Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹66.7 LAdmitted-Finance | -14.99% | ₹66.7 L | L1 | Admitted-Finance |
| 2 | L1₹66.7 LAdmitted-Finance | -14.99% | ₹66.7 L | L1 | Admitted-Finance |
| 3 | L1₹66.7 LAdmitted-Finance KRISHNA KUMAR AGRAWAL ODISHA | -14.99% | ₹66.7 L | L1 | Admitted-Finance |
| 4 | L1₹66.7 LAdmitted-Finance | -14.99% | ₹66.7 L | L1 | Admitted-Finance |
| 5 | L1₹66.7 LAdmitted-Finance | -14.99% | ₹66.7 L | L1 | Admitted-Finance |
Updated dates
Tender Value
₹78.4 L
EMD Value
₹78,430
Closing Date
24 Dec 2025, 5:00 pmClosed
O/o The Superintending Engineer, OTDC Ltd. BBSR
O/o The Superintending Engineer, OTDC Ltd. BBSR
Repair and Renovation of Way Side Amenity Centre at Durgapali in Bolangir Dist.
2025_OTDC_123311_1
BP-I/23/2025-26 Dt. 29.11.2025
National Competitive Bid
Civil Works - Buildings
90 days
Durgapali, Bolangir
As per DTCN
3 documents required · 3 mandatory
₹10,000
₹78,430
Yes
2 Mar 2026
17 Dec 2025
26 Dec 2025
17 Dec 2025
24 Dec 2025
17 Dec 2025
17 Dec 2025 - 21 Dec 2025
Providing and applying 2 coats of plastic emulsion paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free for foreign materials, sand papering smooth the intermediate coats, providing necessary primer including of all materials, labour, conveyance, taxes, royalties, csaffolding, charge, (colour & shade to be approved before procurment & use)
Finishing wall surface with Acrylic wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T & P etc complete as per direction of Engineer-in-charge.
Wall painting two coats with Weather coat paint exterior grade of approved make & approved shade over a coat of primer to make an even finished surface of walls of approved make and finished smooth and even surface to receive painting of approved shade and quality after cleaning the plastred surface perfectly by watering and brushing including cost of material,paint, brushes, all labour, taxes, loading, unloading, scaffolding, T & P etc as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)
Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railing ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)
Earthwork in excavation in all kinds of soil upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in following types of soil including moorum, hard stony earth, earth mixed with boulders, DI rocks etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge.
Supplying and filling the Foundation & Plinth with clean coarse river sand of approved quality from approved quarry, laying in layers not exceeding 150mm thick, watering and ramming including cost, conveyance, royalty and cost of all labour, T&P etc. as required for the work complete as per direction of the Engineer-in-charge.
Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors
using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and ,es of all materials with all labour, cess and T&P required for the work etc. complete in all respect.
R.C.C. work of Grade- M 20 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position.
Column Base
Column
Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.
Providing, fitting, fixing up false ceiling of approved design and drawing in all floors with G.I Section on 4 walls to be fixed by means of steel screw and PVC plug and the G.l. grid 2’-0”x2’-0” to be suspended from ceiling by using 12.5mm thick Gypsum Board including cost of all materials, all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge
Providing fitting, fixing of 6mm thick black glass including all cost of labour, T&P , hire charges of drilling machine, labour charges etc. complete excluding cost of laminated board/Glass.
Providing vitrified tile flooring using Vitrified tiles of premium grade having thick of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm coloured /printed series(homogeneous) of approved quality, colour in floors, treads on steps and landings in all floors at all height on 25mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and , cost of all labour, sundries, T&P required for the work in all respect as per specification and direction of Engineer- in- charge.(Make:-SOMANY/JONSON/NITCO/KAJARIA OR EQUIVALENT) (Test certificate/report should be furnished prior to execution/after procurement of materials)
Apply a coat of Dr. Fixit Roofseal Classic New (diluted with water in the ratio 2:1) as a self-priming coat at the rate 10 –11.00 sq.mt. /liter/coat in SSD condition. Apply 1st coat of Dr. Fixit Roofseal Classic New at the rate of 0.50 / litre / Sq.mt / Coat. Laying a 45 GSM glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat. While the 1st coat is still wet. Allow the first coat to dry for 4-6 hours. Apply second coat of Dr. Fixit Roofseal Classic New with the same application coverage. Application direction of second coat should be perpendicular to that of the first coat. Allow second coat to dry for 4-6 hours. Apply third coat of Dr. Fixit Roofseal Classic New at an application direction that is perpendicular to that of the second coat with same application coverage rate to achieve total dry film thickness of 750 to 800 microns at forced coverage at the rate of 1.50 – 1.60 litre / Sq.mt in 3 coats. Check to see no void surface is left untreated / uncoated. Allow the system to air cure for 7 days minimum. The material having following technical Specification ASTM D 6083 M – Type II, Attains a Tensile Strength of 2.5 N/mm2 confirming to ASTM D 2370; Elongation at break ≥ 200% confirming ASTM D 2370, Adhesion to Concrete 2.0 N/mm2 confirming ASTM D 4541 and Crack bridging ability up
Supplying all materials, labour, T&P and fixing health faucet of Jaquar Cat. No.-Jaquar ALD 573 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing standard sized pillar cock of Jaquar CON 011KN or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing Bib cock of Jaquar CON 107KN or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing standard sized 15mm dia Angular Stop cock of Jaquar CON 059KN or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying and fixing urinal of Hindware make having cat no 60001 or equivalent of approved make including all fittings like 450mm long connection pipe, waste coupling nut, waste pipe, urinal spreader etc of approved make etc complete as per PH specification and direction of the Engineer-in-charge.
Providing fitting, fixing of Al. door with anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member with frame section as9221 with tappered clip no. 4660 and ther frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P , hire charges of drilling machine, labour charges etc. complete excluding cost of laminated board/Glass.
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge
to 2 mm, Air cure the coating for 7 days, before water pound test for 48 hrs. The system comes with 10 years waterproofing warranty from M/S Pidilite Industries or, equivalent make.
Supplying all materials, labour, T&P and fixing of 150x150mm CP overhead shower of Jaquar SHA 477 with arm SHA-479L600 or equivalent etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing 2 way Bib cock of Jaquar CON 041 KN or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing standard sized CP towel rail - 24" of Jaquar Cat. No.-ACN-1111SM or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing standard sized CP towel ring of Jaquar Cat. No.-ACN-1121BN or equivalent etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying all materials, labour, T&P and fixing standard sized Connection Pipe etc complete including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Providing 16 mm thick C.P. 1:6 finished even and smooth on masonry walls including racking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumbs and levels and providing grooves as shown in the drawing including cost of all materials, labour, conveyance, loading and unloading, taxes, royalty, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge.
Supplying all materials, labour, T&P, fitting and fixing 50mm UPVC pipes & fittings of approved make , both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:2:4) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P, fitting and fixing 25mm CPVC pipes & fittings of approved make , both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:2:4) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P, fitting and fixing UPVC SWR pipes & fittings of approved make confirming to IS-13592, both below and above ground level / floor and on walls including supply of bobbins, nains, screws, wooden cleats, pipe clips as per requirement, including earth work in excavation and fitting, including cuting walls and floor and making good the damages with cement concrete (1:2:4) with hard granite chips, incluidng scaffolding wherever necessary all complete as per the PH specification and direction of the Engineer-in-charge.
Supplying all materials, labour and T&P for fitting and fixing white glazed vitreous china porcelain Orissa pattern water closet of hindware make having cat no 20018 or equivalent type of approved make confirming to IS-2556 and top inlet for sinking into floor with 100mm PVC 'P' trap etc. including supply of necessary cement concrete for fitting the closet etc. complete in all respect in all floors including cost, conveyance and taxes of all materials etc. complete and as per PH specification and direction of Engineer-in-charge.
Civil Work
Supply all materials, labour,T&P for fitting and fixing of PVC cistern of hindware make sleek fresh ISI or equivalent type of approved make complete with all parts and internal fittings of approved make with ISI mark and supplying of necessary brackets, screws etc 32mm dia flush bend, 15mm dia 450mm long PVC water connecting pipe of jaquar make having cat no ALD 803AB with CP or brass union nuts at each end as per PH specification all complete as per direction of Engineer-in-charge.
Supplying and fixing urinal of Hindware make having cat no 60002 or equivalent of approved make including all fittings like 450mm long connection pipe, waste coupling nut, waste pipe, urinal spreader etc of approved make etc complete as per PH specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and fixing stainless steel soap case etc complete including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Supplying and fitting of 1 H.P. Single phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm
Providing and fixing in position wood plastic composite door frame with appropriate length of ETA Approved carbon steel galvanized (minimum 5 microns) double threaded 6.8 grade Polyamide PA 6 grade sleeve HRD C 10 anchor suitable for fastenings both on concrete & masonary/aerated blocks including cost of all materials, labours, T & P etc required for the work. complete in all respect as directed by the Architect/Engineer-in-charge
Providing and fixing of 35mm thick WPC Door Shutter(Solid) with teak edge leaping to the periphery of the shutter with pilishing as per detailed drawing with including, all hardwares & fixtures, SS tower bolt(150mm),Door stopper,SS aldrop(250mm),SS handle(200mm length),ss handle (150mm length) & SS Butt hinges -125mm x 65mm x2.12mm .including cost, conveyance, loading, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge
Providing and lying plain cement concrete of proportion (1:2:4) in foundation and floors using Portland slag cement (PSC) with black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading and royalties of all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
Plinth Beam/Grade Beam
Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire Finolex /Polycab/ Anchor / Havells/KEI/Eq) (Make of modular box,cover,switch & socket-Legrand Arteor/schneider Zencelo/Panasonic Vision/Eq)
GROUP-A
GROUP-B
GROUP-C
Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer-in-charge. (Make of wire KEI /Polycab/ Anchor / Havels/Eq) Average Length: 3 mtr
Recessed wiring to ceiling fan point with 1.5 sqmm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FRLSH PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire KEI /Polycab/ Anchor / Havels/Eq) Group c
Supply and fixing of 5 / 6 amp socket outlet with 6 Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer-in-charge.
Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer-in-charge.(Make of wire KEI /Polycab/ Anchor / Havels/ Finolex /Eq)
Supply and fixing of 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge.
Supply and fixing of 1x 6 + 1x16 amp socket outlet controlled by 1x 6 + 1x16 amp 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer-in-charge.
Supply and fixing of 6 pin 16 amp socket outlet with 16 Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge.
Supply and fixing of 6 pin 16 amp socket outlet ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge.
Supply and fixing of 32 amp Modular DP switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer-in-charge.
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Repairing of Doors & Windows by providing skilled labour etc. completed.
Repairing of Doors & Windows by providing Highskilled labour etc. completed.
Cleaning of septic tank and inspection chambers by mechanical/manual means, including dewatering, removal and safe disposal of sludge, scum, and accumulated waste, washing with water, reinstating covers, and making the system operational, complete as per specifications and directions of the Engineer-in-Charge.
Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.Note for MCB- There should be colour indication for tripping On ,Off & Trip/There should be mid trip position for toggles for electrical fault conditions.(With 2 Years Warenty)
Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 12 way SPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40 Amp DP MCB (10KA) Outgoings-10/16/20A SP MCB 10KA-10 Nos of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make-L&T/ Hager/ Schneider/ Legrand/ Eq)
Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-63Amp / 40Amp FP MCB (10KA) Outgoings-10/16/20A SP MCB 10KA-12Nos of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make-L&T/ Hager/ Schneider/ Legrand/ Eq)
Supply and fixing of 5 amp to 32 amp rating 240 V "B"/C series 10KA single pole miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.
Supply and fixing of 40 amp DP miniature circuit breaker "C" curve suitable for inductive loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.
Supply and fixing of 63 amp TPN miniature circuit breaker "C" curve suitable for inductive loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.
FITTING & FIXTURE
Supply, Installation, Testing and Commissioning of Plastic body Exhaust fan 200 mm sweep with louvers of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make- Havells/Crompton/Usha/Orient/Bajaj).
Supply, Installation, Testing and Commissioning of Metal body Exhaust fan 300 mm sweep of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make- Havells/Crompton/Usha/Orient/Bajaj).
Supply, Installation, Testing and Commissioning of 1200 mm sweep ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make- Havells/Crompton /Usha/Orient /Bajaj).
Supply, Installation, Testing and Commissioning of 400 mm sweep Wall fan etc of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make- Havells/Crompton /Usha/Orient /Bajaj).
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj).
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make-Finolex/ Anchor/Polycab /HAVELLS /RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 10 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj).
Supplying, storing, laying, testing and commissioning of 3.5c x 35 Sq. mm armoured Aluminium Cable direct in ground including excavation, sand cushining protective covering and refilling the trench of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge.
Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge.
Supplying and laying 25 mm x 6 mm Copper earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering of approved make complete with all materials & labour as required as per the direction of Engineer-in-Ch
SITC of 9 watt LED Ceiling Recessed mounted Downlight with Low depth Aluminium (99% Purity) Heat Sink, available in Round and Square shape. PC diffuser in white powder coated finish with independent electronic low THD (<10%) LED driver of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj).
Providing and fixing 8 SWG CU wire on surface or in recess for loop earthing of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge.
Supply, installation, testing & commissioning of coil earthing etc as required as per the direction of Engineer-in-Charge.
Supplying, installation and commissioning of 35W LED post top light luminaries having Versatile pressure die-cast aluminium IP66 with high power LED as light source to be fixed on the ends of pole etc complete with connection as required for the work and as per direction of Engineer-in-Charge.(Make: Havells Ruby /K- Lite/ BAJAJ/ CG/Jaquar).
Supply, installation, testing & commissioning of IP 65 LED street Light of 90 W Capacity 6000K Colour temperature with pressure die-cast Aluminium body having in built electronic driver which have 50000 burning hour road way luminaries of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge.
SITC of 12 watt LED Ceiling Recessed mounted Downlight with Low depth Aluminium (99% Purity) Heat Sink, available in Round and Square shape. PC diffuser in white powder coated finish with independent electronic low THD (<10%) LED driver of approved make with all other required materials & labour complete as per the direction of Engineer-in-Charge. (Make: Panasonic/LT/ Havells /Philips/Wipro /K lite/Crompton/Bajaj).
Supplying, storing, laying, testing and commissioning of 3 c x 4 Sq. mm armoured Copper Cable direct in ground including excavation , sand cushining protective covering and refilling the trench of approved make complete with all materials & labour as required as per the direction of Engineer-in-Charge.
Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter and control fuse etc. complete. MAKE- Legrand / Schneider/Hager/ L&T/SIEMENS/Eq.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
DTCNDurgapali.pdf
Tender Documents • 1.41 MB
BOQ_571949.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid