Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.3 LAccepted-AOC GOPALPUR BANSI RANIGANJ DISTRICT PRATAPGARH | PRATAPGARH | UTTAR PRADESH | 1 | Accepted-AOC L1 | |
| 2 | 2₹4.6 L+₹1.3 L (39.4%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹4.6 L+₹1.3 L (40.5%)Rejected-AOC 02 SILI JAGEER PIPLIYA BAHERI BAREILLY UTTAR PRADESH 243202 | BAREILLY | UTTAR PRADESH | 243202 | 3 | Rejected-AOC L3 | |
| 4 | 4₹4.8 L+₹1.5 L (45.9%)Rejected-AOC 16F 1K NEW MARKET BAMRAULI NEAR BAMRAULI RAILWAY STATION ALLAHABAD UTTAR PRADESH 211012 | PRAYAGRAJ | UTTAR PRADESH | 211012 | 4 | Rejected-AOC L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.5 L
EMD Value
₹6,500
Closing Date
8 Aug 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Superintending Engineer Electricity Transmission Circle I 57 George Town Prayagraj 211002
Replacement of damaged 33 KV Single Moose Bus Bar to new Single Moose Bus Bar at 132 KV Substation Malwan under Electy. Trans. Division- Fatehpur
2024_UPTCL_941548_1
10-ETC-I(A)/ 2024-2025
Open Tender
Miscellaneous Works
Item Rate
60 days
Malwan
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE,ETC,PRAYAGRAJ
₹6,500
21 Feb 2025
27 Jul 2024
9 Aug 2024
27 Jul 2024
8 Aug 2024
27 Jul 2024
Amount
Replacement of 33KV Main Bus bar of single ACSR Moose Conductor by Twin ACSR Moose Conductors along with other associated work at 132 KV Sub station Malwan, with all cost of Men & material (as per technical specification & sample) Mise consumables T&P etc required for satisfactory completion of the work as per technical specification and direction of the supervising engineer as per details below.
Supply of 02 No. U-Bolted type single suspension fitting assembly suitable for single ACSR moose conductors and 33 KV suspension Disc insulator string comprising of 03 No. 70 KN Disc insulators complete with hardware fitting socket eye. Ball hook yoke plate. J-hook etc, as per technical specifications & sample.
Supply of 05 No. U-Bolted type single tension fitting assembly with turn buckle, suitable for single ACSR moose conductors and 33 KV bus bar Disc insulator string comprising of 04 No. 70 KN Disc insulators, complete with hardware fittings D-Shacke, Socket eye, ball hook, yoke plate D-clip, tension clamp etc as per technical specification & sample.
Supply of 33 KV CT Bi-Metallic terminal connector duly made of LM-6 Aluminium Alloy alongwith Bi-Metallic sleeve/plat suitable for single ACSR moose conductors complete with 04 No. 12mm size G.I. Bolts Nuts, Spring & plain washers as per technical specifications & sample.
Supply of 33 KV isolator Bi-Metallic terminal connector duly made of Lm-6 Aluminium Alloy suitable for single ACSR moose conductors complete with 04 No. 12mm size G.I. Bolts Nuts, Spring & Plain washers as per technical specifications & sample.
Supply of 33KV CB Bi-Metallic terminal connector duly made of LM-6 Aluminium Alloy suitable for single ACSR Moose conductors complete with 04 No. 12 mm size G.I. Bolts Nuts, Spring & Plain washers as per technical specifications & sample.
Supply of 33 KV Bushing clamp for 40 MVA T/F duly made of LM-6 Aluminium Alloy suitable for single ACSR moose conductors complete with 04 No. 12 mm size G.I. Bolts Nuts, Spring & Plain washer as per technical specifications & sample.
Supply of 33 KV CT terminal connector duly made of LM-6 Aluminium Alloy suitable for single ACSR panther conductors with 04 No. 12 mm size G.I. Bolts Nuts, Spring & plain washers as per technical specifications & sample.
Supply of 33 KV CB terminal connector duly made of LM-6 Aluminium Alloy suitable for single ACSR panther conductors with 04 No. 12 mm size G.I. Bolts Nuts, Spring & plain washers as per technical specifications & sample.
Supply of 33 KV LSI & BSI terminal connector duly made of LM-6 Aluminium Alloy suitable for single ACSR panther conductors with 04 No. 12mm size G.I. Bolts Nuts, Spring & plain washers as per technical specifications & sample.
Opening of jumpers of ACSR moose/panther/conductors between existing 33 KV main bus conductors to main bus bar conductors to bus PT's & LA's 33 KV main bus isolators to CB, CB to CT's to LA's to LV bushing isolators to CB to CT, CT to LI, LI to transfer BI in various 33 KV feeders/transformer alongwith shifting of the dismantled conductors, clamps, connectors etc from switchyard to stores at the S/S (01 job for each Jumper).
De-stringing & dismantling of existing 33KV main bus bar of single ACSR moose conductors including De-hosting of Disc insulator tension string with associated tension fitting and Disc insulator suspension string with associated suspension fitting from Gantry alongwith shifting of the dismantled conductors tension fitting suspension fitting etc from switchyard to stores at the S/S (01 Job for each phase of each section of the main bus bar, Total-3 section).
Laying & Re-stringing of 33 KV main bus bar of twin ACSR moose conductors including hosting of disc insulator tension string with associated tension fitting and disc insulator suspension string with associated suspension fitting alongwith shifting of the new conductors, tension fitting suspension fitting, spacers etc. from stores at the S/S to the switchyard (01 Job for each phase of each section of the main bus bar, Total-3 section).
Jumpering with twin ACSR moose/panther conductors between newly laid 33 KV main bus bar conductors of twin ACSR moose conductors to main bus isolator 33 KV main bus bar conductors to bus section isolator and 33 KV main bus bar conductors to bus PTs & Las, 33 KV main bus bar conductors to bus PTs & LAs, 33KV main bus isolator to CB, CB to CTs, CTs to LAs, LAs to LV bushing of in 33KV side of 40 MVA T/F-I & II & III and 33 KV main bus isolators to CB, CB to CT, CT to 1.1, 11 to transfer BI in various 33 KV feeders/transfer bus isolator by due cutting & bending of conductors and tightening of the jumpers with P.G. clamps/equipments terminal connectors etc. alongwith shifting of the conductors P.G. clamp. Equipments connectors etc. from sotres at the S/S to the switchyard (01 Job for each Jumper).
HARE KRISHNA ENERGY PROJECTS
LASHANI ENTERPRISES
R.S.ASSOCIATE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .