| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-Finance PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹4.5 Cr | L1 | Accepted-Finance YES |
| 2 | L2₹4.7 Cr+₹18.7 L (4.18%)Accepted-Finance | ₹4.7 Cr+₹18.7 L (4.18%) | L2 | Accepted-Finance YES |
| 3 | L3₹5.1 Cr+₹61.5 L (13.8%)Accepted-Finance PLOT 1 SECTOR B POCKET 1 LOCAL SHOPPING COMPLEX VASANT KUNJ NEW DELHI 110070 | ₹5.1 Cr+₹61.5 L (13.8%) | L3 | Accepted-Finance YES |
Tender Value
Refer Docs
EMD Value
₹9.8 L
Closing Date
7 Sept 2020, 11:00 amClosed
Dr B K Singh CCE
Chief Construction Engineer (RandD) Central Rao Tula Ram Marg Behind Army HQ Camp Delhi Cantt 110 010
CONSTRUCTION OF IES GATE INCLUDING PROVISION OF WEIGHING BRIDGE WITH CONTROL ROOM HARD STANDING FOR PASSING VEHICLE AND SECURITY PROVISION AT ORDNANCE FACTORY NALANDA
2020_DRDO_577214_1
CCE(RandD)C/NALANDA/IEs Gate/ENQ-II
Limited
Civil Works
Item Rate
365 days
RAJGIR NALANDA
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
Yes
Chief Construction Engineer (RandD) Central
₹9.8 L
Yes
11 Sept 2020
13 Aug 2020
8 Sept 2020
14 Aug 2020
7 Sept 2020
14 Aug 2020
Amount
CHAPTER - I EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; as directed by Engineer-in-Charge. (a) All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. (a)All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
Supplying and filling in plinth with locally available sand under floors including, watering, ramming consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. (a) Chlorpyriphos/Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. (a) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
Supply and laying earth brought from outside MoD land in road embankment to proper grade and level in layer of 150mm thickness and consolidating with road roller to achieve the modified proctor density of 97%, all complete as per drawing, specficiations and directions of Engineer-in-Charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 meters
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (a) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
CHAPTER - II PLAIN AND REINFORCED CEMENT CONCRETE WORK.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor block plain window sills, fillets etc. up to floor five level, excluding the cost of centering, shuttering and finishing : (a) 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).Applying a coat of residual petroleum bitumen of grade of VG- 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Shelves (Cast-in-situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Extra for shuttering in circular work .
Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). (a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (a) Thermo-Mechanically Treated bars. Fe-500 D confirming to IS :1786
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth
Brick edging 7cm wide 11.4cm. deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
CHAPTER - III BRICK WORK:
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level (a) Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
CHAPTER - IV STEEL WORK
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (a) Fixed to openings / wooden frames with rawl plugs etc.,
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (a) In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (a) Hot finished welded type tubes
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing bolts including nuts and washers complete.
Supplying and fixing of precoated Zincalume/Galvalume sheet roofing of 0.5mm TCT -AZ-150, 550 mpa (Alumunium Zinc Alloy couting of 150 gms, per sqm total on both sides) as per AS: 1397 in cover width of 1000-1020 mm, (size, shape and pitch of corrugation as approved by Engineer-in-charge).The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap.The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength.The raw material shall be of Tata BlueScope , Jindal. The steel sheet shall be fastened with 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportaion and should be suppplied in single length upto 12meter or as directed by Engineer-in-charge.
Supply & fixing of Roof flashing and trims (parapet flashing, transition trims, expansion joint trims and ridge caps) manufactured from same material as roof panels, fixed as per manufacturer recommendation flashing girth up to 600mm.
CHAPTER - V FLOORING
Cement plaster skirting upto 30 cm height with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. (a) 18 mm thick.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete. .
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. (a) Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. (a) Size of Tile 600x600 mm
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and polished machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment. epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all level. Granite of any colour and shade (a) Area of slab over 0.50sqm
Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge (a) Granite work
Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with expoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in-charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting, mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately) Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess / less cement used as per design mix is payable/ recoverable separately. (a) Cement concrete prepared with batch mixing machine.
Providing and fixing in position pre-moulded joint filler in expansion joints.
Providing and laying in position polysulphide sealing compound for expansion joints etc.
Providing and laying Polythene sheet (400 micron thick) confirming to IS :2508 antifriction layer on the sub base course complete as per specifications.( Overlaps atjoints of pvc sheet should be 100 mm wide )
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (a) 300 mm dia RCC pipes.
Providing and placing in position 100mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes,of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick ,100mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage ,all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
CHAPTER - VI ROOFING
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.
Laying cement concrete using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS2645 and approved by Engineer - in- charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS:2645 and approved by Engineer - in- charge .
Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS:2645 and approved by Engineer - in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making of 300x300 mm square 3mm deep.
The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.
With average thickness of 120mm and minimum thickness at khurra as 65 mm.
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including unplasticised - PVC moulded fittings/accessoriesto IS : 13592 Type jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. Inclusive of all fittings. (a) 160mm diameter
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 20 cm x 20cm and weighing not less than 995 grams.
CHAPTER - VII FINISHING
12 mm cement plaster of mix : (a) 1:6 (1 cement : 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix (a) 1:6 (1 cement : 6 fine sand)
6mm cement plaster of mix: (a) 1:3 (1 cement : 3 fine sand)
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : (a) 1:3 (1 cement : 3 fine sand)
cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement (a) 20mm cement plaster
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers:
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. (a) Two or more coats on new work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (A) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work
Providing & fixing chicken wire mesh at the junctions of RCC and brick work, 100mm overlapping on both sides with all necessary hardware etc., complete.
CHAPTER - VIII ALUMINIUM WORK :
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion (a) Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) (a) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particale board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters & partition frame with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of Engineer-in-charge.. (a) Prelaminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): :
With float glass panes of 4.0 mm thickness
With float glass panes of 5.50 mm thicknes
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, Hardwyn make (model 3000) or equivalent for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (a) With Stainless Steel cover plate minimum 1.25 thickness
Providing and fixing aluminium casement window fastener of required length for aluminium windows with necessary screws etc. complete. (a) Powder coated minimum thickness 50 micron aluminium.
Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge (a) Powder coated minimum thickness 50 micron aluminium.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing Interlocking deadbolts ISI marked with 6 Levers double action mechanism ( Operable by key from both side of the door ) with Key Hole fixed with key plate with necessary SS screws etc. complete (best make of approved quality).
Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (a) Twin rubber stopper
Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed of required colour and shade, with necessary screws bolts, nut and washers etc. complete
CHAPTER -IX : SANITARY INSTALLATIONS
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required. (a) W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : (a) White vitreous china flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing wash basin with CI brackets,15mm brass type(pressmatic)pillar tap,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. W.B Hindware model 10080 (a) White vitreous china wash basin(round/oval under counter) size 580 mm x 430 mm with single 15mm CP brass pillar tap.( CP waste-Jaquar model no. ALD 709/approved equivalent,pillar tap-Jaquar model no. 031/approved equivalent).
Providing and fixing white vitreous china urinal of appx. size 610x410x380mm with push type urinal flushing arrangement including fixing to wall with suitable brackets all as per manufacturers specification & direction of Engineer-in charge with standard size C.P.brass flush pipe,spreader with unions & clamps(all in CP brass)including painting of fittings, cutting and making good the walls and floors where required.
Providing & fixing urinal partition of 12 mm th toughened glass ( size 675 x 330 mm) complete with brackets bolts nuts for grouting to wall complete in all respects.
Providing and fixing 5mm thick beveled edge mirror of superior glass of approved quality and of required shape and size, fixed with teak wood beading / pvc of size 40x20mm with french spirit polish, 6mm thick water proof ply wood on back of the mirror etc. complete with two or more coats of black bituminous paint at the back of ply.
Providing & fixing in position C.P. brass twin coat hook including cutting necessary C.P. brass screws complete.
Providing and fixing C.P.brass bib cock of approved quality conforming to IS : 8931. (a) 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (a) 15 mm nominal bore
Providing & fixing Health Faucet with 8mm dia, 1M long PVC tube and wall hook.
Providing and fixing 100mm sand cast iron grating for gully trap.
Providing & fixing in position C.P. brass towel rail (600mm long X 20 MM DIA ) including cutting necessary C.P. brass screws complete.
Providing and fixing C.P. Brass towel ring ( 200 dia size) complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality colour and make.
Providing & fixing in position CP soap dish.
Providing and fixing CP Brass Bottle Trap for Wash basin .( Bottle trap-Jaquar model no. ALD 769 / approved equivalent ) .
CHAPTER - X : WATER SUPPLY
Providing and finxing G.I. pipe (medium) complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall
15 mm dia nominal bore
20 mm dia nominal bore.
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Providing and fixing G.I.pipes complete with G.I. fittings and clamps i/c making good the walls etc. concealed pipe including painting with anti corrosive bitumastic paint, cutting chase and making good the wall.
15 mm dia. nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (a) 65mm dia pipe
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. (a) 65mm dia pipe
Providing and fixing brass stop cock of approved quality complete.
15 mm nominal bore
20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
25 mm dia nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 Cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside palstering with cement mortar 1:3 (1 Cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design: (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work.
15 mm diameter pipe.
20 mm diameter pipe.
25 mm diameter pipe.
32 mm diameter pipe.
40 mm diameter pipe.
50 mm diameter pipe.
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)
15 mm nominal bore.
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore (a) 15 mm nominal bore
Providing and fixing unplasticised P.V.C connection pipe with PTMT Nuts coller and bush of approved quality and colour. (a) 15mm nominal bore with 45cm length
Providing and placing on terrace (at all floor levels) Polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement amd making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (a) 50 to 80 mm nominal bore
CHAPTER - XI : DRAINAGE
Providing and fixing trap of self cleansing design with cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. (a) 100 mm inlet and 100 mm outlet centrifugally cast (spun) iron S&S as per IS 3989.
Extra for providing & Fixing 100mm CP brass grating for trap instead of cast iron screwed down or hinged grating.
Providing and fixing soil, waste and vent pipes. 100 mm dia (a) Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
Providing and fixing single equal plain junction of reqd. degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100x100x100mm (a) Sand cast (spun) iron pipe IS-3989
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100x100x100mm (a) Sand cast (spun) iron pipe S&S as per IS 3989.
Providing and fixing bend of required degree . 100mm (a) Sand cast (spun) iron pipe S&S as per IS 3989.
Providing and fixing collar. 100 mm (a) Sand cast (spun) iron pipe S&S IS-3989
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : (a) For 100mm dia. Pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W./R.C.C. pipe including bed concrete as per standard design:
100 mm diameter
150 mm diameter
Painting G.I. Pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality:
32 mm diameter pipe
40 mm diameter pipe
50 mm diameter pipe
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : (a) 100 mm diameter pipe
Providing and fixing G.I. Inlet fitting of suitable size with 2 & 3 Nos. G.I. Socket 32 & 40 welded G.I. pipe and dipped in hot bitumen complete in all respect. (a) 100 mm diameter pipe (Hopper )
Providing lead caulked joints to sand cast iron/centrifugally cast(spun) iron pipes & fittings of diameter :. (a) 100 mm
Providing and fixing 100mm diameter C.P. Brass cleanout plug with M.S. flanged tail pieces, 6mm dia nut & bolts, gasket and washers fixed to C.I. Pipe with drip seal joint complete in all complete including cutting and making good the walls and floor wherever required. (a) with 100 mm dia. Pipe
Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design. 180x150mm size P type (a) with common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil (a) Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90 x 80 cm and 45 cm deep including CI cover with frame(light duty) 410x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg).
With common burnt clay F.P.S. (non modular) bricks of class desigation 7.5
Inside size 120 x 90 cm and 90 cm deep including CI cover with frame(medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg). (a) With common burnt clay F.P.S. (non modular) bricks of class desigation 7.5
Extra for depth for manholes Size 90x80cm (a) With common burnt clay F.P.S. (non modular) bricks of class desigation 7.5
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minium cross section as 23mm x 25mm and over all minium length 263mm and width as 165mm with minium 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail lenth on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent indentification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size ) complete as per design.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete: (a) 150 mm dia. R.C.C. pipe
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete (a) 100 mm diameter
Providing and fixing terminal guard 100 mm dia (a) sand cast (spun) iron S&S as per IS 3989.
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter (a) 100 mm
Septic tank in R.C.C. including excavation in all kind of soil, P.C.C. in 1;3;6 / 1:2:4 R.C.C. - M25 work in foundation walls and slabs, FE-415 TMT Reinforcement, PVC incapsulated orange colour foot rest, R.C.C. Precast manhole cover shaft, sludge chambers etc. complete with waterproof plaster inside/outside & 40mm Thick PCC flooring as per enclosed drg. (a) 50 users.Size = 4.5 x 2.0, Liquid depth 1.1 m)
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
CHAPTER - XII INTERNAL ELECTRIFICATION
SUB-HEAD-I: POINT WIRING
Point wiring for light/fan/exhaust fan starting from DB to point control box & point control box to the outlet using 2 runs of 1100 volt grade 1.5 sq mm multi strand & 1 run of 1.5 sq. mm. FRLS PVC insulated copper cable conductor in 25/20 mm dia 2 mm thick PVC conduits concealed in slab/wall/ceiling/above false ceiling conforming to IS : 732 including all accessories such as junction boxes conduit bends elbows and ceiling rose, including the cost of providing and fixing a 6 amp 240 Volt grid plate mounted switch with moulded cover plate in zinc chromate passivated MS box and including circuit wiring, including circuit wiring wih 2x2.5Sqmm multistrand FRLS PVC insulated copper cable conductor all complete as per standard specifications and relevant drawing (each circuit shall have independent earth wire and lightpoint/fixture shall be earthed. Circuit wiring is included to point wiring rate)
One light point controlled by one switch.
Two light point controlled by one switch.
Three light point controlled by one switch.
One ceiling fan point controlled by one switch and electronic regulator of 150 watts. Concealed in MS fan hook box. Or bracket fan
Exhaust fan point controlled by one 6 A switch & ceiling rose.
Wiring for 2/3 pin 6A light switch socket outlet point with 1.5 sq.mm FR.LS PVC insulated copper conductor multistrand cable in 25/20 mm dia 2 mm thick PVC conduits recessed/surface, conduit including providing and fixing 2/3 pin 6A socket outlet concealed in zinc passivated boxes embedded in walls including continuous running of 1.5 sq.mm. solid copper earth wire as required
Supply and wiring for ( Ist power point ) 6 pin 240 volt 16 amp single phase and neutral switch socket outlets (one outlet wired on one circuit) with FRLS 2x 4.0 sq.mm PVC insulated stranded / multistranded copper conductor 1100 volt grade wires in 25mm dia surface / concealed PVC (2mm thick) conduit including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and including providing and fixing of a 6 pin 240 volt 16 amp socket outlet with safety shutters and 16/6 Amp 240 volt single pole grid plate mounted switch with moulded cover plate in a recessed zinc chromate passivated MS box including earthing of the 3rd pin with 1x 4.0 sq. mm 1100 volt grade PVC insulated stranded/ multistranded copper earth wire complete as required.
Supply and wiring for ( 2nd power point ) 6 pin 240 volt 16 amp single phase and neutral switch socket outlets ( Looped with Ist power ) with FRLS 2x 4.0 sq.mm PVC insulated stranded / multistranded copper conductor 1100 volt grade wires in 25mm dia surface / concealed PVC (2mm thick) conduit including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and including providing and fixing of a 6 pin 240 volt 16 amp socket outlet with safety shutters and 16/6 Amp 240 volt single pole grid plate mounted switch with moulded cover plate in a recessed zinc chromate passivated MS box including earthing of the 3rd pin with 1x 4.0 sq. mm 1100 volt grade PVC insulated stranded/ multistranded copper earth wire complete as required.
Point wiring for 25 amp single phase socket outlets with2X 6 sq mm PVC insulated 1100 volt grade multi stranded copper conductor wires in 25 mm dia PVC recessed and/or surface conduiting system including the cost of cutting/making good chases in brick work and including the cost of supplying and fixing including providing & fixing moulded plate type 6 pin 6/25 Amps socket with plug top and single phase motor starters of the minimum features of current setting over load protection outlet in recessed MS box- including the cost of loop earthing with 1X6 sq mm PVC insulated copper conductor wires complete as per specifications and as required.
SUB-HEAD-II: FANS & LIGHT FIXTURES
Light/fan fixtures :-
Supply and installation of following type fluorescent/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. Bipin Rotor type lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps.(make Philips or equivalent/Wipro/Decon).
1 x 12 W led box type fixture make PHILLIPS CAT- BN -550-W LED-12-3000
1 x 43 W LED mirror optic surface type fixture make PHILLIPS- SM-366C-LED-33-6500 PSU-OD-WH
15 W - LED- ceiling surface type light ing fixture PHILIPS- DN170C-LED 10S 6500 PSU-WH
150 W - metal halide - ceiling surface type light ing fixture PHILIPS- MWF -231-1X MHNTD-150
Ceiling fans Supplying and fixing of 1400mm sweep ceiling fan with 300/600 mm standard down rod and electrical connection as required etc.
Exhaust fans SITC of of 900 rpm, exhaust fans complete with motor, a set of blades, cowl, adjustable type louvres, grouting bolts, power improvement capacitors including making holes in the wall to suit the size of fan and as per Havels/Crompton/Bajaj make (a) 230 mm dia.
SUB-HEAD-III: DISTRIBUTION BOARD
Supplying installation, testing and commissioning of surface/recess mounting vertical/horizental type three pole and neutral,prewired, sheet steel with double , MCB distribution board 415 volt/220 volt, dust protected, duly phosphatized and powder painted ,inclusive of 200 amps tinned copper busbar, common netrul link, earth bar, din bar for mounting MCB detachable gland /knock out plate, and with built in loose wire box, and superior make terminal connectiors for all incoming and outgoing circuits duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/neutral link and ready for installation including following incoming & outings as required LPDB (a) 6 Way TPN MCB DB with 40Amp 4P MCB as incomer and 18 Nos. 6 to 20 A SPMCB as outgoings
Sub Head -IV: LT CABLES
Supplying & laying of following sizes 1100 volt grade XLPE insulated PVC sheathed Copper conductor armoured cables as per specification in existing trenches/pipe, cable trays, ducts, laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning.
3 core 2.5 sq. mm
3 core 1.5 sq. mm
Cable End termination of the following XLPE insulated PVC sheathed aluminium/copper conductor armoured cables of 1100V grade including supplying and fixing of bimetallic crimping lugs, double compression glands with earthing.
3 core 2.5 sq. mm
3 core 1.5 sq. mm
SUB-HEAD-V: EARTHING
Supplying and laying of 8 SWG GI wire hot dip galvanized in ground / pipe along with PVC armoured cable as required.
Supply, Installation GI Electrode Earthing with 40 mm dia and 3 meter length, The electrode should be hot-dip galvanized with 120-150 micron. The GI Strip In Pipe Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg JAM Fill compound to provide maximum contact between the electrode and JAM Fill Compound. Backfill compound should be eco-friendly and having RoHs certification. GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI. The earthing pit should be cover with FRP cover, of 300 x 300 mm. GI Electrode earthing should be as per JAM 193. Make - JMV , Bradley, Coron.
SUB-HEAD VI: SERVICES, COMPUTER/ TELEPHONE
Providing and fixing of a telephone (Jack type) cord grid plate mounted outlet unit (RJ-11) with moulded cover plate along with top in recessed zinc chromate passivated MS box complete as required for telephone system.
Supply and installation of CAT-6 cable complete as required.
Supply & fixing of following sizes of PVC. conduit 2mm thick complete with conduit accessories in recess and/or surface conduit including cost of cutting & filling chases for recessed conduiting and for surface conduit, cost of providing saddles, hangers, supports from soffit of slab etc. including providing fish wire as required . (a) 20 mm conduit(TELEPHONE)
Supply and laying of 25 mm dia GI pipe under road / paved area crossing etc. including excavation back filling ramming and making good.
Sub Head -VII : External elctrical
Supplying & laying of following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing trenches/pipe, cable trays, ducts, laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling , clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning. (a) 3.1/2 core 35sq. mm
Cable end termination of the following XLPE insulated PVC sheathed aluminium/copper conductor armoured cables of 1100 volt grade including supplying and fixing of bimettalic crimping lugs, double compression glands with earthing. (a) 3.1/2 core 35 sq. mm
Supply and installation of following RCC (NP-2class) Hume pipe under paved areas, including providing 75 mm thick cement concrete all around pipe 1:3:6 (1 cement, 3 coarse sand and 6 crushed stone aggregate). (a) 100 mm dia ID
CHAPTER - XIII : Weigh bridge
Design and Supplying,installation testing and commissioning of 60 MT weigh bridge including all machinery and related civil,electrical and mechanical work required for proper functioning of weigh bridge and as per specification given below and as per approved design and drawing (to be submitted by contractor and approved supplier) manufacture: Jyoti Weighing System Pvt Ltd ROCKWAY Weighbridge Technologies Mettler Toledo Weigh bridge solution or equivallent as per approved by Engineer-in-Charge. Supply & istallation 60 ton weigh bridhe Capacity 60,000 kg Platform Size 9m x 3m Deck Size 4.5m+4.5m Accuracy 10 kg Material Specification Top Plate Thickness 10 mm No. of U - Beams 6 U - Beam Thickness 5 mm End Plates 16 mm Loadcell Mounting Plates 32 mm Electronics No. of Load cell 6 Loadcell Capacity 30 Tons Each Loadcell Make Vishay-Revere Loadcell Type COMRESSION Indicator Type 7 Segment LED Indicator Data Transfer Interface RS232
M.P.KHAITAN
RMS CONSTRUCTION PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .