Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.6 L+₹3.9 L (10.6%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹43.6 L+₹6.9 L (18.8%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹48.2 L+₹11.4 L (31.1%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹48.3 L+₹11.6 L (31.5%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
22 Feb 2022, 6:00 pmClosed
GE(NW) BAHDNUP
GE(NW) BAHDNUP, MUMBAI
REPAIRS/ REPLACEMENT OF STREET LIGHTS AND LT CABLE AND DG SETS AT POWAI UNDER GE(NW) BHANDUP
2022_MES_499253_2
8174
Open Tender
Civil Works
Works
270 days
POWAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹68,000
Yes
20 May 2022
8 Feb 2022
23 Feb 2022
8 Feb 2022
22 Feb 2022
15 Feb 2022
Amount
Taking down HPSV / MH street light fitting and Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.. Make: Philips / Keselec / Osram
Taking down HPSV / MH street light fitting and Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.. Make: Philips / Keselec / Osram
Taking down HPSV / MH street light fitting and Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.. Make: Philips / Keselec / Osram
Supply & fix in repairs LED post top lattern fitting 40 watts made out of cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete. Make PHILIPS/WIPRO/CROMPTON
Taking down HPSV / MH street light fitting and Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.. Make: Philips / Keselec / Osram
Supply and drawing through the pole for making connectiion to the light fittings 3 Core, Copper cable,PVC insulated and sheathed heavy duty 1100 volt grade multistranded copper conductor (FRLS) cable 1.5 sqmm complete all specified and directed
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 150 x 140 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to wall all as specified and directed Make : Sintex/national
Taking out existing terminal box and S&F Pole mounting type weather proof FRP terminal box of size 250 x 175 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and aluminium bus bar for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to street light pole with suitable G I iron flat of size 25 x 3 mm clamps fixed with GI Bolts, nuts and washer of suitable sizes all as specified and directed Make : Sintex/National
Taking down HPSV / MH street light fitting and Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp Make: Philips / Keselec / Osram
Taking out old unsv steel tubular sewaged pole/PCC pole with all necessary earth work all as specified and directed
Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Supply and fix in repairs pipe bracket made out of 25/35 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Taking down unserviceable LT cable complete all as specified and directed
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm x 4 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm x 3.5 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm x 3.5 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm x 3.5 core
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm x 3.5 core
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply and spreading sand in trenches as cushioning to under ground cable on top and bottom of cable all as specified.
M&L in repairs of GI pipe 80 mm dia light grade with all fittings for cable protection .
M&L in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection .
Supply and fix in repairs of MCCB 100 Amps 4 Pole, with breaking capacity 25 KA, as per site requirement and complete all as specified and directed.
Supply and fix in repairs of MCCB 160 Amps 4 Pole, with breaking capacity 25 KA, as per site requirement and complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 415V, abjustable type, 50Hz 250 Amps 36 KA ,as per site requirement with sheet metal enclosure complete all as specified and directed .
Supply and fixing in repairs MCCB 3 pole 415V, abjustable type, 50Hz 63 Amps 16 KA ,as per site requirement with sheet metal enclosure complete all as specified and directed .
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified and directed by Engr in Charge
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified.
PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified.
Supply and fixing in repairs analog timer switch 3P module, 24 Hrs programme complete all as specified and directed
Supply and fixing in repairs digital timer switch 3P module, 24 Hrs programme complete all as specified and directed
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M&L for LT straight through joint heat shrinkiable kit suitable for 3 ½ / 4 core of size 10 to 16 sqmm underground cable all as specified and directed.
All as per item no.37 above but 25 to 50 sqmm
All as per item no.37 above but 70 to 120 sqmm
All as per item no.37 above but 150 to 185 sqmm
S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 130 mm ,made out of 3 mm thick HT sheet alongwith base plate of size 220x220x12mm ,including 1500 mm long single/double arms bracket made out of 48 mm dia,GI pipe,M20 in PCD 205 mm,700mm long and projected 100mm,"J" type EN8 grade set of 4 Nos foundation bolts along with tempalates,also including provision of the followings :- a)MCB,SP,6A,230v,B series,10KA mounted on and including 3 mm thick plastic laminated sheet-01 No. b) 4 way connector ,bolt type having locking arrangement,weather proof and water proof control space: 01 No. Notes :- a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete. b) The rate quoted shall also be deemed to include the cost for connecting with including suitable lugs of the existing incoming and outgoing LT UG cable of any size in the pole box of new octagonal pole. c) The concrete for foundation ,Reinforced and form work will measured and paid seperately. d) The existing light fittings retrived from item No 01 here in before shall be refixed at the pole and the quoted rate shall also be deemed to include the cost of above mentioned element. e) The excavation and earth work for foundation of pole shall be measured and paid separately in case the new poles are provided at different locations as compared to old poles dismantled vide item no 1 here in before . Make :- Bajaj model BOP-7030 or its equivalent in Crompton/Phillips/Wipro as approved by the GE.
M&L Carrying out 'B' check for 82.5 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
All as per item No 43. above but 75 KVA capacity
All as per item No43. above but 50 KVA capacity
All as per item No 43. above but 7.5 KVA capacity
All as per item No 43 above but 160 KVA capacity
Supply only Engine oil grade 20 W 40 for incorporation against item No. 01 Make : Castrol/Servo
Supply only coolant for DG set radiator complete all as specified.
Supply only oil filter suitable for 82.5 KVA DG set capacity as per existing size complete all as specified and diretced, Make- Kirloskar/Mahle/C&G/Leyland
All as per item No 51 above but 75 KVA capacity
All as per item No 52 above but 50 KVA capacity
All as per item No 53 above but 7.5 KVA capacity
All as per item No 54. above but 160 KVA capacity
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 82.5 KVA DG set
All as per item No 55 above but 75 KVA capacity
All as per item No 55 above but 50 KVA capacity
All as per item No 55 above but 7.5 KVA capacity
All as per item No 55 above but 160 KVA capacity
S&F in repairs of fan belt suitable for DG set of 50 to 200 KVA capacity complete all as specified and directed , Make- FENNER/Roflex/Vegrip
S&F in repairs of fan belt suitable for DG set 7.5 KVA capacity complete all as specified and directed , Make- FENNER/Roflex/Vegrip
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 82.5 KVA
All as per item No 62 above but 75 KVA capacity
All as per item No 62 above but 50 KVA capacity
All as per item No 62 above but 7.5 KVA capacity
All as per item No 62 above but 160 KVA capacity
Repairing radiator for 82.5 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
All as per item No 67 above but 75 KVA capacity
All as per item No 67 above but 50 KVA capacity
All as per item No 67 above but 7.5 KVA capacity
All as per item No 67 above but 160 KVA capacity
S&F in repairs solenoid switch for DG set upto 200 KVA capacity complete all as specified and directed by Engg-in Charge
Repairs AMF Panel of any type and any make as per the site requirement complete all as specified and as directed by Engg-in Charge
Material and labour for disconnecting / dismantling of self starter from DG set 82.5 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
All as per item No 74 above but 75 KVA capacity
All as per item No 74 above but 50 KVA capacity
All as per item No 74 above but 7.5 KVA capacity
All as per item No 74 above but 160 KVA capacity
Material and labour for servicing and overhauling of dynamo including replacement of unsv parts such as carbon brush, armature winding, varnishing of coil and reassembling and fitted with the engine including testing complete of capacity 12 volts complete all as specified and directed.
Material and labour for painting of DG sets of 75 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Material and labour for painting of DG sets of 160 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Material and labour for painting of DG sets of 7.5 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Supply and fix in repair unserviceable Maintenance free battery 180 Ah 12 volts complet all as specified and directed. Make Exide/Amron
Supply and fix in repair unserviceable battery lead copper lead with brass terminal complete suitable for DG set 7.5 KVA to 160 KVA all as specified and directed. Make Exide/Amron
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 82.5 KVA DG set complete allas specified and directed
All as per item No 85 above but 75 KVA capacity
All as per item No 85 above but 50 KVA capacity
All as per item No 85 above but 7.5 KVA capacity
Material and labour for replacement of asbestose rope 6mm dia complete all as specified and directed.
Supply and fixing in repairs electronic based generator controller unit model No GCU101 suitable for 50 KVA generator set including testing complete all as specified and as directed.
Dismantling the UNSV Automatic voltage Regulator of the 75 KVA DG set and replacement of the same with new as per existing make and size and fixing and testing complete
M&L for TMT steel bars 10 mm dia and over in reinforcement cut to length,bent to shape required,including cranking bending spirally forhooping for coloumns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc, complete all as specified and directed
M&L for TMT steel bars 6 to 8 mm dia as in strirups, spacers, binders cut to length,bent to shape required,including cranking bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc, complete all as specified and directed
M&L for use and waste of formwork to sides of concrete foundations, footing, columns, posts pillars etc and in any location for fair finished surfaces,complete all as specified and directed
Deduct Credit for Demolished/ Dismantled material Rs. (-) 72900.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
Radha Engineering Services
joshua construction
GOPAL ENTERPRISES
M/s A G POUL
M/S VISHRANTA CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .