Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.5 L+₹84,407 (1.89%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹46.4 L+₹1.7 L (3.91%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.8 L+₹2.2 L (5.02%)Rejected-Finance 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹47.2 L+₹2.6 L (5.75%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
27 Feb 2025, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD PULGAON 442303
REPAIRS/REPLACEMENT OF OLD VINTAGE CI/GI PIPE LINE INCLUDING ALL FITTINGS/ FIXTURES, AIR VALVES, SLUICE VALVE, FOOT VALVES AND OTHER CONNECTED ITEMS IN ZONE-II AREA UNDER GE PULGAON
2025_MES_697054_1
8208/PUL/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE PULGAON
₹90,000
Yes
17 Apr 2025
8 Feb 2025
7 Mar 2025
8 Feb 2025
27 Feb 2025
22 Feb 2025
8 Feb 2025 - 21 Feb 2025
Amount
Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers of soil not exceeding 25cm.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of rock.
M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 80 to 150 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, etc. including required size and qty nut bolts and washer complete all as specified and as directed,
M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 200 to 300mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, etc. including required size and qty nut bolts and washer complete all as specified and as directed,
Taking up old U/S 80mm bore hume pipe line/CI/GI any type water mains pipes, any class,(including all fittings),disconnecting pipes and fittings complete
All as per item No 6 above…. But for 100mm bore
All as per item No 6 above…. But for 150 mm bore
All as per item No 6 above…. But for 200mm bore
All as per item No 6 above…. But for 250mm bore
Relaying only 80mm bore old pipe in good condition/pipe taken out from trenches for repairs in any length including fittings etc.
All as per item No 11 above…. But for 100mm bore
All as per item No 11 above…. But for 150 mm bore
All as per item No 11 above…. But for 200mm bore
All as per item No 11 above…. But for 250mm bore
Supply and fix 80mm bore cast iron pipes with spigot and socket ends centrifugally casted class LA in any length suitable for rubber tytan joint and Laid in trenches
All as per item No 16 above…. But for 100mm bore
All as per item No 16 above…. But for 150 mm bore
All as per item No 16 above…. But for 200mm bore
All as per item No 16 above…. But for 250mm bore
M&L for 80mm rubber tyton joints for suitable for sockets and spigot CI pipes including rubber gasket
All as per item No 21 above…. But for 100mm
All as per item No 21 above…. But for 150mm
All as per item No 21 above…. But for 200mm
All as per item No 21 above…. But for 250mm
M&L for 80mm bore burning out lead joint in position , including removing lead to store / stacked at site to issue under credit and making new Run lead joint for spigot socket cast iron pipes and fitting, including cauking properly and making joint leak proof
All as per item No 26 above…. But for 150 mm bore
All as per item No 26 above…. But for 200 mm bore
Taking out 80mm bore old US sluice valves and supply and fix of new sluice valve PN-1.0 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and operating wheel all as directed
All as per item No 29 above…. But for 100mm
All as per item No 29 above…. But for 150mm
All as per item No 29 above…. But for 200mm
All as per item No 29 above…. But for 250mm
Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box of sluice valve spindle brass including taking apart and reassembling of 200 MM complete all as specified and directed byEngineer-in-Charge.
Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box of sluice valve spindle including taking apart and reassembling of 150 MM complete all as specified and directed byEngineer-in-Charge.
M&L in repair of rusted & crack CI water branch connection 80 to 100mm dia by using mechanical joint with connecting all accessories complete all as specified and directed byEngineer-in-Charge. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
All as per item No 36 above but for size of pipe 150mm to 300 mm dia
M&L for dismantling old wall valve chamber and construction of brick masonary new valve pit chamber of size 900mmx900mmx900mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle iron frame embeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron applying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed.
All as per item No 38 above but for size 1200mmx1200mmx1200mm.
M/S JAI BHAWANI CONSTRUCTIONS (BID ID -3251112)
SHUBHAM SALES (BID ID -3248023)
MAHARASHTRA ENTERPRISES (BID ID -3250033)
M/S. ELECTROPOWER TECHNOLOGIES (BID ID -3247504)
M/s Dara Constructions, Pulgaon (BID ID -3247300)
I P Constructions (BID ID -3250148)
Chhabra Enterprises (BID ID -3247325)
SHRIKANT CONSTRUCTION (BID ID -3249105)
Bidder Name
MAHARASHTRA ENTERPRISES
M/s Dara Constructions, Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
M/S. ELECTROPOWER TECHNOLOGIES
SHUBHAM SALES
Chhabra Enterprises
I P Constructions
SHRIKANT CONSTRUCTION
ALI AKBAR MANNAN BOHRA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .