no 3 : -
Supply, fix in repair IOT cloud connector suitable for above mentioned software including necessary set for the functional energy monitoring or as recommended by software provider complete in all respect all as specified and directed.
Supply, fix in repair Smart Energy meter with accuracy Class 1S with RS485 digital communication port complete in all respect all as specified and directed by Engineer in Charge as per Schinieder Cat Pt No METSEEM6400NGRSCL1 or equivalent ABB/L&T
Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 100+50/5-5 A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 21.1 KV for 1.0 second complete all as specified and directed.
virendera singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .