| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.4 L+₹96,765.35 (6.71%)Rejected-Finance | L2 | Rejected-Finance Other than lowest Bidder | |
| 3 | L3₹16.8 L+₹2.4 L (16.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest Bidder | |
| 4 | Rejected-Technical 201 SECOND FLOOR PLOT NO 4 GUPTA ARCADE LSC SHRESTHA VIHAR DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Applicant does not fulfill the eligibility criteria |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
1 Jun 2021, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt Pin-144005
Please refer tender documents
2021_MES_433807_1
CA NO CWE/JAL/K-94/2020/21 8320/94/E8
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Class E Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer Kapurthala
₹42,000
Yes
16 Jul 2021
31 Mar 2021
3 Jun 2021
31 Mar 2021
1 Jun 2021
28 Apr 2021
Amount
Taking down rolling shutters, push type or manually operated completed all as directed.
S&F steel rolling shutters 1.25mm thick push, pull or manual type without ball bearing as specified including top cover, anchoring rod, hasp and staple and including one shop coat of primer, erected as indicated in position, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed.
M&L for oiling, greasing to all parts of steel rolling shutters of any size (manually/Gear operated) for smooth functioning and refixing in the same position complete all as directed.
M&L for replacement of worn out shaft of size 50mm of rolling shutter incl taking out the same complete and all as specified.
M&L for replacement of ball bearing (6312, 6212) of rolling shutter including taking down complete and all as specified.
M&L for replacement of old tension spring with new tension spring of size 450mm for shutters not exceeding 12 Sqm each complete and all as specified.
M&L for replacement of old tension spring with new tension spring of size size 600mm for shutter exceeding 12 Sqm each complete and all as specified and directed by Engineer-in-Charge.
M&L for replacement of hood covers made out of 0.63mm thick plain steel sheet made to shape as required as the contours of the bracket plate proper fixing with angle/ flat stiffners on the top and bottom edges and fixed to the bracket plate complete all as specified and directed by Engineer-in-Charge.
M & L for running welding in repairs n.exc 6mm thickness of metal to be welded complete all as specified and directed.
Dismatling of steel gates area exc 5 Sqm & n.exc 8 Sqm & refixing after necessary repairing including replacement of wheels, bearing etc. as reqd, oiling and greasing all complete as specified and directed.
All as per item No. 11 above but area not exc 5 Sqm each complete all as specified and directed.
S&F MS wheel of 40 to 50mm thick and 18 to 20 cm height including shaft and check nuts complete including hole at centre and grooves for fixing bearings all as directed and as approved by engr-in - charge .
S&F MS wheel of 70 to 80mm thick and 28 to 30 cm height including shaft and check nuts complete including hole at centre and grooves for fixing bearings all as directed and as approved by engr-in - charge .
Dismantling of framed trusses of span n.exc 10m complete all as specified and directed by engr-in-charge.
Dismantling of mild steel work of any description complete all as specified and directed by engr-in-charge.
Supply and fixing only steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete as specified and directed.
Supply and fixing rolled mild steel Fe 410-W (Gde-E-250) quality-A in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.
S&F rolled mild steel Fe 410-W (Gde-E-250) quality-A in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated) complete all as specified and directed.
S & F rolled MS section as in roof trusses (framed), trussed, purlins, verticle members of sheds, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc fixed with angle cleats or other connecting plates confirming to Fe 410-W quality B complete.
M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by engr-in-charge.
S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other end, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm but n exc 10cm long and dia of neck is 5 to 10mm.
S & F mild steel bolts purpose made with hexagonal or square head at one end and screwed the other end or screwed end to be fitted with washers and one hexagonal or square but dia of shank exceeding 20mm and not exceeding 25mm, length of bolt exceeding 30cm long, complete and all as specified.
S & F MS plate 6 mm thick plain, cut to shape forming holes and welded to truss and verticle post all as required.
S&F repair MS sheet 1.60 mm thick plain black in steel gates and similar works, cut to size ,holes punched including round headed screws, revets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up,mitred angles etc as required.
Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings including ridges complete all as specified and directed by engr-in-charge.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and directed.
Demolition of cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) removing debris out side MoD land complete all as directed.
Material & Labour for plain cement concrete (1:4:8), type D-2, (using 40mm graded stone aggregates) in foundations, filling, mass concrete etc complete all as specified and directed.
Material & Labour for 75 mm thick plain cement concrete ( 1:3:6 ) type C-2 using 40mm graded aggregate as in plinth protection finishing the surface even and fair including making joints and filled with bituminous mastic mix proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for 100mm thick, plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregates) as in flooring/hardstanding & finishing the surfaces even & smooth with using extra cement complete all as specified and directed.
M&L for machine pressed coloured precast concrete interlocking paver block vibrator finish any shape and size conforming to IS 15658-2006 of 60 mm thickness M-30 Grade with grey cement and pigment , over and incl 25 mm thick sand coushning complete all as specified and directed.
M & L for 50mm thick, plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregates) as in roof for padding and finishing the surfaces even & smooth with using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar 1:4 over concrete surfaces such as bedding layer on roof slab with water proofing compound as per manufacturers instruction finished surface even and smooth without using extra cement complete all as specified and directed. (WPC shall be measured and paid for separately).
M&L for preparation of newly plastered surface making surface completely dry including applying a coat of bitumen primer confirming to IS :3384-1965 @ 0.30kg/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymeric weighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers laid with torching application to the surface over and including a coat of hot blown bitumen 85/25 @1.20 Kg/Sqm complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed by Engineer-in-charge.
Material & labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/Sqm including cleaning of surfaces complete all as specified.
Taking down chowkats or frames with shutters exc 1.5 sqm but n.exc 4 sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames with shutter of area n.exc 1.50 sqm each (without taking off shutters from the frame) and removing from site complete all as specifed.
S&F solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, & fixing in opening as per specification and manufacturer's instruction.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Supply and fixing 100mm butt hinges, type B-21, extruded aluminium alloy with galvanised mild steel hinge pin, anodised & fixed to PVC door complete all as specified and as directed.
S & F framed work as in doors or gates and sign boards of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete confirming to Fe 410-W (Gde-E-250) quality B complete all as specified and directed.
M&L for 2nd class hard wood factory made shutter 35 mm thick plain, framed, panelled shutters (any numbers of panels with panels of timber flat on both sides (feather edges) or of veneered particle board medium density, wood particle board with commercial face venners, supplied and fitted to chowkats.
S & F, 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc (without sash bars) fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), supplied & fixed to chowkats complete all as specified & directed.
M & L preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer - in - Charge .
S&F, galvanised mild steel wire cloth, 0.56mm nominal dia of wire & average width of aperture 1.18mm & fixed with tinned tacks, or stainless steel wire staples complete all as specified & directed
Supply & Fixing 100 mm size butt hinges, medium weight and cold rolled mild steel including welding to angle iron chokhats/cupboard shutters complete all as directed by Engr-in-Charge.
S & F 150 mm long aluminium anodized cast type handle all as specified and directed by Engr-in-Charge.
S & F aluminium anodised barrel tower bolt of extruded section 200mm long all as specified and directed by Engineer - in - Charge .
S&F 250mm long mild steel sliding door bolts plate type stove enmelled black with bright bolt not less than 12mm dia with and incl a minimum 8 bolt and nuts four on bolt plate & two on staple plate all as specified.
S&F of 150mm size, helical door springs including roller and roller plate including welding to angle iron chowkhats complete of mild steel for wire mesh shutters Complete and all as specified.
Fixing only in repairs of 150mm size, helical door springs including roller and roller plate including welding to angle iron chowkhats complete of mild steel for wire mesh shutters Complete and all as specified.
Supply & Fixing in repairs 100 mm size butt hinges, medium weight and cold rolled mild steel including welding to angle iron chokhats/cupboard shutters complete all as directed by Engr-in-Charge.
Supply & fix Steel windows 1.25 mm thick Box type (primer coated) ERW hollow ‘P’ section of size 60mm x 25mm single rebated comprises of glazed skeleton shutter EWR Sec 50mmx20mm and 1mm thick and two open able leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of EWR box type ‘T’ section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1 using 20mm graded stone aggregate. Four Nos for each window including following fittings welded to framed shutter :- (a) Holdfasts 150mm long 12mmx3mm made to shape per window -04 Nos, (b) Handle of Z Sec 20mmx25mm, 100mm long per leaf-01 No, (c) MS tower bolt 150mm long per leaf -02 Nos, (d) ‘Z’ sec 20mm x 25mm, 100 long stopper per leaf -01 No, (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges per leaf -01 No, (f) MS pintal hinges of size 75mmx12mm per leaf -02 Nos, (g) Fabrication and fixing arrangement as per drawing No CEJZ/TD/1019, Sh 1/3 to 3/3 and No. CEJZ/TD/1020, Sh 1/3 to 3/3. Note : Glass, wire cloth & painting shall be measured & paid for separately.
All as per srl item No. 55 here in before but of gauged shutter. Note for item No. 55 & 56 :- Drg No. CEJZ/TD-1019 & 1020 are not being uploaded and the same can be seen in office of CWEJRC on any working day. Wire gauge & painting shall be measured and paid for separately
S&F steel ventilators with top hung shutter including hinges, steel peg stay, complete all as specified and directed by engr-in-charge (Note : Glass/wire mesh and painting shall be measured and paid separately under appropriate item).
Supply and fix 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by engr-in-charge.
HM&L for hacking out old broken glass (any thickness size quality or description) from wooden/metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones not exceeding 0.5 Sqm complete all as specified & as directed by Engineer-in-Charge.
Material & Labour for steel gate pintle hinges (gate size up to 20 Sqm ) of MS bolts and nuts complete all as required on site and as approved by Engr-in-Charge, including cutting and welding to hold fasts , complete all as directed by Engr-in-Charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by engr-in-charge.
M&L for brick work with sub class old size 'B' bricks, straight or curved on plan, exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with sub class old size 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete as specified and directed.
Taking down cement plaster or cement lime mortar any description on brick or stone wall, etc including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by engr-in-charge.
M & L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work and finishing surfaces even and smooth without using extra cement complete all as specified & directed.
M & L for 15mm thick plaster in two layers (10mm+5mm) rendering in cement mortar 1:4 on other than fair faces of brick work and finishing surface even and smooth without using extra cement complete all as specified & directed.
M & L for 10mm thick rendering in cement mortar 1:3 on ceiling surfaces, finished surface even and smooth without using extra cement complete all as specified & directed.
M & L for preparation of new plastered or unplastered wall surfaces and applying two coats of cement base paint over a coat of cement primer complete all as specified and as directed.
M&L for preparation old decorated surfaces plastered surfaces of walls or cornics with steelwire brushes, scrapping down smoke soors, moulds, moss and efflorescent salt, tradingoil and greasy spots and applying two coats cement base paint after complete removal of existing complete all as specified and directed by Engr-in - Charge
M & L for preparation of new plastered surfaces of walls etc. and evenly applying three coats of white wash complete all as specified & directed.
M & L for two coat of white wash on old decorated plastered or unplastered surfaces of walls including preparation of surfaces after complet removal of existing treatment complete all as specified and directed by Engineer - in - Charge .
M&L for three coat of white wash on plastered/unplasterd surface on ceiling including preparation of new plastered surface complete all as spd and directed.
M & L for two coat of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces after complete removal of existing treatment complete all as specified and directed by Engineer - in - Charge .
Taking down rain water pipes (any size and pattern), including all fittings, heads, shoes, bends, swan necks, etc. removal from site (measured overall as fixed along the centre line or fittings and accessories) complete all as specified and directed.
S&F PVC rain water pipes (SWR) 110mm dia(Single socketed, in any length with rubber joints, fixed to walls with flat iron clamps complete all as specified and directed.
S&F 110mm bore, PVC (SWR) bends any radius complete all as specified and directed.
Supply and fix PVC (SWR) pipes 75mm dia pipe, single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-charge.
S&F 75mm bore, PVC (SWR) bends any radius complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 ssqm but not exceeding 0.18 sqm, in floors etc, over and incl 15mm thick screed bed in CM 1:6 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by engr-in-charge.
M&L for glazed ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm over and incl 10mm thick rendering in CM 1:4 as in vertical surfaces such as wall/dado/skirting including set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed by engr-in-charge.
M&L for machine cut kota stone slab flooring 20 mm thick over and including15mm thick cement screed base in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, treating the surface with bees wax polish complete all as specified and directed by Engr-in-charge.
M&L for machine cut kota stone slab 20 mm thick in riser of steps, skirting, dado and pillar laid over and incl 10mm thick screed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade complete all as specified and directed by engr-in-charge.
S&Fin repair vitreous china squatting pan, ‘Orissa’ pattern, size 630 x 450 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor complete all as specified & as directed by Engineer-in-Charge.
S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including supply of 32mm bore flush pipe & fixing brackets etc complete all as specified and directed.
Supply and fix 15mm bore PVC connection and 450mm long with PTMT nuts and washers complete all as specified and directed by the Engineer-in-Charge.
S&F vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or eracting stand & waste pipe, coupling etc as in repairs complete all as specified and directed.
Supply and fix 15mm bore pillar taps, cast copper alloy with capstan heads chromium plated, fancy type, screwed down high pressure with or without lettered Hot or Cold with long screwed shank and fly nuts, complete all as specified and directed by the Engineer-in-Charge.
S&F, 32mm waste coupling of PTMT (half or full threaded) (minimum weight 40mm-60 gms) with PVC waste pipe for wash hand basin fixed in repair complete all as specified and as directed.
S&F Cast Iron floor trap 100mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 (including cutting in existing floor,removing the old and place the new pieces and making good the disturbed portion) complete all as specified and directed.
S&F salt glazed stone ware gully traps square or round mouthed, type P of size 150x150mm set and jointed to drain pipe with cement mortar (1:1) and making good the disturbed portion) complete all as specified and directed.
Taking up or down, steel tubing 15mm bore and connections and removal from site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 15mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall, ceiling or laid in floors complete all as specified and directed by the Engineer-in-Charge.
Taking up or down, steel tubing 20mm bore and connections and removal from site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 20mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall, ceiling or laid in floorscomplete all as specified and directed by the Engineer-in-Charge.
S&F in repair fancy type chromium plated 15mm dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipes complete all as specified.
Supply and fix in repairs stop valves, cast copper alloy, bore dia of pipe in 15mm, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed but fancy type, Chromium Plated with long shank and cup etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fix 40mm high density polyethylene (HDPE) pipes of pressure rating 6kgf/sqm as in waste water pipes complete all as specified and as directed by Engineer-in-Charge.
S&F, sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 15 cm wide with chromium plated bracket guard and railing 60cm long fixed complete all as specified and directed.
S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats, (min weight 190gms) fixed complete all as specified and as directed by Engr-in-Charge.
Dismantling water tanks capacity exceeding 250litre but not exceeding 500litre complete all as specified and as directed by Engineer-in-Charge.
Supply, hoisting and fixing in position Rotational moulded Polyethylene water storage tank, 500 litres capacity conforming to IS-12701 (1989) cylindrical vertical type three-layered wall construction with closed top including inlet, outlet and wash out holes of approved make complete all as specified and directed.
Supply & Fixing 20mm dia Ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210gms) complete all as specified and directed.
Supply and fix in repair, 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by the Engineer-in-Charge. .
S&F urinal spreader of PTMT any colour for fixing with 15mm dia pipe (min weight 60gms) complete all as specified and as directed.
S&F vitreous china urinal, half stall type,of size 330mmx250mmx445mm white (excluding flushing cistern, flush pipe and waste pipe) with grating and union for dischage pipe complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement fixing flush pipe grating and union for discharge pipe complete fixed in repairs complete all as specified and as directed.
Supply & Fixing 4mm dia galvanised steel wire 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, n.exc. 1.5mtr wide and n.exc. 1.5mtr depth for foundation etc or for shafts, wells, casspits, manholes, pierholes etc. not exceeding 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Demolition and breaking up 150mm bore drain pipes (salt glazed ware or AC pipe) set in cement mortar and taking out from trenches complete all as specified and directed by Engineer-in-Charge
M&L for 150mm bore reinforced concrete pipes, Class NP-3 laid and jointed and complete with collars complete all as specified and as directed by Engineer-in-charge.
Material and labour for cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregates) as in bed to drain pipes of 150mm bore dia including packing under and haunching surrounding pipes with concrete after they are laid and tested all as specified and directed by Engineer-in-charge.
S & F, mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for step/rungs complete all as specified and directed.
M & L for providing pre-cast cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in cover slab for manholes, septic tank, soak well etc set in cement mortar 1:4 with plain fair faces including chamfered, weathering, throating etc including necessary use and waste of form work complete all as specified and as directed.
M&L for returning, filling in, including spreading, levelling, watering and well ramming the approved earth/soil in layers n.exc 25cm thick in any type of soil complete all as specified & directed. Note: Punned down thickness shall be measured
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete all as specified & directed.
Material and labour for pumping out liquid or semi liquid sludge from sewage wells or septic tanks of any size or any depth mechanically and an open trench shall be made for disposal/ evaporation of liquid sludge. After use, the whole area shall be covered with bleaching powder and covered with soil about 15cm thick complete all as directed by the Engineer-in-Charge. Note: During the cleaning of sewage wells, the alertnate arrangements shall be made by contractor by temporary pumping for clearing sewage disposal.
Material and labour for clearing blockage of sewage line between two manholes by pressure pumping / roding and removing the garbage out of the cantonment area and make the site neat & tidy to the entire satisfaction of the Engineer-in-Charge.
M&L for designing septic tank for 10 users complete all as per specification and as shown on drawing, and all as directed by the Engineer-in-Charge.
Taking down carefully existing point wiring of any type (i.e. wooden surface conduit casing capping or concealed conduit) complete for light or fan or socket or power etc on wooden batten or in conduit including fittings and accessories like switches, sockets, lights fitting, regulator, wooden board and making good disturbed portion to match with existing complete all as specified and directed.
Material & labour for concealed point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated and unsheathed cable 1100 volts multistranded, copper conductor cable (FRLS) drawn through and including PVC concealed conduit not less than 20mm dia bore medium grade (ISI marked) and accessories like bends, tees, junction boxes etc, fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS, copper multistranded cable as earth wire including sunken pressed steel terminal boxes and bakelite white/ coloured top sheet cover 3.0 mm thick , for One light point / fan point controlled by one way switch complete all as specified and directed.
All as per srl item No 121 here-in-before but for 3 pin socket outlet, 5 Amps on same board with other switches complete all as specified and as directed
All as per srl item No 121 here-in-before but 3 pin switch socket outlet, 5 Amps on independent board complete all as specified and as directed
All as per description of srl item No 121 here in before but using 2.5 sqmm (nominal area) PVC unsheathed cable independent including PVC cable copper conductor with 2.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor and connecting for earth dolly for 3 pin socket out let 15 Amps on independent board. complete all as specified and directed
S&F switch piano flush type 5 amp, SP one way, complete all as specified and directed.
S&F switch piano flush type 15 amp, SP one way, complete all as specified and directed.
S&F socket outlet 5 pin, 5 Amps flush type multipurpose complete all as specified and directed.
S&F socket outlet multipurpose 2 in one, 3 pin 5/15 Amps flush type multipurpose complete all as specified and directed.
Taking down old unserviceable FTL fittinng 36/40 watt and Supply and fixing surface mounting energy saving LED tube light fitting/batten with LED T8 tubelight with PC body, 1x20W, 230V , light distribution lumen output should be at least 1800 lumen with a CCT of 6500K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed. Make: Crompton battencat part No. DMLN1LT8-16 & LED cat part No. LT8-20-865-2 or equivalent make as mentioned in grp 1 of Appx "B"
S&F MCB single pole, 6 to 32 Amps 240 volts, B series complete all as specified and directed. Make: C&S electric product code CSMBS1B6 to CSMBS1B32 or equivalent make as mentioned in grp 1 of Appx "B"
S&F MCB single pole & neutral, 6 to 32 Amps 240 volts, B series complete all as specified and directed. Make: C&S electric product code CSMBS1B6N to CSMBS1B32N or equivalent make as mentioned in grp 1 of Appx "B"
Supply and fix in repairs sheet metal enclosures for DB's, detachable gland plates flush mounting for MCBs fitted with bus bar double door earth wire and neutral link, 8 ways 240 volts complete all as specified and directed.
Supply and fix in repairs sheet metal enclosures for DB's, detachable gland plates flush mounting for MCBs fitted with bus bar double door earth wire and neutral link, 4 ways with 200 amps rated bus bar, 240 volts complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite 65 x 50 mm three terminal PVC / Polycarbonate isolated body(ISI marked) complete all as specified.
S&F angular lamp holders, with PVC insulated body with back plate suitable for batten fittings including 01 No. of LED 1 x 09 Watt, 230 Volts suitable for 230 volt AC complete all as specified and directed. Make : Havells LED cat part No. LHLDEUHEMC8R009 or equivalent make as mentioned in grp 1 of Appx "B"
Hanging only ceiling fan of any sweep including connecting up incl provision of twin core twisted flexible copper conductor cable of suitable sizefrom ceiling rose/connector to fan and GI pipe of suitable size/Steel rod, clamps, hooks, nut bolts etc as reqd on site complete all as specified. Note : Ceiling fan retrieved from dismantling shall be refixed as directed by Engr-in-Charge.
Supply and fix fan regulator, electronic step type, five steps socket type single phase, including connection complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit (II) PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed. .
Disconnecting and taking out old u/s cable of service connection/submain of any size and type from pole to DBs/main switch complete all as specified and directed.
Supply and fixing in replacement sub main wiring with two single core PVC insulated cable with copper conductor stranded and sheathed of size 6 sqmm, two runs in and including PVC concealed conduit medium grade of size not less than 20mm dia including PVC accessories complete incl cutting and chasing and making good etc incl one run of 6 sqmm PVC insulated unsheathed multi stranded copper conductor cable to common earth and connected to earth dolly complete all as specified and directed. Note 2 run of 6 sqmm cable, one run of 6 sqmm and conduit shall be measured as one unit.
M&L for brick protection using old size sub class 'B' bricks, laid flat dry but adjoining to each other laid length wise perpendicular to the axis of cable complete all as directed and directed
Supply and spread river sand in trenches as cable cushioning 8 cm below the cables and 15 cm above the cables all as directed and directed Note : Punned down thickness shall be measured.
Supply, laying and testing LT cable XLPE/PVC insulated armoured and with aluminium conductor 1100 volt grade 16 sqmm 2 core laid in trenches in floor, in ducts, through pipe or fixed along the pole complete all as specified and directed. Note:- 1. Excavation, earth work, sand cushioning, and brick protection shall be measured and paid for separately. 2. Rate of necessary lugs, thimbles and jointing material shall be included in unit rate.
Supply and fix LED building security light fitting 15 watt, powder coated pressure die cast aluminium compact LED security light including 1.5 mtr long 40mm dia GI pipe mounting bracket made to shape for fixing on wall with 40mm x 6mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washer and Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. Make: Crompton cat prt No. LSTS-15-CDL or equivalent makes as in grp1 of Appx 'B'
S & F exhaust fan metallic body, 300mm sweep, 900 RPM, single phase, 230 volt, heavy duty with lovered shutter including provision of three core flexible cable of required length of size 23/0.0076 from ceiling rose/connector to fan terminal, fixing the fan on wall with suitable size of nut, bolt & washer, all as specified and directed all as specified and directed.
Supply and fixing GI pipe 40mm dia light grade galvanised with all fittinng laid in trenches/on pole/road crossing etc for cable protection complete all as specified and directed.
DUGGAL CONSTRUCTION CO
G M BUILDERS 36
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .