Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.2 LQualified Make: HIOKI
Model: HIOKI-PQ3100-94 4 5 2 TULSI CHAMBERS 4TH FLOOR OLD PALASIA INDORE MADHYA PRADESH 452018 | INDORE | MADHYA PRADESH | 452018 | Make: HIOKI
Model: HIOKI-PQ3100-94 | L1 | Qualified MSE | |
| 2 | L2₹4.5 L+₹38,555 (9.26%)Qualified Make: Metrel
Model: Metrel MI 2885 FLAT NO 4 ANANDNIWAS APARTMENT I F PANCHSHIL APT SHREE SADGURU NAGAR MARG GOVIND NAGAR NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | Make: Metrel
Model: Metrel MI 2885 | L2 | Qualified | |
| 3 | L3₹5.0 L+₹78,555 (18.9%)Qualified Make: FLUKE
Model: FLUKE-435-II KODICHIKKANAHALLI BANGALORE CITY KARNATAKA 560076 INDIA | BENGALURU URBAN | KARNATAKA | 560076 | Make: FLUKE
Model: FLUKE-435-II | L3 | Qualified MSE | |
| 4 | L4₹5.0 L+₹84,475 (20.3%)Qualified Make: FLUKE
Model: FLUKE-435-II 122 KANCHAN BAGH KANCHAN BAGH KANCHAN BAGH INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: FLUKE
Model: FLUKE-435-II | L4 | Qualified | |
| 5 | L5₹5.1 L+₹88,595 (21.3%)Qualified Make: FLUKE
Model: FLUKE-434-II 00 ASHOK NAGAR GURSAHAIGANJ KANNAUJ UTTAR PRADESH 209722 | KANNAUJ | UTTAR PRADESH | 209722 | Make: FLUKE
Model: FLUKE-434-II | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
20 Jul 2018, 7:00 pmClosed
power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase
Three phase Number of Current Channels (Nos.) 4 1
2
3
4 Number of Voltage Channels 4 1
4 Measurable voltage range 1000 600
1000 Measurable voltage accuracy 0.5 0.04
0.1
0.2
0.5
1 Measurable voltage resolution 0.1 1
0.1 Measurable current range (with clamp) 5000 5000
2000 Measurable current accuracy (%) ±0.5 ±0.04
±0.1
±0.2
±0.5
±1 Measurable current resolution 0.1 0.1
1
10 Maximum power that can be measured (KW) 400 4
40
400 Power Accuracy (%) ±1.5 ±1.5
±2
±2.5 Power resolution 1 1
5
50
500 1/5 MEASUREMENT FEATURES Facility to Measure Frequency Available - Frequency range that can be measured 40-65 Hz - Facility to Measure Inter harmonics Not-Available - Order(n) to which Facility to Measure Harmonics available upto 50th - Facility to Measure Power Factor Available - Accuracy in measurement of Power Factor (%) 0.1 - Facility to Measure Distortion Factor Not-Available - Accuracy in measurement of Distortion Factor (%) NA - Facility to Measure Ripple Factor Not-Available - Accuracy in measurement of Ripple Factor (%) NA - Facility to Measure crest factor Available - Measurable crest factor range 1 TO 10 - Measurable crest factor accuracy (%) 5 - Measurable crest factor resolution 0.01 - Facility to Measure sag(dips) and swell(surge) Available - Pattern of measurement of sag(dips) and swell(surge) trend - Facility to Measure Total Harmonic distortion Available - Accuracy in measurement of Total Harmonics distortion 2 - Facility to Measure voltage and current unbalance Available - 2/5 Facility to Measure inrush current Available - Facility to Measure flicker Not-Available - DISPLAY Display type LCD Backlit - Display Mode Waveform
Meter Reading
Bar graph
Vector
digital reading - GENERAL FEATURES Facility to Measure RMS Voltage Available - Facility to Measure RMS Current Available - Facility to Measure Active
Reactive and Apparent Power Available - Facility to Measure Active
Reactive and Apparent Energy Available - GENERIC Data transfer software provided for analysis on PC Yes - Provision for external SD Card yes - Interface USB - Internal Memory (GB) 4 - Weight of the analyser 1.5 - other features THREE PHASE POWER QUALITY ANALYZER - POWER SOURCE/BATTERY Power Supply Battery operated
230 V AC +/- 10%
50Hz - If battery operated
chemistry of the rechargeable battery lithium ion - Voltage of rechargeable Battery 10.8 - capacity of rechargeable battery (milli AH) 2400 - Suitable charger adaptor provided yes - Battery backup (hours) 8 - OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Temperature 50 - 3/5 Operating Humidity (%) 90 - ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser BC430 Power Adapter
International plug adapter set
BP290 (Single capacity Li-ion battery) 28 Wh (8 hours or more)
TLS430 Test lead and Alligator clip set
WC100 color coding clips and regional decals
i430flex-TF
24 inch (61 cm) length
4 flexible current probes
8 GB SD card
Power Log on CD (includes operator manuals in PDF format) USB cable A - Mini B
C1740 Soft Case - SAFETY Compliance to IEC 61000-4-30 Yes - Category of safety rating Category IV 600 V of IEC 61010 - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes - conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes - Availability of Test Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Yes - Test Report Number FLUKE/2018/5632456 - 4/5 and date DTD. 15.03.2018 Name and address of the Lab FLUKE CORPORATION
USA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Snehil Srivastav 403711
Naval Armament Depot Goa Chicalim P O Vasco- da- Gama 1 20 Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 10.00 Duration of ePBG required (Months). 14
302341
GEM/2018/B/42903
power quality analyzers
20 days
Goa; South Goa
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase | - | - | - |
| Three phase Number of Current Channels (Nos.) 4 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 Number of Voltage Channels 4 1 | - | - | - |
| 4 Measurable voltage range 1000 600 | - | - | - |
| 1000 Measurable voltage accuracy 0.5 0.04 | - | - | - |
| 0.1 | - | - | - |
| 0.2 | - | - | - |
| 0.5 | - | - | - |
| 1 Measurable voltage resolution 0.1 1 | - | - | - |
| 0.1 Measurable current range (with clamp) 5000 5000 | - | - | - |
| 2000 Measurable current accuracy (%) ±0.5 ±0.04 | - | - | - |
| ±0.1 | - | - | - |
| ±0.2 | - | - | - |
| ±0.5 | - | - | - |
| ±1 Measurable current resolution 0.1 0.1 | - | - | - |
| 1 | - | - | - |
| 10 Maximum power that can be measured (KW) 400 4 | - | - | - |
| 40 | - | - | - |
| 400 Power Accuracy (%) ±1.5 ±1.5 | - | - | - |
| ±2 | - | - | - |
| ±2.5 Power resolution 1 1 | - | - | - |
| 5 | - | - | - |
| 50 | - | - | - |
| 500 1/5 MEASUREMENT FEATURES Facility to Measure Frequency Available - Frequency range that can be measured 40-65 Hz - Facility to Measure Inter harmonics Not-Available - Order(n) to which Facility to Measure Harmonics available upto 50th - Facility to Measure Power Factor Available - Accuracy in measurement of Power Factor (%) 0.1 - Facility to Measure Distortion Factor Not-Available - Accuracy in measurement of Distortion Factor (%) NA - Facility to Measure Ripple Factor Not-Available - Accuracy in measurement of Ripple Factor (%) NA - Facility to Measure crest factor Available - Measurable crest factor range 1 TO 10 - Measurable crest factor accuracy (%) 5 - Measurable crest factor resolution 0.01 - Facility to Measure sag(dips) and swell(surge) Available - Pattern of measurement of sag(dips) and swell(surge) trend - Facility to Measure Total Harmonic distortion Available - Accuracy in measurement of Total Harmonics distortion 2 - Facility to Measure voltage and current unbalance Available - 2/5 Facility to Measure inrush current Available - Facility to Measure flicker Not-Available - DISPLAY Display type LCD Backlit - Display Mode Waveform | - | - | - |
| Meter Reading | - | - | - |
| Bar graph | - | - | - |
| Vector | - | - | - |
| digital reading - GENERAL FEATURES Facility to Measure RMS Voltage Available - Facility to Measure RMS Current Available - Facility to Measure Active | - | - | - |
| Reactive and Apparent Power Available - Facility to Measure Active | - | - | - |
| Reactive and Apparent Energy Available - GENERIC Data transfer software provided for analysis on PC Yes - Provision for external SD Card yes - Interface USB - Internal Memory (GB) 4 - Weight of the analyser 1.5 - other features THREE PHASE POWER QUALITY ANALYZER - POWER SOURCE/BATTERY Power Supply Battery operated | - | - | - |
| 230 V AC +/- 10% | - | - | - |
| 50Hz - If battery operated | - | - | - |
| chemistry of the rechargeable battery lithium ion - Voltage of rechargeable Battery 10.8 - capacity of rechargeable battery (milli AH) 2400 - Suitable charger adaptor provided yes - Battery backup (hours) 8 - OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Temperature 50 - 3/5 Operating Humidity (%) 90 - ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser BC430 Power Adapter | - | - | - |
| International plug adapter set | - | - | - |
| BP290 (Single capacity Li-ion battery) 28 Wh (8 hours or more) | - | - | - |
| TLS430 Test lead and Alligator clip set | - | - | - |
| WC100 color coding clips and regional decals | - | - | - |
| i430flex-TF | - | - | - |
| 24 inch (61 cm) length | - | - | - |
| 4 flexible current probes | - | - | - |
| 8 GB SD card | - | - | - |
| Power Log on CD (includes operator manuals in PDF format) USB cable A - Mini B | - | - | - |
| C1740 Soft Case - SAFETY Compliance to IEC 61000-4-30 Yes - Category of safety rating Category IV 600 V of IEC 61010 - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes - conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes - Availability of Test Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Yes - Test Report Number FLUKE/2018/5632456 - 4/5 and date DTD. 15.03.2018 Name and address of the Lab FLUKE CORPORATION | - | - | - |
| USA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Snehil Srivastav 403711 | - | - | - |
| Naval Armament Depot Goa Chicalim P O Vasco- da- Gama 1 20 Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 10.00 Duration of ePBG required (Months). 14 | - | - | - |
Exempted
20 Jul 2018
6 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_302341.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .