Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹26.8 L+₹1.8 L (7.09%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹27.9 L+₹2.9 L (11.6%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹30.0 L+₹5.0 L (20.0%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹31.6 L+₹6.6 L (26.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹29.1 L
EMD Value
₹58,200
Closing Date
29 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Nal, Bikaner
GE (AF) NAL, AF STN NAL BIKANER (RAJ)-334001
AS DESCRIBED IN BILL OF QUANTITIES
2022_MES_548872_1
GE (AF) NAL/T-33/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE (AF) NAL BIKANER
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) NAL
₹58,200
Yes
14 Dec 2022
31 Aug 2022
1 Oct 2022
31 Aug 2022
29 Sept 2022
16 Sept 2022
31 Aug 2022 - 10 Sept 2022
Amount
M&L for dismantling the existing LT overhead line of any size 3 phase 4 wire system (3 phase, neutral and one GI wire) + single phase system for street light and one GI wire including opening of jumpers, insulator, cross arm properly as required complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed.
Dismantling and taking out existing LT PCC Poles complete including foundation and making the disturbed surfaces good complete all as specified and as directed.
Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor Cross sectional area 16 Sqmm, 4 core from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
M& L for LT Panel by Supply, assembly, erection, testing and commissioning of outdoor type floor mounted free standing dust and vermin proof panel/DB with IP-55 protection fabricated out of 40x4 mm sized angle iron and flats and covered with 3.15 mm thick CRCA sheet for outer & 1.6 mm for inner compartment,duly pretreated in seven tank process for de-greasing, de-rusting & Phosphated painted with 2 coats of primer paint then painted with final coat of epoxy based powder coated paint. Panel/DB shall be having front and rear opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. A clear space of 200mm to be kept from floor level for switchgear compartment. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. (Location: - New Projecr Transformer No 1)
Outgoing:- Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. 4P MCCB, 36 KA, 250 A -01 No 4P MCCB, 25 KA, 200 A -01 No 4P MCCB, 16 KA, 125 A-01 Nos 4P MCCB, 16 KA, 100 A-01 Nos 4P MCCB, 16 KA, 63 A-01 Nos 4P MCB TPN, 40 A - 02 Nos Astronomical time switch 110/240 volts Make : Havells or equivalent = 01 Each
Supply , install , testing and commissioning of junction box fabricated out of 3.15 mm thick CRCA sheet steel canopy at the top shall be provided . The junction box to be fix on the ground with PCC platform as per manufacturer recommendation the junction box shall be of totally enclosed cubical type with IP-54 protection . The junction box should have hinged doors and locking arrangement at the rear and front . The junction box should be suitable for three phase 4-wire 415V, 50 cycles AC . The junction box should be treated with rust protection such as degreasing and painted with 2 coat of red oxide primer & standard colour . Knock out gland plates as applicable shall be provided in the junction box for incoming and outgoing cables . Bus Bars : TPN 300 Amp aluminium bus bar E91 grade , 1100 volts grade duly covered with heat shrinkable sleeves colour coded and bus bar insulators as per requirement . Adequate space inside the box shall be provided for bus bar & cable alley to accomodate the incoming and outgoing cables in a proper manner .All power connection shall be secured adequately with proper size of lugs. The Size of junction box shall be such as to accommodate the following : (i) MCCB 200 A, 4 Pole, 16 KA with adjustable electronic release (with release range 300-400A) -01 No (ii) TPN 300 Amp aluminium bus bar E91 grade , 1100 volts of size 30mm x 10 mm with suitable rating connector for cable termination and bus bar insulator as per requirement . (iii) Cable gland of brass for different size of cable as per requirement for incoming and outgoing cable
M&L boring of road crossing of size 80 mm dia at suitable depth not lss than 1 mtr by using machinery / equipments complete without damaging the surface for passing pipes / cables etc including removing excavated soil to a distance n exc 50m complete all as specified and as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.
Supplying and laying as in repairs 50 mm bore GI tubing light grade incl all accessories for passing of cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed.
Taking down DB/ main switch of any size and making good disturbed surface of wall/ floor complete all as specified and directed. Note:- Temporary power supply shall be provided by contractor.
Supply and fixing Vertical TPN DB double door suitable for fixing 100 Amp MCCB, IP 45 protection with powder coated enclosure 4 way insulated busbar assemblyo rating 200 Amps including MCCB 4 pole, 415 V, 100 A, 16 kA - 01 No complete all as specified and directed.
S & F MCB TP, 40 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc.
Supply and fix MCB SPN 40 Amps 10 KA 240 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of lugs etc. complete all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps 10 KA 240 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of lugs etc. complete all as specified and directed.
Excavation in any type of soil in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches for laying of cable / pipes etc.and getting out in hard / dense soil including taking out old bricks complete all as specified and as directed. Note :- (i) Serviceable brickss stacked for reuse.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed.
M&L Removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L sand cushioning using dry and clean tibba sand in two layers, first laylers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ ducts including consolidation of each layers complete all as specified and directed.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertical position , earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level. The earth plate to be connetced with galvanised iron earthing strip of size 32 mm x 6 mm by means of nuts, bolts, chcek nuts and washers made of galvanised iron or steel earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work all as spcified and directed.
RAJENDER ENTERPRISES
M/s Rohit Construction Co.
BIDAWAT ENTERPRISES
m/s gaurav enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .