Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
24 Jan 2024, 12:00 pmClosed
EE ETD Banda
220 KV substation Tindwari Road Banda
Electrical Work
2023_UPTCL_875131_1
T-118/ETDB/2023-24
Open Tender
Electrical Works
Lump-sum
90 days
Banda
Having experiance to do similar work in UPPTCL
2 documents required · 2 mandatory
₹1,180
EE ETD Banda
₹20,000
27 Jan 2024
29 Dec 2023
27 Jan 2024
29 Dec 2023
24 Jan 2024
29 Dec 2023
29 Dec 2023 - 24 Jan 2024
Amount
Details of Work.
Supply of Material
TOWERS & ACCESSORIES
Number Plate in size 165 mm x 150 mm duly made of 16 SWG M.S. Sheet with letter and Numerals in enameled Red Colour on White colour enameled background indicating anem of Transmission line in Short ( In English letter of size 35 mm height ) and tower no. (In English letter of size 65 mm height) as per requirement and with provision of 2 no. holes for fixing along with 16 mm x 40 mm bolts. Nuts & washers.
Danger Plate in size of 380 mm x 250 mm duly made of 16 SWG M.S. Sheet Written " Danger 'in English letter of size 35 mm height in Hindi letter of size 45 mm height,"132000 VOLT" in English letter of size 30 mm height and indicating "Sign of Danger" in size of 70 mm x 80 mm all shown symmetrically in enameled Red Colour on white colour enameled background and provision of 2 nos. holes for fixing along with 16 mm x 40 bolts, nuts and washers.
Phase Plate in Sets of Red, Yellow & Blue Colour Circular Disc (Both sides enameled) of dia 100 mm duly made of 16 SWG Sheet with provision of 01 No. Hole for fixing along with 16 mm x 40 mm Bolt, Nut & Washer
Supply of Compression type Single Tension Fitting Assembly suitable for ACSR Zebra Conductor consisting of Compression type (Outer Sleeve duly made of Aluminium Alloy & Inner Sleeve duly made of HDG Forged Steel) Dead End Clamp with Jumper Terminal (Cone) and HDG Steel Anchor Shackle, Ball Clevis (HH type), Socket Clevis (HH type), Line side Arcing Horn, Tower side Arcing Horn complete with Split Pin, G.I. Bolts, Nuts, Plain & Spring Washers etc. as per Drawing / Sample.
Supply of 4R Stock Bridge type Vibration Damper suitable for ACSR Zebra Conductor consisting of High Strength Aluminium Alloy Clamp, High Strength Steel Strands Messenger Cable, HDG Cast Iron Damper Mass, HDG Fasteners etc. as per Drawing / Sample.
Supply of Pipe type Earthing Equipment consisting of 32 mm dia., 3050 mm Long heavy duty Perforated ‘C’ class G.I. Pipe with 50 mm x 6 mm size 4750 mm Long Galvanized Steel Flat and 2 No. 12 mm x 40 mm size G.I. Bolts with Nuts & Washers.
Supply of 160 KN Porcelian Insulator of standard make.
Supply of Earthwire and accessories
Tension Clamp
VIB Damper
Copper Bond
Work Associated for Diversion of 220 KV Pahadi-Rewa Road-Ist Line
Survey Icluding preparation of schedule of materials,marking of locations(Route length),GPS Survey of line with coordinates of each tower (The length of line shall be authenticated by GPS survey)
Check survey
Soil investigation
Excavation of Foundation Pits for 220 KV Towers / Gantries including all Earth Work, Back filling, Levelling etc.
Normal Soil
Hard rock
Setting of Stubs & Templates of 220 KV D.C. KPTL design tower and Setting of Foundation Bolts but excluding the Cost of Concerting & Excavation
Concreting of Foundations using M15 Grade Cement, Concrete, Coarse Sand mixture in the Ratio of 1:2:4 with 20 mm Stone Metal for Towers & Gantries including Cost of Materials, De-Watering, Shoring, Shuttering, Framing, Curing etc.
Installation of Steel Reinforcement Bars in R.C.C. Foundation for Towers & Gantries including Cost of Steel Reinforcement Bars with due Cutting, Bending, Binding, Placing etc.
Erection of Super Structures of 220KV Towers, their Extensions wherever required and Gantries including all Work above Ground Level with Proper Fixing & Tightening of all Tower Parts including Fitting of Danger Plate, Phase Plate, Number Plate, Bird Guard, Hanger etc. but excluding the Hoisting of Disc Insulator Strings / Polymer Insulator Strings, Conductor & Earth Wire Hardware Fittings etc.
Laying, Stringing, Tensioning, Clamping of Earthwire including Fixing of Tension Fittings, Suspension Fittings, Vibration Dampers, Copper Bonds etc. of 220 KV Pahadi-Rewa Road Line
Laying, Stringing, Tensioning, Clamping of ACSR Zebra Conductor including Hoisting of Tension / Suspension Disc Insulator Strings / PolymerInsulator Strings, Single Tension Fittings, Single Suspension Fittings, Vibration Dampers etc.
Tack Welding of all the Bolts - Nuts upto 2nd Section of the Towers and upto 5 Meter Height of Gantries from Ground Level with 3 Tacks of 10 mm thickness, then Applying of Zinc Rich Aluminium Paint on the affected Surfaces.
Earthing Work including Earth Work (Excavation of Earth & Back Filling) for Pipe type Earthing of new Section Towers & Gantries including Cost of Coke, Salt etc.
Dismentling of ACSR Zebra Conductor of existing 220 KV Banda-Rewa Road-Ist
Safe Loading, Carriage from 220 KV S/S Pahadi, Line material & Conductor to work side if required.
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
RAGHAVI ENTERPRISES
MS RK ERACTORS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .