Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | ₹1.0 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.1 Cr+₹3.4 L (3.30%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | ₹1.1 Cr+₹3.4 L (3.30%) | L2 | Rejected-Finance Quoted higher rate |
| 3 | L3₹1.1 Cr+₹9.1 L (8.87%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | ₹1.1 Cr+₹9.1 L (8.87%) | L3 | Rejected-Finance Quoted highest rate |
| 4 | Rejected-Technical 11E SANTOSH ROY ROAD KOLKATA 700 008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | - | - | Rejected-Technical Original file of eNIT not submitted with valid DSC (as per Clause A-1(i), Page-7 of NIT). 2 no. diff. Trade License, diff. GST Certificate and diff. PAN Uploaded. Valid Credential, mentioning the Date of completion and Final bill value, not found |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
28 Sept 2024, 6:00 pmClosed
SE,KHEC,PWD
Kolkata Health Electrical Circle, P.W.Dte KIT Annex Building, 5th Floor KOLKATA
Setting up of central Panic Alarm system incl. EI work at diff. bldgs. in the campus of SSKM Hospital, BIN, separate Panic Alarm system of SNPH, P.G. Polyclinic, KPH, Khidirpur Maternity Home and Ramrikdas Haralalka Hospital, Kol. (Rattirer Sathi)
2024_WBPWD_756953_1
WBPWD/SEKHEC/KSHED/eNIT15/ 24-25
Open Tender
MISC ELECTRICAL WORKS
Item Rate
30 days
SSKM Hospital
Please refer Tender documents.
7 documents required · 7 mandatory
₹2.1 L
Office of the SE,KHEC,PWD
5 Dec 2024
25 Sept 2024
30 Sept 2024
25 Sept 2024
28 Sept 2024
25 Sept 2024
25 Sept 2024
Amount
SITC of Microprocessor based Intelligent addressable Security alarm control panel ( EN54/VDS approved ) fully networkable having requisite numbers of loop with 20% spare capacity with each loop capable of taking requisite number of devices as per latest IS/NBC, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all call/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. IS / NBC. Shiuld have the provision for incorporating with BMS.
The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards (no field loop card is allowed), L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required.
The Panel shall be capable of being networked ( future expansion ) with other similar Panel located at different part of the premises through single RS 485 bus.The Panel shall have provision for interfacing with BMS( RS 485 ). The panel should have modbus output & ready to communicate with remote computer. The system must be preloaded with licenced software. (Approved Make: BOSCH, Model No. AVENAR 2000 or equivalent of Siemens /Godrej / Honeywell /Carrier ].
Single Loop Security Alarm Panel
Two Loop Security Alarm Panel
SITC of Microprocessor based Intelligent addressable Security alarm Repeater Panel (EN54/VDS approved) which will act as an add-on device for remote display of SACP status information of the Panic Detection Alarm operating front related to the detectors and decetors zones.Event messages are displayed via LED collective indicators and on the 2-Line LCD display with the associated detecors zone number and a programmable additional text. Each message is signalled via the built-in buzzer. The buzzer can be acknowledged by pressing a button. The requisite LCD indicator panel can be operated on as RS 485 bus. [ Approved Make: BOSCH, Model No. FPE-8000-FMR or equivalent of Siemens /Godrej / Honeywell /Carrier ].
SITC of Addressable Manual Call Point ( EN54/VDS approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. [ Approved Make: BOSCH, Model No. FMC-210-DM-G-R or equivalent of Siemens /Godrej / Honeywell /Carrier ].
Supply & Installatin of Key for Manual Call Point [ Make :- BOSCH, Model No. FMM-KEY-FORM G/H or equivalent of Siemens /Godrej / Honeywell /Carrier ].
SITC of Addressable Loop Powered Hooter Base complete with inbuilt isolator & IP65 base and ( EN54/VDS approvedd). [Approved Make: BOSCH, Model No. FMC-420-A-BS-RD or equivalent of Siemens /Godrej / Honeywell /Carrier ].
SITC of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete all accessories ( EN54/VDS approvedd). [ Approved Make: BOSCH, Model No. FNS-420-R or equivalent of Siemens /Godrej / Honeywell /Carrier ].
Supply, Installation, Testing & Commissioning of Addressable transponder cum Monitor Modules 1 input and 1 output for monitoring flow switches/Fire exit doors etc complete as required. [Approved Make: BOSCH, Model No. FLM-420-O1/1-E or equivalent of Siemens /Godrej / Honeywell /Carrier ].
Supply, Installation, Testing & Commissioning of Addressable Relay interface module with inbuilt low-volt input etc complete as required. [ Approved Make: BOSCH, Model No. FLM-420-RLV1-E or equivalent of Siemens /Godrej / Honeywell /Carrier ].
PART B: Ethernet Backbone & allied works
SITC of Layer 2, POE++ enabled, fully managed,1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with one year software renewable license of OEM, having minimum technical specification: a) 8X10/100/1000 Mbps POE++ enabled host ports (Minimum). b) 2X1GE SFP port including modular and field replaceable SFP module of same rating. c) Fanless operation with operating temperature up to 45°C. d) 512 MB DRAM and 256MB Flash RAM (Minimum). e) Software support with IPv4 routing (542 routes), multicast routing (IGMP) including necessary software license. f) Minimum switching capacity of 20Gbps. g) Number of VLAN Supported: 64 (Minimum). h) Total number of MAC Adress:8,000 (Minimum). i) Minimum Security features e.g.Dynamic Host Configuration Protocol (DHCP) Snooping, Dynamic ARP Inspection, Instrusion Detection System, IGMP FILTERING, Multi-domain authentication, Access control lists (ACLS) for IPv6 and IPv4 security and Quality-of-Service (QoS) ACL elements, SNMP, MAC address notification, Spanning-Tree Root Guard (STRG), IGMP filtering etc. ( Make: Cisco / Extreme /Juniper).
Supply, Installation, Testing & Commissioning of Rack mount Sliding LIU 24 PORT 1U, UNLOADED with Splice Tray and Cable spool. LIU should accommodate up to 48 connections in only 1U (1.75”), Suitable for both 19” frames, Security fastened patch cords can exit to left or right, Metal Box and Splice tray must have Aluminium powder coated. Must have Fire retardant plastic for LIU. It should be RoHS Compliant (LIU ) as per Technical specification. (Make: Tyco/ Molex/ Belden /CISCO)
SITC of 10/100/1000Base- T to 1000Base - X Fiber Media Converters - Managed that Connect 10/100 devices to Gigabit backbone, ST,SC and LC fiber connector options, Multimode and Single mode fibre SX,LX,LH,EX,ZX,BX fiber support, Advanced features: Smart Link Pass- Through, Fiber Fault Alert, Auto-MDIX and Loopback. Make: D- Link / MROTEK / Degesol/TPLINK/CISCO)
Supply, Delivery & Installation of Pigtail, Patch Cord, Adaptor and Accessories (As required for Load both the LIU) .[ Make: Tyco/ Molex/ Belden/ CISCO)
SITC online IGBT based double conversion Rack Mountable UPS with SMF battery, Rack and link for 30 minutes backup (Capacity 2 KVA) [ Make; Emersion / APC/Numeric, Battery Amaron/ Exide ].
Supply & Installation of of CAT 6F/UTP 24 Port Modular fully loaded patch Panel TIA/E1A-568-C.2:2009 EN 50173-1:2011Class E, ISO/IEC 11801:2010 (Ed 2.2) Class E, FCC Subpart F68.5 UL Listed.l [Make D-Link /TPLINK/CISCO)
Supply & Installtion of 9U Wall Mount Network Rack having Front GlassDoor with Lock, 2 pairs of 19" Mounting Rails complete with Cable Manager,Roof Mounted Fan Unit / 90 CFM /230V AC,6 Way 5 Amp Power Distribution Unit, Mounting Hardware and all other accessories. [Make: D-Link/ Valrack/TPLINK/CISCO)
Supply & Laying of 12C Armoured Multimode Fiber Optics Cable including all necessary accessories like connector, joiner ,splitter, repeater etc. through existing 32 mm dia HDPE pipe (Sch-40) colour-GREEN through existing U.G. Trench/ Permanent Cable trench as per requirement of site (For Panel to Panel Network) [ Make : Cosmcope].
Supply & Laying of Solid Cable Cat 6, 4 pair, UTP ( 305 Mts) through in existing prelaid 20mm dia PVC rigid conduit (medium), must have Fire retardant PVC Compound (FRPVC) Flame Rating material, All cables meet and exceed Category 6/Class E requirements in ANSI/TIA-568-C.2, and ISO/IEC 11801. Must be RoHS Compliant as per Technical specification. (For Panel to Panel Network) [ Make : Cosmcope/ Finolex / MOLEX ].
Supply and laying 40 mm dia HDPE pipe (Sch-40) colour-GREEN including socket, jointing kits etc through existing U.G. Trench/ Permanent Cable trench after opening the existing concrete slabe and as per requirement of site. and mending good damages to original finish as per direction of EIC [ Make - Finolex/Supreme/ Oriplast]
Supply and laying 20mm dia. FR grade PVC Rigid Conduit Pipe (Precision/ Polycab) on surface of wall, ceiling wilth all accessories e.g. PVC Saddle, Elbow, Tee, Circular Box, Screw, etc. and mending good damages to original finish as per direction of EIC
Supply & Laying of 2 Core 1.5 sq.mm Armoured FRLS shielded copper Cable (For Loop) (Make. MEM) in prelaid 20mm NB PVC rigid conduit pipe including necessary terminations at all required as direction of EIC. ( outside of the building) [ Make: Polycab/Havells/ Finolex/Gloster ].
Supply & Laying of 2 Core 1.5 sq.mm un-armoured FRLS shielded copper Cable (For Loop) (Make. MEM) in prelaid 20mm NB PVC rigid conduit pipe including necessary terminations at all required as direction of EIC. ( Inside of the building) [ Make: Polycab/havells/ Finolex)
SITC of 32" (80 cm.) Full HD LED TV for display having in-built WLAN and minimum 2 x HDMI, 2 x USB Port including Full Function Remote, Power Cord, Wall mounting Kit,LAN modem etc incl all accessories.(AS per direction of EIC)(Make-Samsung, Model LS32CM501EWXXL/ Sony, Model KD32W820K/Panasonic)
Commissioning entire system by Integrating the system with existing Ethernet Network, configuring and programming of all programmable devices as per requirement of the Hospital authority, Testing all active & passive components including on-site training for operation of the system to three authorised persons as per direction of Engineer-in-charge
TERMS & CONDITIONS
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 1 (One) Year
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
GHANASHYAM ELECTRIC STORES (BID ID -5650968)
CHAKRABORTY ENTERPRISE (BID ID -5647836)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .