Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC ACCEPTED BEING L1 |
| 2 | L2₹1.5 Cr+₹3.6 L (2.49%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.5 Cr+₹3.6 L (2.49%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.6 Cr+₹10.1 L (6.90%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.6 Cr+₹10.1 L (6.90%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.6 Cr+₹15.6 L (10.7%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.6 Cr+₹15.6 L (10.7%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in particular category |
| Sl No | Description | Qty | Unit | RAMESH BABU CO L1 | UNIVERSAL ENGINEERING L3 | devan enterprises L2 | M/S SRI BALAJI ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-
(a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed .
(b) Checking water tightness of storage tank .
(c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.
(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.
(e) Checking and correct earth continuity of electrical items.
(f) Checking functioning of heating element and correct setting adjustment of thermostat.
(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
(h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix. | 450 | Each Job | 248 ₹1,11,600 Lowest | 485 ₹2,18,250 | 520 ₹2,34,000 | 350 ₹1,57,500 |
| 2.00Note : The following deemed to be inclusive in quoted rate :- | |||||||
| 3.00The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work. | |||||||
| 4.00In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. | |||||||
| 5.00In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. | |||||||
| 6.00The entire job will be carried out in entire area of Air Force stn Jalahalli | |||||||
| 7.00All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department. | |||||||
| 8.00 | Supply and fixing Heating element 1.5 KW 230 volts (ISI marked) suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed. | 180 | Each | 603 ₹1,08,540 | 300 ₹54,000 Lowest | 345 ₹62,100 | 470 ₹84,600 |
| 9.00 | Supply and fixing PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed. | 220 | Each | 121 ₹26,620 Lowest | 195 ₹42,900 | 175 ₹38,500 | 150 ₹33,000 |
| 10.00 | Supply and fixing in replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. | 35 | Each | 148 ₹5,180 Lowest | 315 ₹11,025 | 300 ₹10,500 | 270 ₹9,450 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
27 Sept 2025, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF GEYSERS SOLAR WATER HEATER SUMMER APPLIANCES DG SET AMF PANEL ELECTRICAL INFRASTRUCTURE PERIODICAL SERVICING INSPECTION OF VARIOUS EARTHING SYSTEM AND CERTAIN MISC E M WORKS AT AFTC 2 DC AREA CQAE WE AND AFS EAST WEST JALAHALL
2025_MES_728599_1
8200/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.3 L
24 Oct 2025
30 Aug 2025
4 Oct 2025
30 Aug 2025
27 Sept 2025
20 Sept 2025
30 Aug 2025 - 6 Sept 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .