Loading
Loading…
Loading…
Tender Value
Refer Docs
Closing Date
26 Mar 2024, 3:00 pmClosed
PR & CC
CANOPY AT SZ AND SWZ
2300010889-HD-09050
5100010889
Open Tender
Unknown (Unspecified Location)
₹0
Exempted
26 Mar 2024
1 Mar 2024
26 Mar 2024
26 Mar 2024
4 Mar 2024 - 15 Mar 2024
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | SUPPLYING&TRNSPT,FBRCTN 7750-GMO SOUTH ZONE | SUPPLYING&TRNSPT,FBRCTN 7750-GMO SOUTH ZONE — UPPLYING, TRANSPORTING, FABRICATING, ERECTINGIN POSITION IN POSITION OF PRE- FABRICATED STEELSTRUCTURES AT ALL ELEVATIONS FOR CA PY USINGSTRUCTURAL STEEL SECTIONS ISMB/ISMC/ISACONFORMING TO IS:2062 AND IS 226 , INCLUDINGCUTTING, WELDING OR BOLTING, SUPPLY FBOLTS/NUTS/WASHERS ETC., COMPLETE AS PER DRAWINGSINCLUDING SURFACE PREPARATION AND APPLYING ONECOAT OF ZINC PHOSPHATE PRIMER FORE ERECTION,ONE COAT AFTER ERECTION AND TWO COATS OFSYNTHETIC ENAMEL PAINT AS PER SPECIFICATION AFTERERECTION AND ALL MATERI S AND LABOUR COMPLETE. (NO WELDING IS PERMITTED AT SITE). THE RATE QUOTEDSHALL INCLUDE COST OF BOLTS, NUTS, WASHERS,WELDING AN ELECTRODES AND ANY OTHER CONSUMABLESREQUIRED FOR COMPLETING THE WORK. NUT BOLTS SHALLNOT BE CONSIDERED FOR PAYMENT.THEORETICAL W HTOF STEEL SECTIONS SHALL BE CONSIDERED FORPAYMENT..(.(NO MEASUREMENT SHALL BE TAKEN FORNUT,BOLT,WASHER SPLICE PLATE & GUSSET ATE) " | - | Metric ton |
| 2 | SUPPLY&FIXING,CLIPPON | SUPPLY&FIXING,CLIPPON — upply and fixing Clippon Roofing System: | - | square meter |
| 3 | PROVIDING&FIXING,FALSE | PROVIDING&FIXING,FALSE — roviding & fixing false ceiling system of Trac150 F exterior grade or approved equivalent of0.5mm thick galvanised steel with st e enameledcoil coated finish inter locking ceiling panels,carriers, suspension system and edge closure asper the following spe fication. Supplying andinstallation of exterior grade 150 F ceilingsystem comprising of 150 mm x 17 mm deep panelsroll formed ut of 0.5 mm galvanised steel withstove enameled coil coated finish. The panelsshall be pre-treated and coil coated on one side in manufacturers standard colour shades asapproved by the Architect/ Engineer in charge.The rear side of the panel shall be give a coatof primer and a wash coat while the finished sideshall be given a coat of primer and finish colourcoat in polyster paint or a min. dry filmthickness of 20 microns, fixed on to the rollformed carriers 34.5 mm x 488 mm deep out of 6 mmthick Galvanis steed with prongs to hold panelsin the module of 150 mm at maximum 1.2 mts. C/C. The carriers to be suspended from roof truss rigid suspension angles as per manufacturer'srecommendation. Panels shall be supplied incustom length upto maximum of 5 mts. ob alsoincludes providing ceiling flashing using factoryformed 0.5 mm thick Polyster coated galvanisedsteel material. Rate sh l be includingproviding flashing to cover gap if any betweenilluminated banding and false ceiling. | - | square meter |
| 4 | SUPPLY AND FIXING FOR | SUPPLY AND FIXING FOR — upplying and fixing 20 SWG GI sheet faciaincluding painting with one coat of zinc chromateprimer and two coats of 1 st quality s theticenamel paint on front side . Necessary faciaframework for fastening the sheet to the canopysecurely shall be paid separa ly. | - | square meter |
| 5 | PROVIDING&FIXING,AL | PROVIDING&FIXING,AL — roviding and fixing 2 mm thick Aluminum SheetGutters of required shape in slope with 40 mm x3 mm MS. Brackets at 1000 mm maxim spacing and8 mm dia G.I. J or L hooks, boltsand nuts, GILimpet and bitumen washers, providing nut boltjoint , sealing the jo ts with silicon sealanttesting the gutter for leakage by filling wateretc. Complete.(Refer attached Drawing .Forallowable tol ance refer to IS codes | - | meter |
| 6 | PROVIDING AND FIXING FOR | PROVIDING AND FIXING FOR — ROVIDING AND FIXING 6"" DIA PVC PIPES OF 6KG/SQCM OF APPROVED MAKE AS PER IS 4985 FOR RAINWATER PIPES INCLUDING ALL FITTINGS LIK BANDS ,SHOES ETC., MS FABRICATED BRACKET AS PERREQUIMENT ETC. ALL COMPLETE AS DIRECTED BY THEEIC." | - | meter |
| 7 | SUPPLY&FIXING,80W LED | SUPPLY&FIXING,80W LED — 0 W LED FITTING AS MENTIONED IN IS STANDARDS IS16101 TO 16107:SUPPLY AND FIXING OF 80 W LEDHOUSED BY SINGLE PIECE PRESSURE DIE ST ALUMINUMBODY, RECESS MOUNTABLE FITTING WITH GUARANTEEDBURNING HOURS OF 50000 .MAKEPHILIPS/HAVELLS/BAJAJ/WIPRO/OSRAM/CROMPTO GE/BEVER INNOVATIONS. IP PROTECTION OF MINIMUM IP 65 ANDABOVE, SUITABLE FOR CANOPY LIGHTING AT RETAILOUTLETS (PETROL STATION) HE BIDDER SHOULDSUBMIT COPY OF CERTIFIED PHOTOMETRIC REPORT ASPER IESNA LM-79(APPROVED METHOD FOR THEELECTRICAL AND PHOTOMETRI MEASUREMENTS OFSOLID-STATE LIGHTING PRODUCTS) FROM A UL/ ERTL/ERDA OR ANY NABL ACCREDITED LABORATORY TOVALIDATE THE PHOTOMETRI CLAIMS AS & WHEN ASKEDBY HPC. A MINIMUM 3 YEARS WARRANTY FROMMANUFACTURING DEFECTS FOR THE LUMINAIRE BYMANUFACTURER.I) WITH GH LUMEN EFFICACY LEDSFROM CREE, SEOUL SEMI-CONDUCTOR, LUMILED PHILIPS,OSRAM, NICHIA (JAPAN), TRIDONIC (AUSTRIA), GE ANDBRIDGE X . EFFICIENCY OF MORE THAN 90 LUMENS PERWATT . LEDS USED IN THE FIXTURE SHOULD BE FROMTHE SAME BIN AND CERTIFIED AS PER LM-80 ( SNA:APPROVED METHOD FOR MEASURING LUMEN MAINTENANCEOF LED LIGHT SOURCES AND LED LUMEN DEPRECIATIONTIME TO L70 BASED ON LM-80 D A). BY ANY UL/ ERTL/ERDA OR ANY NABL ACCREDITED LABORATORY TOVALIDATE THE PHOTOMETRIC CLAIMS AS & WHEN ASKEDBY HPC.II) BOTTOM PEN ABLE FOR EASYMAINTENANCE.III)HIGH QUALITY POLYCARBONATE OPALDIFFUSER FOR OPTIMUM UNIFORMITY AND GLARE FREELIGHT OUTPUT.I GENERAL ELECTRICAL PROTECTIONAGAINST HIGH VOLTAGE AND SURGES UP TO3 KVV)POWER FACTOR > 0.95VI) RANGE ALLOWED FOR TOTALSYSTE WATTAGE 80 W WITH +2W OR -2W VII) DRIVEROPERATING VOLTAGE RANGE: 140 V- 270 V VIII)OPERATING TEMPERATURE 0 TO +45 DEG CENTIGRAD VIII) CRI MORE THAN 70 IX) COLOURTEMPERATURE5650K?500K (TO BE MENTIONED IN LM 79CERTIFICATE) X)WIDE BEAM ANGLE FOR SPREAD OF IGHT 120 DEGREES OR MORE XI)LUMINAIREPERFORMANCE COMPLIES TO IS10322 (PART 5/SEC 3) &IEC 60598-1,IEC 60529, ROHS" | - | Each |
| 8 | SUPPLY AND LAYING OF | SUPPLY AND LAYING OF — upply and laying following size PVC insulated,sheathed, armoured cable of approved makeconforming to IS 1554:Part 1:1988 4CX2 SQMMCOPPER CABLE | - | meter |
| 9 | SUPPLY,END | SUPPLY,END — D TERMINATION END TERMINATION OF FOLLOWINGCABLE WITH DOUBLE COMPRESSION NFLP GLAND ANDCRIMPING SOCKETS 4CX2.5 SQMM END TERMINATI | - | Each |
| 10 | PROVIDING AND FIXING FOR | PROVIDING AND FIXING FOR — ROVIDING AND FIXING 4"" DIA PVC PIPES OF 6KG/SQCM OF APPROVED MAKE AS PER IS 4985 FOR RAINWATER PIPES INCLUDING ALL FITTINGS LIK BANDS ,SHOES ETC., MS FABRICATED BRACKET AS PERREQUIMENT ETC. ALL COMPLETE AS DIRECTED BY THEEIC." | - | meter |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2300010889-HD-09050.pdf
TENDER_DOCUMENT • 31.51 MB
Download all tender documents and submit your bid