GE ARMY SURATGARH
SURATGARH MIL STN
Provn of stone pitched hardstanding and other sanctioned works under AGE B/R-II at Suratgarh Mil Stn
2021_MES_426311_2
GE (A) SOG - 75/20-21
Open Tender
Civil Works
Item Rate
180 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹46,000
Yes
17 May 2021
9 Apr 2021
1 May 2021
9 Apr 2021
29 Apr 2021
15 Apr 2021
60 days
Amount
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
Demolition of plain cement concrete in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified and directed by Engineer-in-charge.
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc including ridges complete all as specified and directed by Engineer-in-charge.
Dismaintling of wall and ceiling board or insulation boards/slabs/blankets, any thickness including cover fillets complete all as directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Taking down steel window / ventilator of any description and of any type with or without guard bars and making good the disturbed portion complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts and making good disturbed surface with cement mortor or PCC after fixing new chowkats complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, fixing lugs etc complete with glazing bars including one shop coat of red oxide primer and Cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified & directed by Engineer-in- charge
M&L for 30mm thick flush shutter solid core construction with block board core & ply wood face panels, commercial type on both faces complete all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) in floors complete all as specified and directed and directed by Engineer-in-Charge. Note: - Reinforcement shall be measured and paid for separately.
M&L for form work to faces of walls, retaining walls, abutments, parapets, and staircase railings and similar work, including attacheded pillasters etc.; for fair finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 (design mix), using 20mm graded stone aggregate as in walls, retaining walls, ballast walls and the likes; any thickness; above top of footings, including attached pilasters and buttresses complete all as specified and directed by Engineer-in-Charge. Note: - Reinforcement and form work shall be measured and paid for separately.
M&L walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:4 all as specified and as directed.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for keyed pointing in cement mortar (1:3) to brick walls complete all as specified and directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
S&F rolled mild steel as in Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length directed) and similar work conforming to Gde E-250 (Fe 410-W) quality `A’ all as specified and as directed.
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-charge.
S&F 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long extruded aluminium alloy handles, anodised, fabricated type complete all as specified and directed by Engineer-in-Charge
M&L for continuous brick edging (sub class ‘B’) with width equal to the depth of brick laid dry on end vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified. Note : Each row shall be measured and paid separately.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
All as per serial item No 26 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S & F 0.63mm thick galvanised, plain mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zink coating 275 complete all as specified and directed by Engr-in-charge.
M&L 0.63mm thick mild steel, plain, black sheet in hearths; covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 100mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in floor, top surface finished fair & even including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed. Note :- PCC shall be laid in alternate bays in panels of size not exc 2m x 1m and joints shall be filled with bitumen mastic (1:3). Quoted rate shall deemed inclusive for same.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 15mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab 18 to 20mm thick (minimum size 550mm x 100mm or size as directed), on vertical surfaces such as dado, skirting, raiser of steps etc. laid over & including rendering 10mm thick in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 350mm x 250mm x 7mm or 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in two layer on fair faces of brick masonry or concrete surfaces of walls consisting of 1st layer of 10mm thick plaster in CM 1:6 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4 mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished fair & even, complete, all as specified. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing,scrapping down smoke soot mulds, moss and efflorescent, salts etc and applying two coat of cement based paint complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new untreated steel and iron surfaces of any description, not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide, 150mm deep and sides dressed, bedded in cement mortar 1:3, cement mortar 1:2 with an admixture of metallic floor hardener, 5% by weight of cement and struck flush complete all as specified and directed by Engineer-in-Charge.
M&L for edge stone to stone sett flooring with stone setts of size 250 to 300mm long, 150 to 200mm wide and 450mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
S&F in repair Anodised aluminium snap grid frame work of size 605mm x 605mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross Tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM and 23.5mm x 26.4mm x1.40mm weighing 0.191Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminium angle bracket of size 15mm x 15mm x 1.5mm weighing 0.12Kg /RM fixed with suitable MS bolts, nuts and washer. The snap grid (main /cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 35mm x 25mm x 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement duly suspended with 3mm dia GI wire length as required @ 600mm C/C with adjustable device including plugging in brick / concrete work with steel raw plugs including making good all the disturebed portion complete all as specified and directed by Engineer-in-Charge.
M&L for 4mm thick E board classic, fibre base cement boards, embosed texture, fixed to aluminium snap grid (size of grid 605mm x 605mm) in ceiling complete all as specified and directed by Engineer-in-charge. Note :- The aluminium snap grid frame work shall be measured & paid for separately.
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Note : Taking down of serviceable fittings shall be measured and paid separately.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 59 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 59 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per Srl item No. 59 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F in replacement flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 40 Amps, Single Pole & Neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in replacement Energy efficient decorative ultra slim, prewired, aluminium body 20 watt LED light fitting (Day cool light), batten type with drive including polycarbonate diffuser with tube rod inbuilt and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS20WLED865SPCWH / Syska Cat part No SSK-ALB-20W / Crompton cat part No LCTLN-20-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in repair street light bracket made out of 40mm dia GI pipe light grade 1.2m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing in replacement LED Street / Security light fitting of 30 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Syska Cat part No. SSK-SLG-CF-30W / Crompton Cat Part No LSTS-30-CDL-M/ Havells Cat part No ENDURAPEARL SL30WLED757SASYTOPCMP / Wipro Cat Part No LR02-331-XXX-57-XX or equivalent in makes mentioned in Appendix 'A' here-in-after.
Notes for srl Item No 77 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F in replacement heavy duty exhaust fan 450 mm sweep, 1400 RPM, single phase, 230 volts, 50 Hz with IP 55 protection as per IS-2312 1967 with louvers including suitable size MS angle frame for mounting the 380 mm sweep fan and connecting up and including 3 core,1.5 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge. Note :- (i) MES No with stencil shall be marked on exhaust fan body using synthetic enamal paint. Cost of the same is included in the unit rate of this item. (ii) Old unserviceable exhaust fan shall be deposited in AGE E/M store yard by the contractor at his own arrangement. Nothing extra shall be paid.
S&F in replacement energy saving, environment friendly & robust highbay LED 80 watt with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/Watt duly prewired and connecting up with twin core twisted 0.5 sqmm copper conductor flexible wire complete all as specified and directed by Engineer-in-Charge. Make : Syska cat part No SSK-HBG-80W or equivalent in makes mentioned in Appendix 'A' here-in-after.
M&L for 75 mm thick PCC nominal mix (1:1.5:3) type A-1 using 20 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for preparation of steel surface already treated with primer over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge. --------------------------------------------------------------------- Note :- A sum of Rs. 13442/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 23(Schedule of Credit) of Tender documents.
PACHR BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .