Assistant Engineer, PWD
New Office Complex Building 4th Floor, Bhabani Bhawan, Alipore, Kolkata
Replacement of two Nos old AC Machine at RTO Officer Chamber, Alipore, South 24 Parganas, New Administrative Building, Alipore,Kol-27
2026_WBPWD_991613_1
WBPWD/AE/AESD/eNIT-24(2ND CALL) of 2025-26
Open Tender
ELECTRICAL WORKS ORG
7 days
Alipore
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,454
13 Mar 2026
20 Jan 2026
5 Feb 2026
27 Jan 2026
3 Feb 2026
27 Jan 2026
Supply & delivery of Inverter type split Air-conditioner machine having Cooling Capacity- 5.2 kW (Minimum), min 3 star rated, noise level not more than 51 db. This Split Air Conditioning machine should be fitted with Rotary/Scroll compressors, LCD remote incl. battery & all other accessories suitable for Refrigerant- R32 having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part- II) with all ammendments. (Make:- Mitsubishi Heavy Industries/ Mitsubishi Electric/O-General as approved by EIC)
Installation, testing & commissioning of the above-said split ACs on wall with appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleevessections of specified thickness as given below for suction andliquid lines, all accessories as per specification etc. as required.
5/8" (15.88 mm.) (for suction) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
1/4" (6.4 mm) ( for discharge) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
Supply & Laying of 4 core 1.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split AC m/c (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.I.C)
Supply & Laying of 3 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split AC m/c (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.I.C)
Supply and laying 25mm PVC pipe (heavy type) for water drainage.(25mmOD, 1mm thick) with 6mm nitrile rubber insulation with proper support & bracket as per direction. (Make- Supreme/Oriplast).
Supply & delivery of Full metal body & blade wall bracket fan 24inch (1420 RPM) (make -EPC/Crompton 600mm ACVORTEX 24 WM)
Supply & fixing of 230 V 1200 mm sweep Ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl.painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire ( Make - Orient New Breeze/ Crompton Aura 1200 or equivalent of Havells as approved by E.I.C) . The capacitor of the fan must be P2 type burst proof and must have safety wire directly linked from the fan hook to stator of fan.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. [ C-4 / 29]
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [D-14/29]
Disconnection & dismantling existing old indoor & outdoor unit of AC Machine, copper pipe etc with owns tools & takles incl. mending good damages and clearing/removing from the site as directed by EIC.
Add GST @ 18% on sl. No. 1 to 11
Add LWC @ 1% on sl. No. 1 to 12
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2424433.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid