Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC 2 E FRONT BLOCK 283 OLD NO 188 B P H ROAD KILPAUK CHENNAI 600010 | CHENNAI | TAMIL NADU | 600010 | ₹2.8 Cr | L1 | Accepted-AOC issue work order |
| 2 | L2₹2.8 Cr+₹3.0 L (1.07%)Rejected-Finance NO 1 PPS COMPLEX METTUR MAIN ROAD OMALUR TALUK SALEM 636455 | SALEM | SALEM | TAMIL NADU | 636455 | ₹2.8 Cr+₹3.0 L (1.07%) | L2 | Rejected-Finance since L2 |
| 3 | L3₹2.8 Cr+₹5.4 L (1.96%)Rejected-Finance KOODUTHURAIPATTI KONGARAPATTI PO HARUR TK DHARMAPURI DISTRICT | ₹2.8 Cr+₹5.4 L (1.96%) | L3 | Rejected-Finance since L3 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
20 Sept 2023, 3:00 pmClosed
The Member Secretary
SPORTS DEVELOPMENT AUTHORITY OF TAMIL NADU Jawaharlal Nehru Stadium Raja Muthiah Road Periyamet Chennai 600003 Tamil Nadu India
Construction of Chief Minister Mini Stadium at Kolathur Assembly Constituency in Chennai District
2023_SDAT_368809_1
sports/2023-2024/017
Open Tender
Civil Works
Lump-sum
270 days
kolathur
ref tender document
2 documents required · 2 mandatory
₹0
₹1.5 L
Yes
11 Oct 2023
11 Sept 2023
21 Sept 2023
12 Sept 2023
20 Sept 2023
12 Sept 2023
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Providing Pre - construction Anti - termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentration under grade slab and grade beam, all round the Pile Caps, Catch basins, trenches, pits, tunnels, wall trenches, back fill, plinth filling, junction of wall and floor. External perimeter of building, surrounding of pipes, expansion joints, below U.G. sump and retaining/side walls etc. as per instructions of chemical manufacturer as directed by the Department officer/ Architect. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 or equivalent BS specification. The chemical to be used as insecticide for the treatment shall be Biflex Tc, TC stands for Termiticide Concentrate for Termite Control (Bifenthrin) and the application shall be diluted 1 part of chemical Biflex Tc with 49 parts of water to get 0.05% emulsion and strictly in accordance with the manufacturer’s specification.Including cost of chemicals labour charges,transport and storing etc complete and as directed by the department officers
Supplying and filling in foundation, basement, etc with M- sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying filling in foundation,basement etc with filling suitable embankment filler materilas in layers of not more than 15cm thick well watered,rammed and consolidated etc., complete complying with standard specification and as directed by the department officers.
Plain Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Damp proof course with Cement Mortar 1:4 (One Cement and Four M-sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification.
Cement Concrete M 25 1:1:2 (One Cement, One M-sand and Two hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers
a) Upto basement
b) Ground floor
Cement Concrete 1:1-1/2:3 (One Cement, One and a half M-sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers -Foundation and Plinth
Ground floor
Brick work in Cement Mortar 1:5 using best quality II class Ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.
Inbetween column Up to plinth level
In ground floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
a) Upto basement
b)For Plane Surfaces Such as RCC Floor Slab,Roof slab,Beams,Lintels,Bed Blocks,Landing Slab,Waist Slab,Portico Slabs-Ground floor
c)For Plane Surfaces Such as Rectangular or Square RCC Columns,Sunshades,Top and Bottom slab of RCC Boxing etc
Supplying fabricating and placing in position steel reinforcement using mild steel or ribbed star rods for all RCC works as per the design given including cost of steel and binding wire also in all floors steel and binding wire shall be supplied by the contractors etc., complying with standard specifications.
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc.,
Overall length
Supplying and fixing of Flush door shutter using Teak wood frame of size 127mm x 76mm and Door shutters Single leaf in position using 35mm thick solid core Flush shutters with teak play on both sides with teak wood lipping alround including cost and labour for fixing the hold fasts and furniture fittings etc.,complete as directed by the departmental officers complying with standard specification.
Providing and fixing fixed window with 12mm thick toughned glass door including aluminium work with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws,Glazing, paneling and dash fasteners all complete as per architectural drawings and the directions of Engineer-in-charge.Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing of M.S.grill of approved design for open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Plastering with Cement Mortar 1:5 (One cement and Five M-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M-Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Flooring with following Plain ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers
Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Providing and laying flamed finish Anti Skid Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse M-sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Supply & Fixing of Swimming Pool Glass mosaic Tiles 1"x 1" with (Random Blue Colour Mix Only) with Dubond or Semtro max Tile Adsehive and Dubond or Semtro max Cement based joint gruot materails, complete
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M-sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Providing and filling the tile joint with epoxy grout with followingspecification:Surface preparation including cleaning the joint to befree from dust and loose particles. Providing masking tape on eitherside of the tile joint edges and providing sealing the tile gap withepoxy tile joint grout and finishing neatly and as directed by theepartmental officers. The rate inclusive of cost of materials andlabour, etc., complete.
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M-sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cementmixed withmathcing colouring pigments etc., The granite stone slabs and othermaterials to be used shall be got approved by the Executive Engineerconcerned before use on work, etc.,complete as per standardspeicification.
Nosing for Granite Slab
Providing and Laying Water proofing for Swimming Pool concrete shell, balancing Tank and pool over flow gutter complete with chemicals & labour
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wallsurface ect., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Claading walls with following best approved quality, brick tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers
Supplying & fixing in position Greenlam Sturdo Classique Invincible Toilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch impact and anti bacterial resistant 12mm thick solid compact laminate panels tested by shriram Test House. Finish of the compact laminate should be suede/ *Raw silk, which includes doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate. This also includes providing and fixing in position necessary hardware made out of Stainless steel (Grade 304) as per manufacturer’s specifications & Architects instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U-Channels, (6) SS-Shoe Box Plate (7) MS-Base Plate, (8) Top rail with Corner conntector (9) Rubber noise deafening tape (10) Screws & wall Plugs. The top fitting should consist of SS round top rail which will get fixed with pilasters, with SS panel tube holder, SS corner bend (connected with top rail) will be used on the corner of cubicle in absence of brick wall, SS wall fixing is used only on the wall which will hold the ss top rail. All screws will of 304 Grade in stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 110mm.
Toilet Cubicle with standard dimension of 2100mm Height x 1000mm Width x 1550mm Depth, which includes 600mm door size width). Toilet Cubicle I-Shape (Front Partition) with standard dimension of 1885mm Height x 1000mm Width which includes 600mm door size width). The divider height to 2100mm height All aspects specified by the manufactures, Greenlam Sturdo Classique Invincible Model or equivalent. complete as per directions of Engineer-in - charge
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
Supply and Installation of Rockwool: 50mm thick for Roofing Application: Rockwool RB Slab Density 40 + 8 kg/m3 including all works etc as per direction of architect and Engineer incharge.
Supply and Installation of 0.47MM Colour Coated Galvalume Roofing Sheets Top & Bottom 150 Gsm JSW Brand with Accesorries.
Supply and Installation of 0.50MM Thick Galvalume Eaves Gutters 150 Gsm JSW Brand with Clamp Set Accesorries
Supply and Installation of 0.50MM Thick Galvalume C -Flashing 150 Gsm JSW Brand with Accesorries.
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three M-Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
PPSandCo
VEDIAPPAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_439814.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .