Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.9 LAccepted-AOC NO 403 BENGALI COLONY RANJHI JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER | |
| 2 | L2₹85.0 L+₹47,855.53 (0.57%)Rejected-Finance 316 VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹96.0 L+₹11.5 L (13.6%)Rejected-Finance 28 PRAGATISHEEL COLONY NARMADA ROAD JABALPUR 482001 M P | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Tiki Water proofing Co L3 | J.P ENTERPRISES L1 | M/s PARASRAM MULCHANDANI L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. | 500 | Sqm | 5 ₹2,500 Lowest | 10 ₹5,000 | 5 ₹2,500 Lowest |
| 2.00 | Dismantling timber scantling, unframed, 40 Sqcm and over in section in any position complete all as specified and directed. | 1.6 | Cum | 500 ₹800 Lowest | 1,000 ₹1,600 | 4,500 ₹7,200 |
| 3.00 | Dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles complete all as specified and directed. | 97.25 | Cum | 130 ₹12,642.5 | 150 ₹14,587.5 | 80 ₹7,780 Lowest |
| 4.00 | Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area n.exc 1.50 sqm each and removal complete all as specified & directed. | 18 | Each | 110 ₹1,980 | 100 ₹1,800 | 40 ₹720 Lowest |
| 5.00 | Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area exc 1.50 sqm but n.exc 4 sqm each and removal complete all as specified & directed. | 6 | Each | 130 ₹780 | 200 ₹1,200 | 45 ₹270 Lowest |
| 6.00 | Demolition of cement concrete of any description (unreinforced) in ground floors and paving not exceeding 15 cm in thickness (below or above ground level) including removal of debris to out side MD land complete all as specified & directed. | 77.25 | Cum | 250 ₹19,312.5 | 200 ₹15,450 | 90 ₹6,952.5 Lowest |
| 7.00 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete including removal of debris to out side MD land complete all as specified & directed. | 7.5 | Cum | 300 ₹2,250 | 400 ₹3,000 | 200 ₹1,500 Lowest |
| 8.00 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. | 300 | Sqm | 10 ₹3,000 Lowest | 10 ₹3,000 Lowest | 10 ₹3,000 Lowest |
| 9.00 | Demolition of stone slabs and tiles of any description or thickness, laid dry or laid dry and pointed in any mortor in floor, apron etc complete all as specified and directed | 51 | Sqm | 10 ₹510 Lowest | 40 ₹2,040 | 20 ₹1,020 |
| 10.00 | Dismantling framed trusses span exceeding 10 metres but not exceeding 15 metres complete all as specified and directed. | 5 | Each | 500 ₹2,500 Lowest | 1,000 ₹5,000 | 1,500 ₹7,500 |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
30 Aug 2025, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
SPECIAL REPAIR TO BLDG NO NP-3 AT JAK RIF RC AND SPECIAL REPAIR TO INTERNAL ROAD AT JAK RRC UNDER GE (WEST) JABALPUR
2025_MES_720202_1
81119/E8
Open Tender
Civil Works
Item Rate
270 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE (WEST ) JABALPUR
₹1.8 L
Yes
9 Dec 2025
14 Jul 2025
6 Sept 2025
14 Jul 2025
30 Aug 2025
4 Aug 2025
14 Jul 2025 - 2 Aug 2025
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling timber scantling, unframed, 40 Sqcm and over in section in any position complete all as specified and directed.
Dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area n.exc 1.50 sqm each and removal complete all as specified & directed.
Taking down Chowkhats or frame with shutter (without taking off shutter from the frame) area exc 1.50 sqm but n.exc 4 sqm each and removal complete all as specified & directed.
Demolition of cement concrete of any description (unreinforced) in ground floors and paving not exceeding 15 cm in thickness (below or above ground level) including removal of debris to out side MD land complete all as specified & directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete including removal of debris to out side MD land complete all as specified & directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness, laid dry or laid dry and pointed in any mortor in floor, apron etc complete all as specified and directed
Dismantling framed trusses span exceeding 10 metres but not exceeding 15 metres complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Removing building materials etc(other than spoil obtained from Excavation and Earthwork) to a distance up to 1.0 Km total distance, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
Earthwork in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains ( not exceeding 1.5 metre in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, for all kind of soil, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil exceeding 1.50 KM but n exc 5 KM and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for PCC(1:4:8) type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC (design mix) M-25 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed .
M&L for RCC (design mix) M-25 using 20 mm graded stone aggregates as in column, pliiars, piers, posts and struts etc complete all as specified and directed .
M&L for RCC (design mix) M-25 using 20 mm graded stone aggregate, as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams etc and similar work, vertical or to batter complete all as specified and directed.
M & L for formwork to sides of pillars, posts struts, piers, columns and stanchions, complete all as specified and directed .
Formwork to sides and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves, including supports, overhangs, etc also splays between floors and beams complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia as in stirrups, spacers and binders for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6 m means radius, built in CM 1 :6 complete all as specified and directed.
All as per Srl item No. 26 above except brick (Note : Old serviceable bricks retrieved against dismantling of brickwork shall be re-used.)
M&L for rendering 15 mm thick in cement mortar(1:6), finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on brick wall or concrete surface consisting of two layers, under layer of 10 mm thick in CM (1:6) and top layers of 5 mm thick in cement mortar 1:4 mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and difrected. (Note : water proofing compound shall be measured and paid for separately as "supply only".)
Supply only liquid water proofing compound ISI Marked, of make as approved by GE complete all as specified & directed.
M&L moorum / red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC(1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for 25 mm thick PCC(1:2:4) type B-1 using 20 mm graded stone aggregate as in sub base complete all as specified and directed.
S&F for frame work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, and similar work conforming to Fe -290 (Gd E-165), complete all as specified and directed.
M&L for 75mm thick PCC(1:3:6) type C-2 using 40mm graded stone aggregate, as in plinth protection, laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. (Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 metre and at every change of direction and shall be filled with mixture of bitumen and sand(1:3) by weight. Cost of this provision shall be deemed to be included in the quoted rate against this item)
M&L for RCC Precast cement concrete(1:2:4), type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. ( Note : Reinforcement shall be measured and paid for separately.)
S&F structural steel (framed), trussed, purlins, crane gantries,rail and fastenings and heavy bracket framing (beam, tee, angle,channel or flat sections) including distance pieces, cleat etc of grade Fe 410-W (Gde E-250) quality 'A', painted one shop coat of of zink chromate primer paint (including preparation of surface) at contractors workshop before fabrication complete all as specified and directed.
S&F rolled mild steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plates of grade Fe 410-W (Gde E-250) quality 'A', complete all as specified and directed
S & F mild steel bolts exc 12 mm but not exc 20 mm, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be filled with washer and one haxagonal or square nut, exc 30 cm long complete all as specified and directed
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes ,without any attachment, conforming to Fe 410-W (Gde E-250) quality 'A' complete all as specified and directed.
Supply and fix pre-painted galvalume aluminium zinc coating GI based 0.50mm thick(AZ-150)corrugated steel sheet of any colour having minimum tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws/ L or J type or cranked hook/ bolts as complete all as specified & directed.
M&L 20-25 mm thick Machine cut kota stone slab in flooring, laid over and including 15mm thick cement screed base in CM(1:4),laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 18-20 mm thick Machine cut kota stone in riser of steps, skirting, dado and pillar, laid over and including 10 mm thick rendering in cement mortar(1:4) on fair faces of brick work or concrete surfaces as backing and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and polishing, complete all as specified and directed.
S & F for Flat Iron(25 x 6 mm) as in wind tie including two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L suspended false ceiling system using chicago metallis (E-grid) exposed suspended system grid size 600 x 600 mm compressing of GI powder coated main runner of dimension 39 mm x 24 mm x 0.8 mm thick (Thickness comparing of GI 0.4 mm + PPPCGS/0.3 mm & weight of runner 1.35 kg for 3600 mm length) cross Tee of dimension 29 mm x 245 mm x 0.8 mm thick (Thickness comparing of GI 0.4 mm + PPPCGS/0.3 mm & weight of Tee 0.195 kg for 600 mm length) and wall angle of dimension 22.2 mm x 22.2 mm x 0.65 mm thick (Thickness comparing of GI 0.35 mm + PPPCGS/0.30 mm & weight of angle 0.700 kg for 3050 mm length) with and including 6 mm thick HPSC (High Pressure Steam Cured) pre-primed self embossed, textured design board, water, termite & fire resistance for insulation and acoustic purpose to be placed in the grid system duly suspended with 4 mm dia GI bar hangers fixed with steel dash through fasteners from purlin with butterfly clip (wt 0.007 Kg/Clip), hold down clip (wt 0.0035 Kg/Clip) with provn of light fixture complete all as Manufacturer's instruction complete all as specified and directed.
M & L Mild steel 1.25 mm thick and 150 mm dia eaves gutters, galvanised class 3, half round with rounded edges fixed with self tapping screws complete all as specified and directed.
M & L stop ends 1.25 mm thick and 150 mm dia (for spigot or socket ends) provided at ends, of size suitable to fix with 150 mm dia sheet with all connection required to make it workable complete all as specified and directed
M & L angle ends 1.25 mm thick and 150 mm dia (for spigot or Socket ends) provided at ends, of size suitable to fix with 150 mm dia sheet with all connection required to make it workable complete all as specified and directed
S & F 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls/ floor complete all as specified and directed
S & F, in repairs, PVC (SWR) bends, any radius, of 110 mm bore complete all as specified and directed
Supplu & fix aluminium (powder coated with minimum thickness of powder coating 50 micron ) three track sliding window comprising of one fly proof shutter and two glazed shutters with frames of size 92.0 mm x 31.75 mm x 1.30 mm thick and shutter frames of size 40 mm x 16 mm x 1.55 mm thick with necessary joining cleats, glazing clips , rubber gasket anodised aluminium snap beading and connected locking arrangement complete all as per Manufacturer's catalogue and specification complete all as specified and directed (Notes: (i) Cost of aluminium alloy wire cloth in panels of wire gauzed shutter shall be 0.45 mm nominal dia of wire and avg width of aperture 1.40 mm fixed with aluminium wire staples is deemed to be included in the unit rate quoted against this item. (ii) Cost of Glass filling in panels of glass shutter shall be 4 mm thick tinted sheet glass of approved make and shed/tint is deemed to be included in the unit rate quoted against this item.
S & F solar control film 25 micron reflective type sticked to glass panes as per instruction of Manufacturer complete all as specified and directed..
Taking down cement plaster etc on brick walls/ concrete (ceiling) surfaces of any descriptions including racking out joints, hacking for keys, scrubbing down with water and disposal of unserviceable materials to out side of MD land complete all as specified & directed.
M&L for preparation of newly plastered surfaces of internal wall and applying two coats of oil bound emulsion, alkali & fungal resistance, dirt resistance, interior paint of required shed (company Depot Tinted) over and including priming coat of interior premium over and including 2 mm thick wall care putty applied complete all as specified and directed.
M & L for complete removal of existing treatment & washing rubbing down and stopping of distempered and painted surface including preparation of old undecorated surface of internal wall and applying two coats of oil bound emulsion, Alkall & fungal resistance, dirt resistance, on wall over priming surface, on and including 2 mm thick wall care putty complete all as specified and directed.
M&L for preparation of newly plastered/unplastered surfaces of external wall and applying two coats of cement based paint, alkali & fungal resistance, dirt resistance, exterior paint of required shed (company Depot Tinted) over and including priming coat of exterior premium applied complete all as specified and directed.
M & L for complete removal of existing treatment & washing rubbing down and stopping of distempered and painted surface including preparation of old undecorated surface of exterior wall and applying two coats of 100 % premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, alkali & fungal resistance, dirt resistance, exterior paint of required shade (company Depot Tinted) with silicon additives @ 1.45 litter/sqm over & including priming coat of exterior primer applied @ 0.90 liter/10 sqm over new surfaces applied complete all as specified and directed.
S & F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitered joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N mm2 and resistance to spread of flame of class A catagory with property of being termite /borer proof and fixed in position with M.S. hold fast/lugs//SS dash fasteners of required dia and length complete all as specified and directed. (Note : M.S. holdfast/lugs//SS dash fasteners shall be measured and paid for separately)
S & F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of size 35 mm size comprising of virgin polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg /cum, screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2, modules of elasticity 850 N mm2 and resistance to spread of flame of class A catagory with property of being termite /borer proof and fire retardant and fixed with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws complete all as specified and directed.
M&L for factory made 35mm thick second class (Indian Sal, Bijasal, Hollock or Benteak) hardwood plain, framed, panelled shutter (two or three panels) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm thick veneered particle board with commercial veneering on both faces; size of rail and stiles as per IS: 1003 (Part-I), kiln seasoned complete all as specified & directed.
S & F for 150 mm Mild steel pressed handle oval cast type anodised complete all as specified & directed.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed etc complete all as specified & directed.
S & F 150 mm long aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed.
S & F 100mm butt hinges cast brass with mild steel hinge pin, bright polished and fixed type D-11 butt hinges complete all as specified & directed.
S & F in repair stainless steel conduit curtain rod with fancy type curtain rod 20 mm dia of any colour including end globe as approved complete including side mounting.
S & F stainless steel Bracket with fancy type for curtain rod 20 mm dia of any colour as approved complete.
S & F GI wire netting 0.90 mm dia and 12 mm mesh etc in walls ceiling stanchions beams etc including all laps cutting and waste.
M & L for forming square grooves in plaster n exc 12 mm deep and n exc 15 mm on face in top layer plaster complete all as specified and as directed.
S & F acrylic sealent for crack filler for internal & external wall surface cracks on roof wall flexible putty with excellent bonding quality complete all as specified and directed.
External Electrification
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 50 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc Complete all as directed.
Supply,laying & fixing Double Wall Corrugated (DWC) pipes made of High Density Polyethylene (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. complete all as specified and as directed , outer dia 50 mm and inner dia 38 mm complete all as specified and directed
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be considered for payment purpose)
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with sub class ‘B’ fly ash bricks, laid dry, flat, complete all as specified and directed .
Internal Electrification
Taking down carefully any type point wiring (light, fan, socket bell or power) , complete with fitting such as switches ceiling roses,lamp holders sockets,regulators,call bell light fitting with PVC conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc complete all as specified and directed .
Taking down carefully ceiling fan/Exhaust Fan of any sweep and size and depositing to MES store complete all as specified and directed .
Taking down carefully Main switch and Distribution boards any make and size complete all as specified and directed .
Taking down carefully Old unserviceable any type sub main wiring with wooden batten/PVC surface conduit of any size and making good the disturbed surfaces of walls, roof, floors etc complete all as specified and directed .
Material & Labour Submain wiring with four single core PVC Insulated cable two run of size 4.0 Sqmm multi-stranded copper conductor FRLS cable 1100 volts grade drawing into PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-stranded copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match with existing specification complete all as specified & directed. Note : - two run of 4.0 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
M/L for Sub Main Wiring two single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 6.0 Sqmm multi-stranded copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Two Nos of 6.0 Sqmm Wire and one No of 6.0 Sqmm Earth wire in One RM length Measured as one unit length.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of anti-corrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed .
One light point controlled by one switch.
One fan point/ex fan controlled by one switch.
One socket point controlled by one switch on same board.
One socket point controlled by one switch on Independent board.
Description all as per item No 84 here in before but with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 1.5Sqmm solid copper conductor PVC for 3 pin switch socket outlet 15Amp independent board complete all as specified and directed by Engineer in charge .
M/L for modular fan regulator socket type AC 230 volts complete all as specified and directed.
M/L for Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed .
M/L for Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed .
M/L for Switch socket combination 3 pin 5 and 15 Amps AC 230 volts flush type complete all as specified and directed.
M/L for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed .
Supply & Fixing Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S & F Sheet metal enclosure DBs,double door, Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts complete all as specified and directed.
S & F MCB single pole and neutral 240 volts 40 Amps, B Series complete all as specified and directed .
S & F MCB single pole 240 volts 6 to 40 Amps, B Series complete all as specified and directed .
Supply & fix, in replacement, LED Security Light Luminaire 35 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens. complete all as specified and as directed.
27 S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar triple pole and neutral vertical 415 V, 4 Ways, double door type, complete all as specified and directed. With Incoming MCCB of 100 Amps Capacity.
28. S & F MCB TPN 25 to 63 Amps, 240 Volts, minimum 10 KA, "C" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed. (Note :- Proper and suitable size cable copper lugs to be fixed with MCBs are included in unit rate of each MCB of any rating)
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.
S&F LED light fitting, square 57x57 CM, Not less than 36 Watt along with fixture Surface / Recessed /Pendent mounting LED luminaires with diffuser channel Luminaires , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed.
Road work
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 Sqm and depth n exc 50 mm by using mechanical scarifier including racking over and grading the broken-up surfaces to the proper camber or removing to a distance not exc 50M from the starting point and stacking complete all as specified and as directed.
Preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and directed.
M&L for applying evenly a tack coat of cationic bitumen emulsion (SS1) Conforming to IS: 8887 at a rate of application of 0.7 -1 kg/sqm on WBM/WMM as specified in Table 500-3 of MORTH specification for road and bridge work 2013, using mechanical sprayer after cleaning of exsisting surface complete all as specified and as directed.
M&L for bituminous premixed asphaltic semi dense concrete 30mm consolidated thickness with minimum 5.50 % binder content using paving bitumen VG-30 by weight of total mix, rolled and compacted to required camber and gradient using 8 to 12 tonne tandem vibratory roller complete all as specified and directed. Notes:- (i) Bituminous premixed asphaltic semi dense concrete shall be prepared in hot mix plant only. (ii) Bituminous premixed asphaltic semi dense concrete shall be laid with sensor paver only. (iii) Binder content shall be tested at site as directed by Engr-in-Charge.
M&L for applying evenly a tack coat of cationic bitumen emulsion (RS1) Conforming to IS: 8887 at a rate of application of 0.2 -0.3kg/sqm on bituminous surface as specified in Table 500-5 of MORTH specification for road and bridge work 2013, using mechanical sprayer after cleaning of exsisting surface complete all as specified and as directed.
M&L for premixed bituminous macadam for consolidated thickness upto 75mm or less with using 19mm graded (Grading 2) stone aggregate with minimum 4.0% binder content using paving bitumen VG-30 by weight of total mix, rolled and compacted to required camber and gradient using 8 to 12 tonne tandem vibratory roller complete all as specified and directed. Notes:- (i) Premixed bituminous macadam shall be prepared in hot mix plant only. (ii) Premixed bituminous macadam shall be laid with sensor paver only. (iii) Binder content shall be tested at site as directed by Engr-in-Charge.
M&L for preparation of existing bituminous road surfaces by removing dust, dirt grease and other foreign matters etc and after prepration of road surfaces, applying road marking having minimum 2.5 mm average thickness with & including thermo plastic (Reflective) line marker paint/ compound of uniform surface finish conforming to BS 3262 (Part-I) 1989 read in conjunction with the MORTH specification 803 clause 4.2.2 on bituminous surfaces in white/ yellow colour and super imposed with glass beads conforming to BS 6088 read in conjuction with the MOST specification 803 clause 4.3.3 complete all as specified and directed. Notes:- (i) MORTH specification 803 shall be followed strictly for execution of work & suitable machine shall be used for the marking as approved by GE. (ii) Shape, size & pattern of marking shall be as approved by GE.
Repair to potholes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth, making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadam, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cum of stone chippings, 6.3 mm size and again well rammed (including supply of premixed macadam, binder and chippings),complete all as specified and directed.
Supply and fix, in repair, aluminium casted cat eye, solar reflective type of metal body alloy, size 110mm x 120mm x 20mm fixed with and including MS stud of suitable size as per Manufacturer's instructions complete all as specified and directed.
Supply and fix solar cat's eye/ studs of size 125mmx 125mmx 25mm (shank 60mm) with aluminium alloy shell, high efficiency Mono-Crystalline Solar Panel 2.40V/ 0.30Watt having one Ni-Mh or NI-cd rechargable battery (1.2V/ 1600MA), Six Super Bright LEDs with 10,000 to 18,000 mcd (Millicandela) having flash rate 2 Hz and bearable weight 10 tons approx with view distance upto 1000 meters of any colour i.e yellow, red, blue, green or white as required at site, working temp 10-75 degree celcius, working time 3 to 4 days after fully charged battery, charging time 5 to 6 hours from direct sun light, maintenance free, un-breakable poly carbonate clear facing, automatically turns on at night and turns off at dawn including all fixing arrangment as per manufacturer's instructions complete all as specified and directed.
Supply and fix polycarbonate reflective convex mirror of size 800mm dia made of ABS/ fiber/ plastic body with upper collar complete with mounting hardware i.e. necessary clamps & nut bolts etc mounted on and including 65mm dia MS pipe having 2.0M length duly painted with and including two coats of synthetic enamel paint as approved by GE over a coat of red oxide primer and fixed on the ground after necessary excavation and earth work in any type of soil, embeding the delineators on the ground with & including PCC (1:2:4) type B1 using 20mm graded stone aggregate (minimum PCC block size 200mmx 200mmx 200mm for proper grouting) complete all as specified and directed.
Manufacturing, supplying and fixing retro reflective Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction.
Manufacturing, supplying and fixing retro reflective Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 m along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction .
Supply and fixing 100% water proof metal tubular delineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 50 mm dia mild steel pipe of 900 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC(1:2:4) (PCC block size:150x150x300mm) type B1 using 20mm graded crushed stone aggregate complete all as specified and directed.
Schedule of credit amount of Rs 1,57,610.00 to be deducted during AOC
M/s PARASRAM MULCHANDANI (BID ID -3396619)
Tiki Water proofing Co (BID ID -3389693)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .