Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-Finance CHAR GHOSHHAT FROM RANJIT HAWLADER HOUSE OF BIMAL DEBNATH HOUSE WARD NO 11 UNDER KATWA MUNICIPALITY WEST BENGAL | ₹19.3 L | L1 | Accepted-Finance Accept |
| 2 | L2₹19.4 LAccepted-Finance BARDHAMAN | WEST BENGAL | 713364 | ₹19.4 L | L2 | Accepted-Finance Accept |
| 3 | L3₹19.5 LRejected-Finance KATWA WEST BENGAL | ₹19.5 L | L3 | Rejected-Finance Reject |
Tender Value
₹19.5 L
EMD Value
₹39,043
Closing Date
20 Mar 2026, 5:00 pmClosed
CHAIRMAN KATWA MUNICIPALITY
CHAIRMAN KATWA MUNICIPALITY
Construction of Boundary Wall, Car Parking Platform Miscellaneous Renovation works of Sanitary Garrage Cum Office Building beside Kachhari Road, at Ward No-4, under 15th Finance Commission Tied Grant
2026_MAD_1019694_1
WBMAD 96 (DEV/15TH F.C./KM)2025-2026
Open Tender
CIVIL WORKS
45 days
Sanitary Garrage Cum Office Building Kachhari Rd
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹39,043
Yes
4 Jun 2026
10 Mar 2026
23 Mar 2026
10 Mar 2026
20 Mar 2026
10 Mar 2026
Earth Work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, and dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm SOR PWD (BUILDING) PAGE NO :- 1 , ITEM NO :- 2 (a),
(A) Filling in foundation trenches or plinth with silver sand in layer not exceeding 150 mm as directed and consolidating same by through saturation with water ramming complete including the cost of supply of sand (Payment to be made on measurement of finished quantity of work). SOR, PWD (BUILDING), PAGE NO :- 2 , ITEM NO :- 4 A
Single brick flat soiling of jhama bricks including ramming and dressing bed to proper level and filling joint with powered earth or local sand. SOR, PWD (BUILDING), 3RD CORRIGENDA, PAGE NO:-1, ITEM NO :- 1
Cement Concrete with graded stone ballast (40 mm size) excluding shuttering in ground floor.(6:3:1) SOR, PWD (BUILDING), 3RD CORRIGENDA, PAGE NO:-23, ITEM NO :- 1
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. i) Pakur Variety Rate Analysis Enclosed SOR, PWD (BUILDING), PAGE NO:-26, ITEM NO :- 10 Rate Analysis Enclosed
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth B.S. ITEM NO -08, Page- 15
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary . In ground floor. A) With 6:1 cement mortar. a) Inside wall 20 mm thick plaster i)In Groound Floor
In First Floor
In Second Floor Mumpty Room
b) Out side Wall, 15mm th. In Groound Floor
1st Floor
2nd Floor
c)10mm th celling plaster (4:1) Ground Floor
1st Floor
2nd Floor Mumpty Room
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. B.S. ITEM NO -15, Page- 192
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction (a) For works in foundation , basement and upto roof of ground floor/ upto 4m (i) JSW/JSPL/SHYAM(TOR STEEL)/HYSD/TATA , Rate analysis Enclosed
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (f) 25 mm to 30 mm shuttering without staging in foundation SOR, PWD (BUILDING), PAGE NO:-42, ITEM NO :- 36(f)
M.S. gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Locking arrangement for Jail type doors including supplying fitting and fixing in position complete as per approved design. (Concrete to be paid extra)
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.SOR, PWD (BUILDING), PAGE:- 200 , ITEM :- 1
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On Steel or metal Surface (iv) Two coats (with any shade except white) SOR, PWD (BUILDING), PAGE:- 200 , ITEM :- 2
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat SOR PWD (BUILDING) , PAGE:-197, ITEM:-17
Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor Two CoatSOR PWD (BUILDING) , PAGE:-197, ITEM:-16
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement 35mm thick SOR, PWD, 3rd Corrigenda, P- 22, I - 4
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) SOR, PWD, 3rd Corrigenda, P- 36, I -23 (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. B) Light Colour In Ground Floor
1st Floor
2nd Floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a)(b) Area of each tile above 0.09 Sq.m (i) Coloured decorative SOR, PWD, 3rd Corrigenda, P- 34, I -22 In Ground Floor
1st Floor
2nd Floor
Supplying, fitting and fixing UPVC down pipes A type and fittings conforming to IS 13592-1992 with necessary clamps nails including making holes in walls, etc. and cutting trenches in any soil, through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yarn, valamoid / bitumen / M. seal etc.) complete. P-213, I-21 A (ii), C(ii), D(ii) i) UPVC Pipe 110 mm dia
ii) UPVC Bend 87.5 degree 110 mm dia
iii) UPVC Shoe 110 mm
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. P.W.D./ S & P/P-29/ It. No-1 (i) CPVC Pipes Class-1, SDR-11 a) For Exposed Work 20 MM DIA
32 MM DIA
(b) For Concealed Work 15 mm Dia
Supplying, fitting and fixing bib cock or stop cock. P.W.D./ S & P/ P-6 / It. No-7 a(i) Chromium plated Bib Cock short with wall flange with aerator (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
B(i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
D(i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Suppling,fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with 'P' trap P.W.D./ S & P/P-79/ It. No-2
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. SOR PWD (BUILDING) PAGE NO :- 1 , ITEM NO :- 2 (a),
Sub Total
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.05 MB
2911FORM.pdf
Tender Documents • 1.48 MB
BOQ_2506054.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid