Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.8 LAccepted-AOC KULTI COLLEGE ROAD P O KULTI DIST PASCHIM BARDHAMAN W B PIN 713343 | KULTI | PASCHIM BARDHAMAN | WEST BENGAL | 713343 | ₹4.8 L | 1 | Accepted-AOC Eligible L-1 bidder. |
| 2 | 2₹5.6 LRejected-Finance 100 33 1 R G S ROAD USHAGRAM SALANPUR 713303 WEST BENGAL INDIA | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | 713303 | ₹5.6 L | 2 | Rejected-Finance Quoted more than L-1 bidder. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not eligible |
| Sl No | Description | Qty | Unit | MANJEET ENTERPRISE L1 | ELECTRO POWER INDUSTRIES L2 |
|---|---|---|---|---|---|
| 1.00Item Description/ Heading | |||||
| 1.01Material Cost | |||||
| 1.02 | Cleaning & decarburizing of secondary coil of the Transformer & insulation by manila paper, as required | 306 | Kg | 34 ₹10,404 | 50 ₹15,300 |
| 1.03 | Providing of DPC electrolyte grade copper conductor for primary coil, as required. | 375 | kg | 752 ₹2.8 L | 750 ₹2.8 L |
| 1.04 | Formation of coil after re-winding of primary & secondary coil including supply of required materials (Primary coil 125 kg + secondary coil 102 kg), as required. | 676 | Kg | 24 ₹16,224 | 25 ₹16,900 |
| 1.05 | Cost of pre-compress board for separator & oil duct & placement, as required. | 3 | LS | 5,200 ₹15,600 | 7,000 ₹21,000 |
| 1.06 | Cost of wooden forma for formation of primary & secondary coil, as required. | 3 | LS | 1,800 ₹5,400 | 2,200 ₹6,600 |
| 1.07 | 100KVA, 11kV/415V Transformer:Replacement of all worn-out gaskets including top cover, terminal bushing etc., as required. | 3 | LS | 3,700 ₹11,100 | 3,000 ₹9,000 |
| 1.08 | 100KVA, 11kV/415V Transformer:Providing and fixing of current carrying contacts for primary side terminals of rated size, as required. | 3 | no | 2,300 ₹6,900 | 2,500 ₹7,500 |
| 1.09 | 100KVA, 11kV/415V Transformer:Providing and fixing of current carrying contacts for secondary side terminals of rated size, as required. | 4 | no. | 2,000 ₹8,000 | 2,500 ₹10,000 |
Tender Value
₹4.8 L
EMD Value
₹6,000
Closing Date
23 Feb 2026, 5:00 pmClosed
AE EnM
S. B. Area
Repairing/rewinding of 03 nos. 100 KVA, 11kV/440V Power Transformers, and preventive maintenance of 02 nos. 250KVA, 11kV/440V AND 01 no. 315KVA, 11kV/440V Power Transformer under S. B. Area.
2026_ECL_352945_1
GM/SBA/EnM/Tender/25-26/101
Open Tender
Electrical and Maintenance Works
30 days
S. B. Area
Please refer tender documents.
6 documents required · 6 mandatory
₹6,000
9 Apr 2026
12 Feb 2026
24 Feb 2026
12 Feb 2026
23 Feb 2026
12 Feb 2026
12 Feb 2026 - 16 Feb 2026
Item Description/ Heading
Material Cost
Cleaning & decarburizing of secondary coil of the Transformer & insulation by manila paper, as required
Providing of DPC electrolyte grade copper conductor for primary coil, as required.
Formation of coil after re-winding of primary & secondary coil including supply of required materials (Primary coil 125 kg + secondary coil 102 kg), as required.
Cost of pre-compress board for separator & oil duct & placement, as required.
Cost of wooden forma for formation of primary & secondary coil, as required.
100KVA, 11kV/415V Transformer:Replacement of all worn-out gaskets including top cover, terminal bushing etc., as required.
100KVA, 11kV/415V Transformer:Providing and fixing of current carrying contacts for primary side terminals of rated size, as required.
100KVA, 11kV/415V Transformer:Providing and fixing of current carrying contacts for secondary side terminals of rated size, as required.
De-hydration & filtration of transormer oil of 3 nos. 100KVA, 2 nos. 250 KVA & 01 no. 315 KVA.transformers, as required to match the oil's standard di-electric strength.
250KVA & 315KVA 11kV/415V Transformer:Replacement of all worn-out gaskets including top cover, terminal bushing etc., as required.
250KVA & 315KVA 11kV/415V Transformer:Providing and fixing of current carrying contacts for primary side terminals of rated size, as required.
250KVA & 315KVA 11kV/415V TransformerProviding and fixing of current carrying contacts for secondary side terminals of rated size, as required.
Up & Down Transporting with loading & unloading charges, as required.
Providing of insulating materials, as required.
Connection studs with insulator, as required.
Installation & commissioning of 100 KVA, 11kV/440V Transformer on existing position, incl. hiring of lifting equipments, as required to complete the work in all respect.
Transportation charges of oil filter machine set with oil testing machine, as required.
Providing and fiixing of earthing electrodes of 2" dia x 3000 mm long, as required for matching standard earth resistance.
Less:Unused old scrap value.
Labour Cost:
Labour cost for sl.no.1 to sl. No.18, as required to complete the work in all respect.
P. F. amount for labour cost
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
technical_365745.pdf
techsummary_365745.pdf
finance_365745.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tendernotice_2.pdf
PDF • 1.41 MB
Tendernotice_3.pdf
PDF • 1.03 MB
BOQ_365745.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid