Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
Closing Date
28 Oct 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CPO-STEEL
This Tender is for SUPPLY AND ERECTION FOR CANOPY AT RETAIL OUTLETS UNDER NWFZ
2500023280-HD-09050
5100023280
Open Tender
Two Bid
Unknown (Unspecified Location)
28 Oct 2025
7 Oct 2025
28 Oct 2025
28 Oct 2025
7 Oct 2025 - 20 Oct 2025
14 Oct 2025
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | STRUCTURAL STEEL FOR | STRUCTURAL STEEL FOR — DESCRIPTION => Supplying, transporting, fabricating, erecting inposition in position of Pre- fabricated steel structures at all elevations for Canopy using structural steel sections ISMB/ISMC/ISA conforming to IS:2062 and IS 226 , including cutting, weldingor bolting, supply of bolts/nuts/washers etc., complete as per drawingsincluding surface preparation and applying one coat of Zinc PhosphatePrimer before erection, one coat after erection and two coats ofsynthetic enamel paint as per specification after erection and allmaterials and labour complete. ( No welding is permitted at site). Therate quoted shall include cost of bolts, nuts, washers, welding andelectrodes and any other consumables required for completing the work.Nut bolts shall not be considered for payment.Theoretical wight of steelsections shall be considered for payment..(.(No measurement shall betaken for nut,bolt,washer splice plate <(>&<)> gusset plate) | - | Metric ton |
| 2 | ROOFING CLIPPON | ROOFING CLIPPON — DESCRIPTION => Supply and fixing Clippon Roofing System:Roofing base material should be of cold rolled steel of 0.55 mm thick and conform to ASTM:A 446 having yield stress of 275 MPA . The coating should be Aluminum and Zinc alloy comprising 55% Al, 43.5 Zinc & 1.5 % Silicon, as per ASTM :A 792 . The coating mass should not be less than 150 Gms per SqM (total of both sides). For, bare galvalume, TCT should not be less than 0.55 mm. Sheets shall have approved side laps with top sheets facing away from the prevailing weather. Necessary profiled filler box should be provided at higher level of roof sheeting and at valley gutter to ensure water tightness in the profiled gaps . The fixing of roofing shall be done in such a manner that the roof is not drilled / punctured for fixing with the purlins .Refer to the approved makes given in the Attachment. Flashings, Cappings and trims: These shall be formed out of same substrates as that of the roofing sheets and shall be supplied in standard lengths of 2.5 M in the required shapes and girths and fixed by means of hex-head mechanically galvanized stitching screws. Silicon sealant non-hardening neutral cure type shall be applied at all laps to avoid water seepage. | - | square meter |
| 3 | FALSE CEILING | FALSE CEILING — DESCRIPTION => Providing & fixing false ceiling system of Trac 150 F exterior grade or approved equivalent of 0.5mm thick galvanised steel with stove enameled coil coated finish inter locking ceiling panels, carriers, suspension system and edge closure as per the following specification. Supplying and installation of exterior grade 150 F ceiling system comprising of 150 mm x 17 mm deep panels roll formed out of 0.5 mm galvanised steel with stove enameled coil coated finish. The panels shall be pre-treated and coil coated on one side in manufacturers standard colour shades as approved by the Architect/ Engineer in charge. The rear side of the panel shall be given a coat of primer and a wash coat while the finished side shall be given a coat of primer and finish colour coat in polyster paint for a min. dry film thickness of 20 microns, fixed on to the roll formed carriers 34.5 mm x 488 mm deep out of 6 mm thick Galvanised steed with prongs to hold panels in the module of 150 mm at maximum 1.2 mts. C/C. The carriers to be suspended from roof truss by rigid suspension angles as per manufacturer's recommendation. Panels shall be supplied in custom length upto maximum of 5 mts. Job also includes providing ceiling flashing using factory formed 0.5 mm thick Polyster coated galvanised steel material. Rate shall be including providing flashing to cover gap if any between illuminated banding and false ceiling. | - | square meter |
| 4 | GI FASCIA | GI FASCIA — DESCRIPTION => Supplying and fixing 20 SWG GI sheet facia including painting with one coat of zinc chromate primer and two coats of 1 st quality synthetic enamel paint on front side . Necessary facia framework for fastening the sheet to the canopy securely shall be paid separately. | - | square meter |
| 5 | AL GUTTER | AL GUTTER — DESCRIPTION => Providing and fixing 2 mm thick Aluminum Sheet Gutters of required shape in slope with 40 mm x 3 mm MS. Brackets at 1000 mm maximum spacing and 8 mm dia G.I. J or L hooks, boltsand nuts, GI Limpet and bitumen washers, providing nut bolt joint , sealing the joints with silicon sealant testing the gutter for leakage by filling water etc. Complete.(Refer attached Drawing .For allowable tolerance refer to IS codes | - | meter |
| 6 | UPVC GUTTER 450mm Wide | UPVC GUTTER 450mm Wide — DESCRIPTION => Providing and fixing 3 mm thick UPVC Gutters The gutters shall be installed according to the provided drawings, ensuring proper alignment, slope, and secure attachment to the supporting structure. All joints between gutter sections must be sealed using silicone sealant that is compatible with uPVC materials. It is crucial that no bolting or hot work methods are used for joining the sections of the gutter. The use of such methods is strictly prohibited to maintain the integrity of the system. Support for the gutter sections shall be provided using appropriate mounting brackets or supports, ensuring that the system remains secure and functional. These supports must be installed with the use of bolting. Once the installation is complete, the entire system must undergo a leakage test. This will involve filling the gutter system with water to ensure that no leakage occurs from any of the joints or connections. The testing procedure should confirm the system's reliability and functionality, ensuring that there are no visible signs of leakage under normal conditions. | - | meter |
| 7 | LED FIXTURE 80 W | LED FIXTURE 80 W — DESCRIPTION => 80 W LED Fitting as mentioned in IS standards IS 16101 to 16107::Supply and fixing of 80 W LED housed by Single piece Pressure Die Cast Aluminum body, recess mountable fitting with guaranteed burning hours of 50000 .Make Philips/Havells/Bajaj/Wipro/Osram/Crompton/GE/Bever Innovations. IP Protection of minimum IP 65 and above, suitable for canopy lighting at retail outlets (Petrol station) .The bidder should submit copy of certified photometric report as per IESNA LM-79(Approved method for the Electrical and Photometric Measurements of Solid-State Lighting Products) from a UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC. A minimum 3 years warranty from manufacturing defects for the luminaire by manufacturer.i) With high lumen efficacy LEDs from CREE, Seoul Semi-Conductor, Lumiled Philips, Osram, Nichia (Japan), Tridonic (Austria), GE and Bridgelux . Efficiency of more than 90 lumens per watt . LEDs used in the fixture should be from the same bin and certified as per LM-80 (IESNA: Approved Method for Measuring Lumen Maintenance of LED Light Sources and LED lumen depreciation time to L70 based on LM- 80 data). by any UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC.ii) Bottom open able for easy maintenance.iii)High Quality Polycarbonate Opal Diffuser for Optimum uniformity and Glare free light output.iv) General electrical protection against High Voltage and Surges up to3 KVv) Power factor > 0.95vi) Range allowed for total system wattage 80 W with +2W or -2W vii) Driver Operating Voltage Range: 140 V- 270 V viii) Operating Temperature 0 to +45 Deg Centigrade viii) CRI more than 70 ix) Colour temperature5650K±500K (to be mentioned in LM 79 certificate) x)Wide beam angle xi)Luminaire Performance Complies to IS10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529, ROHS | - | Each |
| 8 | LINEAR LED FIXTURE 80 W | LINEAR LED FIXTURE 80 W — DESCRIPTION => 80 W LED Fitting as mentioned in IS standards IS 10322 Part 5/Sect 2: 1967:Supply and fixing of 80 W LED housed by Extruded Aluminium Alloy (1.1 mm Thickness minimum), Aluminium end cap shall be Die-cast & with Opal white Polycarbonate diffuser (1.2 mm Thickness minimum ) body lenth 2400MM +/- 15mm, recess mountable fitting with guaranteed burning hours of 50000 .Make Philips/Havells/Bajaj/Wipro/INNOTRONIX/ALUDECOR/NINJAS. IP Protection of minimum IP 67 and above, suitable for canopy lighting at retail outlets (Petrol station) .The bidder should submit copy of certified photometric report as per IESNA LM-79(Approved method for the Electrical and Photometric Measurements of Solid-State Lighting Products) from a UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC. A minimum 5 years warranty from manufacturing defects for the luminaire by manufacturer.i) With high lumen efficacy LEDs from Nichia / Cree / Osram / Philips (Lumiled) / Seoul/Bridgelux/Samsung/ Tridonic (Austria), GE and Bridgelux . Efficiency of more than 100 lumens per watt . LEDs used in the fixture should be from the same bin and certified as per LM-80 (IESNA: Approved Method for Measuring Lumen Maintenance of LED Light Sources and LED lumen depreciation time to L70 based on LM- 80 data). by any UL/ ERTL /ERDA or any NABL accredited laboratory to validate the photometric claims as & when asked by HPC.ii) Bottom open able for easy maintenance.iii)High Quality Polycarbonate Opal Diffuser for Optimum uniformity and Glare free light output.iv) General electrical protection against High Voltage and Surges up to3 KVv) Power factor > 0.95vi) Range allowed for total system wattage 80 W with +2W or -2W vii) Driver Operating Voltage Range: 140 V- 270 V viii) Operating Temperature -10 to +50 Deg Centigrade viii) CRI more than 70 ix) Colour temperature5700K(+350) (to be mentioned in LM 79 certificate) x)Wide beam anglexi)Highly Efficient Silicon Encapsulated IP 67 Driver > 85% for wattage <= 40W > 87% for wattage > 40W Single driver for each fitting . Detailed Specification sheet attached. Performance Complies to IS10322 (Part 5/Sec 3) & IEC 60598-1,IEC 60529, ROHS | - | Each |
| 9 | 4CX2.5SQMM COPPER CABLE | 4CX2.5SQMM COPPER CABLE — DESCRIPTION => Supply and laying following size PVC insulated, sheathed, armoured cable of approved make conforming to IS 1554:Part 1:1988 4CX2.5SQMM COPPER CABLE | - | meter |
| 10 | 4CX2.5 SQMM END | 4CX2.5 SQMM END — DESCRIPTION => END TERMINATION End termination of following cable with double compression NFLP gland and crimping sockets 4CX2.5 SQMM END TERMINATION | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2500023280-HD-09050.pdf
TENDER_DOCUMENT • 39.75 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .