Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.8 LAccepted-AOC OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | ₹43.8 L Quoted ₹44.9 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹49.6 L+₹4.7 L (10.5%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | ₹49.6 L+₹4.7 L (10.5%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹50.6 L+₹5.7 L (12.8%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹50.6 L+₹5.7 L (12.8%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹51.1 L+₹6.2 L (13.8%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | ₹51.1 L+₹6.2 L (13.8%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹51.1 L+₹6.2 L (13.8%)Rejected-Finance GATANGA MISSION CHARALI TEZPUR 784154 ASSAM | SONITPUR | ASSAM | 784154 | ₹51.1 L+₹6.2 L (13.8%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
27 Feb 2024, 6:00 pmClosed
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
REPAIR/REPLACEMENT OF INTERNAL ELECTRIFICATION WITH THEIR FITTINGS AND FIXTURES TO MARRIED AND OTM ACCN AT BASISTHA AREA UNDER GE GUWAHATI
2024_MES_640848_1
8730/GUW/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Guwahati
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Guwahati
₹1 L
Yes
6 Nov 2024
6 Feb 2024
29 Feb 2024
6 Feb 2024
27 Feb 2024
20 Feb 2024
Amount
Taking down carefully unserviceable copper / Aluminium point wiring including (light, fan, socket or power complete including fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, call bell, light or power sockets, light fittings etc) removing materials away from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
Taking down carefully unserviceable main switch and DB's including MCBs / MCCBs / RCCBs of any size make, type and capacity and removing materials away from site complete all as specified and directed.
M & L for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVC casing caping of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accessories including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling including one run 1.5 sqmm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable, 1100 volts grade, green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed for the following:-
One light/Fan point controlled by one, oneway modular switch complete all as specified and directed
One light point controlled by two, 2 way modular switches complete all as specified and directed.
One bell/buzzer point controlled by one modular push button switch on independent board complete all as specified and directed.
One 3/5 pin 5/6 Amps modular socket outlet on same board with other modular switches complete all as specified and directed.
One 3/5 pin 5/6 Amps modular socket outlet on independent board with cable of 1.5 sqmm size.
All as per item No.3 above but wiring with 4 sqmm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code) for phase & neutral, 1100 volts grade and 4 sqmm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable, (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable, green in colour, for earth continuity conductor for one 3/5 pin 15 Amps socket outlet on independent board complete all as specified and directed.
M&L for sub main wiring IN REPAIRS, using four runs of single core 10 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor (Red for phase and blak for neutral), 1100 volts grade (FRLSH) ISI marked drawn in and including rigid non metalic PVC concealed conduit & accessories like bends, tee, etc concealed / recessed in wall and ceiling, not less than 25mm dia and connecting to earth dolly and including two single core 10 Sqmm, FRLSH PVC insulated and unsheathed cable with copper conductor (green in colour as rarth wire), 1100 volts grade (FRLSH) ISI marked earth wire, complete all as specified and directed. NOTE: 4 runs of main wire, 2 run of earth wire, 1 run of conduit with accessories shall be measured as one length complete all as specified and directed.
M&L for sub main wiring IN REPAIRS, using four runs of single core 10 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor (Red for phase and blak for neutral), 1100 volts grade (FRLSH) ISI marked drawn in and including PVC casing and capping with accessories like bends, tee, etc fixed on wall and ceiling, not less than 25mm size and connecting to earth dolly and including two single core 10 Sqmm, FRLSH PVC insulated and unsheathed cable with copper conductor (green in colour as rarth wire), 1100 volts grade (FRLSH) ISI marked earth wire, complete all as specified and directed. NOTE: 4 runs of main wire, 2 run of earth wire, 1 run of PVC casing and capping with accessories shall be measured as one length complete all as specified and directed.
M&L for sub main wiring IN REPAIRS, using two runs of single core 6 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor (Red for phase and blak for neutral), 1100 volts grade (FRLSH) ISI marked drawn in and including rigid non metalic PVC concealed conduit & accessories like bends, tee, etc concealed / recessed in wall and ceiling, not less than 25mm dia and connecting to earth dolly and including one single core 6 Sqmm, FRLSH PVC insulated and unsheathed cable with copper conductor (green in colour as rarth wire), 1100 volts grade (FRLSH) ISI marked earth wire, complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length complete all as specified and directed.
M&L for sub main wiring IN REPAIRS, using two runs of single core 6 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor (Red for phase and blak for neutral), 1100 volts grade (FRLSH) ISI marked drawn in and including PVC casing and capping with accessories like bends, tee, etc concealed / recessed in wall and ceiling, not less than 25mm dia and connecting to earth dolly and including one single core 6 Sqmm, FRLSH PVC insulated and unsheathed cable with copper conductor (green in colour as rarth wire), 1100 volts grade (FRLSH) ISI marked earth wire, complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length complete all as specified and directed.
M&L for sub main wiring IN REPAIRS, using two runs of single core 4 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor (Red for phase and blak for neutral), 1100 volts grade (FRLSH) ISI marked drawn in and including rigid non metalic PVC concealed conduit & accessories like bends, tee, etc concealed / recessed in wall and ceiling, not less than 25mm dia and connecting to earth dolly and including one single core 4 Sqmm, FRLSH PVC insulated and unsheathed cable with copper conductor (green in colour as rarth wire), 1100 volts grade (FRLSH) ISI marked earth wire, complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length complete all as specified and directed.
M&L for sub main wiring IN REPAIRS, using two runs of single core 4 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor (Red for phase and blak for neutral), 1100 volts grade (FRLSH) ISI marked drawn in and including PVC casing and capping with accessories like bends, tee, etc concealed / recessed in wall and ceiling, not less than 25mm dia and connecting to earth dolly and including one single core 4 Sqmm, FRLSH PVC insulated and unsheathed cable with copper conductor (green in colour as rarth wire), 1100 volts grade (FRLSH) ISI marked earth wire, complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length complete all as specified and directed.
Supply and fixing IN REPAIRS, LED tube lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing IN REPAIRS, LED tube light fitting mirror type with high out put diffuser, 2 feet, 10 watt, 220 V AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing IN REPAIRS, LED light fitting 1X10 watts, bulkhead luminaires, including LED light, driver holder, pressure die cast, housing LED bulkhead with IP 65 Protection and IK 09 Impact resistance suitable for surface / wall mounting, complete with all accessories, pre-wired, connecting up twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing IN REPAIRS, LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver with and including three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing IN REPAIRS, round shape 15 watt, 220 volts AC, recessed type with high efficiency PMMA diffuser, soft glare free light, complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complet all as specified and directed.
Supply and fixing IN REPAIRS, LED flood light, 70 watt, 230 V AC, outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
Supply and fixing IN REPAIRS, post top lantern, LED type, 20 watt 230 volts AC, outdoor type with decorative post top for 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing IN REPAIRS, LED street light fitting, 60 Watt, 230 V AC, outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completeall as specified and directed
Supply and fixing IN REPAIRS, LED street light fitting, 35 Watt, 230 V AC, outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completeall as specified and directed
M&L for 32 mm bore, light grade, GI pipe as bracket, fixed on wall, any type, length of pipe not less than 1.5 m long and bent to shape as required complete with suitable clamp made out of 25 x 4mm flat iron duly fixed using 12mm dia nuts, bolts, washers etc. INCLUDING TAKING OUT OLD BRAKCETS AND REMOVING AWAY FROM SITE complete all as specified and directed by Engineer-in-Charge.
Supply and fix IN REPAIRS, Call bell, Ding Dong, AC, 230 volts, single pole complete all as specified and directed.
Supply and fix IN REPAIRS, modular switch, single pole, one way 5/6 Amps,1 module, 240 Volts, complete all as specified and directed.
Supply and fix IN REPAIRS, Modular switch, two way, 5/6 Amp, 1 module, 240 Volts, complete all as specified and directed.
Supply and fix IN REPAIRS, Modular Bell push, 6 Amp, 1 module, 240 Volts, complete all as specified and directed.
Supply and fix IN REPAIRS, Modular Bell push with indiator, 6 Amp, 1 module, 240 Volts, complete all as specified and directed.
Supply and fix IN REPAIRS, Modular socket outlet, 2/3 pin, 6 Amps, 2 module, 240 Volts, complete all as specified and directed.
Supply and fix IN REPAIRS, Modular switch, single pole, one way, 16 Amp, 1 module, 240 Volts, complete all as specified and directed.
Supply and fix IN REPAIRS, Modular socket outlet, 2 in 1, 6/16 amps, 2 module, 240 Volts, complete all as specified and directed.
Supply and fix IN REPAIRS, Modular socket 16A, 6 pin, 3 module 240 volts. complete all as specified and directed
Supply and fix IN REPAIRS, ceiling rose, Ceiling rose, 3 phase / PVC / polycarbonate, isolated body, ISI marked complete all as specified and directed.
Supply and fixing MODULAR FAN REGULATOR, Fan step regulator, 120W - 2 module, 230 volts, complete all as specified and directed.
Supply and fixing IN REPAIRS, lamp holder, PVC / polyarbonate type with bak plate suitable for batten fitting, complete all as specified and directed.
S&F IN REPAIRS, Factory made board distribution in sheet steel enclosure VTPN DB 4 WAY double door glazed with 200 Amps rated bus bar,, 415 Volts suitable for housing MCCBs as incomer and MCB as outgoing complete including sinking of DB on wall and making surface good complete all as specified and as directed.
S&F IN REPAIRS, Factory made board distribution in sheet steel enclosure vertical double door with 200 Amps rated bus bar, TPN, 4 ways, 240 Volts suitable for housing MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed.
S&F Factory made board distribution in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 8 ways, 240 Volts suitable for housing MCBs.complete all as specified and as directed.
S&F IN REPAIRS, Factory made board distribution in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 4 ways, 240 Volts suitable for housing MCBs.complete all as specified and as directed.
S&F IN REPAIRS, MCCB 125 Amps, 415 volts, 4 pole , 16 KA complete all as specified and as directed.
S&F IN REPAIRS, MCCB 125 Amps, 415 volts, 4 pole , 36 KA, fixed thermal and magnetic setting complete all as specified and as directed.
S&F IN REPAIRS, MCB, TPN, 415 volts, C Curve , 100 Amps, 10 KA, 4P complete all as specified and as directed.
S&F IN REPAIRS, MCB, TPN, 415 volts, C Curve , 63 Amps, 10 KA, 4P complete all as specified and as directed.
S&F IN REPAIRS, MCB, SPN, 240 volts, C Curve , 63 Amps 10 KA complete all as specified and as directed.
S&F IN REPAIRS, MCB, SPN, 240 volts, C Curve , 32 Amps 10 KA complete all as specified and as directed.
S&F IN REPAIRS, MCB, SP, 240 volts, 20-32 Amps 10 KA ,C Curve, complete all as specified and as directed.
M&L earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m complete all as specified and as directed.complete all as specified and directed.
S & F in replacement of batteries of 100 AH capacity including required electrical connection in existing UPS complete all as specified and directed.
S&F IN REPAIRS, power unit with 20A MCB & Plug 240 volts complete for ACs & Geyser complete all as specified and directed.
S&F IN REPAIRS, Motor Starter 25A 240 volts complete for ACs & Geyser complete all as specified and directed.complete all as specified and directed
S&F IN REPAIRS, Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed
HEMONTA DAS
PURBANCHAL BUILDERS
M/S R G Construction
M/S MOHANPASARI
M/s Dhruv Enterprises
M/s JK Jangid and Company
M/S. SUBHAS CONSTRUCTION CO.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .