Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being L-1. | |
| 2 | L2₹22.5 L+₹78,617.10 (3.62%)Rejected-Finance | L2 | Rejected-Finance found in order but L2 | |
| 3 | L3₹24.4 L+₹2.7 L (12.6%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L3 | Rejected-Finance found in order but L3 | |
| 4 | L4₹26.2 L+₹4.5 L (20.5%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-Finance found in order but L4 | |
| 5 | L5₹26.4 L+₹4.7 L (21.5%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L5 | Rejected-Finance found in order but L5 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
6 Jun 2024, 6:00 pmClosed
HQ CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
REPAIR/MAINT OF HT OH LINE, GOD/DO FUSE, UG CABLE AND ALLIED WORKS IN SOUTH AREA, BHAGAT LINE AND DABATHWA UNDER E/M (E/S) AT GE (U) E/M MEERUT CANTT
2024_MES_653505_1
94106/MRT/2024-25/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE (U) E/M Meerut
₹80,000
Yes
31 Aug 2024
11 May 2024
10 Jun 2024
11 May 2024
6 Jun 2024
30 May 2024
Amount
Supply ,laying , testing & commissioning of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) with stranded aluminium conductor 11 KV grade (Earthed system cable) as per IS 7098 Part-II, of following sizes all as directed including dismantling and taking out from trenches old one. Note:- (a) Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection for road crossings, HT termination joints will be measured and paid separately all as specified and directed. Make:- Polycab wires Pvt Ltd, Gloster Cables Ltd, KEI Industries Ltd.
a) 3 core 240 Sqmm
b) 3 core 185 Sqmm
c) 3 Core 120 Sqmm
d) 3 Core 95 Sqmm
Relaying of old existing serviceable cables of any size and description obtained from item No:-1 here in before complete all as specified and directed.
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil and n.exc 10 Sqm on plan and leveling of bottam Complete all as specified and directed.
Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each all as specified and directed.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover factory made as per IS 5820-1970, class HV, type 1, size 300mm x 180mm x 40mm complete all as specified and directed.
Re-laying only old reterieved unreinforced precast concrete cable cover for protection of cable complete all as specified and directed
M&L for auguring of hole suitable for passing 40mm to 150 mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables, pipe line specified and directly coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
Supply and fixing in replacement of GI tubing light grade galvanised with all fittings laid in trenches/ on pole/ wall/ floor etc for protection of cable complete all as spd and directed of following sizes:- Make:- Jindal/ Tata/ Zenith
a) 100 mm bore
b) 80 mm bore
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size of the following sizes and Complete all as specified and directed. Make : RAYCHEM, 3M(M-SEAL), CAB SEAL, DENSONS
(a) 50 sqmm to 95 sqmm
(b) 120 sqmm to 185 sqmm
(c) 240 sqmm to 300 sqmm
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size of the following sizes and Complete all as specified and directed. Make : RAYCHEM, 3M(M-SEAL), CAB SEAL, DENSONS
(a) 50 sqmm to 95 sqmm
(b) 120 sqmm to 185 sqmm
(c) 240 sqmm to 300 sqmm
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size of the following sizes and Complete all as specified and directed. Make : RAYCHEM, 3M(M-SEAL), CAB SEAL, DENSONS
(a) 50 sqmm to 95 sqmm
(b) 120 sqmm to 185 sqmm
(c) 240 sqmm to 400 sqmm
M&L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators complete all as specified and directed. Make: Indian Aluminium Co /Bhart Conductor /Jaipuriya Brothers
M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height, 150 mm dia for 33 KV volts grade complete all as specified and directed. Make:- JB/ BHEL/ Pactil/ Reychem
M&L for replacement of PG clamps, parallel grove clamps, tee clamps & GI nut, bolts of required size other connectors for connecting ACSR dog conductors for jumpring all as required at site complete all as specified and directed.
S&F disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts all as specified and directed. Make:- JB/ BHEL/ Pactil /Reychem
S&F in replacement of danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for HT 25x20 cm size including dismantling old one complete all as specified and directed.
Supply , install, testing and commissioning in replacment of HT 11 KV Switch air break, with DO fuse gang operated, triple pole , mechanically operated, mounted on insulators and MS channel frame, with operating mechanism made out of 25 mm dia GI medium grade pipe suitable for operation from ground level with locking arrangement complete for current rating 200 Amps complete all as specified and directed. Make:- JB/ BHEL/ Pactil.
S&F in replacment of HT lightening arrestor metal oxide type (gap less) heavy duty triple pole for 33 KV overhead line ,36 KV rated highest system voltage, long duration distribution discharge class type, IP 55 Degree of protection, 100(kVp) at 65 kA High current impulse withstand with normal discharge current of 10 KA complete with all fittings conforming to IS: 3070 part-3 effectively connected with earthing system complete all as specified and directed. Make:- JB/ BHEL/ Pactil / GE power /oblum
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in soft / loose soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and complete all as specified and directed or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in soft / loose soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) and dismantling old defective earthpit. .
M&L, Surface Dressing/Cleaning for 2/4 pole structure area / transformer plinth area / sub station surrounding area including removing of tree branches, small tree, plants and bushes etc complete all as specified and directed.
Supply , install, testing and commissioning in replacement of existing unsv outdoor type, 33 KV gang operated switch, rotary type, double break of current rating upto 400 Amps, triple pole each pole consisting of galvanised steel base, HT insulators as per IS, non ferrous knife and spray, loaded contacts, arching horns of adequate section to break magnetizing current of the transformers, horizontal pipe of adequate length for phase seperation adequate length of GI pipe for operation from ground level and operating handle with locking arrangement complete in both ON and OFF position. All ferrous parts hot dipped galvanised and non ferrous heavily tinned to with stand weather suitable for vertical mounting complete all as specified and directed. Make:- JB/ BHEL/ Pactil/ ECE
Finding out the cable fault of any size and any capacity of cable from LT 1100 Volt grade to 33000 KV with the help of cable fault loacator and with Necessary disconnection of cable from two ends and connection after repairs and having the following items with electrician at site up to length of 0.5 KM cable complete all as specified and directed:- (a) Surge Generator with accessories - 01 Nos,(b) Head Phone - 01 Nos ,(c) Pin Point set T-505 with accessories - 01 Nos (d) Earthing cable with clamp - 01 Set ,(e) Cable fault locator T-905 with accessories - 01 Nos ,(f) TC-808 with accessories - 01 Nos ,(g) Soldering Iron - 01 Nos ,(h) Plier - 01 Nos ,(j) Soldering paste - 01 Nos (k) Capacitor Unit - 01 Nos ,(l) Capacitor connecting cables - 01 Nos ,(m) Power cable - 01 Nos (n) Nose plier - 01 Nos ,(o) Card for SSG -1100 - 01 Nos. Note:- Transportation charge for shifting cable fault locater will deem to be including send job and nothing extra on this account will be admissible. (ii) Contractor will ensure that after intimating fault contractor have to be arrange fault locator machine within 6 hours,if contractor is unable to bring fault locator with in stipulated time penalty of Rs 250.00 per hours will be charged from contractor. (iii) Contractor will arange electrician to connect cable for testing and if any excavation is required on the site then also he will be arrange labour for the same.
S&F in replacement of existing 33KV out door Type Single Phase oil cooled Potentail Transformer IS:3156 rated voltage 33KV peak voltage 36 KV 50Hz frequency Basic insulation Level primary:36kv/70kv/170kv(p)secondry :3kv for 1 minute class of insulation A type creepage distance 900mm (minimum) Ratio 33000/√3:110/√3-110/√3Volt Burden core-I100VA,core -II 100VA.complete all as spd and directed. Make-JYOTI,AE,LAKCHMI
Supply and errecting steel tubular pole swaged type 11.0 Meter long, type 410 SP-55, IS-2713 marked complete with M&L for mild steel base plate (fillet welded to poles), pole cap/final taper plug, bolts, nuts, washers etc including necessary excavation and earth work in soft/loose soil, PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distanc not exceeding 50m and depositing where directed. Painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of black & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m height complete incl shifting all Existing connecting / Chanel/ bracket coomplete all as specified and directed.
NITHYA INFRATECH
Jain Traders
Shikha Enterprises
GEPS PROJECTS
M/S JPS Electrical Engineer & Contractor
M/S ROORKEE ENGINEERING
SHALABH INDIA INDUSTRIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .