Loading…
Loading…
Tender Value
₹2.8 Cr
EMD Value
₹2.9 L
Closing Date
15 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECTRICAL
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three nancial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared / audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-15 (Annexure-VIB), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant / Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderers must submit the copy of valid Electrical contractor license along with their offer. Offer shall rejected be summarily, if tenderer does not have valid Electrical contractor license on the name of an individual / Proprietor / Partner / firm issued by the State / Central government.
T h e tenderer must have successfully completed any o f t h e following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than t h e amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- "Design, supply, erection testing & commissioning of 50Hz, single phase 25KV AC OHE". (Ref: Pr. CEE/NR's Letter No. 181-Elect/TRD/189/Pt.II, dated 29.07.2021)
34 conditions · 16 needing a document upload
Bid Security: Tenderer (s) may please note that offers received without Bid Security either in cash through e-payment gateway or as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents (as per Annexure- 21) valid for a period of 90 days beyond the bid validity period, will be considered as incomplete & invalid offer and for which contractor shall have no claim on Railway.
Following documents shall be submitted by the tenderer: (A)SOLE PROPRIETOR SHIP FIRM: (i) Undertaking that he is not blacklisted / debarred by Rlys/other Ministry/Deptt of Govt of India from participation in tender on date of bid opening, either in individual capacity or as a member of partnership firm or JV in which he was/is a partner/member. Concealment/wrong information in regard to above shall make the contract liable for determination under Clause62 of GCC. (B) HUF: a. Copy of notarized affidavit on Stamp Paper declaring that he who is submitting tender on behalf of HUF is in position of Karta of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. b. Undertaking that the HUF is not blacklisted or debarred by Rlys/any other Ministry/Deptt of Govt of India, either in individual capacity or as a member of partnership firm or JV in which HUF was/is a partner/member. (C) PARTNERSHIP FIRM: (i) Notarized copy of partnership deed. (ii)Notarized or registered copy of Power of Attorney in favor of the individual to tender for the work, sign agreement etc and create liability against the firm. (iii)Undertaking by all partners of partnership firm that they are not blacklisted/debarred by Rlys/any other Ministry/Deptt of Govt of India from participation in tenders/contracts as on date of bid opening, either in their individual capacity or in any firm in which they were/are partners. (iv)All details of Firm must be provided in Annexure- 10. (v)Complete details as perAnnexure-17B. (D) JOINT VENTURE (JV): APPLICABLE ONLY FOR WORKS COSTING MORE THAN Rs.10.00 Cr. Not applicable for this tender. (E) Company registered under Companies Act-2013: Tenderer must submit/upload tender along with following documents: (i) Copies of MOA (Memorandum of Association)/AOA (Articles of Association) of company. (ii) Copy of Certificate of Incorporation (iii) Copy of Authorization/Power of Attorney issued by the Company (backed by Resolution of Board of Directors) in favor of the individual to sign tender on behalf of company and create liability against the company. (iv) Undertaking that Company is not blacklisted/debarred by Rlys/any other Ministry/Deptt of Govt of India from participation in tender on the date of opening of bids, either in individual capacity or as a member of the partnership firm or JV in which the Company was/is a partner/member. (F) LLP (Limited Liability Partnership) Firm under LLP Act-2008: Tenderer shall submit along with tender: (i) Copy of LLP Agreement (ii) Copy of Certificate of Incorporation (iii)Copy of Power of Attorney/Authorization issued by LLP in favor of individual to sign tender on behalf of LLP and create liability against LLP. (iv) Undertaking that LLP is not blacklisted/debarred by Rlys/any other Ministry/Deptt of Govt of India from participation in tender on the date of bid opening, either in individual capacity or as a member of JV in which the LLP was/is a member. (G) Registered Society & Registered Trust: Tenderer shall submit: (i) Copy of Certificate of Registration. (ii) copy of Deed of Formation. (iii) Copy of Power of Attorney in favor of individual to sign tender documents and create liability against the Society/Trust. (iv) copy of Rules & Regulations of Society. Note: The offers received without proper Power of Attorney shall be considered in-completed and rejected summarily.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall study the Indian Railway General Conditions of Contract Regulations for Tenders & Contracts (GCC)- April'2022 or latest along with tender documents before submission of the tender.
The tenderer shall submit all the requisite documents along with tender offer. Tender offer without these documents shall not be considered. "No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void". To assist in the examination, evaluation and comparison of offers received, the Railway may at their discretion, ask any Tenderer for clarification on attached document with their Tender. The request for clarification and the response shall be in writing or by FAX but no change in the price or substance of the Tender shall be sought, offered or permitted. In case no credentials enclosed or statement to that effect is mentioned, the identity of working contractor of division shall be taken as fresh.
Period of Completion : The entire work is required to be completed in all respect within specified period from the date of issue of the letter of acceptance. The contractor shall maintained steady and regular progress to the satisfaction of the Sr.DEE/TR/JAT or his authorized representative and to ensure that the work will be completed in all respect within the stipulated time, failing which action may be taken by the Railway Administration in terms of clause 17 and clause 62 of the General Conditions of contract (GCC)- April'2022 or latest.
Non-compliance with any of the conditions set forth therein above is liable to result in the tender being rejected. NOTE: (i) Copy of GCC of April'2022 is uploaded with NIT as ready reference of Tenderers. (ii) The offers received without proper Power of Attorney shall be considered in-completed and rejected summarily.
The rates quoted by the bidder are to be inclusive of all charges and all taxes levied by the Union of India, State Government and Local Bodies etc., from time to time including Surcharge except GST. However, GST @ 18% or applicable as per Extant Rules shall be paid extra as per Schedule-04 on all items of Schedule- 01, 02 & 03.
Night working : Though normally no work is carried out in night i.e., from sun set to sun rise the progress of the work if not coming up to the time schedule laid down in clause above the Engineer-in-charge can order for night working by the contractor and the contractor shall make all arrangements for adequate lighting and safety precautions etc., for night working.
Contractors will have to upload details of their LOAs, engaged workmen, wage payment details, PF/ESI details, bonus details etc., on website www.shramikkalyan.indianrailways.gov.in on monthly basis. (Railway Board's letter No. 2018/CE-I/CT/4 dated 17.10.2018)
Guarantee : The tenderer shall guarantee the equipments/installations for satisfactory performance for a period of 12 months or mentioned in special condition / technical specifications or as mentioned by the manufacturer, which ever in higher from the date of commissioning against any defect. The contractor should promptly attend complaint and replace/repair the defective equipments/parts free of cost promptly and satisfactorily. The equipments/parts so replaced by the contractor, shall be further guaranteed for a period of 12 months or mentioned in special condition / technical specifications or as mentioned by the manufacturer for satisfactory service from the date of such replacement.
The tenderers shall keep their offer open for 60 days (Sixty days).
The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the contractor has complete the work in all respects satisfactorily. The Security Deposit shall also be released based on 'Completion Certificate' issued by Consignee / Engineer In- charge of the work to the contractor, submission of authentic documents that firm has paid GST as applicable by the extant rule and on completion of guarantee / warrantee period of ONE Year or as stipulated in Tender Documents.
Ambiguous and incomplete (i.e. not filling the rates or controversial rates and not attaching all the required documents) offer may be summarily rejected.
Any typographical error shall not be construed to be benefit of the contractor; in such cases the interpretation and decision of Sr. DEE/TR/JAT shall be final and binding upon the tenderer.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc are not allowed.
For verification of documents tenderer has to submit the details of issuing authority and organization like-Postal address, Name, Designation, Office phone number, Mobile no. and email ID of concerned person.
TRD work in c/w reliability improvement in Mirthal - Bhogpur Sirwal section in Jammu division.
764A-TRD-JAT-2025-26
764A-TRD-JAT-2025-26
Open
Works - General
12 Months
Jammu, Jammu And Kashmir
₹0
₹2.9 L
15 Apr 2026
23 Mar 2026
1 Apr 2026
224 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,19,79,555.78 | ||
| — | 25.00 | — | — | ||
| Preparation of drawing as per RDSO design for Over Head Equipment | — | — | — | 2,83,682.5 | |
| — | 275.00 | — | — | ||
| Supply of Concrete for foundation and plinth in other than hard & rocky soil | — | — | — | 18,53,373.5 | |
| — | 275.00 | — | — | ||
| Erection of Concrete for foundation and plinth in other than hard & rocky soil | — | — | — | 4,54,561.25 | |
| — | 36.00 | — | — | ||
| Supply of galvanized steel fabricated masts / other supporting structure | — | — | — | 47,93,041.8 | |
| — | 36.00 | — | — | ||
| Erection of galvanized steel fabricated masts / other supporting structure | — | — | — | 3,54,310.56 | |
| — | 18.80 | — | — | ||
| Supply of fabricated and galvanized steel work (SPS) other than mast with necessary components | — | — | — | 25,60,248.86 | |
| — | 18.80 | — | — | ||
| Erection of fabricated and galvanized steel work (SPS) other than mast with necessary components | — | — | — | 1,70,378.76 | |
| — | 96.00 | — | — | ||
| Supply of Single bracket assembly (without insulator) | — | — | — | 20,77,114.56 | |
| — | 96.00 | — | — | ||
| Erection of Single bracket assembly | — | — | — | 2,02,693.44 | |
| — | 96.00 | — | — | ||
| Supply of Stay and bracket tube Porcelain type insulators (CD 1050mm) for single bracket assembly | — | — | — | 10,28,926.08 | |
| — | 96.00 | — | — | ||
| Erection of insulators for single bracket assembly | — | — | — | 1,33,516.8 | |
| — | 1.50 | — | — | ||
| Supply of OHE with complete fitting (For Conventional type) without Contact & Catenary Wires as per explanatory Notes | — | — | — | 39,923.13 | |
| — | 1.50 | — | — | ||
| Erection of OHE with complete fitting (For Conventional type) without Contact & Catenary Wires as per explanatory Notes | — | — | — | 39,778.01 | |
| — | 20.00 | — | — | ||
| Supply of 9-Tonne Porcelain insulator (CD 1050mm) | — | — | — | 1,68,419 | |
| — | 20.00 | — | — | ||
| Erection of 9-Tonne insulator | — | — | — | 28,125.2 | |
| — | 14.00 | — | — | ||
| Supply of Section Insulator assembly including bar insulator assembly for conventional OHE | — | — | — | 7,69,770.68 | |
| — | 14.00 | — | — | ||
| Erection of Section Insulator assembly including bar insulator for conventional OHE | — | — | — | 47,129.74 | |
| — | 8.00 | — | — | ||
| Supply (without insulator) of 25KV Single Pole(SP) Isolator without earth contact assembly | — | — | — | 4,13,907.52 | |
| — | 8.00 | — | — | ||
| Erection of 25KV Single Pole(SP) Isolator without earth contact assembly | — | — | — | 36,081.44 | |
| — | 40.00 | — | — | ||
| Supply of 25KV post / pedestal insulators for isolators | — | — | — | 3,58,155.6 | |
| — | 40.00 | — | — | ||
| Erection of 25KV post / pedestal insulators for isolators | — | — | — | 15,324 | |
| — | 8.00 | — | — | ||
| Supply & erection of post and operating rod insulator | — | — | — | 1,60,900 | |
| — | 200.00 | — | — | ||
| Supply of copper bus bar 18mm | — | — | — | 2,78,066 | |
| — | 200.00 | — | — | ||
| Erection of copper bus bar 18mm | — | — | — | 24,586 | |
| — | 2000.00 | — | — | ||
| Manufacturing supply of Retro Reflective type structure Number plate as per RDSO drg. No.ETI / OHE / P / 7503 or latest along with all fixing arrangement. | — | — | — | 13,52,560 | |
| — | 2000.00 | — | — | ||
| Erection / Fixing of Retro Reflective type structure Number plate as per RDSO drg. No.ETI / OHE / P / 7503 or latest along with all fixing arrangement. | — | — | — | 1,70,260 | |
| — | 40.00 | — | — | ||
| Supply of material without insulators for termination of OHE conductor | — | — | — | 2,89,047.2 | |
| — | 40.00 | — | — | ||
| Erection of material for termination of OHE conductor | — | — | — | 40,722.4 | |
| — | 230.00 | — | — | ||
| Supply of Structure Bonds | — | — | — | 2,06,098.4 | |
| — | 230.00 | — | — | ||
| Erection of Structure Bonds | — | — | — | 51,014 | |
| — | 30.00 | — | — | ||
| Supply of Transverse (cross rail, inter-track, Z & special type) bonds | — | — | — | 31,528.2 | |
| — | 30.00 | — | — | ||
| Erection of Transverse (cross rail, inter-track, Z & special type) bonds | — | — | — | 4,551.9 | |
| — | 100.00 | — | — | ||
| Supply of Longitudinal bonds | — | — | — | 66,799 | |
| — | 100.00 | — | — | ||
| Erection of Longitudinal bonds | — | — | — | 14,179 | |
| — | 50.00 | — | — | ||
| Supply and erection of standard Galvanized wire bond in place of M S Flat bond at designated locations in theft prone areas | — | — | — | 78,465.5 | |
| — | 700.00 | — | — | ||
| Fabrication and supply of Structure Bond of MS Flat size 40X6mm duly painted alongwith fasteners for both leg of Portals (as per RDSO report No. TI/REPORT /PSI/2015/ 00104) | — | — | — | 11,96,426 | |
| — | 100.00 | — | — | ||
| Erection of bonds on platform area including drilling of holes in structure and rail including cutting of platform surface100mm x 500mm placing of bond and making good surface with PCC and providing cleats as per latest RDSO drawing | — | — | — | 2,53,533 | |
| — | 30.00 | — | — | ||
| Supply and fixing of cleat 02 Nos. for each structure Bond on platform wall with screw | — | — | — | 2,501.1 | |
| — | 30.00 | — | — | ||
| Platform cutting and covering with concrete according to Bond size | — | — | — | 8,932.2 | |
| — | 90.00 | — | — | ||
| Dismantling of Bracket Assembly | — | — | — | 1,46,321.1 | |
| — | 0.60 | — | — | ||
| Dismantling of fabricated steel other than mast | — | — | — | 9,477.46 | |
| — | 12.00 | Each Span | — | ||
| Raising / Restoration of OHE height as per OHE profile by Change of incumbrance / Re-droppering of span | — | — | — | 22,911.48 | |
| — | 20.00 | — | — | ||
| Transfer of equipment from one support to another | — | — | — | 63,811.2 | |
| — | 200.00 | — | — | ||
| Supply of Large Copper Jumper wire 160 Sqmm | — | — | — | 3,92,122 | |
| — | 200.00 | — | — | ||
| Erection of Large Copper Jumper wire 160 Sqmm | — | — | — | 70,242 | |
| — | 25.00 | — | — | ||
| Fabrication, developing and supply of fabricated Sectioning Diagram, Schematic and TSWR diagram Boards with computerized digital printing on adhesive Venyle of adequate size as per requirement | — | — | — | 48,877 | |
| — | 4.00 | — | — | ||
| Development & supply of Appendix-G to Station working rules with drawing erection | — | — | — | 1,09,601.2 | |
| — | 30.00 | — | — | ||
| Manufacturing, Supply & erection of Engine Stop Board of size 600 x 900 mm made of 2 mm thk. Aluminium alloy sheet | — | — | — | 57,711.3 | |
| — | 75.00 | — | — | ||
| Supply of various types 25KV caution Board / Plates as per explanatory Notes | — | — | — | 28,070.25 | |
| — | 75.00 | — | — | ||
| Erection of various types 25KV caution Boards / plates as per explanatory Notes | — | — | — | 6,676.5 | |
| — | 75.00 | — | — | ||
| Supply of various types of 25KV Danger Boards / plates as per explanatory notes | — | — | — | 37,851.75 | |
| — | 75.00 | — | — | ||
| Erection of various types of 25KV Danger Boards / plates as per explanatory notes | — | — | — | 4,809.75 | |
| — | 20.00 | — | — | ||
| Design, manufacturing, supply of Retro Reflective type Sigma Board with non- reflective black ground as per RDSO drg. No. TI/Drg/OHE/PLTBRD/RDSO/ 00036/12/0 (Size 450 mm x 600 mm) and RDSO specification No. ETI/OHE/33A (12/97) Rev. 8 or latest including transportation and all taxes etc. | — | — | — | 36,187.2 | |
| — | 20.00 | — | — | ||
| Cost of 4 Nos. 12mm dia GI nuts & bolts 300 mm long (fully threaded) with necessary washer, spring washer for different OHE Mast / Portals etc including transportation and all taxes | — | — | — | 4,972.2 | |
| — | 20.00 | — | — | ||
| Cost of GI backing angle for mounting arrangement size 40x40x5x450mm (4 Nos.) including transportation and all taxes | — | — | — | 8,507.4 | |
| — | 20.00 | — | — | ||
| Erection of clamps-GI backing angle for arrangement size 40x40x5x450mm (4 Nos.) 12mm dia GI nuts & bolts 300 mm long (fully threaded) with necessary washer, spring washer including Retro Reflective type sigma board with non reflective back ground at different OHE Mast / Portals etc including transportation and all taxes | — | — | — | 6,302.4 | |
| — | 10.00 | — | — | ||
| Interlocking system for isolator make interprosing consisting: a) Bolt lock type L insertion A-01; b) Lock with key exchange box with key incription B & A | — | — | — | 1,38,884.5 | |
| — | 200.00 | — | — | ||
| Supply of Anti-Bird Disc as per drawing No. TI/DRG/OHE/Anti- Bird/00001/00/01 (Sh-1 & Sh- 2) or latest | — | — | — | 1,09,316 | |
| — | 200.00 | — | — | ||
| "Erection of Anti-Bird Disc as per drawing No.TI/DRG/OHE/Anti- Bird/00001/00/01 (Sh- 1 & Sh- 2) or latest " | — | — | — | 13,644 | |
| — | 10.00 | — | — | ||
| Supply of 250m DJ Board | — | — | — | 19,263.9 | |
| — | 10.00 | — | — | ||
| Erection of 250m DJ Board | — | — | — | 2,751.3 | |
| — | 10.00 | — | — | ||
| Supply of 500m DJ Board | — | — | — | 19,263.9 | |
| — | 10.00 | — | — | ||
| Erection of 500m DJ Board | — | — | — | 2,751.3 | |
| — | 10.00 | — | — | ||
| Supply of DJ open Board | — | — | — | 16,420.7 | |
| — | 10.00 | — | — | ||
| Erection of DJ open Board | — | — | — | 2,985.2 | |
| — | 10.00 | — | — | ||
| Supply of DJ close Board | — | — | — | 16,421.8 | |
| — | 10.00 | — | — | ||
| Erection of DJ close Board | — | — | — | 2,991.1 | |
| — | 10.50 | — | — | ||
| Handling, Leading, loading and Transportation charges for Railway supply material from different Railway sites and released material from different Railway sites, if any to concerned TRD Depot | — | — | — | 29,196.41 | |
| — | 40.00 | — | — | ||
| Supply of aluminium bus bar connectors Bus terminal (6310) | — | — | — | 82,992.8 | |
| — | 40.00 | — | — | ||
| Erection of aluminium bus bar connectors Bus terminal (6310) | — | — | — | 1,597.2 | |
| — | 150.00 | — | — | ||
| Supply for Plastering of brick / retaining wall with 1:4 cement and sand mortar | — | — | — | 8,664 | |
| — | 150.00 | — | — | ||
| Erection for Plastering of brick / retaining wall with 1:4 cement and sand mortar | — | — | — | 7,137 | |
| — | 40.00 | — | — | ||
| Supply and fixing of Cast iron / good quality plastic body Silica Gel breathers | — | — | — | 18,990.8 | |
| — | 100.00 | — | — | ||
| Drilling of holes in mast/rails with contractor's own labour and T&P complete | — | — | — | 3,274 | |
| — | 100.00 | — | — | ||
| Supply of Contact Wire Parallel clamp (LARGE) RI No. 1031-2 with RDSO Drg .No. ETI/OHE/P/1030-2 REV-D or latest | — | — | — | 21,933 | |
| — | 100.00 | — | — | ||
| Supply of Contact Wire Parallel Groove Clamp RI No. 1031-3 Complete with fasteners as per RDSO Drg. No. ETI/OHE/P/1030-3, Rev-A. RDSO Spec. No. TI/SPC/OHE/Fittings/0130 with A&C slip No. 1 or latest | — | — | — | 21,778 | |
| — | 100.00 | — | — | ||
| Supply of Contact Wire Parallel Clamp (Small) RI No.-1041-2, RDSO Spec: TI/SPC/OHE/Fittings/0130 with A&C Slip No.1, Drg. No.: ETI/OHE/P/1040-2 Rev.E or latest | — | — | — | 19,467 | |
| — | 2.00 | — | — | ||
| Earth auger | — | — | — | 24,000 | |
| — | 2.00 | — | — | ||
| Ladder 11.2 meter | — | — | — | 30,496 | |
| — | 300.00 | — | — | ||
| Insulation Bond Sleeve suitable for Bond strip size 40mm X 6mm as per latest RDSO spec. and Drg. | — | — | — | 31,500 | |
| — | 600.00 | — | — | ||
| Galvanized Steel Anti Creep Wire (19/2.50mm) As per RDSO specification No. ETI/OHE/36 (12/73) With A&C Slip 1 or latest | — | — | — | 49,818 | |
| — | 5.00 | — | — | ||
| — | 5.00 | — | — | ||
| — | — | — | 44,833.35 | ||
| — | : - 25 KV AS PER | EARTHING /DISCHARGE WITH A & C SLIP NO.1 CORE-ALD APPROVED DRG. NO. | AS PER OFFER:FIRMS ROD) | ||
| — | 5.00 | — | — | ||
| Tool Kit (spanners D & O type of various size) 10-11 to 33-34 No. | — | — | — | 92,750 | |
| — | — | — | 14,38,432.09 | ||
| — | 36.00 | — | — | ||
| Erection of galvanized steel fabricated masts / other supporting structure | — | — | — | 3,54,310.56 | |
| — | 18.80 | — | — | ||
| Erection of fabricated and galvanized steel work (SPS) other than mast with necessary components | — | — | — | 1,70,378.76 | |
| — | 96.00 | — | — | ||
| Erection of Single bracket assembly | — | — | — | 2,02,693.44 | |
| — | 96.00 | — | — | ||
| Erection of insulators for single bracket assembly | — | — | — | 1,33,516.8 | |
| — | 1.50 | — | — | ||
| Erection of OHE with complete fitting (For Conventional type) without Contact & Catenary Wires as per explanatory Notes | — | — | — | 39,778.01 | |
| — | 20.00 | — | — | ||
| Erection of 9-Tonne insulator | — | — | — | 28,125.2 | |
| — | 14.00 | — | — | ||
| Erection of Section Insulator assembly including bar insulator for conventional OHE | — | — | — | 47,129.74 | |
| — | 8.00 | — | — | ||
| Erection of 25KV Single Pole(SP) Isolator without earth contact assembly | — | — | — | 36,081.44 | |
| — | 40.00 | — | — | ||
| Erection of 25KV post / pedestal insulators for isolators | — | — | — | 15,324 | |
| — | 200.00 | — | — | ||
| Erection of copper bus bar 18mm | — | — | — | 24,586 | |
| — | 40.00 | — | — | ||
| Erection of material for termination of OHE conductor | — | — | — | 40,722.4 | |
| — | 90.00 | — | — | ||
| Dismantling of Bracket Assembly | — | — | — | 1,46,321.1 | |
| — | 0.60 | — | — | ||
| Dismantling of fabricated steel other than mast | — | — | — | 9,477.46 | |
| — | 12.00 | Each Span | — | ||
| Raising / Restoration of OHE height as per OHE profile by Change of incumbrance / Re-droppering of span | — | — | — | 22,911.48 | |
| — | 20.00 | — | — | ||
| Transfer of equipment from one support to another | — | — | — | 63,811.2 | |
| — | 200.00 | — | — | ||
| Erection of Large Copper Jumper wire 160 Sqmm | — | — | — | 70,242 | |
| — | — | — | 6,302.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril-2022.pdf
ATTACHMENT
Amendment letter for GCC APR 2022
ATTACHMENT
Amendment letter 2 for GCC APR 2022
ATTACHMENT
Amendment letter 3 for GCC APR 2022
ATTACHMENT
Amendment letter 4 for GCC APR 2022
ATTACHMENT
Amendment letter 5 for GCC APR 2022
ATTACHMENT
AdvanceCorrectionSlipNo.6.pdf Amendment letter 6 for GCC APR 2022
ATTACHMENT
Amendment letter 7 for GCC APR 2022
ATTACHMENT
Amendment letter 8 for GCC APR 2022
ATTACHMENT
Amendment letter 9 for GCC APR 2022
ATTACHMENT
Amendment letter10 for GCC APR 2022
ATTACHMENT
Clarification for Annexure V of GCC
ATTACHMENT
Mandatorydocuments764A.pdf Mandatory documents
ATTACHMENT
JAT2025-26MRTL-
ATTACHMENT
AmendementinGCCofApr-2022.pdf
ATTACHMENT
Amendement-2GCCApr-2022.pdf
ATTACHMENT
Amendment-3GCCofApr-2022_1.pdf
ATTACHMENT
Amendment-4GCCofApr-2022.pdf
ATTACHMENT
Amendment-5GCCofApr-2022.pdf
ATTACHMENT
AdvanceCorrectionSlipNo.6.pdf
ATTACHMENT
CorrectionSlipNo7GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo8GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo9GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo10GCCofApr-2022.pdf
ATTACHMENT
GCCClarificationAnnexure-V.pdf
ATTACHMENT
Mandatorydocuments764A.pdf
ATTACHMENT
Tenderdocument764A-TRD-JAT2025-26MRTL-BPRSSectionImprovement.pdf
ATTACHMENT
Mandatorydocuments764A.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .