Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC HOUSE NO 142 GALI NO 07 PREM VIHAR NANGLI SAKRAWATI NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹26.5 L+₹5.8 L (28.2%)Rejected-Finance H NO 1237 PANA PAPOSIAN NARELA NORTH WEST DELHI NEW DELHI 110 040 | NEW DELHI | NORTH WEST DELHI | DELHI | 110040 | L2 | Rejected-Finance other than L1 | |
| 3 | L3₹28.9 L+₹8.2 L (39.8%)Rejected-Finance | L3 | Rejected-Finance other than L1 | |
| 4 | L4₹29.0 L+₹8.3 L (40.2%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L4 | Rejected-Finance other than L1 | |
| 5 | L5₹29.9 L+₹9.2 L (44.6%)Rejected-Finance MIG FLAT 6D POCKET I SECTOR 10 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L5 | Rejected-Finance other than L1 |
| Sl No | Description | Qty | Unit | verma enterprises L4 | A B K Enterprises L3 | M/s Sohanil Construction L7 | M/S HARINDER SINGH L2 | Elmek Engineers L5 | S K ENGINEERS AND CONTRACTOR L1 | J V ENGINEERS / JAI SINGH L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed. | 309.67 | Cum | 189 ₹58,528.01 | 100 ₹30,967.2 | 99 ₹30,657.53 | 55 ₹17,031.96 Lowest | 120 ₹37,160.64 | 99 ₹30,657.53 | 125 ₹38,709 |
| 2.00 | Excavation in trenches exceeding 1.5 M wide and exceeding 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed. | 0.47 | Cum | 299 ₹142.03 | 100 ₹47.5 | 65 ₹30.88 | 55 ₹26.13 Lowest | 240 ₹114 | 220 ₹104.5 | 99 ₹47.03 |
| 3.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed. | 214.71 | Cum | 29 ₹6,226.47 | 30 ₹6,441.18 | 5 ₹1,073.53 Lowest | 55 ₹11,808.83 | 30 ₹6,441.18 | 21 ₹4,508.83 | 9 ₹1,932.35 |
| 4.00 | Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc1.5 M above the starting point | 94.97 | Cum | 29 ₹2,754.01 | 20 ₹1,899.32 | 15 ₹1,424.49 Lowest | 55 ₹5,223.13 | 30 ₹2,848.98 | 21 ₹1,994.29 | 20 ₹1,899.32 |
| 5.00 | Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness only measured and paid | 55.74 | Cum | 499 ₹27,814.76 | 250 ₹13,935.25 | 289 ₹16,109.15 | 333 ₹18,561.75 | 600 ₹33,444.6 | 220 ₹12,263.02 Lowest | 295 ₹16,443.6 |
| 6.00 | Supplying and laying reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx l80mm x 40mm to the length of cable complete all as specified and directed. | 2,913 | Each | 29 ₹84,477 | 30 ₹87,390 | 12 ₹34,956 | 5 ₹14,565 Lowest | 30 ₹87,390 | 16 ₹46,608 | 15 ₹43,695 |
| 7.00S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :- | ||||||||||
| 7.01 | (a) 80 mm dia | 20 | RM | 599 ₹11,980 | 350 ₹7,000 | 395 ₹7,900 | 343 ₹6,860 | 600 ₹12,000 | 330 ₹6,600 Lowest | 399 ₹7,980 |
| 7.02 | (b) 100 mm dia | 18 | RM | 699 ₹12,582 | 450 ₹8,100 | 455 ₹8,190 | 433 ₹7,794 | 800 ₹14,400 | 360 ₹6,480 Lowest | 449 ₹8,082 |
| 8.00 | M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation. | 2 | Cum | 2,999 ₹5,998 | 2,500 ₹5,000 | 2,455 ₹4,910 | 3,222 ₹6,444 | 3,500 ₹7,000 | 2,200 ₹4,400 Lowest | 2,999 ₹5,998 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Jan 2026, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI
REPAIR MAINT OF OVERHEAD LINES, TRANSFORMER, ELECTRIC POLES, VCBs, RMUs AND CONNECTED ACCESSORIES AT KHANPUR ARMY CAMP, MANESAR ARMY CAMP, DUNDAHERA MIL STN AND INDU BINOLA UNIVERSITY UNDER AGE EM OF GE (SOUTH) DELHI CANTT-10
2025_MES_745347_1
CWE-ND/52/2025-26
Open Tender
Civil Works - Others
Item Rate
120 days
DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) DELHI CANTT
₹80,000
18 Mar 2026
19 Dec 2025
9 Jan 2026
19 Dec 2025
7 Jan 2026
2 Jan 2026
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed.
Excavation in trenches exceeding 1.5 M wide and exceeding 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.
Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc1.5 M above the starting point
Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness only measured and paid
Supplying and laying reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx l80mm x 40mm to the length of cable complete all as specified and directed.
(a) 80 mm dia
(b) 100 mm dia
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work all as directed.
M & L for PCC 1:2:4 type B1 using 40 mm graded stone aggregate including use and waste of form work for pole coping/ any description all as directed.
Disnmantling of existing old unserviceable earth wire and gradle guard of any size form the position, material and labour for providing new GI wire 4 mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, all as directed.
M & L in repairs for Galvanised Stay wire of size 7/4 mm incl dismantling old wire all as directed.
S & F in repairs Pin type porcelain vitreous,brown or white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as directed.
S & F in repairs incl testing of swing out explusion fuse isolated assembly with fuse carrier out door type 11 KV supply 50 Amp ( DO Fuse ) incl mounting bracket & post insulator comlete all as directed. (Make : Atlas/GEC/Pactil)
S & F in repairs cable end jointing kit for 11KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable end jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
M & L for painting of HT/LT VCB,Panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun all as directed.
Supply & Lay , testing and commissioning XLPE cable in replacement , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete
Ditto all as per item No 34 here in before but of cable size 3 core 120 sqmm all as directed.
(a) Male contact/moving Contact Blade
(b) Female contact/Fix Contact Jaw
(c) MS jumper carrier
(d) Back Connector plate
S & F in repairs of existing 11 KV electric meter incl testing of metering & protection current transformer Oil filled out door type of 11 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT all as directed. Note : Calibration & testing record for the sane shoud be submitted by the contractor to Engg in charge.
M & L for Cutting and trimming of tree branches of girth 25 mm to 75 mm to 3 mtr all around of any size which is obstructing illumination of street light and touching LT / HT Over head line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely)
M & L for preparation of old surface, cleaning the surface of the Steel pole (HT) 11 Mtr long pole structures above the ground level incl coping area and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and derected by engr-in charge
M&L for alternative arrangement by hiring, transportation of transformer of capacity up to 400 KVA in place of unserviceable transformer on hire basis for 15 days/upto replacing of defective transformer including, installation, connecting and testing of transformer and return back after installation of repaired transformer complete all as specified and directed.Notes:- (i) Contractor must arrange hired transformer including transportation and installation at site immediately after receipt of verbal/telephonic/written complaint from JE/Engr-in-Charge within 1 day. Any delay beyond 1 day post receipt of complaint shall be penalized @ Rs 3500/- per day and shall be recovered from next due RAR.(ii) Repairing of transformer must be completed within 15 days after receipt of verbal/ telephonic/ written complaint from JE/Engr-in-Charge. In case of any delay, no extra claim will be entertained towards hiring charges beyond 15 days and the contractor shall not be allowed to shift the hired transformer until replaced by repaired transformer. In case of any kind of fault / defect occurred in hired transformer, the contractor shall have to arrange further replacement without any additional cost and shall repair the defect from his own expenses. (iii) Contractor should check the available infrastructure and to be sure regarding safety of hired transformer before installation. The rate quoted is deemed to be including transportation cost, earthing lead etc.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT 33 KV transformer/HT 11 KV AVR /Distribution transformer 100 to 600 KVA or for replacement complete including removing of old unservicable transformer oil all as specified and directed. Note : Necessary documents should be submitted by the contractor to Engr In Chrge.
M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/AVR/CT/PT units all as directed. (Note : The contractor shall change the
filter assy before starting the filtration of transformer / AVR of capacity 600 KVA and more capacities in presence of Engr In charge) Note : Necessary documents should be submitted by the contractor to Engr In Chrge.
All as per item No 53 above but LT side.
M & L for painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer up to 400 KVA (Indoor/outdoor type).
M&L for replacement off load tap changer for distribution transformer of any make and capacity upto 400 KVA
Disconnecting HT supply from 11 KV , 630 Amps RMU , 2/3/4 way and servicing and overhauling of RMU , checking of tripping mechanism , greasing of moving contacts , cleaning of carbon from main contacts , checking of spring tension ,Checking of loosened bolts and nuts, checking of loosened connections, rust, damaged lead wires, checking of spring charging motor , Improvement of resistance of CTs , PT, epoxy insulator and epoxy body by applying post heated varnish complete all as directed and testing on load
S&F in repairs operating mechanism (2PA Mechanism W/O hex Rod) for 11 KV , 630 Amps RMU , 2/3/4 way complete all as directed at site by Engr-in -charge
Supply and fixing in repairs the following spares for outdoor/indoor RMU/VCB of 11 KV 630/400 A 25 KA 250MVA as approved by GE agianst above sl no:-
i) Closing coil 24/30V DC
ii) Tripping coil 24/30V DC
iii) Antipumping device 24/30V DC
iv) 11 KV porcelain bushing for VCB Top
v) 11 KV porcelain bushing for VCB bottom
vi) Connector strip 16 way
vii) Earth Fault and over current relay of L & T Model No MC61A 24-110V
viii) Digital type power factor indicator meter
ix) Digital type Voltmeter / Ammeter 96 x 96 mm size
x) LED type indicator lamp assembly
xi) Vacuum Interrupter for indoor VCB
xii) spout incoming side
xiii) spout outgoing side
xiv) Epoxy insulators bushings for incoming / out going cables / bus bar suppors as per existng size of VCBs
xv) Insulated Copper bus bar of existing size and thickness for VCBs
xvi) Gear system assembly complete with handle for charging / discharging of VCBs
xvii) Spring charging motor for VCBs
Ditto all as per item No 102 here in before but 30 to 50 A capacity
Re- Stringing only existing HT 11/33 KV / LT OH line / Jumpers including dismantling of existing old binding wire for tightneing complete. Note: (a) Restringing of each wire shall be measured as in RM. (b) Supply only binding wire shall be measured and paid separately.
S & F in repairs MS cross arms channel, bracing, support, clamps, chuquered plates etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum/ black paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as directed.
ith copper earth plate 60x60cmx3.15 mm thick electrode and 20x3mm copper strip as earthing lead burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and CI cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc and connected to earthing test point all as specified or directed and testing complete all as specified.
Supply, Installation,testing commissioning of following items/spares in the existing panel of automatic power factor improvement (outdoor) capacitor bank having aggregate capacity 100 KVAR to 250 KVAR (As per site requirment) in different stage with microprocessor along with factory made type panel board including taking down old/unservicable following parts complete all as specified and directed.
Power factor corrector relay 8 to 12 stage
Capacitor duty contactor for 25 KVAR
Capacitor duty contactor for 20 KVAR
Capacitor duty contactor for 15 KVAR
Capacitor duty contactor for 10 KVAR
Capacitor duty contactor for 5 KVAR
ON-OFF push button
Aux Contactor 4 No + 4 NC
Indicating lamp ON-OFF
Power factor 25 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Power factor 20 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Power factor 15 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor
Digital Ammeter 0-400 A with VSS & CT
M&L for Servicing of complete APFC panel upto 250 KVAR including cleaning of the terminal and coil and incoming & outgoing connections fixed with high tensile nut and bolts fixed and associated wiring of the auxiliary blocks and Manual functional testing of the Panel after servicing by directly giving command from the terminal blocks with all required tools, manpower and Assembling the panel after servicing , closing and mounting of all components. Cleaning of the Panel with Vacuum cleaner/blower ensuring that no control and power wiring is disturbed during the work complete all as specified and directed by Engr-in-charge.
Taking out old UNSV and supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed :- (Make: Havells/Polycab/Glostar/KEI)
(g) 70 Sqmm 3.5 Core.
(h) 95 Sqmm 3.5 Core.
(j) 120 Sqmm 3.5 Core.
(k) 150 Sqmm 3.5 Core.
Disconnect old UNSV HT 11 KV 2 pole ( RCC pole) structure and Supply and errect and functioning of 2 pole structure on 11 meter steel tubular pole consisting of pole with anti-climbing device, PCC foundation & cross arms, etc for one incoming and two outgoing complete all as specified and directed by Engr-in-Charge.(Note: Relevant items i.e PCC, Cable, cross arms, cable and earth work wiil be measured separately)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.61 MB
SCHOFCREDIT.pdf
Tender Documents • 0.19 MB
tender52.pdf
Tender Documents • 1.61 MB
BOQ_834608.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .