Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.0 L+₹8,075 (1.36%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.1 L+₹18,780 (3.16%)Rejected-Finance | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Avani Nirman L2 | RAY VISION CONSTRUCTION LLP L3 | SHRI SAII SAMARTHA ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.01 | Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool confirming to IS: 8183, density 48 kg/m3. 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. | 172 | SQM | 560 ₹96,320 Lowest | 2,200 ₹3,78,400 | 1,450 ₹2,49,400 |
| 1.02 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling, including disposal of unservicable material and stacking of servicable material within 50 meters lead as directed by Engineer-In-Charge. | 167 | SQM | 2,725 ₹4,55,075 | 200 ₹33,400 Lowest | 850 ₹1,41,950 |
| 1.03 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595 x 595mm of approved texture, design and pattern. The tiles should have humidity resistance (RH) of 99%, Light Reflectance > 85%, Thermal conductivity k=0.052-0.057 w/m K. Fire performance as per (BS 476 pt -6 & 7) in true horizantal level suspended on interlocking T-Grid of hot dipped all roound galvanised iron section of 0.33mm thick (galvansized @120 gsm) comprising of main T runners of 15 x 32 mm of length 3000mm, cross T of size 15 x 32mm of length 1200mm and secondary intermediate cross T of size 15 x 32mm of length 600mm to form grid module of size 600 x 600mm suspended from ceiling using galvanised mild steel item (galvanised @ 80gsm) 50mm long 8mm outer diameter M-6 dash fasteners, 6mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2mm, spaced at 1200 mm centre to centre along main 'T'. The system should rest on periphery walls/ partitions with the help of GI perimeter wall angle of size 24x24x3000 mm made of 0.40 mm thick sheet to be fixed to the wall with the help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked, for all heights. The work shall be carried out as per specifications, drawings and as per the direction of the engineer-in-charge i) With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7) | 167 | SQM | 300 ₹50,100 Lowest | 1,200 ₹2,00,400 | 1,210 ₹2,02,070 |
Tender Value
₹6.3 L
EMD Value
₹12,650
Closing Date
9 Jan 2026, 11:00 amClosed
Executive Engineer (Civil), IWD, IIT GOA
Executive Engineer (Civil), IWD, IIT GOA
Acoustic Control in Conference room at Academic block-II
2026_ITG_892192_1
IITGOA/IWD/2025/22 dtd.01.01.2026
Open Tender
Civil Works
Item Rate
30 days
IIT Goa transit campus at GEC Farmagudi
As per tender documents
2 documents required · 2 mandatory
₹0
₹12,650
10 Oct 2026
1 Jan 2026
10 Jan 2026
1 Jan 2026
9 Jan 2026
1 Jan 2026
1 Jan 2026 - 9 Jan 2026
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool confirming to IS: 8183, density 48 kg/m3. 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling, including disposal of unservicable material and stacking of servicable material within 50 meters lead as directed by Engineer-In-Charge.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595 x 595mm of approved texture, design and pattern. The tiles should have humidity resistance (RH) of 99%, Light Reflectance > 85%, Thermal conductivity k=0.052-0.057 w/m K. Fire performance as per (BS 476 pt -6 & 7) in true horizantal level suspended on interlocking T-Grid of hot dipped all roound galvanised iron section of 0.33mm thick (galvansized @120 gsm) comprising of main T runners of 15 x 32 mm of length 3000mm, cross T of size 15 x 32mm of length 1200mm and secondary intermediate cross T of size 15 x 32mm of length 600mm to form grid module of size 600 x 600mm suspended from ceiling using galvanised mild steel item (galvanised @ 80gsm) 50mm long 8mm outer diameter M-6 dash fasteners, 6mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2mm, spaced at 1200 mm centre to centre along main 'T'. The system should rest on periphery walls/ partitions with the help of GI perimeter wall angle of size 24x24x3000 mm made of 0.40 mm thick sheet to be fixed to the wall with the help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked, for all heights. The work shall be carried out as per specifications, drawings and as per the direction of the engineer-in-charge i) With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_937781.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .