Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹6.2 L+₹24,014 (4.02%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Being not L1. | |
| 3 | L3₹6.9 L+₹94,094 (15.8%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Being not L1. | |
| 4 | L4₹7.2 L+₹1.2 L (20.5%)Rejected-Finance | L4 | Rejected-Finance Being not L1. | |
| 5 | L5₹8.1 L+₹2.2 L (36.4%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Being not L1. |
Tender Value
₹7.7 L
EMD Value
₹15,400
Closing Date
1 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MC Chandigarh
GE (AF) MC Chandigarh
REQUIREMENT OF WORK SERVICES AT RSD (M) FOR TRAIL TRANSMISSION BAY AT 3BRD AF STATION CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2021_MES_473382_2
GE (AF) MC /CHD -19/2021-2022
Open Tender
Civil Works
Item Rate
180 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹15,400
Yes
13 Nov 2021
12 Oct 2021
3 Nov 2021
12 Oct 2021
1 Nov 2021
19 Oct 2021
60 days
Amount
Material and labour for flame proof point wiring on surface complete with 2.5Sqmm PVC insulated unsheathed multistranded copper cable FRHR in and including heavy duty ERW (stove enameled) conduit size not less than 19mm dia with MS saddle and spacer with flame proof junction box, bend, reducer, plug, flexible pipe, check nut independent for one light point controlled by one switch with 1.5Sqmm PVC insulated FRHR copper conductor cable as earth wire and connected to common earth and earth dolly as per IS specification, complete all as specified and directed. Note:- Switches etc. shall be measured and paid separately. Circuit wiring from distribution board to switch board shall be deemed included in the quoted rate of point wiring.
Material and labour for point wiring (Concealed) in and including rigid PVC conduit medium grade not less than 19mm dia, suitable as per site requirement including cutting chases for conduit, sinking for boxes for concealed conduit wiring with 1.5Sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable in and including flush type metal boxes modular type suitable for fixing modular switches, sockets, fan regulators etc with brass screws, cup washer, cover and cover plate and including PVC insulated unsheathed multi stranded copper conductor cable 1.5Sqmm as earth wire connected to common earth and earth dolly as per IS specification for one light/fan/bell point, complete all as specified and directed. (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii) Switches etc. shall be measured and paid separately. Circuit wiring from distribution board to switch board shall be deemed included in the quoted rate of point wiring.
Supply and fix, modular switch, one way, 6Amps, one module, complete all as specified and directed. Make:- Legrand/SSK/Anchor
Supply and fixing flame proof switch/isolator cast iron body 16Amp, single pole ON/OFF, 240 volts ML-6 (Rotary type) certified by CMRS and conforming to IS 2148, complete all as specified and as directed. Make : Sudhir/Baliga/Crompton.
Supply and fix, ceiling rose, surface bakelite/ polycarbonate/PVC isolated body, 65mm x 50mm, three terminals, complete all as specified and directed. Make:- Cona/SSK/Anchor
Supply and fix LED slim flat panel 36 Watt having lumen output more than 3200 lumen suitable for false ceiling of cut out size 2'x2' including making connection, complete all as specified and directed. Make :- Crompton cat part No. CCR-127-36-57-SL-NWH or equivalent in Philips/Wipro/Havells
Supply and fix LED flood light fittings 150W made up of pressure die cast aluminium housing with toughened glass and high power LED and secondary lenses with IP 66 protection, system efficiency > 110LPW including making connection, complete all as specified and directed. Make :- Crompton cat part No. LFLN-150-CDL/60M or equivalent in Philips/Wipro/Havells
Supply and fix FLP-WP flood light fittings suitable for 400W HPMV light fixed on roof/wall/column, complete all as specified and directed. Make:- Philips/Wipro/Havells/Crompton
Supply and fix exhaust fan, steel body, AC single phase, 230V of size 300mm sweep with blades and frame and louvers including cutting holes on wall and making good the disturbed surface with existing specification, complete all as specified and directed. Make :- CROMPTON/BAJAJ/KHAITAN/USHA
Supply and fix Sheet Metal Enclosure Distribution Board (DB), company made, metallic double door, single pole and neutral, 4way, 240Volt with 200Amps rated insulated bus bar, IP-43, complete all as specified and directed. Make:- Havells/Schnider/ABB/C&S
Supply and fix MCB SP 6-32Amps, 240volts, 10KA, 'C' curve, complete all as specified and directed. Make:- Havells/Schnider/ABB/Legrand/L&T
Supply and fix MCB DP 40 to 63Amps, 240volts, 10KA, 'C' curve, complete all as specified and directed. Make:- Havells/Schnider/ABB/Legrand/L&T
Supply and fix weather proof flame proof metalic sheet metal enclosure for DB approved by CMRI dhanbad of cast aluminium alloy RCP/198 type SPN 8 ways with and including 32 Amps SPN rotary switch as incomer with MCB SP 'C' series, 10KA 6-32 Amp - 06 Nos as outgoing, complete all as specified and directed. Make : Sudhir/Baliga/Crompton.
Material and labour for Sub Main Wiring with two single core 6Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including stove enamelled steel conduit of suitable size, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 4Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity, complete all as specified and directed. Make of cable:- Plaza/Finolex/Havells/Polycab
Material and labour for Sub Main Wiring with two single core 4Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including PVC regid conduit of suitable size, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 2.5Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity, complete all as specified and directed. Make of cable:- Plaza/Finolex/Havells/Polycab
Material and labour for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including Copper strip 20 x 3 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:3:6 using 12.50 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc, complete all as directed and specified. Note : (i) The earth pits shall be interconnected with each other with copper strip 20x3mm size and then connected to electric discharge eliminating plate. The cost of electric discharge eliminating plate including fixing and making connection shall be included in quoted rate. (ii) Note : The earth value/result must be less than 3 ohms.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:3:6 using 12.50 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc , complete all as directed and specified and as shown in electrical plate No. 3 of SSR Part-I. Note : The earth value/result must be less than 5 ohms.
Supplying, laying, testing, connecting and commissioning LT cable size 35Sqmm, 3.5core, 1100 Volts grade heavy duty XLPE insulated armoured with aluminium stranded conductor with suitable size cable glands, crimping type cable lugs etc, complete all as specified and directed. Make:- Havells/Polycab/KEI
Supply and fix cable tray stainless steel powder quoted of size 300mmx54mm in 03 metre length, complete all as specified and directed. Make:- YAMUNA DENSONS/ REW/GM
Supply and fix sheet metal enclosure for mounting MCCB 4 pole upto 250Amp including having cable entry and out arrangement, making connection with existing/new cable complete and fixing the enclosure on wall as per site requirement, complete all as specified and directed. Make:- Havells/Schnider/ABB/C&S
Supply and fix MCCB, 63Amps, 4pole, 415Volts, 50Hz, 25KA, with fixed thermal and magnetic setting, complete all as specified and directed. Make:- Havells/Schnider/ABB/Legrand/L&T
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 32 x 6 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:3:6 using 12.5 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc , complete all as directed and specified and as shown in electrical plate No. 3 of SSR Part-I. Note : The earth value/result must be less than 5 ohms.
SANJEEV ENTERPRISES
HARISH SALES CORPORATION
BANSAL ENGINEERING
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .