Loading…
Loading…
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
10 Sept 2026, 6:00 pm
SHRI DARSHAN KUMAR, EE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR/MAINTENANCE OF CEILING FAN, EXHAUST FANS AND GEYSERS AT VAYUSENA NAGAR NAGPUR
2026_MES_785442_1
8848/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF NAGPUR
As per Tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹30,000
20 Aug 2026
20 Aug 2026
12 Sept 2026
20 Aug 2026
10 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down ceiling fan/exhaust fan /air circulating fan/wall fan of any size or of any make from any locations (OTM/Md Accn) under GE (AF) Nagpur by disconnection eletric connection, cleaning the fan box area, bringing to AGE E/M Yard and refixing at the desired location after reassembling and removing of burnt out windings (copper/aluminium), servicing/ overhauling by thouroghly cleaning the shaft ,rotor, stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair/replacement of spare parts/ material/items, making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using minor sparte/parts such as screws, insulation tape, nuts, bolts, washers, split pins etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed.
Notes :-
(i) PVC copper flexible wire 1.50 Sqmm three core, nut bolts, washers, screws, capacitor clamp, warnishing included in the quoted rate.
(ii) Other connected items required like re-winding, painting, capacitors, Bearings, Bush, Canopy,down rods etc will be measured and paid sperately under respective items.
(iii) Total service time from taking down to rehanging must not exceed 03 Days .
(iv) Cost of T&P & transportation including taking down and re-fixing are included in the quoted rate | 1,050 | EACH JOB | - | - |
| 2 | Material & Labour for re-winding of ceiling fan 1200mm/1400mm sweep of copper winding with proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to department , tachometer will be provided by contractor at their own expense) and all insulating materials (spares will be used and measure in respective items) and reasembling etc complete all as specified and directed.
Notes for Sr No 2 to 5 :-
(i) The fans should be re-winded as per existing guage copper winding . Schedule of credit deducted as per the burnt out winding.
(ii) Before winding of fans winding to be cut in front of Engr-in-Charge.
(iii) Under defect liability period, in case winding or any accessory i.e capacitor, regulator becomes non functional, it will be repaired without any extra cost within 05 days of complaints received. | 400 | EACH JOB | - | - |
| 3 | All as per item No 2 above but for exhaust fans any type of size 150 mm sweep to 380 mm sweep complete all as specified and as directed. | 130 | EACH | - | - |
| 4 | All as per item No 2 above but for exhaust fan any type of size 450 mm sweep complete all as specified and as directed. | 10 | EACH | - | - |
| 5 | All as per item No 2 above but for wall fan of any size complete all as specified and as directed. | 80 | EACH | - | - |
| 6 | Material & Labour for replacement of defective ball bearing for ceiling fans/exhaust fans/Air-circulators/Wall fan of any size and of any make complete all as specified and as directed. | 620 | EACH | - | - |
| 7 | Material & Labour for replacement of defective Shaft for ceiling fans/exhaust fans/Air-circulators/wall fan of any size and of any make complete all as specified and as directed. | 250 | EACH | - | - |
| 8 | Material & Labour for replacement of defective gear box for wall fan of any size and of any complete all as specified and as directed. | 50 | EACH | - | - |
| 9 | Material & Labour for replacement of defective swing motor for wall fan of any size and of any make complete all as specified and as directed. | 60 | EACH | - | - |
| 10 | Material & Labour for replacement of defective capacitor of size 2.5 mfd ISI marked for any type of fans suitable for 250V/230V including making connection complete all as specified and directed. | 300 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
CREDIT8848.pdf
Additional Documents • 0.05 MB
BOQ_880124.xls
BOQ • 0.45 MB
TD8848.pdf
Tender Documents • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].