Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC LOWEST QUOTED | |
| 2 | L2₹12.0 L+₹4,640 (0.39%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L2 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 3 | L3₹12.9 L+₹89,260 (7.45%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 4 | L4₹13.0 L+₹98,510 (8.22%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 5 | L5₹14.4 L+₹2.5 L (20.5%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
4 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
GE AF UDHAMPUR
REPAIR AND MAINT OF PERIMETER LIGHTS, TIMERS, LT OUTDOOR PANEL AND ITS CONNECTED ITEMS AT VARIOUS LOCATIONS AT AF STN NATHATOP
2021_MES_433217_1
GEAFU-61/2020-21
Open Tender
Miscellaneous Works
Item Rate
270 days
AF STATION NATHATOP
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹36,000
Yes
22 May 2021
26 Mar 2021
6 May 2021
26 Mar 2021
4 May 2021
20 Apr 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceavle cable and Supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor rating 1100 volts grade of size 95 sqmm, 3.5 core, laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified Note: Neceesary Earth work, brick protection and sand cushioning shall be measured and paid for separately.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
Taking down of any size street light fittings ,and M&L for LED light energy saving and environmental friendly long life versatile pressure dia cast aluminium and toughened glass fitted in frame with IP-66 protection road way light fitting with high power LED as light source of capacity 60 watts with suitable driver and all standard accessories etc complete all as specified and as directed. Make :- CAT PART NO:ENDURAPEARLNEOSL60WLED757PASYTOPC of Havells or equivalent to Wipro /Philips/Crompton Notes : (i) Contractor has to produce LM-79/LM-80 certificate along with purchase vouchers (ii) Surge protection of the drive should be 5 KV.
Taking down of any size street light fittings ,and M&L for LED light energy saving and environmental friendly long life versatile pressure dia cast aluminium and toughened glass fitted in frame with IP-66 protection road way light fitting with high power LED as light source of capacity 90 watts with suitable driver and all standard accessories etc complete all as specified and as directed. Make :- CAT PART NO:ENDURAPEARLUSSL90WLED757PASYTOPCASTHO of Havells or equivalent to Wipro /Philips/Crompton Notes : (i) Contractor has to produce LM-79/LM-80 certificate along with purchase vouchers (ii) Surge protection of the drive should be 5 KV.
Taking down of any size street light fittings ,and M&L for LED light energy saving and environmental friendly long life versatile pressure dia cast aluminium and toughened glass fitted in frame with IP-66 protection road way light fitting with high power LED as light source of capacity 120 watts with suitable driver and all standard accessories etc complete all as specified and as directed. Make :- CAT PART NO:ENDURAPEARLMAGSL120WLED757PASYTOTGASTHO of Havells or equivalent to Wipro /Philips/Crompton Notes : (i) Contractor has to produce LM-79/LM-80 certificate along with purchase vouchers (ii) Surge protection of the drive should be 5 KV.
Taking down of any size street light fittings ,and M&L for LED light energy saving and environmental friendly long life versatile pressure dia cast aluminium and toughened glass fitted in frame with IP-66 protection road way light fitting with high power LED as light source of capacity 150 watts with suitable driver and all standard accessories etc complete all as specified and as directed. Make :- CAT PART NO:ENDURAPEARLMAGPLUSSL150WLED757PASYTOTG of Havells or equivalent to Wipro /Philips/Crompton Notes : (i) Contractor has to produce LM-79/LM-80 certificate along with purchase vouchers (ii) Surge protection of the drive should be 5 KV.
M&L for LED street light driver 60 watt to 90 watt with universal voltage 90-300 volts alternating current ,short circuit,over temperature and over load protection complete including taking down old.
M&L for LED street light driver 120 watt to 150 watt with universal voltage 90-300 volts alternating current ,short circuit,over temperature and over load protection complete including taking down old.
Taking down old unserviceable bracket and supply and fixing new Street light bracket for fixing of street light fittings, bend to shape, made out of 40 mm dia GI pipe medium grade not less than 1.5 mtr long fixed with and including clamps made from Flat iron of size 50 x 6mm, bolts, nuts & washers & two coats of aluminium paint over a coat of red oxide primer complete all as directed.
Taking down old unserviceable cable and Supply, laying and passing through pipes/poles cable weather proof flat copper conductor twin core of size 2.5 sqmm for connection from junction box to pole with flexible conduit of appropriate size ( if required at site) all as specified and directed by Engr-in-Charge.
Taking out old rusted unserviceable GI tubing of any size and M&L new GI tubing 40mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified.
Taking out old rusted unserviceable GI tubing of any size and M&L new GI tubing 50 mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified.
Supply and fixing MCB Disribution board 1 row 3 modules of polycarbonate themoplastic, IP 65 dust proof, jet water tight corrosion proof, halogen & silicon free, with high quality earth and neutral links, internally embedded gasket for led and enclosures made PUR with cable glands and other accessories with MCB 6 amps and required terminals, metric size knock transparent door & with cable enerty covered and suitable to accommodate any make of MCCB and tested as per IEC 60439-3 (Flame retardant self extinguishing of size 202x238x111 mm complete all as specified and directed including taking down old. Make : Hensel cat Ref Nom: KV 7103/legrand/Schneider
M&L for energy saving ,enviromental friendly,long life,exclusive innovative die-cast aluminium IP66 flood light of capacity 300 watt with high power LEDs as light source,suitable for highlighting architectural façade highmast and general purpose lighting including electrical connection, including taking down old unserviceable, complete all as specified and directed by engineer-in charge .Make : CAT PART NO:JETAVALOURFL300WLED757MODNBLTG of Havells or equivalent to Wipro/ Philips/ Crompton
M&L for energy saving ,enviromental friendly,long life,exclusive innovative die-cast aluminium IP66 flood light of capacity 150 watt with high power LEDs as light source,suitable for highlighting architectural façade highmast and general purpose lighting including electrical connection, including taking down old unserviceable, complete all as specified and directed by engineer-in charge .Make : CAT PART NO:JETAIRISFLS150WLED757PSYMLTG of Havells or equivalent to Wipro/ Philips/ Crompton
Taking down old unserviceable junction box and Supply, installing, testing & commissioning of street light Pole Box of 63 Amps, Three Phase four wire having four number aluminium bus bars including 6 Amps TP MCB. The box should have auto door lock facility with magnetic lock/manual having size 300 x 160 x 250 mm complete all as specified and directed. Make :- DVEPL Cat Part No. NO.SLPBTP63 or equivalent in Hensel./Legrand
Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15 mm buried directly in ground vertically at a depth not less than 4.50 metre below normal ground level with top edge of earth plate at a depth not less than 3.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed alternate layer of common salt and charcoal and a top layer of copper sulphate 150mm thick all as specified and as directed in drawing No CEAF/SK-60/2017 Dt 24.4.17 including bringing of mother soil from outside for filling holes, including Copper strip of size 20 x 3mm by means of nuts, bolts and check nuts, washers of copper up to main board/test point or as required including necessary excavation and earth work in any type of soil so as to achieve earth resistance below 3 Ohms including excavation of polypit chamber with polyplastic pit cover (cost of polypit chamber with polyplastic pit cover shall be deemed to be included in the rate quoted) complete all as specified and as directed by Engineer-in-Charge including dismantling of existing unserviceable earthing. Notes : (a) Copper strip beyond test point shall be measured and paid for separately. (b) Earthing resistance result shall be less than 3 Ω .If the result comes more than 3 Ω the contractor shall carry out the earthing at separate location/site given by the Engr-in-Charge after taking out of earth electrode without any extra cost to the deptt. (c) Test point terminal block shall be measured and paid for separately. (d) The contractor's quoted rates shall be deemed to include for dismantling/taking down of old unserviceable earthing of any type and making good the disturbed surfaces and nothing extra shall be admissible on this account. (e) Any other fittings/fixtures if technically required for achieving desired results (if not included above) shall be provided by the contractor without any extra cost to the Govt. (f) If mother soil is not available then mother soil wil be provided by contractor from outside source without any extra cost to the Govt.
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
Earth continuity conductor or main earthing lead 20x3 mm Copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, In Repair,complete all as specified & directed by Engr-in-charge
S&F in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long,on roof top of building of height 06 meter to 30 Meters,complete all as specified and directed by Engr-in-charge.
Marking the earthing pit with white / coloured hylam sheet/ perplex sheet 3mm thick of size 200x 150mm fixed with MS angle iron 20x20x4mm and 0.75 m long including painting with synthetic enamelled paint two coats over a coat of red oxide primer fixed by means of 2 nos nuts/ bolts/ washers of with colour code as per direction by Engr-in-charge, suitable size and grouting the marker nearer to the earth pit in PCC type B-1, 1:2:4 of size 0.15x0.15x0.15m including necessary earth work, marker shall be having the following letters (letters of size 25mm) complete all as specified and directed by Engineer-in-Charge: EARTH PIT NO_________________________ CHEMICAL/ COPPER/ GI_________________ EQUIPMENT/ BUILDING CONNECTED________________________ DATE OF TEST :____________________________ EARTH RESISTANCE_______________________
S&F in replacement of Lightning arresters expulsion type complete with all fittings, treansmission class, discharge capacity 65 kilo amp for 11000 Vollts complete all as specified and directed.
S&F PVC Exhaust fan of size 450 mm sweep ,240 V including grouting in wall with hold fastner ,wooden frame as required at site,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.MAKE:HAVELLS/BAJAJ/CROMPTON
Labour only for cleaning throughly from inside of fuel tanks of capacity 10000 Ltrs and after cleaning painting of tanks with 02 coats of red oxide from outside and writing tank No ,complete all as specified and directed.
M & L in respect of porcelain insulators for fixing aluminium/copper strip with nut bolt & washers to wall/surface with brazing complete all as specified & directed.
S&F in replacement of draining out the old used engine oil / transformer Oil cleaning and refilling with new engine oil 15 W 40 CF4 Grade upto the required level complete all as specified. Make : Constrol/Valvo Line or equivalent as approved by GE.
M&L for painting of SM/MES No. on plant and machinaries from outside as per E-in-Cs policy held in charge of MES complete all as specified and directed.
S&F in replacement of numerical transformer diffrential relay of frequenct +- 0.02 HZ with current rating 1/5 amp, 8 poles complete all as specified and directed.
S&F in replacement of silica gel breather of transformer for filtring air from moisutre complete all as specified and directed.
S&F in replacement of 11 KV HT energy meter secure premier 250 type with frequency 50 HZ digital display for showing MWH, MWArh, MW, MVA etc with temprature sensor complete all as specified and directed. Make : HPL/Secure meters Ltd or equivalent approved by GE
M/S M P Construction Co
RANBIR ENTERPRISES
DAVINDER SINGH
R K BUILDERS
slathia construction works
kerni electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .