Shri Ravinder Kumar AGE CONTRACTS
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
SPECIAL REPAIRS IN BLDG NO T 31 OF 169 MED REGT, P 01, 02 AND 09 OF 340 MED REGT, P 05 OF 296 FD WKSP AND OTHER SANCTIONED WORK AT AURANGABAD UNDER GE(S) AHMEDNAGAR
2020_MES_314405_1
8675/E8
Open Tender
Miscellaneous Works
Item Wise
180 days
AURANGABAD
Class D cat a (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹84,000
Yes
13 Feb 2020
13 Jan 2020
10 Feb 2020
13 Jan 2020
8 Feb 2020
27 Jan 2020
13 Jan 2020 - 18 Jan 2020
Amount
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of timber scantling over 40 Sqcm in section, in any position (unframed work) etc complete all as specified and directed.
PCC 1:2:4, type B1 using 20mm graded aggregate as in copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc. complete all as specified and directed.
Roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
Rolled mild steel plates (plain or chequerred) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - O or Fe 310 - O complete all as specified and directed.
Mild steel screw bolts of 15 mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10 cm long complete all as specified and directed.
Preparation of new steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed.
Mild steel wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling wall and ceiling boards (Fiber, pulp, Insulation) or insulation boards/ slabs/ blankets, any thickness incl cover fillets etc complete all as specified and directed.
GI frame work of size of grid 605 x 605mm for seamless ceiling comprising of GI perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx, 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 600 mm centre to centre including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.L flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. Make : Everest or equivalent approved by GE
Anodized aluminum snap grid frame work for false ceiling, including supporting hangers for securing frame work to ceiling & to snap grid etc complete all as specified and directed.
Re-Fixing of anodized aluminum snap grid frame work for false ceiling, incl supporting hangers for securing frame work to ceiling & to snap grid all as per specified and directed.
Gypsum board 12 mm thick for insulation and accoustic purposes, 60 cm x 60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
Re-Fixing of gypsum board 12mm thick in ceiling fixed with screws as per manufactures instruction & including two coats of OBD over chalk whitening etc completedall as specified and directed.
Demolition of brick work or Block masonary built in cement mortar etc complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exc 6 cm mean radius in cement mortor 1:6 etc complete all as specified and directed.
Precast cement concrete solid block masonry using solid block of grade C-5 (1:5:8) exc 10cm in width, built in CM 1:6 complete all as specified and direted.
Taking down cement or cement lime plaster on brick/stone walls etc. including racking out joints hacking for key scrubbing down with water etc etc complete all as specified and directed.
15 mm thick rendering in CM 1:4 on external surfaces of brick surface/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
15 mm thick rendering in CM 1:6 on internal surfaces of brick surface/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coat of cement base paint complete ll as specified and directed.
Preparation of new plastered surfacess of walls and applying two coat of colour wash over one coat of white wash complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed..
Preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed
Preparation of new plastered surface of walls and applying two coats of distemper oil emulsion over a coat of chalk whiting complete all as specified and directed.
Preparation new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Preparation of new ceiling surfaces and applying two coats of distemper oil emulsion over a coat of chalk whiting complete all as specified and directed.
Preparation of old plastered surface of walls and applying two coats of distemper oil emulsion over a coat of chalk whiting complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying two coats of cement base paint completed all as specified and directed.
Dismantling of stone slabs of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc.. Complete all as specified and directed.
Machine cut cudappah stone slab 20-25 mm thick laid over and including 20 mm thick cement screed base in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling of stone slabs and tiles of any description of thickness in floors, aprons etc laid, bedded and pointed in any mortor etc completed all as specified and directed.
Demolition of unreinforced cement Concrete of any description and any position not otherwise specifically provided for etc completed all as specified and directed.
Hardcore of gauge exc 63mm but n exc 100 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
Moorum filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
100 mm thick PCC 1:4:8, type D2 using 40 mm graded aggregate as in sub base of flooring complete all as specified and directed.
100 mm thick PCC 1:2:4, type B2 using 40 mm graded aggregate as in sub base of flooring finishing surface even and smooth without using extra cement complete all as specified and diercted.
75 mm thick PCC 1:4:8, type D-2 using 40 mm graded aggregate as in base/sub base of flooring etc complete all as specified and as directed.
Precast cement concrete interlocking tiles (glossy finish/ rubber mat finish) of 60 mm thick ,hydraulically pressed cemented tiles of grey colour with pigments,(glossy finish/ rubber mat finish) factory made, M-35 grade conforming to IS-15658-2006, as in floor laid over & including 25 mm thick sand cusion and including filling of interstices with fine sand complete all as specified and as directed by Engineer-in-charge. Note Size, shape & pattern of tiles shall be as decided.
Granite of any type work (table rubbed and polished) in steps,jambs,pillars,window cill,cooking platform and like set in 15 mm thick CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite complete all as specified and directed.
Machine in cut kota stone flooring 20-25 mm thick (size of kota stone slab 22"x22") laid over and including 20 mm thick bedding layer CM 1:6 with pigments to match the shade of slab including cutting, rubbing and mirror/ granite finish polishing including to remove dust complete all as specified and directed.
All as per ser item no. 12 here-in-before but 18 to 20 mm thick kota stone on vertical surfaces such as in skiting /dado of size as required at site including10 mm thick backing coat of plaster in cm (1:4) complete all as directed.
Dismanlting floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviciable tiles to store and rubbish off the premises all as spd and directed.
Vitrified Ceramic tiles (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick bedding layer in CM 1:4 complete all as specified and as directed.
Glazed ceramic tiles (plain or printed) of each tile of size exceeding 0.11 Sqm but not exceeding 0.18 sqm, 7 mm thick as on vertical surfaces like dado, skirting etc jointed in neat cement slurry and pointed in coloured cement laid over and including 10 mm cement plaster backing in CM 1:4 complete all as specified and directed.
Taking down chowkhats or frames with shutters(without taking off shutters from the frames) not exc 1.50 sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed.
Taking down chowkhats or frames with shutters(without taking off shutters from the frames) exc 1.50 sqm & n.exc 4.00 sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed.
2nd class hard wood (sal/ Hollock) as in plain solid, straight chowkats & frames, wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc complete all as specified and directed.
30 mm thick 2nd class soft wood 30mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc, (with out sash bars) edges of framing plain, chamfered or rounded, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars fitted with cut and mirtred beads for securing glass, wire gauge etc, sizes of members of shutters as specified in SSR part I Section 8, Clause 8.24 (a) supplied and fitted to chowkats for windows, ventilators etc complete all as specified and directed.
35 mm thick second class hardwood, factory made , plain framed,panelled shutter with panel of 9 mm thick BWP plywood bonded with high quality phenol formal dehyde synthetic resin adhesive confirming toIS-710. the size of rails & style shall be as per IS -1003 (Part I) kiln seasoned as per IS -1141 & chemically pressure treated as per IS-401 complete all as specified & directed
Preparation of new wooden or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
150 mm long (ISI marked), mild steel barrel tower bolt of stove enameled black with bright bolt & fixed, complete all as specified and directed.
100 mm long (ISI marked), mild steel barrel tower bolt of stove enameled black with bright bolt & fixed, complete all as specified and directed.
300 mm long mild steel Slinding door plated type, stove enameled black with bright bolt not less than 12mm dia with and incl a minimum of 6 bolt and nuts, four bolts on plate and two on staple plate and fixed complete all as specified and directed.
100 mm long (ISI marked), butt hinges, medium weight cold rolled, mild steel, fixed complete all as specified and directed.
75 mm long (ISI marked), butt hinges, medium weight cold rolled, mild steel, fixed complete all as specified and directed.
75 mm long (ISI marked), mild steel pressed handles, oval type stove enameled black, fixed complete all as specified and directed.
100 mm long (ISI marked), mild steel pressed handles, oval type stove enameled black, fixed complete all as specified and directed.
Steel window with side hung shutters glazed or gauzed including projecting type hinges including 10 mm round guard bars,steel handles & peg stay & hold fast etc complete with glazing bars dovetailed or welded etc completed all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads etc complete all as specified and directed.
3 mm thick sheet glass ordinary quality & glazing with oil putty/ wooden beads in square not exc 0.50 Sqm each pane fixed to wooden or steel frames etc complete all as specified and directed.
Excavation over areas not exc 1.5 m deep and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenhes n.exc 1.5m wide and n.exc 1.50m in depth for fondations etc, nexc 10 Sqm on plan and getting out in soft/loose soil all as specified and directed.
Returning, filling in soil including spreading, levelling watering and well ramming in layers not exc 25 cm as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Excavation in post holes or similar holes, each not exveeding 0.5 Cu.M, getting out inn Soft/Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and diercted.
Plain cement concrete,1:4:8, type D2 using 40 mm graded granite stone aggregate as in foundations, filling and mass concrete complete all as specified and diercted.
Mild steel TMT bars 10mm dia & over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and diercted.
All as per serial item no. 70 her-in-before but TMT bars 6 to 8 mm dia
Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and diercted.
Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and diercted.
Labour only for Cutting holes into or through cement concrete exc 100 Sqm cm nexc 250 Sqm cm in slabs,chajjas, etc.reinforced or otherwise reinforcement is cut through complete all as specified and diercted.
Reinforced cement concrete (nominal mix) 1:2:4, type B0 using 12.5 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and diercted.
Reinforced cement concrete (nominal mix) 1:2:4, type B0 using 12.5 mm graded stone aggregate as in chajjas complete all as specified and diercted.
Reinforced cement concrete (nominal mix) , 1:2:4, type B0 using 12.5 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and diercted.
Formwork to faces of walls, retaining walls, baffle walls etc including attached pillasters, buttresses, etc vertical or to better fair finished surfaces of concrete flat complete all as specified and diercted.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) fair finished surfaces of concrete complete all as specified and diercted.
Taiking down carefully existing bituminous felt including plastered lime or cement concrete of any thickness and cleaning of the surface of roof treanches including flushing and junction parapets kerb walls PCC fillets beanching etc with wirre brushes and removing of the rubbish to a distance not exc 500 mtrs and depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified.
Cutting out cracks to V section in existing roof or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) by weight complete all as specified and directed..
25 mm thick cement concrete 1:2:4, type B-0 using 12.5 mm graded aggregate by using WPC @ 3%. (WPC will be paid seperately) laid even and smooth complete all as specified and directed.
Preparation of roof surface and applying a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/sqm complete all as specified and directed.
APP polythene membrane minimum weight 3kg/sqm and minimum 3 mm thick reinforced with polyster non wooven fabric including aluminium foil on top weighing not less than 150 gms/sqm laid on primed surfaces by forced application including bituminious primer @ 0.30 Litr/Sqm complete all as specified and directed.
Applying of two coats of aluminium paint over APP membrane laid over roof complete all as specified and directed.
Bitumenous gola with industrial bitumen 85/25 mixed with sand in ratio of 1:3 by weight, 8 cm x 8 cm at the junction of roof to verticle surfaces complete all as specified and diercted.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets etc and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc complete all as specified and diercted.
Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards or wooden boards with sunmica top for mounting switches, sockets, fan regulators, accessories etc for one light/fan point controlled by one, one way switch complete all as specified and directed.
All as per serial item no.88 here-in-before but for One 5 Amp 5 pin socket outlet point on the same board including earth wire complete all as specified and directed.
All as per serial item no.88 here-in-before but for One 5 Amp 5 pin socket outlet point on independent including earth wire complete all as specified and directed.
All as per serial item no.88 here-in-before but for one bell point controlled by on bell push including earth wire complete all as specified and directed.
All as per ser item No. 88 here-in-before but point wiring with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire & connected to commen earth & earth terminals including PVC/wooden folding boards for mounting purposes complete all as specified and directed.
Switch piano flush button single pole one way 5 amps,230 volts, fixed complete all as specified and directed.
Switch piano flush button single pole one way 15 amps, 230 volts fixed, complete all as specified and directed.
Socket outlet 3 pin, 5 Amp multipurpose flush type, fixed complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5 & 15 Amp flush type, fixed complete all as specified and directed.
Bell push piano flush type one way ISI marked, fixed complete all as specified and directed.
Bell AC, 230 Volts Single Phase ding dong, multi music type complete all specified and directed Make : Plaza/Finolex/Anchor
Ceiling rose surface bakelite 65 x 50 mm, 2 to 3 terminals, polycarbonate / PVC / isolated body, fixed complete all as specified and directed.
Lamp holder angular type PVC/polycarbonate type with 10 W LED lamp complete all as specified and directed.
High efficiency LED 20 W aluminium linear batten type complete with all accessories internally pre-wired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size, fixed in replacement complete all as specified and directed. Make: Havells, Bajaj, Philips
MCB/Isolator TPN 63 Amps 415 Volts, fixed in position complete all as specified and directed. Make Legrand/Havells/Schneider
MCB DP 40 Amps 220 Volts, fixed in position complete all as specified and directed. Make Legrand/Havells/Schneider
Sheet metal enclosure (DB) double door single pole and neutral 8 way, 240 Volt with 200 Amps rated bus bar complete all as specified and directed..Make :Legrand,(DX3)/SCHNEIDER-(ACTI 9) / Siemens-Betagard(10KA)
Sheet metal enclosure (DB) double door single pole and neutral 12 way, 240 Volt with 200 Amps rated bus bar complete all as specified and directed..Make :Legrand,(DX3)/SCHNEIDER-(ACTI 9) / Siemens-Betagard(10KA)
MCB SP 6-32 Amps, fixed in position complete all as specified and directed. Make Legrand/Havells/Schneider
Ceiling fan 1200 mm sweep complete with all accessories clamp, down rod , canopy and making connection with and including 1.5 sqmm copper conductor cable complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) including dismantaling of existing unserviceable earth pit all as specified and directed.
Stepped type electronic fan regulator flush type humming free as required complete all as specified and directed.Make:Plaza/Fine/Anchor
Sub main wiring with two single core of 2.5 Sqmm and one single core of 2.5 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through casing/caping of size 32/25 mm including accessories as in repairs complete including making good the disturbed surface to match the existing surface complete all as specified and directed. Make: Plaza/Havells/Polycab.
Sub main wiring with two single core of 4 Sqmm and one single core of 4 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through casing/caping of size 32/25 mm including accessories as in repairs complete including making good the disturbed surface to match the existing surface complete all as specified and directed. Make: Plaza/Havells/Polycab.
Exhaust fan 300 mm sweep single phase 220 V metalic body, copper wound, heavy duty with louvers, fixed complete including making hole in stone/brick wall masonary suitable for mounting 300 mm sweep exhaust fan and making good the disturbed surface and complete finishing using 1:6 cement mortar and removing all debries from site and making connections from ceiling rose to fan with and including 1.5 sqmm copper conductor cable complete all as specified and directed. Make : Crompton Greaves/Bajaj /Khaitan
PLUTO NEO PANEL ultra modern recessed monting luminaire suitable for ceiling in MS housing with high brightness LEDs fixture size 595 mm x 595 mm x 70 mm including making connections with and including suitable size copper conductor cable and fixed complete all as specified and directed. Make:Havells CatPart No PLUTONEO2x2PLR42WLED857S or Equivalent in make CG/ Wipro/Philips
High power LED bldg security light fittings 30W including service bucket and clamps including making connections with and including suitable size copper conductor cable and fixed complete all as specified and directed. Make: Havells/Crompton/Philips
MCCB, 4 pole, 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA including wooden board of suitable size for fixing of MCCB and proper connection complete all as directed and specified and directed. Make : ABB, Havells, L & T
Change over switch 160 amps current carrying capacity 415V 3 phase and neutral enclosed type with front operating latch handle and locking arrangement, fixed in replacement complete all as specified and directed Make - Bajaj / phillips/Havells or equivalent approved.
Single pole and neutral enclosure with a two pin socket complete with one single pole MCB 32 Amp complete all as specified and directed. Make :Legrand,(DX3)/SCHNEIDER-(ACTI 9)/Siemens-Betagard(10KA)
M/s S.R lahoti
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .