Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
15 Jul 2020, 6:00 pmClosed
CWE Lucknow
229 MG ROAD LUCKNOW CANTT
REPAIR/MAINT OF POWER TRANSFORMER AND CONNECTED WORKS AT VARIOUS LOCATIONS UNDER GE E/M LUCKNOW
2020_MES_353620_1
CWE/LKO/EM/T-07 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
MES contractors enlisted in Class D and category b(ii) and for un enlisted contractors meeting the enlistment criteria corresponding to value class and category of work and having executed similar nature of work
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹60,000
Yes
21 Aug 2020
17 Jun 2020
17 Jul 2020
17 Jun 2020
15 Jul 2020
3 Jul 2020
Amount
M&L for breather unit with superior quality blue colour silica jelly and fill up the oil maintain the exact level suitable for transformer of cap 5 MVA, 33/11 KV complete all as specified and directed.
do- all as above but for 33 / 0.433 KV, 25 KVA (Station Transformer)
Supply & Fixing HV bushing 33KV for transformers complete all as specified.
Supply only LV bushing for transformers complete all as specified.
Supply only HV spindles (metal Part) of brass with nuts and washers complete all as specified
Supply only LV spindles (metal Part) of brass with nuts and washers complete all as specified
M&L for Cleaning, servicing and testing complete 33/11 KV switch yard, various equipment, over head line complete all as specified and directed for the following:-
(a) line isolator, 33 KV (Horizontal type) :- Servicing of line isolator (Horizontal break outdoor type) including cleaning of contact (knife) by CTC liquid proper oiling greasing on contacts & moving rod / handle for proper function of moveable rod for smooth ON / OFF position and checking the incoming and outgoing connection (terminal lugs to be replaced if required) and testing with following (i) Meggar testing between phase to phase & phase to earth shall be carried out .
(b) HT Potential Transformer (33 KV / 110 Volt) :- Cleaning of bushing and terminal of HT potential transformer 33000 / 110 volts (outdoor type) by CTC liquid and checking of oil level and oil dielectric strength (BD test) and proper connection checking and testing with following :- (i) Meggar testing between phase to phase& phase to earth (ii) Output voltage checking
(c) HT Vacuum Circuit Breaker (VCB) 33 KV: Cleaning & servicing of HT 33 KV vacuum circuit breaker (VCB) 400 Amp, 3 phase, 13.1 KA outdoor type, checking of each moving parts, spring, charging system, closing & trip coil assembly and proper oiling, greasing and proper adjustment of trip bars, closing bar complete with the following testing :- (i) ON/OFF testing in local and remote position. (ii )Spring charge system testing shall be carried out. (iii) Tripping test in over and earth fault position by external current injecting Kit on Primary Secondary side. (iv) Meggar testing between phase to phase and phase to earth in ON / OFF position both.
(d) HT 33 KV Current Transformer (CT): Cleaning of bushing and terminal by CTC solution of CT rating 100 / 5 + 5 + 1 Amp rating, 33 KV and checking of oil level and oil strength (BD voltage test) and proper connection checking and testing with following :- (i) Meggar testing between phase to phase& phase to earth
(f) Transformer 33 / 11 KV, 5 MVA :- Cleaning of power transformer 33 /11 KV, 5 MVA, outdoor type externally including all accessories (such as conservator tank, marshaling box, bushings, bucholz relay Radiator, bushings oil level indicator) complete and checking the incoming and outgoing terminal connection complete with the following testing :- (i) Transformer oil dielectric strength (BD voltage) test. (ii) Buccholz relay Alarm & trip testing. (iii) Oil temperature Alarm & trip testing. (iv) Winding temperature Alarm & trip testing. (v) Meggar testing between HV to earth. (vi) Meggar testing between LV to earth. (vii) Meggar testing between HV to LV . (viii) Earth resistance test of transformer neutral. (ix) Earth resistance test for body earthing. (x) Replacement the all packing in marshalling box (if required)
(g) Transformer 33/ 0.433 KV, 25 KVA (Station Transformer) :- Cleaning of station transformer (outdoor type) externally including all accessories and checking of all incoming & outgoing connection with the following testing :- (i) Transformer oil dielectric strength (BD) test. (ii) Meggar testing between HV to earth. (iii) Meggar testing between LV to earth. (iv) Meggar testing between HV to LV . (v) Earth resistance test of transformer neutral. (vi) Earth resistance test for body earthing.
(h) D.O. Fuse: Cleaning of HT insulators & checking the incoming & outgoing joint connection and testing with the following :- (i) Meggar testing between phase to phase& phase to earth.
M&L for painting of 33 /11 KV Old MRS switch yard MS structure with two coats of aluminum paint after cleaning and making good surface for panting of the following structure:- (a) Bus bar Gantry:- Painting of busbarGantry of MS channel (I Section) size 150 mm x 75 mm x 5 mtr long - 12 Nos (b) Lightening arresters (LA):-Painting of lightening Arresters of MS channel (C-section) of size 100 mm x 50 mm x 3.0 mtr long -02 Nos with MS Angle iron 50x 50 x 2.5 mtr long -04 Nos complete - 03 Job (c) Line isolator (LI):- Painting Line isolator of MS channel ( C-section) of size (125 mm x 50mm x 3.00 mtr long -04 Nos) and ( 100 mm x 50 mm x 1.00 mtr -02 Nos) with MS flat bracing (50mm x 50mm x 0.30 mtr -6 Nos) and MS Angle iron ( 50 mm x 50 mm x 2.5 mtr long-02 Nos) complete -07 Job (d) Horn Gap fuse:- All as per item No 12 (C) here in before. Qty - 04 Job (e) VCB / CT / PT stand:- Painting of CT PT VCB structure made out of MS channel ( C-section) of size ( 100 mm x 50 mm x 2.30 mtr long- 04 Nos) and ( 100 mm x 50 mm x 0.80 mtr long- 04 Nos) and ( 100 mm x 50 mm x 1.90 mtr long- 04 Nos) and Angle iron of size ( 50 mm x 50 mm x 1.10 mtr long- 04 Nos), ( 50 mm x 50 mm x 0.70 mtr long- 06 Nos) and (50 mm x 50mm x 0.25 Mtr long - 05 Nos) complete -03 Job (f) Pin insulator supporting structure(Station Transformer):- Painting of structure made out of MS channel (C- section) of size (100mm x 50mm x 3.00 mtr long- 02 Nos) with Angle iron of size (50mm x 50 mm 2.50 mtr long - 04 Nos) complete -01 Job.
Cleaning of transformer outer surface suitable for painting 5 MVA, 33 / 11 KV rating in 33 KV switch yard at main receiving station and painting with two coat of synthetic enamel paint by spray machine of light grey colour or as approved by Engineer-in-Charge including transformer accessories such as radiator, conservator tank, marshalling box etc complete all as specified and directed. (Note:- Colour of paint to be approved by EIC before painting)
All as per item No. 9 above but station transformer 33 / 0.433 KV, 25 KVA rating.
All as per item No. 9 above but of size approx (outdoor type), 400 Amps rating size of VCB 700 mm wide x 500 mm deep x 900 mm height including painting of CT's & PT's all as directed by EIC.
All as per item No. 9 above but VCB control panel (indoor type) of size approx 650 mm wide x 550 mm deep x 1950 mm height complete all as specified and directed
Supply and fixing (in replacement) of faulty oil temperature indicator with trip and alarm contacts complete all as specified and directed.
Supply and fixing in repairs spring charging motor suitable for fixing with 33 KV outdoor/indoor type VCB panels complete all as specified and directed.
Supply & topping up transformer oil low viscosity, dielectric strength above 50 KV confirming to IS-335 complete for filling / topping up in HT CT/PT Transformers complete all as specified and directed.
M&L centrifuging of transformer oil 33/11 KVA 5 MVA power transformers including filter action using automatic centrifuging machine to achieve minimum 35 to 40 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particle for use all as specified and directed.
Hiring of cable fault detector, to detect exact position of fault for XLPE /PVC LT/HT cable, 1100/11000 Volts grade heavy duty aluminum conductor of any size including to and fro transporting charges etc. all as specified and directed.
M and L for opening the top cover of current transformer of VCBs 11 KV and servicing of fixed and moving contacts, repair and replacement of defective components of panel board, lamp indicators, calibration of digital meters, over load protection relay, time delay relay / earth fault relay, charging spring etc. Cleaning the fixed and moving contact inside the VCBs properly, servicing and greasing all moveable mechanism, replacement of defective fuses, wiring and reassembling and testing complete all as per the direction of Engineer-in-Charge.
Supply and fixing in repairs 2U hardware clamp straight or angle to clamping the jumper & disc insulators uses with suitable nut, bolt, and washers complete.
All as per item No 19 but sub station connector of Aluminum straight tee tubing main to tubing tap with suitable sizes of nut & bolts complete.
All as per item No 19 but sub station connectors Aluminum horizontal bus support tube to insulators with nut & bolts complete.
All as per item No 19 but Aluminum straight tee tubing main to cable/conductor tap complete.
Supply and fixing aluminum binding wire 14 SWG suitable for binding the jumpers and other accessories of 4 pole structure complete.
Supply and fixing in repairs MS nuts and bolts as per sample kept in office complete all as specified and directed.
Supply only Electrical Rubber Hand Gloves 33 KV Rating all as specified.
M&L for disconnecting burnt end or portion of 25 sqmm to 185 sqmm 3 ½ core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and relaying the same, and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals of LT/HT cable to pole / main switch etc complete all as specified.
Taking out old unserviceable tap changer switch and S&F new tap changer switch for 5 MVA power transformers complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required of size 20x3.15 mm copper strip complete.
Supply and install HT 33 KV outdoor type gang operated air-breaker switch suitable for horizontal or vertical mounting fixed type compete with having 9 insulators of rating up to 400 Amps complete all as specified and directed.
Supply and fixing in repairs temperature indicator complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required of size 32x6mm Galvanised mild steel strip complete.
M&L 60mm thick PCC interlocking tiles, rubber moulded using grey cement and pigment of size and shape as approved, including 50mm thick bed with PCC (1:3:6) type C1 with 20 mm graded aggregate and including layer of dry sand not less than 40 mm thick, interstices filed in floors/pathway including locking the tiles on all four sides with PCC complete all as specified and directed.
M&L for spreading of coarse aggregates grate- I, 90 to 40 mm size or grading-II, 63 to 40 mm size complete all as specified and directed.
M&L for sand filling for cable protection in duct complete all as specified and directed.
M&L for HT cable duct cover made of RCC as per site complete all as specified and directed.
Supply and fix in repairs earth fault Relay (inverse) type ISI marked for 33 KV complete all as specified and directed.
Supply & fixing wooden discharge rod PVC coated suitable for 11 KV complete with all accessories as specified and directed.
Supply & fixing wooden discharge rod PVC coated suitable for 33 KV complete with all accessories as specified and directed.
M&L for aluminum conductor steel reinforced (ACSR) on pole, stringing properly on insulators and binding with aluminum binding wire, jumpers etc complete for any size (Ferret,Weasel,Squirel) of conductor complete. Note : - Measurement & Payment shall be made by measuring horizontal distance between centre of two adjacent pole and adding 3% extra for sag, joints and jumper etc.
Supply & fix insulator pin type porcelain, vitreous, white, brown or green 150 mm height and 150 mm dia including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nuts for conductor working pressure 11000 Volts grade complete.
Supply & fix insulator disc type porcelain, vitreous, white, brown or green including galvanised mild steel straps, washers,insulator bolts, washers and nuts 150 mm height and 150 mm dia including working pressure 11000 Volts grade complete.
M&L for MS work fabricate, fixing anti climbing device spike type of MS bars (round square or flae) including nuts, bolts, washers , and welding in two halves made to shape to suit the cross section of the poles including painting with two coats of aluminum paint over a coat of red oxide primer complete.
Supply & fixing cable rout indicator made out of cast iron suitable size supported on MS angle iron embedded in PCC 1:4:8 with engraved size of cable and direction of rout complete.
Servicing / Cleaning of solar street light PV module, checking the all electric loose connection, replacement of terminal, distilled water of battery, where fitting Checking of mechanical/electric system for proper functioning of solar lights at various places complete all as specified and directed.
Cleaning of 33 KV Electric main receiving station include removing of grass, bushes and trimming of branches of trees inside the premises of substation complete all as specified and directed.
Supply and fixing lightning arrester, HT, suitable for 33 KV, expulsion type complete with all fittings, transmission class, discharge capacity 10 KA complete and connecting to conductors and earthing all as specified.
Servicing / Cleaning of inverter/ups checking the all electric loose connection, replacement of terminal, distilled water of battery, wiring system Checking of mechanical/electric system for proper functioning of inverter at various places complete all as specified and directed.
Diamond Electric Co.
Shree Tirupati Associates
Unnati Engineers
Prime power system
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .