Construction of Site Development Works at Mahanadi Campus of Ravenshaw University, Cuttack, Odisha.
NBCC/PMGSY-ZONE/ODISHA/RU/2022/65
NBCC/PMGSY-ZONE/ODISHA/RU/2022/65
Open Tender-Domestic
Civil Works General
Cuttack, Odisha
₹11,800
₹11.4 L
7 Jul 2022
23 Jun 2022
7 Jul 2022
7 Jul 2022
13 Jul 2022
BILL OF QUANTITY OF SITE DEVELOPMENT WORKS. FOR MAHANADI CAMPUS OF
RAVENSHAW UNIVERSITY CUTTACK, ODISHA
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
1 Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of
grade M-25 of specified diameter and length below the pile cap, to carry a safe working
load not less than specified, excluding the cost of steel reinforcement but including the
cost of boring with bentonite solution and temporary casing of appropriate length for
setting out and removal of same and the length of the pile to be embedded in the pile
cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel
technique by tripod and mechanical Winch Machine all complete, including removal of
excavated earth with all its lifts and leads (length of pile for payment shall be measured
up to bottom of pile cap).
2 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of
loading platform by Kent ledge method and preparation of pile head or construction of
test cap and dismantling of test cap after test etc. complete as per specification & the
direction of Engineer in-charge.
2.01 Single pile above 50 tonne and up to 100 tonne Safe capacity
2.02 Routine test (Test Load 1.5 times the Safe capacity) Per Test 1.00 30505.00 30505.00
3 Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means
over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including
disposal ofexcavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be CUM 13196.02 205.45 2711122.31
levelled and neatly dressed. - in all kinds of soil
4 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out
the excavated soil and disposal of surplus excavated soil as directed, within a lead of
4.01 All kinds of soil Cum 1678.16 286.85 481378.76
5 Excavation work by mechanical means (Hydraulic excavator)/ manual means in
foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out
the excavated soil and disposal of surplus excavated soils as directed, within a lead of
5.01 Ordinary rock Cum 14.27 523.15 7464.83
5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited CUM 9272.58 253.95 2354771.69
layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated
or stacked materials.
6.01 All kinds of soil cum 66.38 104.50 6936.19
6.02 Ordinary or hard rock cum 59.74 187.40 11194.81
7 Clearing grass and removal of the rubbish up to a distance of 50 m
outside the periphery of the area cleared.
8 Supplying and filling in plinth with approved variety sand under floors including,
watering, ramming consolidating and dressing complete. CUM 386.21 2161.20 834684.83
9 Surface dressing of the ground including removing vegetation and in-equalities not
exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m.
9.01 All kinds of soil. Sqm 92.70 28.15 2609.51
10 Preparation and consolidation of sub grade with power road roller of 8 to 12tonne
capacity after excavating earth to an average of 22.5 cm depth dressing to camber and SQM 9906.00 180.50 1788033.00
consolidating the sub grade and disposal of surpluys earth lead upto 50 mtr.
11 Construction of granular sub-base by providing close graded Material conforming to
specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by
tippers to work site, for all leads & lifts, spreading in uniform layers of specified
thickness with motor grader on prepared surface and compacting with vibratory power
roller to achieve the desired density, complete as per specifications and directions of
Engineer-in-Charge.
11.01 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR
12 Providing, laying, spreading and compacting graded stone aggregate (size range 53
mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the
material with water at OMC in for all leads & lifts, laying in uniform layers with
mechanical paverfinisher in sub- base / base course on well prepared surface and CUM 3470.25 2803.65 9729366.41
compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density,
complete as per specifications and
directions of Engineer-in-Charge.
13 Providing and laying Dense Graded Bituminous Macadam using crushed stone
aggregates of specified grading, premixed with bituminous binder and filler, transporting
the hot mix to work site by tippers, laying with paver finisher equiped with electronic
sensor to the required grade, level and alignment and rolling with smooth wheeled,
vibratory and tandem rollers as per specifications to achieve\ the desired compaction
and density, complete as per specificatons and directions of Engineer-in-Charge.
RAKESH Digitally signed by RAKESH
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
13.01 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5%
(percentage by weight of total mix) and lime filler @ 2% (percentage by weight of
Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH
14 Providing and laying Bituminous concrete using crushed stone aggregates of specified
grading, premixed with bituminous binder and filler, transporting the hot mix to work site
by tippers, laying with paver finisher equiped with electronic sensor to the required
grade, level and alignment and rolling with smooth wheeled, vibratory and
tandem rollers to achieve the desired compaction and density as per specification,
complete and as per directions of Engineer-in-Charge.
14.01 40/50 mm compacted thickness with bitumen of grade
VG-30 @ 5.5% (percentage by weight of total mix) and
lime filler @ 3% (percentage by weight of Aggregate) CUM 555.24 10870.75 6035875.23
prepared in Batch Type Hot Mix Plant of 100-120 TPH
15 Painting road surface marking with adequate nos of coats to give uniform finish with
ready mixed road marking paint conforming to IS : 164, on bituminous surface in
white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and
foreign material etc. complete.
15.01 New work (Two or more coats) Sqm 5781.00 239.95 1387150.95
16 Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 6.5
in foundation and plinth in:
16.01 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 214.81 6658.25 1430256.60
17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
in superstructure above plinth level up to floor V level in all shapes and sizes in :
17.01 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 102.00 8288.35 845411.70
18 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10
average compressive strength in super structure above plinth level up to floor V level in
18.01 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 35.61 7676.30 273326.66
19 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with
grey cement slurry mixed with pigment to match the shade of the slab, including rubbing
and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
20 Providing and laying matt finished vitrified tile of size 100x100x16mm having water
absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours
and shades in out door floors such as footpath, court yard multi models etc., laid on
20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes &
patterns including grouting the joints with white cement mixed with matching pigments
etc. complete as direction of Engineer-in-Charge.
21 Finishing walls with textured exterior paint of required shade : New work (Two or more
coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer sqm 198.00 245.00 48510.00
applied @ 2.20kg/10 sqm
22 Providing and laying in position machine batched and machine mixed design mix M-25
grade cement concrete for reinforced cement concrete work, using cement content as
per approved design mix, including pumping of concrete to site of laying but excluding
the cost of centering, shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,
improve workability without impairing strength and durability as per direction of Engineer-
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/recoverable separately).
22.01 All works upto plinth level Concrete of M25 grade with
minimum cement content of 330 kg /cum
22.02 All works above plinth level upto floor V level Concrete of M25 grade with minimum
cement content of 330 kg /cum
23 Add for using extra cement in the items of design mix over and above the specified
cement content therein.
24 Centering and shuttering including strutting, propping etc. and removal of form for :
24.01 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 71.26 307.95 21944.52
24.02 Walls (any thickness) including attached pilasters, butteresses, plinth and string
24.03 Suspended floors, roofs, landings, balconies and access
24.04 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 82.71 804.25 66515.50
24.05 Weather shade, Chajjas, corbels etc., including edges Sqm 2.70 814.95 2200.37
24.06 Suspended floors, roofs, landings, balconies and access
platform with water proof ply 12 mm thick
24.07 Lintels, beams, plinth beams, girders, bressumers andcantilevers with water proof ply
25 Steel reinforcement for R.C.C. work including traightening, cutting, bending, placing in
position and binding all complete upto plinth level. Thermo-Mechanically Treated bars KG 50026.04 89.65 4484834.04
of grade Fe-500D or more.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
26 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level. KG 5562.90 89.65 498714.18
Thermo Mechanically treated bars
27 Supplying and fixing rolling shutters of approved make, made of required size M.S.
laths, interlocked together through their entire length and jointed together at the end by
end locks, mounted on specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull operation complete,
cost of providing and fixing necessary 27.5 cm long wire springs manufactured from
high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top
cover of required thickness for rolling shutters.
27.01 80X1.25mm M.S. laths with 1.25mm thick top cover Kg. 28.08 3008.80 84487.10
28 Steel work welded in built-up section/framed work including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer using structural steel etc.
28.01 In gratings, frames, guard bar, ladders, balcony and staircase railings, brackets, gates
and similar works
29 Providing and fixing M.S. grills of required pattern in frames of etc. with M.S. flats,
square or round bars etc. including priming coatwindows with approved steel primer all
29.1 Fixed to steel windows by welding kg 145.80 181.00 26389.80
30 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or
with fixing clips, or with expansion hold fasteners including necessary filling up of gaps
at junctions, at top, bottom and sides with required Silicon rubber/neoprene gasket etc.
Aluminium sections shall
be smooth, rust free, straight, mitred and jointed mechanically wherever required
including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass /
stainless steel screws, all complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing and paneling to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots
and making provision for fixing of fittings wherever required including the cost of Silicon
rubber / neoprene gasket required (Fittings shall be paid for separately).
30.01 Powder coated aluminium (minimum
thickness of powder coating 50 micron)
31 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions
etc. with PVC / neoprene gasket etc. complete as per the architectural drawings and the
directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in
31.01 With float glass panes of 4 mm thickness Sqm 14.18 1019.80 14455.67
32 Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate)
finished with a floating coat of neat cement including cement slurry, etc. but excluding
the cost of nosing of steps etc. complete.
32.01 40 mm thick with 20 mm nominal size stone aggregate Sqm 94.64 545.00 51578.80
33 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse
sand), finished with a floating coat of neat cement.
34 Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
34.01 40 mm wide and 4 mm thick Metre 236.60 79.50 18809.70
35 12 mm cement plaster of mix :
36 12 mm cement plaster of mix :
37 12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
38 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 finished
with a top layer 6mm thick cement plaster 1:6.
39 6 mm cement plaster of mix :
40 Neat cement punning. Sqm 505.22 67.80 34253.92
41 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.
42 Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces etc
consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with
water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls upto 300mm height including cleaning the
surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick
bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)
admixed with water proofing compound conforming to IS : 2645 and approved by
Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5
coarse sand ) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating similarly the adjoining
walls upto 300 mm height including rounding of junctions of walls and slabs
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
42.01 (c) After two days of proper curing applying a second coat of cement slurry using
2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick
jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineer-in-charge
including laying glass fibre cloth of approved quality in top layer of plaster and finally
finishing the surface with trowel with neat cement slurry and making pattern of 300x300
mm square 3mm deep. (e) The whole terrace so finished shall be flooded with water for
a minimum period of two weeks for curing and for final test. All above operations to be
done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120mm and minimum thickness at khurra as 65 mm.
43 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less
than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as
per manufacturer's specification.
Two or more coats on new work
44 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of
44.01 New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming
coat of exterior primer applied @ 2.20 kg/ 10 sqm)
45 Painting with synthetic enamel paint of approved brand and manufacture to give an
45.01 Two or more coats on new work. sqm 62.34 131.45 8194.59
46 Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels /
subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral
crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral
crystalline slurry : 1 part water) for horizontal surfaces and applying the same from
negative (internal) side with the help of synthetic fiber brush. The material shall meet
the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of
concrete by more than 90% compared with control concrete as per DIN 1048 and
resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be
capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out
all complete as per specification and the direction of the engineer-in-charge. The
product performance shallcarry guarantee for 10 years against any leakage. For vertical
surface two coats @ 0.70 kg per sqm
46.01 For vertical surface two coats @ 0.70 kg per sqm sqm 474.72 406.25 192855.00
46.02 For horizontal surface one coat @1.10 kg per sqm. Sqm 17.00 311.50 5295.50
47 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick
nominal size including spreading, well ramming, consolidating and grouting with jamuna
sand, including finishing smooth etc. complete as per direction of Engineer-in-charge.
48 75 mm thick back filling for pitching including supplying of required materials and
consolidation etc. complete with :
48.01 Stone aggregate 20 mm nominal size sqm 357.50 175.85 62866.38
48.02 Stone aggregate 40 mm nominal size sqm 357.50 167.25 59791.88
49 Structural steel work in single section, fixed with or without connecting plate, including
cutting, hoisting, fixing in position and applying a priming coat of approved steel primer kg 880.00 93.05 81884.00
50 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars
jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine metre 17.00 902.05 15334.85
sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
51 Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100%
polyester of thickness 1 to 1.25 mmbrane with Geotextile, 120 gsm non
52 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as
per manufacturer's specifications including appropriate priming coat, preparation of sqm 63.00 201.70 12707.10
surface, etc. complete. On steel work
53 Providing and placing in position 100 mm thick factory made machine batched &
machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes,
of M-25 grade cement concrete for RCC work, including cost of centering, shuttering,
reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both
ways , neat cement punning on finished surface, properly encased on all edges with 1.6 Sqm 1643.70 2617.15 4301809.46
mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be
welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c
cost of cartage, all leads & lift, handling at site etc. all complete as per direction of
Engineer-in-Charge.
54 Providing and laying Vapour Barrier of TRUPACK Laminated High Density Polyethylene
Woven Geomembrane for Water Proof Lining Type I ( Having thickness of 0.25mm and
mass of 250g/m², Min )as per specifications and as directed by Engineer-in-charge.
55 Providing and laying matt finished Vitrified tiles of size 300X300X9.8mm having with
water absorption less than 0.5% and conforming to IS: 15622 of approved make in all
colours and shades in for outdoor floors such as footpath, courtyard, multi modals
locations etc. laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coase sand)
in all shapes & patterns including grouting the joints with white cement mixed with
matching pigments etc. complete as per direction of Engineer-in-charge
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
56 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work up to plinth level :
56.01 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal
57 1:3:6 (1 cement : 3 coarse sand (grade-III) : 6 graded stone aggregate 40 mm nominal
58 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) cum 52.00 6050.65 314633.80
59 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand
: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick
ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand
including finishing the top smooth
60 Providing and laying 60mm thick faciory made cement concrete interlocking paver block
of M -30 grade made by block making machine with strong vibratory compaction, of
approved size, design & shape, laid in required colour and pattern over and including Sqm 2840.40 951.00 2701220.40
50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all
complete as per the direction of Engineer-in-charge.
61 Providing and laying factory made chamfered edge Cement Concrete paver blocks in
footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,
thickness & size/ shape, made by table vibratory method using PU mould, laid in
required colour & pattern over 50mm thick compacted bed of sand, compacting and
proper embedding/laying of inter locking paver blocks into the sand bedding layer
through vibratory compaction by using plate vibrator, filling the joints with sand and
cutting of paver blocks as per required size and pattern, finishing and sweeping extra
sand. complete all as per direction of Engineer-in-Charge.
61.01 80 mm thick C.C. paver block of M-30 grade with approved
color design and pattern.
62 Providing and laying at or near ground level factory made Kerb stone of M-25 grade
cement concrete in position to the required line, level and curvature, jointed with cement
mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves
(thickness of joints except at sharp curve shall not to more than 5mm) including making Cum 202.50 8613.55 1744243.88
drainage opening wherever required complete etc. as per direction of Engineer-in-
charge) length of finished kerb edging shall be measured for payment (Precast kerb
stone shall be approved by Engineer-in-charge)
63 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface
64 Direction and place identification signs upto 0.9 sqm board. (providing and erecting
direction and identification sing asper IRC : 67 made of encapculated lens type
reflective sheeting vide daus 801.3, fixed over aluminium sheeting, 2 mm thick witharea
not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm SQM 3.78 13383.00 50587.74
frmly fixed to the ground by means of properly . designed foundationwith M15 grade
cement concrete 45 x 45 x 60 cm, 60 cm belowground level as per approved drawing)
65 Supplying and stacking of good earth at site including royalty and carriage up to 1 km
(earth measured in stacks will be reduced by 20% for payment).
66 Supplying and stacking at site dump manure from approved source, including carriage
up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)
66.01 Screened through sieve of IS designation 20 mm cum 47.25 256.69 12127.46
66.02 Screened through sieve of IS designation 16 mm cum 47.25 293.61 13871.54
66.03 Screened through sieve of IS designation 4.75 mm cum 47.25 323.10 15264.90
67 Supplying and stacking of well decayed cow dung manure at site including royalty and
carriage up to 1.0 km (cow dung manure measured in stacks will reduced by 8% for cum 141.75 249.98 35433.96
PREPARATION WORKS
68 Fine dressing of the ground sqm 4200.00 3.74 15695.40
69 Mixing earth and sludge or manure in the required proportion specified or directed by
the Engineer-in-charge
70 Spreading of sludge, dump manure and / or good earth in required thickness as per
direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be cum 2173.50 52.87 114920.55
paid separately).
71 Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing
all weeds and other growth with roots by forking repeatedly, breaking clods, rough
dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine sqm 840.00 61.56 51709.98
dressing for planting new grass, including disposal of all rubbish with all leads and lifts
72 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with
manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after
reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding
with water, dressing including removal of rubbish and surplus earth, if any, with all leads
and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
72.01 Holes 1.2 m diameter and 1.2 m deep no 50.00 338.86 16942.75
72.02 Holes 90 cm diameter and 90 cm deep no 450.00 144.53 65038.95
72.03 Holes 60 cm diameter and 60 cm deep no 13320.00 44.19 588577.50
72.04 Holes 45 cm diameter and 45 cm deep no 41100.00 18.89 776255.70
73 EVERGREEN TREE
73.01 Azadirachta Indica No. 100.00 75.40 7540.00
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
73.02 Alstonia scholaris No. 120.00 75.40 9048.00
73.03 Ficus benjamina No. 130.00 121.80 15834.00
74 FLOWERING TREE
74.01 Bauhinia purpurea No. 80.00 58.00 4640.00
74.02 Callistemon lanceolatus No. 60.00 75.40 4524.00
74.04 Cassia fistula No. 80.00 75.40 6032.00
74.06 Plumeria rubra No. 20.00 464.00 9280.00
76.01 Buddha belly bamboo No. 50.00 1189.00 59450.00
77.01 Clerodendrum inerme No. 3000.00 11.60 34800.00
77.03 Ficus benjamina Starlight No. 720.00 998.76 719107.20
77.04 Gardenia jasminoides No. 1440.00 58.00 83520.00
77.07 Hibiscus rosa-sinensis No. 1200.00 40.60 48720.00
77.09 Tecoma gaudichaudi No. 720.00 40.60 29232.00
78 GROUND COVERS
78.01 Alternanthera red No. 6000.00 23.20 139200.00
78.02 Chlorophytum comosum No. 7500.00 23.20 174000.00
78.04 Sprenger's asparagus No. 4500.00 23.20 104400.00
78.05 Syngonium podophyllum No. 9000.00 34.80 313200.00
78.06 Tradescantia pallida No. 10500.00 24.36 255780.00
Cynodon dactylon
80 Providing and laying in trench cement concrete ( 1:3:6 ) with 40mm size hard granite
metal in the following type of bedding & encasing for undeground drainage pipe of the
following internal diameter including curing complete as per specification
81 Providing and laying and jointing PE/PP DWC(DOUBLE WALL CORRUGATED pipes
SN-4(RING FIT ) as per IS- 16098 of approved quality jointed with rubber sealing rings
or as per manufacture's instruction including testing of joints etc. complete,including
excavatin in all kind of soil (hard/soft), dewatering, refilling, watering, ramming &
removing the surplus excavated material and making good the same complete as
required (For Sewer line, & under groind rain water pipe).
82 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand )
with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded
stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4
coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside
plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with
floating coat of neat cement andmaking channels in cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating
coat of neat cement complete as per standard design :
82.01 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total weight of cover and frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15 kg) :
82.02 With Sewer bricks conforming to IS : 4885 Nos 45.00 11567.00 520515.00
83 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size
(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design:
83.01 150 x 100 mm size P type
83.02 With sewer bricks conforming to IS : 4885 Nos 15.00 2428.45 36426.75
84 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required
shape and approved quality
84.01 H D - 20 (Circular shape 560 mm internal diameter) Nos 250.00 1494.20 373550.00
85 Supplying, installing, testing and commissioning of centrifugal openwell submerssible
horizontal horizontal end suction pumps for supplying water from ugr to over head
tank The pump shall have cast iron delivery casting , cast iron impeller SS Shaft.
Pump shall be provided with mechanical seal (gland packing).The pump shall be
suitable for auto/ manual operation shall be provided with dry running protection and
N.R.V. at delivery.all complete
pump (1 working + 1 stand by)
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
Purpose=Supplying of ugr water to over head tank
Location - Inside ugr
Flow rate of each pump =20 cum/hour
Head of each pump= 25 met
WATER SUPPLY PIPE ON TERRACE AND WATER SUPPLY RELATED ITMES
86 Providing and fixing electronic type level indicator for water tanks mounting in panel with
the following features, level display, alarm when water level is low or high, full range
from one level to four level display and manual reset for Alarm etc. with electrical wiring No 1.00 25000.00 25000.00
conduit supports from wall & ceiling probes and all other accessories complete as
87 Providing and fixing of of following nominal dia Upvc sch-40 pipes including fixing of
required size upvc fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall
or floor with holder bat clamps screw etc. including testing the joints with required water
presure. SUPREME/ASTRAL/ASHIRVAD
88 Providing and fixing gunmetal gate valve with CI wheel of approved quality (Screwed
89 Providing and fixing 50 mm dia gunmetal non return valve of approved quality
89 Providing and fixing rungs inside ugr Nos 10.00 400.00 4000.00
Providing and fixing rectangular high density polyethylene water storage loft tank with
cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in- 10000.00 9.70 97000.00
charge. The rate includes making necessary holes for inlet, outlet & over flow pipes.
The base support i/c fittings & fixtures for tank shall be paid separately.
91 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting samples from different strata,
preparing and submitting strata chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for the job, all complete as per
direction of Engineer -in-charge, up to 90 metre depth below ground level.
91.01 All Types of Soil 300mm dia Metre 180.00 592.05 106569.00
92 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting samples from different strata,
preparing and submitting strata chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for the job, all complete as per
direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below
92.01 All Types of Soil 300mm dia Metre 120.00 690.70 82884.00
93 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting samples from different strata,
preparing and submitting strata chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for the job, all complete as per
direction of Engineer -in-charge, beyond 150 metre & upto 250 metre depth below
93.01 All Types of Soil 300mm dia Metre 100.00 762.00 76200.00
94 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized
PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including
required hire and labour charges, fittings & accessories etc. all complete, for all depths,
as per direction of Engineer -in-charge.
94.01 200 mm nominal size dia Metre 300.00 971.30 291390.00
95 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized
PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire
& labour charges, fittings & accessories etc. all complete, for all depths, as per direction
of Engineer-in-charge.
95.01 200 mm nominal size dia Metre 100.00 1099.25 109925.00
96 Gravel packing in tubewell construction in accordance with IS: 4097, including providing
gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all cum 30.00 1479.25 44377.50
complete as per direction of Engineer-in-charge.
97 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to
establish maximum rate of usable water yield without sand content (beyond permissible
limit), with required capacity air compressor, running the compressor for required time
till well is fully developed, measuring yield of well by "V" notch method or any other
approved method, measuring static level & draw down etc. by step draw down method, Hr. 360.00 916.80 330048.00
collecting water samples & getting tested in approved laboratory, i/c disinfection of
tubewell, all complete, including hire & labour charges of air compressor, tools &
accessories etc., all as per requirement and direction of Engineer-in-charge.
98 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top
of bore well housing/ casing pipe, removable as per requirement, all complete for
99 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of
tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
100 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe
assembly of tubewell as per IS:2800 (part I).
101 Point Wiring in Medium Class PVC Conduit, with Modular type Switch: Wiring for
light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface/recessed Stee conduit, with
modular type switch, modular plate, suitable size of GI box and earthing the point with
1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Make:- PVC insulated copper conductor single core cable in surface/recessed Stee
conduit . Make: of FRLS CU Wire,:- RR KABLE / GLOSTRER / FINOLEX /
102 Wiring for light/power plug with 2x4 Sq.mm FRLS PVC insulated copper conductor
single core cable in surface/recessed Medium Class PVC conduit along with 1 No. 4
Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing etc.
as required. Make:- .RR KABLE / GLOSTRER / FINOLEX / HAVELLS/KEI
103 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
PVC insulated copper condcutor, single core cable in surface/ recessed Medium Class
PVC conduit as required. Make:- .RR KABLE / GLOSTRER / FINOLEX / HAVELLS/KEI
103.03 4 X 6 sq.mm + 2 X 6 sq.mm earth wire. Mtrs. 75.00 394.00 29550.00
104 Supplying and fixing of following switch/ socket on the existing modular plate & switch
box including connections but excluding modular plate etc. as reqd. Make:- LEGRAND-
ARTIOR/SCHNEIDER-GENCELLO / MK-BLENZ / ANCHOR-VISION
104.01 3 pin 5/6A socket outlet Each 6.00 111.00 666.00
105 Supplying and fixing two module Stepped type electronic fan regulator (2 Module)
on the existing modular plate & switch box including connections but excluding modular
plate etc. as reqd. Make:-LEGRAND-ARTIOR/SCHNEIDER-GENCELLO / MK-BLENZ /
106 Supplying and fixing modular blanking plate on the existing modular plate & switch
box excluding modular plate as required.Make:- LEGRAND-ARTIOR/SCHNEIDER- Each 6.00 32.00 192.00
GENCELLO / MK-BLENZ / ANCHOR-VISION
107 Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet
and 5/6 A modular type switch, connections painting etc. as reqd,Make:-LEGRAND-
ARTIOR/SCHNEIDER-GENCELLO / MK-BLENZ / ANCHOR-VISION
108 Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular
socket outlet and 15/16 A modular type switch, connections painting etc. as reqd. Make:- Nos. 8.00 307.00 2456.00
LEGRAND-ARTIOR/SCHNEIDER-GENCELLO / MK-BLENZ / ANCHOR-VISION
109 Supplying & fixing of 3 pin, 5 amp Ceiling rose on the existing junction box/ wooden
block including connection as required.Make:-ANCHIR/KONA OR AS APPROVED BY Each 50.00 65.00 3250.00
110 Supplying and fixing brass batten/angle holder including connection etc. as
required.Make:- ANCHIR/KONA OR AS APPROVED BY ARCHITECT
111 Installation, testing and commissioning of suspended pre-wired ,fluorescent fitting /
compact fluorescent fitting of all types, complete with all accessories and tube/lamp
etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20
mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down
rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single
core cable and earthing etc. as required.
112 Installation, testing and commissioning of ceiling fan, including wiring the doen rods of
standerd length (upto 30 cm) with 1.5 sq mm FRLS PVC insulated, copper conductor, Each 10.00 171.00 1710.00
single core cable etc. as required
113 Installation of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required.
114 Providing and fixing following rating and breaking capacity andpole MCCB with
thermomagnetic release and terminal spreaders in existing cubicle panel board
including drilling holes in cubicle panel, making connections, etc. as required. Make:-
L&TD-SINE/LEGRANDDPX³/SCHNEIDERNSX/ SIMENS- 3VL-3WL./ABB-Tmax.
115 Supplying and fixing following Way Single pole and Neutral, Sheet steel, SP MCB
double distribution board, 240 volts on surface/ recess, complete with loose wire box
,terminal connectors for all incoming and outgoing circuits ,duly prewired with suitable
size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper
busbars, neutral link, earth bar, dinbar, detachable gland plate , interconnections
powder painted including p earthing etc. as required.(But without MCB/RCCB/Isolator)
Make:- SIEMENS-Bitaguard, LEGRAND-Ekinox-, SCHNEIDER-ACTI-9, L&T-AU-
115.01 8 Way Double Door Each 2.00 1760.00 3520.00
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
116 Supplying and fixing following way, horizontal type thee pole & neutral, sheet steel,
MCCB Double Door distribution board, 415V, on surface/ recces , complete with tinned
copper bus bar, neutral bar, earth bar, din bar interconnections, powder painted
including earthing etc. as required (But without MCCB/RCCB/Isolator) Make:-
SIEMENS-Bitaguard, LEGRAND-Ekinox-, SCHNEIDER-ACTI-9, L&T-AU-Version
117 Supplying and fixing following Ways surface/recess mounting, vertical type, 415 V,
TPN MCCB distribution board of sheet steel, dust protected, duty powder painted,
inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for
mounting MCBs (But without MCCBs and incomer ) as required. (Note : vertical type
MCCB TPDB is normally used where 3 phase outlest are required.) Make:- SIEMENS-
Bitaguard, LEGRAND-Ekinox-, SCHNEIDER-ACTI-9, L&T-AU-Version
118 Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, C curve Miniature
Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required. (Make:-
LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200MSIEMENS- BETA GUARD/ L&T- AU
119 Supplying and fixing single pole blocking plate in the existing MCB DB complete etc.
as required. Make:-LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200M/ SIEMENS- Each 1.00 8.00 8.00
BETA GUARD/ L&T- AU
120 Supplying & fixing following rating double pole (Single Phase & Neutral) 240 V,
Resudual Curren Circuit Breaker (RCCB) , having a sensitivity suitable for inductive
loads of following poles in the existing MCB DB complete with connections, testing and
ccurrent 30 mA in the existing MCB DB complete with connections, testing and
commissioning etc. as required.Make:- LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-
S200M/SIEMENS- BETA GUARD/ L&T- AU
121 Supplying and fixing of 20 Amps, 240 Volts, SPN Industrial type, socket out lets, with 4
pole and earth, metal enclosed plug top alongwith 20 Amps."C" curve, SP MCB, in
sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket
0ut let and complete with connections, testing and commissioning etc. as
required.Make:- LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200M/SIEMENS- BETA
122 Supplying and fixing of 20 Amps, 415 Volts, TPN Industrial type, socket out lets, with 4
pole and earth, metal enclosed plug top alongwith 20 Amps."C" curve, TP MCB, in
sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket
0ut let and complete with connections, testing and commissioning etc. as required.
Make:- LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200M/SIEMENS- BETA GUARD/
123 Supplying and fixing of 30 Amps, 415 Volts, TPN Industrial type, socket out lets, with 4
pole and earth, metal enclosed plug top alongwith 30 Amps."C" curve, TP MCB, in
sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket
0ut let and complete with connections, testing and commissioning etc. as required.
Make:- LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200MSIEMENS- BETA GUARD/
124 Providing & fixing of M.V. danger notice plate of 200 mm x 150 mm, made of mild steel,
at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in Each 2.00 226.00 452.00
single red colour on front side as required.
125 Providing & fixing of H.T. danger notice plate of 250 mm x 200 mm, made of mild steel,
at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in Each 3.00 244.00 732.00
single red colour on front side as required.
126 G.I. Piper Earthing:- Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe etc.
with charcoal/ coke and salt as required.
127 Copper Plate Earthing :- Earthing with copper earth plate 600 mm X 600 mm X 3 mm
thick including accessories, and providing masonry enclosurewith cover plate having Each 4.00 11794.00 47176.00
locking arrangement and watering pipe of 2.7 metre long etc. with charcoal.
128 Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground/surface
as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer
etc. as required (Jointing shall be done by overlapping and with 2 sets of brass nut bolt Mtr 30.00 853.00 25590.00
& spring washer spaced at 50 mm) (to us in Neutral Pits of Transformer)
129 Supplying and laying 25 mm X 5 mm GI strip at 0.50 meter below ground/surface as
strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc.
as required(Jointing shall be done by overlapping and with 2 sets of brass nut bolt &
spring washer spaced at 50 mm)
130 Providing and fixing 4mm dia copper wire on surface or in recess
for loop earthing as required.
131 Providing and fixing of 50mm X 5mm Copper Strip on surface or in recess for
connections etc. as required.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
LIGHTNING CONDUCTOR
132 Providing and fixing of Lightning Conductor finial, made of 25 mm dia 300mm ling,
copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate Each 4.00 448.00 1792.00
including holes etc. complete as required.
133 Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for
lightning conductor complete as required. (for Horizontal Run)
134 Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for
lightning conductor complete as required. (for Vertical Run).
135 G.I. Piper Earthing:- Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe etc.
with charcoal/ coke and salt as required.
136 Supplying and laying 25 mm X 5 mm GI strip at 0.50 meter below ground/surface as
strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc.
as required (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt &
spring washer spaced at 50 mm)
137 MV CABLE LAYING IN GROUND :- Laying of one number PVC insulated and PVC
seathed /XLPE power cable of 1.1 KV grade of following size direct in ground including
excavation, sand cushaning, protective covering and refilling the trench etc. as
137.02 Above 35 Sq. mm and up tp 95 sq. mm Mtr 30.00 338.00 10140.00
137.03 Above 95 Sq. mm and up tp 185 sq. mm Mtr 150.00 352.00 52800.00
138 MV CABLE LAYING IN GROUND:- Laying of one number additional PVC insulated
and PVC seathed /XLPE power cable of 1.1 KV grade of following size direct in ground
in same trench in one tire horizontal formation, including excavation, sand cushaning,
protective covering and refilling the trench etc. as required.
138.01 Above 185 Sq. mm and up tp 400 sq. mm Mtr 160.00 294.00 47040.00
139 HT CABLE LAYING:- Laying of one number additional PVC insulated and PVC
seathed /XLPE power cable of 11 KV grade of following size direct in ground including
excavation, sand cushaning, protective covering and refilling the trench etc. as
140 1.1 KV Cable End Termination:-Supplying and making indoor cable end termination
with brass double compression gland and aluminium lugs for following size of PVC
insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. Make:- Gland & Lux:-
DOWELL / CAPITAL
11 KV Cable End Termination:-
141 Supplying and making indoor cable end termination with heat shrinkable jointing kit
complete with all accessories including lugs suitable for following size of 3 core XLPE
aluminium conductor cable of 11 KV grade as required.
142 11 KV Cable End Termination:-
142.01 Supplying and making out door cable end termination with heat shrinkable jointing kit
complete with all accessories including lugs suitable for following size of 3 core XLPE
aluminium conductor cable of 11 KV grade as required
143 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete
with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required (as per
DBR Make list :- Jindal, Tata)
LED LIGHT FIXTURES
144 All the LED lamp shall be of minimum 100 or above lumens per watt and all UGR LED
LIGHTS should have minimum 105Lm/W or above lumens per watt. @L70 & Lumen
maintenance as per L70. LM 79 and LM 80 reports need to be submitted with all
accessories by the contractor. All LED light fixture must have two years warranty and
50,000 burning hours. Approved Make:- Philips/Havells/Lighting Technology/ Wipro/
144.01 Supply fitting, fixing and testing of 9W/10W LED Bulb glare free in existing holders. Each 15.00 180.00 2700.00
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
145 Supply fitting, fixing and testing of surface mounted 9/10W LED Tube Light surface /
wall mounted 2ft light fixture made of ultra slim co-extruded polycarbonate channel with
housing part in white finish & diffuser part in reeded opal finish, White finish ABS end
caps with decorative circular coloured polycarbonate cap snap fitted on the end cap with
inbuilt electronic driver. Lumen> 950, Efficacy is 105 lm/W. Luminaire manufacture
shall provide LM79report from NABL accredited lab & LM80 report issued by LED
manufacturer & 50,000 buring hours.. Make:- Philips/Havells/Lighting Technology/
146 Supply, fitting, fixing and testing of 20/22W LED Tube Light surface / wall mounted 4ft
LED tube light fixture Made of ultra slim co-extruded polycarbonate channel with
housing part in white finish & diffuser part in reeded opal finish, White finish ABS end
caps with decorative circular coloured polycarbonate cap snap fitted on the end cap with
electronic driver. Lumen >2200, Efficacy is 105 lm/W, 5700K.Luminaire manufacture
shall provide LM79report from NABL accredited lab & LM80 report issued by LED
manufacturer & 50,000 buring hours. Make:- Philips/Havells/Lighting Technology/
147 Supply, fitting, fixing and testing of 1x40W LED Tube Light suspended with
chain,suspension rope and mounting holders or 20mm G.I. Pipe, ball & sockets 4ft
LED tube light fixture (minimum 40mm width and 1200 mm length) Made of extruded
Aluminium and CRCA Housing with milkcy white polycarbonate diffuser, built in
electronic driver with ABS end caps with decorative coloured polycarbonate cap snap Each 16.00 4231.00 67696.00
fitted on the end cap. Lumen >4400, Efficacy is 110 lm/W. 5700K . Luminaire
manufacture shall provide LM 79 report from NABL accredited lab & LM 80 report
issued by LED manufacturer & 50,000 buring hours. Make:- Philips/Havells/Lighting
Technology/ Wipro/ Jaquar
148 Supply , fitting, fixing and testing of 10W, LED bulkhead made of polycarbonate
housing, LED Used shall be SMD type and fixture should have minimum efficacy at
System level (Not Chip Level) ≥80 to 110 lumens/watt with Minimum system Lumens
800, IP66. @ L70B50 Lumen maintenance, CCT of 6500K CRI ≥80, PF ≥0.95, Min
working temp range -0°C ≤ Ta ≤+ 35°C, an operating Voltage Range of 140 - 270 VAC. Each 10.00 1803.00 18030.00
Minimum Internal Surge Protection 3.5KV & IP66/IK07 protection. The LED luminiare
manufacturer shall have in-house NABL accredited lab to conduct type test as per IS-
10322 & LM79 test . Make:- Philips/Havells/Lighting Technology/ Wipro/ Jaquar
149 Supply, fitting, fixing and testing of IP20, 15W LED Surface Mounted downlight Light
Fixture, Polycarbonate housing with pressure diecast heat shink and PC deuffiser,
Lumen>1500, Efficacy >100 lm/w, operating temp -10 degree to +40 degreeC,
operation voltage 140 to 300V AC. The fixture design should comply with EMC / EMI
compliance along with BIS certification for LED Driver & Luminaire. Luminaire
manufacture shall provide LM79report from NABL accredited lab & LM80 report issued
by LED manufacture & 50,000 buring hours. Make:- Philips/Havells/Lighting
Technology/ Wipro/Crompton
150 Supplying, fixing and testing of 22/ 24W Round\.Square surface mountedLED light
fixtures made of powder coated, elegantly designed pressure die-cast aluminium heat
sink for efficient dissipation & white finish polycarbonate ring for holding the diffuser
,High reflective polycarbonate conical shaped reflector,High quality polycarbonate opal
concave diffuser.Minimum Lumen>2400Lm, Efficacy is>110lm/w, and High efficiency
driver with in-built surge protection, over voltage protection, short circuit protection and
operating at >0.9 PF. <5% THD. The fixture design should comply with EMC / EMI Each 10.00 5367.00 53670.00
compliance along with BIS certification for LED Driver & Luminaire. Luminaire
manufacture shall provide LM79report from NABL accredited lab & LM80 report issued
by LED manufacturer & 50,000 buring hours.(to use in double height area ) Make:-
Philips/Havells/Lighting Technology/ Wipro/ Jaquar
151 Supplying. fixing and testing of 45 watt LED Building Outer light (Street Light) with
pressure die cast aluminium housing, separate driver, and optical compartment for
Thermal isolation, Corrosion Proof, Optical system consists of a injection moulded UV
stabilized lens cover. High efficiency electronic driver with Power factor > 0.95 and THD
< 10%, Inbuilt surge protection of 6 KV, IP 66, confirming to I.S:10322 Part5.Section-3.
The Luminaire System Efficacy > 110 Lm/W, complete with all accessiries etc. to use Each 4.00 5925.00 23700.00
as building outer light including connections with FRLS PVC insulated copper conductor
cable and earthing the body etc. as required with 5ft long 40mm dia G.I. pipe with 3
Nos. of iron clamps , anchor nut bolts with double washers as per direction of E/I or
consultant as per drawing prescribed. 50,000 burning hours . Make:-
Philips/Havells/Lighting Technology/ Wipro/ Jaquar
152 POST OF LAMP --Supplying. fixing and testing of 40/45 Watt LED clear type post top
lantern having socket size 50mm suitable for Garden/Park/ Post of Lamp complete with
integrated electronic driver made in die cast aluminium housing with decorative
clear/opal acrylic difufusier and all accessories including connection with PVC insulated
copper conductor cable and earthing the body etc. as required. (IP- 66) confirming to
I.S:10322 Part5.Section-3.- (to be installed in 4 Mtr. Octogonal Poles.) & 50,000 buring
hours. Make:- Philips/Havells/Lighting Technology/ Wipro/ Jaquar
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
153 Supplying. fixing and testing of 25/30 Watt LED type post top lantern having socket
size 50mm suitable suitable for Gate light complete with integrated electronic driver
made in die cast aluminium housing with decorative clear/opal acrylic difufusier and all
accessories including connection with PVC insulated copper conductor cable and Each 4.00 8952.00 35808.00
earthing the body etc. as required. (IP- 66) confirming to I.S:10322 Part5.Section-3 &
50,000 buring hours.. Make:- Philips/Havells/Lighting Technology/ Wipro/ Jaquar
154 Supplying. fixing and testing of 90/100 watt LED Street Light with pressure die cast
aluminium housing, separate driver, and optical compartment for Thermal isolation,
Corrosion Proof, Optical system consists of a injection moulded UV stabilized lens
cover. High efficiency electronic driver with Power factor > 0.95 and THD < 10%, Inbuilt
surge protection of 6 KV, IP 66, confirming to I.S:10322 Part5.Section-3. The Luminaire
System Efficacy > 110 Lm/W, complete with all accessiries etc & 50,000 buring hours.
.Make:- Philips/Havells/Lighting Technology/ Wipro/ Jaquar
Integral Bollards:-
155 Providing, fitting, fixing and testing of Bollard light decorative luminaire light fixture of
800mm in length (IP-65) 9/10 W LED Lamp available in CCT of 3000K/4000K with
integrated baseplate and driver for easy installation, Operating voltage of 220-240 V,
wide beam optics and transluscent diffuser tube. New generation, energy saving,
environmental friendly,long life aesthetically designed die-cast aluminium, landscape
luminaire for downward lighting with high power LED as light source, Warm White. The
fixture should have extruded aluminium housing and heat resistant silicone rubber
gasket, Operating temperature ranging from -20° C to 40°C, The fixture should have
IP65 protection and IK10 impact resistance. Driver shall be high efficiency having
efficiency > 85% and in compliance to IEC standards. with foundation, commissioning,
testing all with all other accessories as per drawing provided at the time of work
execution or as per the direction of E/I) & 50,000 buring hours . Make:-
Philips/Havells/Lighting Technology/ Wipro/ Jaquar
1 no.Bollard light Fixture with 9W LED lamp
1 no. Terminal Box (Size - 8" x 6" x 4") of 2 mm CRCA sheet steel powder coating with
locking arrangement and rubber gasket etc.
1 no. 2A SP MCB Make- As per approved make list.
2 Nos. stud type 4 studs 20A connector (1 No. for incomer and 2nd for outgoing cable)
155.01 Total cost of Bollard light with all above accessories. Set 12.00 9437.00 113244.00
FANS & Exhaust FANS
Make of Fans:- Usha/Havells / GEC/Crompton.
156 Supplyof 1200mm sweep ceiling fans complete without regulator, double ball bearing,
motor, blades, down rod, canopies, capacitor, suitable for operation on 230 volts, 50
Hz., 1 phase, AC supply connection with 1.5 sq.mm PVC Copper wire complete as Each 10.00 2063.00 20630.00
required (rated minimum air delivery of 210 CMM/M , ISI marked & 2 years warranty.
Colour of Ceiling Fan- White/Ivory
157 Supply, fitting, fixing and testing of Wall Fan 400mm 230V 50 Hz., 1 phase, AC supply
with blade, guard (net), revolving type with regulator system and proper stand and
fixing clamps. 2 years warranty. . Make: USHA / HAVELLS / CROMPTON/GEC (ISI,)
158 Supply, fitting, fixing and testing of 300mm 230V, 50 Hz., 1 phase, AC supply 1400
RPM Exhaust Fan, ISI Brand (Meta Body- Light Duty) exhaust fan double ball bearing
as required. Make:- USHA / HAVELLS / CROMPTON/GEC (ISI, 2 YRS. WARRANTY)
159 Supply, fitting, fixing and testing of 230 mm, 230V AC, 1400 RPM, Exhaust Fan, ISI
Brand (Metal Body- Light Duty) exhaust fan double ball bearing as required. Make: Each 2.00 1770.00 3540.00
USHA / HAVELLS / CROMPTON/GEC (ISI, 2 YRS. WARRANTY)
11KV H.T. METER (INDOOR TYPE): 0.00 0.00
160 Supply, Receiving, Unloading, Storing, Shifting, Installation, Testing & Commissioning
of indoor type floor mounted, dust, damp and vermin proof, cubicle HT. Meter with CT &
PT sturcture Panel made out of 14 gauge CRCA sheet steel complete with 5Amp
electronic trivector meter, C.T.'s of 60/5Amp, 0.5 Class, 10VA Burden, and P.T's of
11KV/ /3, 110V/ /3, 100 VA conforming to relevant IS Standards and complete as Set 1.00 213728.00 213728.00
required. H.T. Metering cubicle along with C.T.'s, P.T.'s and trivector meter shall be got
tested and approved from local electricity supply authority. The GA drawing of HT Meter
has to be approved by STATE ELECTRICITY BOARD authorities before installation.
Make:- L & T/ Secure / HPL.
161 11kV 350 MVA, 630 amps Vacuum circuit breaker (HT Panel) indoor type fitted
with arc control devices with CT rating shall be as per 630 KVA Transformer
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
Supply Unloading at site, Shifting to location, Erection, Testing and Commissioning of a
OEM Manufactured, SINGLE Panel indoor VCB) duty totally enclosed sheet steel clad
floor mounting, vermin proof, fully interlocked vertical isolation, extensible, horizontal
draw out, Manually and motor operated, spring charged (release closing mechanism)
trip free type, triple pole truck mounted air insulated, metal clad switchboard having
double isolation features complete with circuits as detailed below. The switchboard
would be complete with necessary PVC insulated Copper Busbars, small wiring,
labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and
suitable for operation on 11 kV 3 phase, 50 cycle, earthed system with a rupturing
capacity of 350 MVA comprising of 630A/25kA/1Sec. (as per IS: 13118) at 11 kV Panel
as per SLD and specification as required. This HT panel must be extendable for future
requirement in such a manner not to disrupt ongoing services at the point of use during
extension. The single HT PANEL shall be equipped with following accessories and as
per specifications and schematic drawing along with over load, earth fault protection,
voltmeter, ammeter, CT’s, power factor meter, Kwh meter, P.T, power pack system
along with all other protection meters including indicating lamps as per requirement
.This HT panel must be extendable for future requirement in such a manner not to
disrupt ongoing services at the point of use during extension. The cost of above HT
Panel shall be inclusive of foundation as per the dynamic load of HT Panel or as per the
direction of E/I or Consultant. Make:- L & T/Crompton Greaves/
Seimenns/Schneider/ABB. (OEM Manufactured HT panel shall be accepted not
from any Authorized Partner of any Company .)
All Incoming and outgoing feeders shall have fault trip auxiliiary contacts for wiring to
annunciation fault trip indication panel
HT panel equipped with :
1- Air insulated metal clad housing
1- set of 3 phase PVC insulated copper busbars 630 amps rating
6- single pole cluster type isolating contacts i.e. plug and switches
1- Triple pole draw out truck mounted 11kV 350 MVA, 630 amps Vacuum circuit
breaker fitted with arc control devices with CT rating shall be as per 630 KVA
6 NO/NC contacts for remote ON/OFF/TRIP status at BMS
1- Trip free 230 V AC, motor charged spring release closing mechanism complete with
necessary auxiliary switches, emergency hand trip device and mechanical 'OFF' & 'ON'
1 - 24 Volt DC shunt trip coil
3 - Dual Core Cast resin Current transformers of ratio 75-120/5A Class 5P10 and Class
1.0, 15 VA burden for protection & metering.
The potential or voltage transformers shall be cast resin type and shall generally
conform to IS: 3156. The potential transformers shall be draw out type and shall be
provided with fuses on primary side and MCB/Fuses with on secondary side.
The draw out mechanism shall disconnect the PT from the main bus bars. The primary
connection shall be disconnected before the PT or its primary fuses become accessible.
Neutral point of the star connected PTs both on primary and secondary sides shall be
earthed. The PTs shall have an over voltage factor of 1.9 for 30 seconds and an
accuracy of class 1.0 from 10% to 120% of normal voltage. If not otherwise specified,
the secondary voltage of PTs shall be 110 V
1- 3 Phase cast resin horizontal draw out line potential transformer ratio 11
KV/√3:110/√3 Volt, class 1.0, 200 VA connected star/star with H.V. and L.V.
connections, H.V.fuses and LV MPCB of adequate rating to withstand fault level in PT
circuit, isolating plugs for H.V. and L.V. connection.
1- Strip heater to prevent absorption of moisture
Indicating Lamps:
Indicating lamps shall be of LED type. These should be provided with translucent
covers of red, green and amber colors as required. Bulbs and lenses shall be easily
replaceable from the front.
Protective Relays:
The relays shall be mounted on front door of the compartment and accessible for
setting and resetting from the front. Hand reset flag indicators visible from the front shall
be provided for electromechanical type relays. Details regarding requirement of relays
and their type, model etc. shall be as given in the data sheet/ feeder details.
The instrument and relay panel fitted with :
1- Square voltmeter of 96 x 96 mm scaled 0-15000 volt with 3 way and OFF selector
1- Square Ammeter of 96 x 96 mm scaled 0-150 amps with 3 way and OFF selector
1 no. energy analyser to measure voltage, current, power factor, frequency,kW/kVA,
kWh, kVArh, kVAh,Real time,date with communication module.
1 - no. circuit breaker control switch for electrical (T/N/C)
1- Triple pole numerical I.D.M.T. overcurrent & earth fault relay with two outer elements
connected for overcurrent protection and the middle element for earth fault protection
overcurrent setting 50% - 200% Earth fault setting 20% - 80% (51 and 51N)
1 - Electro mechanical Master trip relay (86)
1 - Electro mechanical Anti pumping relay (94)
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
1 - Trip Circuit supervision relay.
1- set of Red/Green indicating lamps for close and open position
1- Amber indicating lamp for auto trip
1- clear indicating lamp for trip circuit healthy
1- set of white indicating lamps one per phase
1 - blue indicating lamp for spring charged
1 - push button on front door for emergency trip
1- Four window annunciation display to indicate fault trip of incoming and outgoing
feeders including audio alarm hooter with accept push button, internal wiring,protection
fuses etc. complete.
1- cable box suitable for cable termination to receive 11 KV XLPE Cable 3 Core 120
With Power Pack:
If DC supply for the control circuit is not provided by the customer, a 230V AC / 110V
DC Power pack of ‘ALAN’ make shall be provided, where the input 230V AC to the
power pack shall be supplied by the customer. It is always better from technically and
protection safety wise to have your own DC supply from Battery Bank and Battery
Transformer Protective Devices
Wherever mentioned in the feeder details, necessary arrangement shall be provided by
the contractor in the VCB panel to facilitate connection of the following protection for the
transformer/motor.
AVA33 – Auxiliary Relay for transformer protection
Provision of interlocking safety shutter automatically closing when the VCB is racked
out from the service position.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be
wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal
strip rating shall be suitable for connecting two wires of 2.5 sqmm subjected to providing
minimum size strip suitable for 4/6sqmm.
161.01 Cost of (SINGLE PANEL) 11kV 350 MVA, 630 amps Vacuum circuit breaker (HT Panel)
indoor type fitted with arc control devices with CT rating shall be as per 630 KVA Set 1.00 748759.00 748759.00
Battery Charger Unit: -
162 Supply, design, unloading at site, shifting to location, installation, testing and
commissioning of 1 No. OEM manufactured automatic float cum boost (50 Amp) battery
charging equipment suitable for 110V, 200AH, VRLA with value regulated SMF lead
acid 110V (55 cells) 200AH SMF battery type 55 UPST200 of Exide / HBL make with
stand and standard accessories, conforming to degree of protection IP – 42, sheet steel
enclosure 14 SWG thick, with automatic voltage regulation, current limiting circuitry,
auto cut facility, smooth filter circuit switches, ammeter & voltmeter on DC side, RYB
indicating lamps (LED type) on AC side complete in all respect with float and boost /
buck charging, switchgear, Earthing, powder coated etc as required including one no.
distribution board having 63 Amps DP MCCB as incomer and 12 Nos. 20/16A DP
MCB's (D.C. duty) as outgoing complete as required and as per technical specifications.
Make:- HBL Power Systems Ltd. / AMARA RAJA / Power House/ Baid Power Services/
/Liveline. Battery:- Exide, Amar Raja, Quantum,HBL.
The Technical specification of Battery Charger shall as per company norms.
Note:- All technical specification and GA Drawing of battery charger shall be approved
by E/I or consulatant before final delivery. Inspection of the same shall be carried out at
company's factory before delivery.
Battrey & Battery Leads Charger
162.01 Total cost of Battery Charger with 110 volt 200 AH battery bank consisting of 55 nos
200 AH SMF VRLA Battery bank including rack, , Battery Leads and accessories etc. Set 1.00 605561.00 605561.00
163 630 KVA INDOOR LEVEL-1 I.S.1180TYPE, OLTC OIL COOLED TRANSFORMER:-
Supply, Receiving, Unloading, Storing, Shifting, fitting, fixing, commissioning and
testing of Continius Rating OLTC 630 KVA 11/0.433 KV Delta/Star, vector group
DYN11, Level-1 (IS:1180) Rating indoor Transformer. The OLTC + 5% to– 15% in
step of 1.25% throu’on load tap changing switch to vary secondary voltage within
limit, Oil Cooled, copper wound indoor transformer along with all accessories,
necessary instruments all main fittings provided for OLTC integrated RTCC Panel
Microprocessor based compact for single/double transformer operation AVR with 4 digit
display to indicate PT voltage in terms of 110V or 433V and as per IS:1180 including
HV termination box with air filled cable box suitable for 11KV 1 Run 3 Core 120 Sq mm
XLPE AL./AR./C and LV termination box with air filled cable box suitable for 1.1KV 3
Runs 3.5 Core, 300 Sq mm XLPE Al. Ar. Cable etc as required the 500KVA indoor
Transformer with all with accessories as per IS:1180, General Specifications of N.E.C.
/ I.E.R. etc as required. (Make:- Voltamp Transformer Ltd-Vadodara /Kirloskar
Note:- Technical specification of above OLTC indoor Type Transformer shall be
provided at the time of work order.
Apart- from the above standard fittings followings items should be included:-
1. Oil Temperature indicator with One Set of Contacts.
2. Winding Temperature indicator with One Set of Contacts.
3. Marshalling Box with complete wiring.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
4. Magnetic Oil Level Gauge with Contacts.
5. Bucholtz's Relay with set of Contacts and Shut off Valve.
Tests: - Routine test as per IS: 1180
Type Test: - Type test shall be conducted, if there is any charge then mention in the
Test Certificate: - Two Copies of test routine certificates have to be submitted along with
the OCTC Transformer.
Transformer Size:- As per conpany specification.
The technical specification of Transformers are as follows:-
Rating - 630 KVA
Installation - indoor
No of Phase - Three
Primary Voltage - 11 KV
Secondary Voltage - 433 V
Vector Group - DYN – 11
Taping Range in primary - + 5% to – 10% in 2.5 steps
Tap – Changer : OLTC + RTCC + AVR
Steps : 16 Steps / 17 Positions
Temp. Rise (Oil/Wdg.) : 50/55°C
Total Losses at 50% Load. :- 1.86 KW (Max)
Total Losses at 100% Load. : 5.3 KW (Max)
Impedance at 75 º C : 4.5% (subject to IS Tolerance)
Oil by Thermo Meter :- 50 Degree C.
Paint shade - Enamel Painting as per IS standard / Powder Coating / Conforms to IS
Insulation class - A
CRGO Core- M-3 Grade. In house Core cutting facility.
Fittings & accessories : Stem type OTI, R&D Plate, Explosion vent, Silica gel breather,
Plain Oil, Level gauge, Rollers, earthing terminal, 1 No drain cum sampling valve, 1 No.
First Filling of Oil - HV – Cable Box
Terminal Arrangement - HV side Cable Box- 3 Core 120 Sq. mm 11 KV cable LV –
Cable Box (For Multi Run Cable jointing arrangement - 4 Runs 300- Sq.mm 3.5 Core)
Copper loss & iron loss shall be as per IS:1180. and as per Level -2 Type Transformer.
The cost of foundationof Transformer is not included in above estimate. The foundation
work shall be as per IS:1180. level-2 manufracturer of Transforemr. The foundation
work (making a 150 mm thick RCC Platform, 300 mm above ground level in
Transformar Room. The size of platform shall be 8' (W) X 8' (L) X 6" (Thick) on 4 Nos.
10"X10" RCC columns, shunk 4 ft deep in ground and then earth filling (compacted as
required) along with required size & length of MS channels as per the dynamic load of
630KVA indoor Transformer or as per the company foundation guide lines. etc as
required (Make:- Voltamp Transformer Ltd-Vadodara / Kirloskar / Crompton)
163.01 Total Cost of 630 KVA 11/0.433KV Indoor Transformer of LEVEL-1 (IS:- 1180) Each 1.00 3134670.00 3134670.00
164 180 KVA 3 PH, Liquid Cooled Silent D.G. Set confirming to CPCB-II Norms With
Supply, unloading at site, shifting to location, fitting, errection and commissioning of 180
KVA D.G. Set, 415 Volts, 3 Ph. Silent Diesel Generator Set confirming to
IS:10001/10002 AC supply complete with engine (1500 RPM) and alternator DG Set
controller confiring to IS:13364 with accessories including residential type silencer and
fuel service tank 880 litres capacity, battery, nattery leads, battery charger with all
accessories, including MCCB of suitable rating & standard set of tools and anti-vibration
mounting pads, With AMF Panel etc. The power command controller compactable with
BMS, PC & PLC compelte as required, remote mointoring and data logging with digital
voltage regulator through inbuilt AVR, digital governing including protection complete as
required. Providing & installing the complete control cables between DG Set & Main LT
Panel to make system autiomatic complete as required. Rate shall be inclusive of all
items required for D.G. Sets exhaust system including M.S. pipes, insulation, M.S.
structure & accessories etc. and shall be compiled to ECBC-2007 norms, along with the
following accessories:- (Make:-KOEL-GREEN, Jackson, Kohlar) (Engine:- Kirloskar,
Sterling & Wilson Powergen Pvt. Ltd./Jakson/ KOHLER-Nevistar & Alternator-
Crompton, Jyoti, Kirloskar, Stampford) (Warenty-2 Years)
(The Seprate Company Make(OEM) AMF Panel Provision of Auto Start Auto OFF,
Should Have Suitable Caacity of Braker (315A/FP/36kA, MCCB- Microprocessor
relleased based), with auto load sharing and auto start system, PLC , NO/NC
Contactors, AMF Controler, Relays, Digital Measuring Meter, CT Indicaters RYB , One
of trip indications as per the CPCB-ll Nomes
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
Supply of acoustic enclosure for 180 KVA CPCB approved Acoustic enclosure with 80
mm MS base plate, 2 mm CRCA sheet, 50 mm thick foam / 100 mm Rock Wool
Insulation, 14 surface tank treatment, dully powder coated and painted with Briliant Blue
colour with integrate Fuel Tank, services door, louvers (Fresh Air / Radiator), 1020 dia
residential type Silencer, approx dimension L x W x H - as per norms. Complete with
following accessories :-The civil part RCC platform for above 180 KVA Silent DG set
costing is not inclusive. (Platfom Size- 150 mm thick 6000mm X 3000mm RCC
foundation as DG Platform.)
b) Batteries, battery leads and battery charger.
c) Residential Silencers.
d) First fill of lube oil.
f) KEY POWER generator controller with auto load management card I
In above supply item following work are also included :-
i) Installation, fitting, fixing, testing and commissioning of the same.
ii) RCC foundation as per company norms for commissioning of D.G. Set. (Cost of civil
part is not included like RCC Foundation). For that supplier of DG Set shall provide
detail G.A. drawing & foundation drawings.
iii) Installation of Standard Exhaust system for Silent D.G. Set shall be as per Central &
State Pollution Board Norms along (C.P.C.B.).iv) Test run for D.G. Set without load and
with load (part wise ) at least 3 hrs each time. Test Run shall be in Vendor's Scope.( 1).
in 50% load, 3hrs. (2) in 100%
load, 3 hrs.(3) One hr. in 110% load) (in the scope of DG Supplier)
164.01 Total Cost of 180 KVA SILENT DG SET Set 1.00 2402653.00 2402653.00
165 MAIN LT PANEL
Supplying, designing, manufacturing, Unloading at site , shifting to location, fitting,
fixing, installation, testing and commissioning of Main LT Panel, fabricated out of
2mm thick (14 SWG) CRCA sheet steel IP:42, (dust and vermin proof) with
reinforcement of suitable lifting arrangement effecting proper connection of all incomer
and outgoing, floor mounting type , fixed on base channel of 100mm x 100mm x 6mm
or ISMB100 (100x100x6mm), which will have incoming 3 phase power supply from
Campus Transformer.
The sheet steel shall under go minimum of 7 tank treatment followed by finished powder
coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50
Cy, and fault level 65 KA with front operated construction including separate fabrication
arrangement for fixing A.C.B. The incoming ACB and higher range out going MCCB
must have bus arrangement for termination of multi run cables.
The panel shall be provided with a thermostatically controlled heating arrangement (200
W) to take care of high humidity conditions. A 6/16A socket with sitch as service outlet
(single phase) and 1 no. 10W LED LAMP with holder shall be provided in one of the
compartments as service outlet in the panel. The complete panel shall be fuse less
type, for control circuits 2A SP MCB's to be used.
Main LT Panels shall have 20% spare outgoing feeders for different rating of feeders.
The Panels shall be preferably arranged in multitier formation. The size of the panel
shall be designed in such a way that the internal space is sufficient for hot air
movement, and the electrical component do not attain temperature rise more than 40
degree Celsius.
All openings shall be covered by soft rubber gasket (metal based neoprene) having
structural re-inforcement with suitable Angle/Channel/T/Flat sections, hinged and
lockable doors enclosure shall be galvanized. This main panel must be extendable for
future requirement in such a manner not to disturb ongoing services at the point of use
during extension.
The pannel shall be interlocked with switchgear such that no door can be opened when
the switch is in ON position.The switch gear shall have mechanical arrangement for
interlock defeat.The design of panel shall be such as to offer maximun safety and ease
of maintenance.
The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking
arrangement, with trip setting as per load requirement with short circuit & over current
protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of
Micro processor and thermo magnetic category type.
AL. BUS BAR SECTION:-
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
The panel includes 415V, 1500A, 3Ph, 50KA, 50Hz, TPN Electrolytic Aluminium Bus
Bar (E91E) GI Earth Bus with removable glands plates, cable glands at sending and
receiving ends, including connection with outgoing feeders complete in all respects. The
electrolytic Aluminium bus bar as per I:S 5082 of suitable length and insulated by heat
shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of
bus bar shall be minimum 0.8 A / sq mm. Minimum clearance between live parts /
neutral to earth shall be 19mm. However clearances between terminals at components
shall be as per applicable individual standard for components. Interconnections
between the main bus bars and individual units shall be made using vertical / horizontal
Bus Bar to individual MCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire
with 63A 4 studs (Brass) treminal block, aluminium bus bars of adequate rating. AL. Bus
Bar will be supported on insulators made of non-hygroscopic, non-inflammable material
with tracking index equal to or more than that defined in BIS.
Contractor will provide shop drawing SLD & GA drawing along with BOM with CAT. No.
of each and every components and switch gears of LT Panel for approval of
Consultant. Panel bulder should visit the site before manufacturing the LT Panels.
Inspection of the LT Panel shall be carried out at Panel Builder's factory by the
Consultant before final delivery for that all arrangements shall be made by the
The above panel consisting of the following:-
All kA ratings shall be Ics values. All MCCB,shall be Icu = Ics and values,shall not be
less than 100% Icu.
The incoming ACB in panel capacitites as 45 degree aqmbient temp. The incoming
ACBs shall have 5 NO and 5 NC contacts. All relays to be operated at 240V,Single
Phase,50Hz AC supply.
The incoming ACBs shall have following equipments provided the details of auxiliaries
that are fitted in the ACB should be visible from the outside.
1) 1 No. 240V AC shunt release
2) 1 No. 230V AC closing coil
3) 1 No. Digital voltmeter & Am-meter with selector switch.
4) 3 Nos. in each set of CTs 1600/5A, Cl-1 15 VA for metering.
5) 240V AC, indicating lamps with 2 Amp MCB protection to indicate open, close, trip for
ACB (ON/OFF & TRIP)
6) TNC Switch to close the ACB.
7) R, Y and B LED phase indicating lamps with 2 Amp control SP MCB.
8) In Built Digital multi-function meter suitable for true RMS metering. Meter should
measure line and phase voltage, current of all 3 phase and neutral,
Hz,PF,KW,KWH,KVAR, KVARH ,KVA, KVAH,Voltage and current including 1 set of C.T
with RS:485 port or load manager.
9) CT shorting links.
(a) Direct Acting O/L.
(b) With Individual time adjust for pick up – S/C and E/F. with Microprocessor based
release (with long time, short time protection with adjustable pick up and time delay and
instt. Protection.
(c) Digital display for current and time adjustment of each protection with in-bulit li
battery back up.
(d) Remote modification of settings.
(e) Suitable for operation on 415V A.C.B. will be of same make with minimum 20 trip
(f) Will have Shunt Trip, Overload Release, Short Circuit Release, Earth Fault Relay,
AUX. contact and AUX. Relay, Over Voltage, Under Voltage protection.
ICU=ICS=ICW=1SEC.
(g The incomer A.C.B. shall be machinically operated drow out type and with
Microprocessor communicable release.
(h) Provision of Intelligent inbuilt Modular Meter in incomer feeder ACB covering 25
electrical parameters with RS 485 port. (consisting of Voltage, Amps, kWh, kW,
P.F. Hz etc parameter).
(i) The incomer ACB shall be Electrically operated drawout type and with
microprocessor communicable release, communication system with data and breaker
shall be of BSS type.
(j) All outgoing MCCB shall be as per the specification prescribed in BOQ & Drawiongs
with LED indicators RYB.
kl) All breaker handlings truck shall be provided by the supplier.
All 4 pole MCCB with microprocessor based release must have following
characteristics:-
1. Pre alarm LED signal under over load.
2. Over heat signal when inernal temp. reaches 75 degree C.
3. Separate LED fault indicator for each fault.
4. Logic selectivity (inbuilt delay 0f 50 ms beteen upstream and down stream breaker)
5. Adujustable neutral pole.
6. Non sensitive to temp. veriation.
7. Control of load (only selective one)
8. With positive Isolation Marked.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
9. With 8 steps adjustable short circuit and over load current and with earth fault
10. Line load inerchangeable.
11. As per IEC 60947-2.
All 4 pole MCCB with thermomagnetic based release must have follwing
characterstics:-
1. Icu=100% Ics.
2. With positive Isolation Marked.
3. With adjustable short circuit and over load.
4. As per IEC 60947-2.
Incomer and all out going feeders (up tp 160 A) must have phase indications and
ON/OFF/TRIP indications. Selection of switch Gears shall be decided by the E/I or the
Make of Switch Gears ACB- L&T U power Omega with MTX 3.5 and above, Legrand
DMX³-MP-4 Series, Siemens-3 WL-ETU-27B Onwards, Schneider Master Pack NW,
ABB- EMX-TR- 1,2 3
Make of MCCB - L&T - D shine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL/ ABB-
Make of MCB - (10kA-C-Series.) L&T U Version/ Legrand-Dx³/ Schneider-Acti-9 /
Siemens-Beta Guard/ABB SH Series.
The Name Plate for each incoming & outgoing feeder must be in Anodized Aluminium
Location :- In Panel Room (Sub- Station Building).
Panel Size - As per Drawing submitted.
1 Set cost of Fabrication part of Main LT Panel & busbar system, in CRCA Sheet Steel
enclosure (IP-42) without any componentsP & its busbar system, in CRCA Sheet Steel
enclosure without any components. Name of Panel Builder :- EAP- Kolkata/ AC Power,
kolkata, / JMD ELECTROTECH, Kokar, Ranchi/ Mirco Cosmic Engineering, Patna /SPC
Electrotech Pvt. Ltd / Meditron, Meshra, Ranchi/ Shivalic Power Control Pvt. Ltd . Panel
Builder must be CPRI approved of required Amp.)
1 Set Multifunction Meter having (5000 Series) LED meter display accuracy Class 1
as per IEC 62053-21, should have an active RS-485 port, in built RTC, Aux Supply:
44-277Vac/dc. Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh,
Runhrs, Onhrs Interrupts, THD for V&I per phase, individual harmonics for V&I upto
15th level complying with IEC61557-12. Min/Max for eight parameters. Sampling rate:
64 samples per cycle. Make:- L&T, Schneider, Legrand.
3 nos. CT 1250/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa /
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer &
outgoing.Make-L& T./ AE/ Rishav, Kaycee
1 No. 1250A FP / ACB EDO type with Handle with adustable microprocessor release
and all other release as mentioned above (50 KA). The ACB shall be with front
handllings truck and spreader links & with ON-OFF-TRIP Indications and electro
magnetic interlocking arragement. (Size of Cable- 4 R-3.5 C 300 Sq. MM.AL. AR.
XLPE Cable.) ACB Must mave extended Bus Arrangement for termination of Multiple
OUT GOING FEEDERS
1 No. 630A FP/36KA, MCCB with adjustable Thermo-magnetic release type with S/C,
O/L protection with extended front rotary handle & spreader links with ON OFF & trip
facility. (2R, 300 sq.mm. Al./Ar. XLPE Cable) For LT. Panel Main Building.
3 set 400A FP/36KA, MCCB with adjustable Thermo-magnetic release type with S/C,
O/L protection with extended front rotary handle & spreader links with ON OFF & trip
facility. 1 no. for Boys Hostel, 1 no. for Girls' Hostel & 1 no. for APFC Panel (1R, 300
sq.mm. Al./Ar. XLPE Cable). .
2 set 250A FP MCCB (25KA) thermomagnetic release type with S/C & O/L protection
and with front rotary handle & spreader links . (future Use)
2 set 125 A FP MCCB (25KA) thermomagnetic release type with S/C & O/L protection
and with front rotary handle & spreader links . 1 no. for VTPN DB of Sub-Station
Building and 1 no. as spare) Cable size - 1 R 50 Sq. MM 3.5 C Al. Ar.Cable
2 set 100A FP MCCB (25KA) thermomagnetic release type with S/C & O/L protection
and with front rotary handle & spreader links . 1 no. for external lighting Panel and 1 no.
2 sets 63A FP MCCB (25KA) thermomagnetic release type with S/C & O/L protection
and with front rotary handle & spreader links. (as future use)
4 nos. 32A DP MCB C-Series 10kA ( 2 nos. for Sub Station Building Outer Lights & 2
nos. as Spares)
2 nos. 25A FP MCCB (25KA) thermomagnetic release type with S/C & O/L protection
and with front rotary handle & spreader links. (2 nos. as spare)
165.01 Total Cost of Main LT Panel Set 1.00 1128021.00 1128021.00
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
166 A.P.F.C. Panel (Capacitor Bank) Auto Mannual Type (APFC) Panel –300 KVAR +
(10x2=20 KVAR) as fixed capacitor Bank) 12 Stage Capacitor Bank Details with
mixed dielectric Ultra Heavy Duty Capacitors of following range :-
Supplying, designing, manufacturing, installation, shifting in location, testing and
commissioning in correct alignment position, effecting proper connection of all incomer
and outgoing of A.P.F.C. Panel (Capacitor Bank / Auto Mannual) of 14 SWG CRCA
sheet (2 mm) steel IP –43 floor mounting cubical type Capacitor Bank Panel suitable for
operation on 415V, 50Hz, 3 Ph. AC supply and fault level 50kA with approximate with
front operated construction including separate fabrication arrangement for fixing MCCB,
, M.C.B., Capacitors, Contactors etc.
The sheet steel under go minimum 7 tanks treatment followed by finishing powder
coating of minimum 60 micron thickness duly compartmentalized with locking
arrangement duly fixed on Base Channel with proper lifting arrangement size – 50 mm x
50 mm x 6 mm or ISMB50 (50x50x6mm) having accessories mounted inside the
cubical panel, earthing with 2 Nos. earth studs and Capacitors having earthing
All openings shall be covered by soft rubber gasket, enclosure shall be galvanized.
The panel shall have type test certificates with short circuit and IP protection (C.P.R.I.
AL. BUS BAR SECTION:-
The panel includes 415V, 500A, 3Ph, 50kA, 50Hz Electrolytic Aluminium bus bar of
grade 63401 WP as per I:S 5082. The current density of Aluminum shall not be
more than 0.8 Amps/sq.mm cross sectional area of Bus Bar. Aluminiu Bus bar shall
be with removable glands plates, cable glands and sending and receiving ends,
including connection with outgoing feeders complete in all respects. The support for
busbar shall be nonhygroscopic non inflammable epoxy cast resin insulators. The
minimum clearance between live part shall be 35-40mm. The Aluminium bus bar shall
be with heat shrinkable PVC Slived Red,Yellow,Blue & Black as (RYB & N ) after
temperature and incloser derating maximum allowable temp.of bus bar shall be 90
Contractor will provide shop drawing SLD & GA drawing along with BOM with CAT. No.
of each and every components and switch gears of LT Panel for approval of
Consultant. Panel bulder should visit the site before manufacturing the Lt
Panel.Inspection of the LT Panel shall be carried out at Panel Builder's factory by the
Consultant before final delivery for that all arrangements shall be made by the
Make of MCCB - L&T D-Sine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL/ ABB-T
Make of MCB - (10kA-D-Series.) L&T U Version/ Legrand-Dx³/ Schneider-Acti /
Siemens/ABB SH Series.
Make of all switch Gears and other components of above panel shall be decided be the
consultant (elec,) / E/I.
The Name Plate for each incoming & outgoing feeder must be in Anodized Aluminium
Location :- In Panel Room.
Panel Size - As per Drawing submitted.
1 Set cost of Fabrication part of APFC Panel & busbar system, in CRCA Sheet Steel
enclosure (IP-42) without any componentsP & its busbar system, in CRCA Sheet Steel
enclosure without any components. Name of Panel Builder :- EAP- Kolkata/ AC Power,
kolkata, / JMD ELECTROTECH, Kokar, Ranchi/ Mirco Cosmic Engineering, Patna /SPC
Electrotech Pvt. Ltd / Meditron, Meshra, Ranchi/ Shivalic Power Control Pvt. Ltd . Panel
Builder must be CPRI approved of required Amp.)
1 Set Multifunction Meter having (5000 Series) LED meter display accuracy Class 1
as per IEC 62053-21, should have an active RS-485 port, in built RTC, Aux Supply:
44-277Vac/dc. Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh,
Runhrs, Onhrs Interrupts, THD for V&I per phase, individual harmonics for V&I upto
15th level complying with IEC61557-12. Min/Max for eight parameters. Sampling rate:
64 samples per cycle.
3 nos. CT 400/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa /
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer &
outgoing.Make-L& T./ AE/ Rishav, Kaycee
1 set 400A FP MCCB (36KA) with adustable themo- magnetic release type with S/C &
O/L protection with extendede front rotary handle and spreader links. (Cable Size- 1 R-
300 Sq. mm 3.5 C Al. Ar.Cable)
1 No. Power factor correction Intelligent controller Relay (dual Sense- Relay)with 12
steps and multi -functional display ,APFCR with 12 steps. The relay shall be sensitive to
pick up 1% of rated current and correct the P.F accordingly. Also the relay shall display
individual system harmonic level. Make:- L&T, Legrand, Schnider, Epcos.
1 no. VAF + Power Factor, 3Ph, Class 1, 5A, CAT. No. WL4110010OOOO, Meter
14 Sets. ON/OFF PUSH Button for manual operation of contactors. Make- L & T/C&S
(12 +Fixed Capacitor Bank also)= 14 Sets.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
(Note:The contractor may select the next higher fault rating of MCCB if it is not readily
available ,without any extra cost ,as the figure indicated within the bracket or slash are
required minimum fault level of the panel.)
Bill of Material in A.P.F.C. Panel :-
3 nos. 20A TP / MCB / 10kA (D tripping characteristic) for 10 KVAR Capacitor. (for
2 nos. 25A TP / MCB / 10kA (D tripping characteristic) for 15 KVAR Capacitor. (for
2 nos. 40A TP / MCB / 10kA (D tripping characteristic) for 20 KVAR Capacitor. (for Step-
2 no. 63A TP / MCCB / 25kA with thermomagnetic release based 40 deg (for Step-8 &-
9) (2 set 25 Kvar) for 25 KVAR Capacitor. (MCCB with Speader links & front rotary
3 Nos. 125A TP /25kA/MCCB T.M 40 deg (for Step-10 to Step-12) (3 set
50Kvar)(MCCB with Speader links & front rotary handle).
1 no. 6A - DP MCB.(D tripping characteristic)
1 no. 6A - 4P MCB.(D tripping characteristic)
Auto Mannual Type (APFC) Panel – 300 KVAr 12 Stage Capacitor Bank Details with
following parameters :-
1. MPPXL ,440V/50Hz,TP Shunt mixed dielectric Ultra heavy duty Capacitor.
2 Lower operating losses - 0.35W/KVAr).
3. Over current withstand capability - 1.8 times rated current.
4. Inrush current withstand capability - 300 times rated current.
5. Operating Life- 130000 hours.
6. Numbering of switching- 15000 operations per year.
7. Insulation Class H.
Make of Capacitors: (Ultra Heavy Duty Capacitors) Box Series Make:-Legrand /
L&T/Schneider/Epcos
3 nos. (10 x 3) x 3 Set = 30 KVAr (Power Capacitor).
2 nos. (15 x 2) x 2 Set = 30 KVAr (Power Capacitor).
2 nos. (20 x 2) x 2 Set = 40 KVAr (Power Capacitor).
2 nos. (25 x 2) x 2 Set = 50 KVAr (Power Capacitor).
3 nos. (50 x 1) x 3 sets =150 KVAr (power Capacitor)
Total - 300 KVAR
Capacitor Duty Contactors :- Make:-L&T /Schneider/Legrand/ Siemens.
3 nos. For 10 Kvar – NO-NC type Contactor (415V,3PH,50 cycle)
2 nos. For 15 Kvar – NO-NC type Contactor (415V,3PH,50 cycle) .
2 nos. For 20 KVAr –NO-NC type Contactor (415V,3PH,50 cycle)
2 nos. For 25 KVAr –NO-NC type Contactor (415V,3PH,50 cycle).
3 nos. For 50 KVAr –NO-NC type Contactor (415V,3PH,50 cycle).
1 Set. (10 x2)=20 KVAr Ultra Heavy duty Capacitor for fixed Capacitor Bank with all
required accessories like 2 nos. 25A, 10kA, TP D SERIES MCB with 1 no. 63 A TP
MCCB /25 kA, thermo magnetic release type as incomer for fixed Capacitor Bank
capacitor, NO-NC contactor, ON OF indicators, ON OFF Push Button for Manual
Operation of Contactor etc. shall be fixed capacitor to take care of the no load losses of
the transformer.
166.01 Total Cost of APFC Panel Set 1.00 894803.00 894803.00
167 External Lighting Panel :-
Supplying, designing, manufacturing, installation, shifting in location, testing and
commissioning in correct alignment position, effecting proper connection of all incomer
and outgoing of external Lighting Panel of 14 SWG CRCA sheet (2 mm) steel IP –42
floor mounting cubical type LT Panel suitable for operation on 415V, 50Hz, 3 Ph. AC
supply and fault level 25 KA with front operated construction including separate
fabrication arrangement for fixing M.C.C.B.
The sheet steel shall under go minimum of 7 tank treatment followed by finished powder
coating of minimum 60 micron thickness and suitable for operation on 415V / 3 Ph / 50
Cy, and fault level 65 KA with front operated construction including separate fabrication
arrangement for fixing A.C.B. The incoming ACB and higher range out going MCCB
must have bus arrangement for termination of multi run cables.
The panel shall be provided with a thermostatically controlled heating arrangement (200
W) to take care of high humidity conditions. A 6/16A socket with sitch as service outlet
(single phase) and 1 no. 10W LED LAMP with holder shall be provided in one of the
compartments as service outlet in the panel. The complete panel shall be fuse less
type, for control circuits 2A SP MCB's to be used.
Main LT Panels shall have 20% spare outgoing feeders for different rating of feeders.
The Panels shall be preferably arranged in multitier formation. The size of the panel
shall be designed in such a way that the internal space is sufficient for hot air
movement, and the electrical component do not attain temperature rise more than 40
degree Celsius.
All openings shall be covered by soft rubber gasket (metal based neoprene) having
structural re-inforcement with suitable Angle/Channel/T/Flat sections, hinged and
lockable doors enclosure shall be galvanized. This main panel must be extendable for
future requirement in such a manner not to disturb ongoing services at the point of use
during extension.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
The pannel shall be interlocked with switchgear such that no door can be opened when
the switch is in ON position.The switch gear shall have mechanical arrangement for
interlock defeat.The design of panel shall be such as to offer maximun safety and ease
of maintenance.
The MCCB's shall be Ics = 100% Icu, with rotary handle, spreader links & pad locking
arrangement, with trip setting as per load requirement with short circuit & over current
protection. The breaking capacity specified is Ics=Icu value. All MCCB's shall be of
Micro processor and thermo magnetic category type.
The panel builder shall have type test certificates with short circuit and IP protection
(C.P.R.I. Test)
Aluminum Bus Bar for Panel :-
Bus bar shall be suitable for 160A, TPN busbar chamber of suitable length with
(E91EWP) Eletrolytic Aluminum busbars. All busbars and interconnections shall be of
suitable size Aluminum busbar, current density of Aluminum shall not be more
than 0.8 Amps/sq.mm cross sectional area of Bus Bar with removel gland plates,
cable glands, at sending and receiving ends, encluding connections with outgoing
feeders complete in all respect and all interconnections shall be made with 2.5, 4 and 6
sq.mm. PVC Cu.wire. Cost of Enclosure with Al bus bar, connection PVC wires, etc.
The Aluminium bus bar shall be with heat shrinkable PVC Slived Red,Yellow,Blue &
Black as (RYB & N ) after temperature and incloser derating maximum allowable
temp.of bus bar shall be 90 degree C.
Contractor will provide shop drawing SLD & GA drawing along with BOM with CAT. No.
of each and every components and switch gears of LT Panel for approval of
Consultant. Panel bulder should visit the site before manufacturing the LT.
Panel.Inspection of the LT Panel shall be carried out at Panel Builder's factory by the
Consultant before final delivery for that all arrangements shall be made by the
Make of MCCB - L&T D-Sine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL/ ABB-T
Make of MCB - (10kA-C-Series.) L&T U Version/ Legrand-Dx³/ Schneider-Acti /
Siemens/ABB SH Series.
Make of all switch Gears and other components of above meter panel shall be decided
be the consultant (elec,) / E/I.
The Name Plate for each incoming & outgoing feeder must be in Anodized Aluminium
Location :- In Panel Room (Sub- Station Building).
Panel Size - As per Drawing submitted.
Bill of Material in External Lighting Panel :-
1 Set cost of Fabrication part of LT Panel & busbar system, in CRCA Sheet Steel
enclosure (IP-42) without any componentsP & its busbar system, in CRCA Sheet Steel
enclosure without any components. Name of Panel Builder :- EAP- Kolkata/ AC Power,
kolkata, / JMD ELECTROTECH, Kokar, Ranchi/ Mirco Cosmic Engineering, Patna /SPC
Electrotech Pvt. Ltd / Meditron, Meshra, Ranchi/ Shivalic Power Control Pvt. Ltd . Panel
Builder must be CPRI approved of required Amp.)
1 Set Digital Am-meter (0 – 100A) 96mmx96mm with 4-position selector switch for
incomer. Make- L& T./ AE/ Schneider. Make- Kaycee/L&T/Schneider.
1 Set Digital Voltmeter (0 – 500V) 96mmx96mm with 4-position selector switch for
incomer. Make-L& T./ AE/ Schneider. Make- Kaycee/L&T/Schneider.
3 nos. CT 100/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa /
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer &
outgoing.Make-L& T./ AE/ Schneider.
1 no. 100A FP MCCB (25kA) with adjustable thermomagnetic release type with S/C &
O/L protection with front rotary handle and spreader links. (Incoming cable size –1
Runs 50 Sq mm 3.5 Core Al. Ar. Cable).
5 nos.25A/FP/16KA/ MCCB thermomagnetic release type, and S/C , O/L protection,
with Rotary Handle & Spreader links.
3 nos. Power Contactor NO NC of three phase of suitable rating. Make:- L&T /
Siemens/Legrand
3 nos. Astronomical Alpha Rex³ single channel Timer. Make:- Legrand CAT No.
412654 / Siemens
3 nos. Four pole two way Lexic changeover with centre off 440V AC 32 to 40A to be
used in case of timer failure to by pass the timer. (LEGRAND CAT No. 604022)
4 nos. 32A DP MCB C Series of 10 kA
167.01 Total Cost of External Lighting Panel Set 1.00 208353.00 208353.00
168 Feeder For Fire Fighting System :- Supply, fitting, fixing of 250A FP / 36kA MCCB
(thermomagnetic release type) with rotary handle & spreader links and 250A four pole
on load Change changeover along with enclosure. (Separate arrangement direct from
Transformer to fire fighting pump panel) Make of MCCB - L&T D-Sine/ Legrand DPX³ /
Schneider-NSX / Siemens - 3WL/3VL. Make of changeover-L&T.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
1 Set cost of Fabrication part of wall mount feeder for fire fighting & busbar system, in
CRCA Sheet Steel enclosure (IP-42) without any components & its busbar system, in
CRCA Sheet Steel enclosure without any components. Name of Panel Builder :- JMD
Electrotech, Kokar, Ranchi/ Mirco Cosmic Engineering, Patna /SPC Electrotech Pvt. Ltd
/ Meditron, Meshra, Ranchi or any approved Panel Builders of above make Switch
1 no. 250A FP/36kA MCCB with spreadr links and front rotary handle
1 no. of 250A /Fp/TPN) ON Load changover without enclosure (Panel Mounted- Open
168.01 Cost of wall mount panel for Fire Fighting Feeder Enclosure with components Set 1.00 95431.00 95431.00
169 Supply Fitting Fixing and testing of 63 A TP MCB C Series 10kA Each 2.00 2160.00 4320.00
170 Supply Fitting Fixing and testingof 63 A FP MCB C Series 10kA Each 2.00 2714.00 5428.00
LT CABLE 1.1 KV
171 Supply of following size of 1.1KV XLPE / PVC Insulated / PVC sheathed (Heavy Duty)
armoured electric cable with aluminium conductor as per IS 7098 (Part-1) 1988 with
upto date Amendments. Make:- As per approved Make List (Make:- Havell’s, Finolex,
172 Supply of following size of 11KV XLPE / PVC Insulated / PVC sheathed (Heavy Duty)
armoured electric cable with aluminium conductor as per IS 7098 (Part-2) 2011 with
upto date Amendments. (Make:- Havell’s, Gloster, Finolex, KEI)
172.01 Supply of 3 Core 120 Sq. mm. XLPE PVC Al. / Ar. Cable 11 KV Mtr 190.00 2384.00 452960.00
Sub-Station Auxiliaries:-(CONTROL CABLES)
173 Sub-Station Auxiliaries:-(CONTROL CABLES):- Supply, laying, testing of 660V grade
copper conductor XLPE insulated sheathed Armoured multicore control cable for
various control requirement, including GI spacer, saddle for support end termination
with cable gland etc, complete as specified in Sub-Station Area. Make:- Havells, KEI,
Gloster, Finolex.
173.01 2 C x 1.5 Sq mm Copper Armoured Cable (2XWY/2XFY) Mtr 100.00 157.00 15700.00
173.02 3 C x 1.5 Sq mm Copper Armoured Cable (2XWY/2XFY) Mtr 75.00 194.00 14550.00
173.03 10 C x 2.5 Sq mm Copper Armoured Cable (2XWY/2XFY) Mtr 30.00 701.00 21030.00
174 Supplying and laying ISI marked following electric insulating mats of 11/3.3 KV working
voltage grade of approved make as per IS-15652-2007 amended up-to-date complete
as required & approved by Engineer Incharge. Make:- As per Approved DBR make list.
174.01 Cost of electric insulating mats of 11/3.3 KV working voltage grade of approved make
as per IS-15652-2007.
174.02 Supplying & Laying 12mm thick chequered rubber matting of 1.1.kv 1 m wide of tested
quality to with stand 15KV dielectric strenght of approved make as per IS-5424-1969. Sq.Mtr. 10.00 1092.00 10920.00
174.03 Supplying of fire buckets of 10 liters Capacity of approved quality, painted white from
inside and red outside and having inscription "FIRE" in white conforming to I.S.
2546/1974 duly amended upto date complete as required & approved by Engineer
174.04 Supplying and fixing of MS pedestal stand heavy duty with rain protection cover as
required suitable for supporting Six fire buckets as required for fire fighting system & Set 1.00 6174.00 6174.00
approved by Engineer Incharge.
174.05 Supplying and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS
15683 with cylinder duly charged of capacity 4.5kgs. including fixing clamps, brackets, Each 2.00 4817.00 9634.00
bolts and nuts etc. as required & approved by the Engineer Incharge.
174.06 Supplying and fixing 10kg capacity Modular Automatic Fire Extinguishers dry chemical
powder nitrogen type pre-set at works ranging from 57 deg C/ 68 deg C/ 79 deg C fire
extinguishers conforming to IS 15683 including fixing clamps, brackets, bolts and nuts Each 1.00 11331.00 11331.00
etc. complete as required & approved by the Engineer Incharge.
174.07 Supply and fixing of shock treatment/ restoration charts written in Hindi/ local language
and English duly framed and covered with 3.0 mm glass as required.
174.08 Supply of First Aid Box made of 16 SWG MS Sheet duly painted within inside and
outside surfaces with one coat of primer and two coats of synthetic paint of required
shade comprising the following minimum but not limited, minimum 1 No. band aid
bandage 150mm, 1 No. Savlon Soap 30 ml, 1 No bottle Betadine 30 ml, 1 No Packet
dressing material etc. as required, approved by Indian Red Cross / St. John's
conforming to IS:2217.
174.09 Supply of 440V grade Rubber Hands Gloves. As per IS:4770- 1991. Pair 2.00 882.00 1764.00
174.10 Supply of 1 pair 12 KV rubber hand gloves of approved make, as per IS:4770- 1991. Pair 1.00 1425.00 1425.00
174.11 Supplying of Caution Boards manufactured out of 16 SWG, MS sheet of 450mmx
300mm size duly painted white and having `MAN ON LINE' and 'DO NOT SWITCH ON'
written in Red complete with hanging arrangement as required and & approved by the
Engineer Incharge.
SL No. DESCRIPTION UNIT QNTY RATE AMOUNT
174.12 Supply and fixing position the approved single line diagram framed in 1000 x 800 mm
size glass frame and installed in main switch room.
174.13 Providing, fitting, fixing, fabricating, erecting of MS angle of section 50 mm x 50 mm x 6
mm size for Brick wall trench to make support for MS iron plate to be fixed on every Each 20.00 575.00 11500.00
after 300 mm in RCC trench.
174.14 Providing, fitting, fixing, fabricating, erecting of MS Plate of 12 mm thick for covering
Brick wall cable trench in panel room on the support of iron angle each piece of MS
plate shall be 900 mm (W) x 300 mm (L). (To cover the Brick wall cable trench in panel
175 Octagonal Hot Dip Galvanized pole
175.01 Supply, fitting,fixing, erection and testing of 8 mtr Height Octagonal Hot Dip Galvanized
pole ( BOP-9030) with top dia 70 mm. bottom dia A/F 155 mm and made of 3 mm thick
sheet, along with base plate dimensions 260x260x16mm (L x B x T) small door opening
for juction box mounting with 2A DP MCB Ceries, 10kA, and 35 A Four pole connector,
cement concrete of 1:3:6 including excavation, refilling and suitable size foundation
bolts with template and all coplete job as required (But without pole collar & without
Arm). Make- Valmount, Transrail Lighting Ltd, R.R. Ispat, .
175.02 Supply fitting, fixing of 1 Mtr Single Arm Suitable for 70 mm Top Make- Valmount,
Transrail Lighting Ltd, R.R. Ispat,
175.03 Supply fitting, fixing of 2 Mtr Double Arm Suitable for 70 mm Top Make- Valmount,
Transrail Lighting Ltd, R.R. Ispat,
175.04 Supply, fitting,fixing, erection and testing of 4 mtr Height Octagonal Hot Dip Galvanized
pole( BOP-9030) with top dia 70 mm. bottom dia A/F 130 mm and made of 3 mm thick
sheet, along with base plate dimensions 220x220x12mm (L x B x T) small door opening
for juction box mounting with 2A DP MCB Ceries, 10kA and 25 A four Pole connector,
cement concrete of 1:3:6 including excavation, refilling and suitable size foundation Each 32.00 21943.00 702176.00
bolts with template and all coplete job as required (But without pole collar & without
Arm) with 50 mm G.I. Shocket arrangement to fix post top Led lamp) . Make- Valmount,
Transrail Lighting Ltd, R.R. Ispat,
175.05 ADD 2 % as miscelinious expenditure for HT Line connections, and necessary fee for
cerification from State Electricity Board and State Electrical Inspector Office
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
BOQ.pdf
Tender Document
GCC CONTRACTING.pdf
Tender Document
Drawings Site Plan.pdf
Tender Document
MAKE LIST.pdf
Tender Document
SCC.pdf
Tender Document
Physical Milestone.pdf
Tender Document
Signed IP.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .