Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.6 LAccepted-Finance | 1 | Accepted-Finance Lowest RAte | |
| 2 | 2₹33.4 L+₹84,456 (2.59%)Rejected-Finance | 2 | Rejected-Finance Higher Rate | |
| 3 | Rejected-Technical 428 SURAJ PALACE C A ROAD GANDHIBAG NAGPUR MAHARASHTRA 440002 | NAGPUR | MAHARASHTRA | 440002 | - | Rejected-Technical Technical Bid Found Not Ok. |
Tender Value
₹33 L
EMD Value
₹35,000
Closing Date
28 Sept 2023, 1:00 pmClosed
SE EDC Etah
Vidhyut Colony, Aruna Nagar, Railway Road, Etah.
Various Electrical work for strengthening of electric supply in the area of EUSD Ist Etah (EUDD, Etah) under additional business plan on Semi Turnkey basis.
2023_DVVNL_839990_1
41/2023-24/EDC ETAH
Open Tender
Electrical Works
Turn-key
Distt Etah
As per Tender Documents.
2 documents required · 2 mandatory
₹3,540
DVVNL
₹35,000
17 Oct 2023
18 Sept 2023
28 Sept 2023
18 Sept 2023
28 Sept 2023
18 Sept 2023
Amount
Supply of The Line Material as per Relevent ISS :-
Danger Board With Clamp
Stone pad
Tee Off Channal
Tee Chanel Clamp
Top Channal
Nut Bolt With Washer
Holding Clamp
Dropper Channal
11 KV Fuse Set
Dead End clamp
Copper L- Piece 62x225x12 mm
Lt Incoming Pannel with Metering Qubical
Suspension clamp
I Hook
Allumunium Lug 400 sqmm
LT Pin Clamp
Pearcing connector
Tripping Coil for VCB
LT PVC 3.5x400 sqmm
Control Cable 4x2.5 sqmm
Erection Work :-
Safe Carriage of following material from Electricty store center Etah to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-10 Kms.)
(a) 8.5 Mtr Long PCC Poles.
(b) 11 Mtr Long ST Poles.
(c.) 13 Mtr Long ST Poles.
(d) 11 KV X-Arms, weasal conductor, G.I wire, Dog Conductor, Disc Insulators, Pin insulators, clamps Abc Bunch and other required line material, if any.
(e.) 11 KV/33 KV VCB
(f) XLPE Cable (3*185 sqmm)
Safe Carriage of following from Electricty Store center Etah to Pit Site of Work through the Kacha and Pakka road loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-10 Kms.)
(a) 63/100 KVA T/F
Erection of following Poles with grouting including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
(a) 8.5 Mtr long PCC Pole
(b) 11 Mtr long ST Pole
(c.) 13 Mtr long ST Pole
Erection of D/P or section pole including drilling,cutting of material etc. and fixing of all accessories etc. complete.
(a) 8.5 Mtr Long PCC Pole
(b) 11 Mtr Long ST Pole
Fixing/ Errection of LT Incoming Pannel with Metering Equiptment, Grouting as per respoo manual all cost of labor, material and T&P which required for completion of work
Erection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer.
Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
(a) ACSR Weasel Conductor
(b) ACSR Dog Conductor
(c.) XLPE Cable 3*185 sqmm
(d) AB Cable 50/95/120 sqmm
(e.) LT PVC Cable 3.5x150
(f) LT PVC Cable 3.5x400 sqmm
Installation of 250/400 KVA T/F on newly/Old constructed Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work
11 KV TPMO
11 Kv Fuse Set
Danger Board With Clamp
Cable Joiting Kit I/D 3x185 sqmm
Cable Joiting Kit O/D and 3x185 sqmm
11 KV CT O/G 400/200/5A
11 KV CT O/G 600/300/5A
3 Phase Distribution Box
Meter Box
PVC Armoud Cable 2x6 sqmm
33 KV VCB 800A, 750MVA
11 KV VCB O/G VCB CTR 200/100/5A
Single Core PVC Cable 1x1000 sqmm
Single Core PVC Cable 1x630 sqmm
Single Core PVC Cable 1x400 sqmm
Single Core PVC Cable 1x240 sqmm
11 KV Incoming VCB 600/300/5A
LT Protection of DT (MCCB)
Vaccume Intruptor (Off Make)
Tripping Coil for VCB
33 KV Control Pannel for Double TF
Control Cable 4x2.5 sqmm
Pipe earthing of 250/400 KVA medium Power Transformers
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended netal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut
Any other material/consumable required to complete the work shall be arrange by the contractor at his own cost.
Received Back Material of Old and Scrap VCB
YASH URJAA VARDHAN PVT. LTD.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .